• Title/Summary/Keyword: 수력 성능

Search Result 170, Processing Time 0.025 seconds

Prediction of Hydraulic Performance of a Scaled-Down Model of SMART Reactor Coolant Pump (스마트 원자로냉각재펌프의 축소모형에 대한 수력성능 예측)

  • Kwon, Sun-Guk;Park, Jin-Seok;Yu, Je-Yong;Lee, Won-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.8
    • /
    • pp.1059-1065
    • /
    • 2010
  • An analysis was conducted to predict the hydraulic performance of a reactor coolant pump (RCP) of SMART at the off-design as well as design points. In order to reduce the analysis time efficiently, a single passage containing an impeller and a diffuser was considered as the computational domain. A stage scheme was used to perform a circumferential averaging of the flux on the impeller-diffuser interface. The pressure difference between the inlet and outlet of the pump was determined and was used to compute the head, efficiency, and break horse power (BHP) of a scaled-down model under conditions of steady-state incompressible flow. The predicted curves of the hydraulic performance of an RCP were similar to the typical characteristic curves of a conventional mixed-flow pump. The complex internal fluid flow of a pump, including the internal recirculation loss due to reverse flow, was observed at a low flow rate.

로켓엔진용 연료펌프의 성능 시험

  • Kim, Dae-Jin;Hong, Soon-Sam;Choi, Chang-Ho;Kim, Jin-Han
    • Aerospace Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.143-149
    • /
    • 2005
  • To evaluate the hydraulic and cavitation performance of a fuel pump for a liquid rocket engine, performance tests of the pump, which consist of hydraulic tests and cavitation tests, were conducted in water environment with various condition. In the hydraulic tests, the head, efficiency and volute pressure distribution of the pump are found to follow the conventional similarity rule, whereas the secondary flow pressure shows a small deviation from the similarity rule. As the floating gap is constricted, the efficiency of the pump improves and the secondary flow pressure decreases. However, the inner diameter of bypass line orifice does not show clear relationship with the pump efficiency. In the cavitation tests, measurements of the head and the NPSH indicate that the pump shows better cavitation performance as the rotational speed of the pump increases.

  • PDF

Application Study on Domestic Production of Francis Type Hydro Turbine at Irrigation Reservoir (농업용저수지를 이용한 프란시스수차 국산화 적용 연구)

  • Lee, Chul-Hyung;Park, Wan-Soon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1632-1636
    • /
    • 2009
  • 소수력자원은 신재생에너지 중에서도 온실가스 배출량이 가장 적고 에너지밀도가 매우 높기 때문에 개발할 가치가 큰 청정부존자원으로 평가되고 있다. 본 연구는 프란시스 수차의 국산화 개발 연구로써 프란시스수차 외형설계에 필요한 기본사항과 제작, 프란시스수차의 설치 및 시운전, 프란시스수차의 성능시험을 수행하였다. 이에 대한 분석 결과, 개발된 프란시스수차는 기계적인 성능과 수력학적인 성능면에서 만족할 만한 결과를 보여주어 프란시스수차의 상용화에 대한 기반이 마련되었다.

  • PDF

The Effects of Distal Sinus on the Hydrodynamic Performance of the Prosthetic Heart Valves (인공판막 후부 공동부가 판막의 수력학적 성능에 미치는 영향)

  • 이계한;서종천
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.297-303
    • /
    • 1998
  • The sinus distal to the prosthetic heart valve influences the valve closure behavior and velocity field near the valve, therefore affects the hydrodynamic performance of the prosthetic heart valve. In order to study the effects of valve distal geometry on the hydrodynamic performance of the prosthetic valves, mechanical bileaflet valve(SJMV), monoleaflet polymer valve(MLPV) and trileaflet polymer valve(FTPV) are inserted in the test sections which have the straight and the sinus shape distal to the valve. Leakage volumes and systolic mean pressure drops are measured in the pulsatile mock circulation flow loop. Leakage volumes are slightly less and systolic mean pressure drops are higher in the sinus test section comparing to those in the straight test section, but the differences are statistically insignificant. Flow waveforms are analyzed in order to predict the valve closure behavior. The distal sinus does not affect the closure of the MLPV, but early valve closure of SJMV is observed in the sinus test section. This effect is more significant in FTPV, and the reverse flow peak of FTPV is reduced in the sinus test section. Therefore the sinus distal to the valve can reduce the reverse flow jet caused by sudden valve closure.

