• Title/Summary/Keyword: 수동 검사

Search Result 145, Processing Time 0.027 seconds

Image Correction Method for Segmented Linear Detector (모듈로 구성된 선형 검출기의 영상보정 방법)

  • Chon, Kwon-Su;Oh, Suk-Sim;Jin, Wang-Youn
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.163-168
    • /
    • 2022
  • Linear detectors composed of several modules have been widely used in industrial in-line inspection. Two dimensional image obtained from the linear detector shows line artifact at the connection part of each module. In this study, we proposed a method to remove the line artifact using the flat-field correction and a wedge phantom image. Conventional flat-field correction has been applied to remove the artifact, however there are still line artifacts even after applying correction. It was found that two edge pixels at the connection part of two modules were over-corrected after the flat-field correction. Those edge pixels was corrected by using the correction factor obtained from an image of the wedge phantom, and images removed line artifacts were obtained. It is necessary to improve the method obtained manually the correction factor from the image of the wedge phantom.

Design and Implementation of Early Warning Monitoring System for Cross-border Mining in Open-pit Mines (노천광산의 월경 채굴 조기경보 모니터링시스템의 설계 및 구현)

  • Li Ke;Byung-Won Min
    • Journal of Internet of Things and Convergence
    • /
    • v.10 no.2
    • /
    • pp.25-41
    • /
    • 2024
  • For the scenario of open pit mining, at present, manual periodic verification is mainly carried out in China with the help of video surveillance, which requires continuous investment in labor cost and has poor timeliness. In order to solve this difficult problem of early warning and monitoring, this paper researches a spatialized algorithmic model and designs an early warning system for open-pit mine transboundary mining, which is realized by calculating the coordinate information of the mining and extracting equipments and comparing it with the layer coordinates of the approval range of the mines