  • PDF

A Numerical Study on Improving the Thermal Hydraulic Performance of Printed Circuit Heat Exchanger Using the Supercritical Carbon Dioxide (초임계 이산화탄소를 작동유체로 한 PCHE의 열수력 성능 향상을 위한 수치해석적 연구)

  • Park, Bo Guen;Kim, Dae Hyun;Chung, Jin Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.10
    • /
    • pp.779-786
    • /
    • 2015
  • The objective of this study is to propose a new channel shape that improves thermal-hydraulic performance. The existing Zigzag channel has high pressure loss due to flow separation and reverse flow. To improve this disadvantage, partial straight channel is inserted into bended points. Also, the effects of straight channel's length change on heat transfer and pressure loss are analyzed. Thermal-hydraulic performance of the new shape and existing Zigzag channel are quantitatively compared in terms of Goodness Factor. Mass flow rate was changed from $1.41{\times}10^{-4}$ to $2.48{\times}10^{-4}kg/s$. The average volume goodness factor of 1mm straight channel shape was increased by 25% compared to the Zigzag channel.

Cryogenic Performance Test of a Turbopump Inducer (터보펌프 인듀서에 대한 극저온 성능시험)

  • Kim, Jin-Sun;Kim, Jin-Han;Hong, Soon-Sam
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.1
    • /
    • pp.64-70
    • /
    • 2007
  • A test facility was developed where an inducer for a liquid rocket engine turbopump can be tested using liquid nitrogen as a working fluid. At the facility, a hydrodynamic performance test and a cavitation performance test for an oxidizer turbopump were carried out. Head-flow relation at liquid nitrogen test was similar to the case at water test. However, cavitation performance at the liquid nitrogen was superior to the case at water test, which results from the thermodynamic effect of cavitation.

Cryogenic Performance Test of a Turbopump Inducer (터보펌프 인듀서에 대한 극저온 성능시험)

  • Hong Soon-Sam;Kim Jin-Sun;Kim Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.93-99
    • /
    • 2006
  • A test facility was developed where an inducer for a liquid rocket engine turbopump can be tested using liquid nitrogen as a working fluid. At the facility, a hydrodynamic performance test and a cavitation performance test for an oxidizer turbopump were carried out. Head-flow relation at liquid nitrogen test was similar to the case at water test. However, cavitation performance at the liquid nitrogen was superior to the case at water test, which results from the thermodynamic effect of cavitation.

  • PDF

Water Tests of Lox Pump for 75-ton Class Liquid Rocket Engine (75톤급 액체로켓엔진용 산화제펌프의 수류시험)

  • Kim, Dae-Jin;Hong, Soon-Sam;Choi, Chang-Ho;Kim, Jin-Han
    • Aerospace Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.122-128
    • /
    • 2011
  • A series of water tests of a Lox pump for liquid rocket engines are performed at a room temperature. According to the hydraulic test results, the head coefficient is slightly decreased when the rotational speed of the pump is increased. However the efficiency is high at the high-speed test. Also, according to the cavitation test results, the cavitation performance of the pump is found to be decreased when the flow ratio is less than 92%. Furthermore, the vibration characteristic is analyzed using measured high frequency data.

Study of Internal Flow in the supersonic Nozzle by the Hydraulic Analogy (수력학적 상사를 적용한 초음속 노즐 내부 유동 연구)

  • Lee, Ji-Hyung;Lee, Kyung-Hun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.477-482
    • /
    • 2009
  • Though rocket nozzle flow is very important to the rocket performance, the direct measurement is very difficult because of high temperature and high pressure gas flow. Then the experiment utilizing the hydraulic analogy has been developed for such a problem. Supersonic flows through an axisymmetric De Laval nozzle of solid rocket motor was simulated in a 2-D sluice-type water-table designed and manufactured utilizing hydraulic analogy. Methods to minimize or account for non-analogous effects in the hydraulic system must be reviewed for the quantitative application of the hydraulic analogy. In this application the water table is inclined slightly, so that gravity acceleration has a small component in the direction of motion, thus compensating for the effect of friction. Flow visualization leads to better understanding of the analogous system. Within the experimental errors, it is shown that the hydraulic analogy can be used as an effective tool for the study of two dimensional isentropic flows of gases in many fields.

  • PDF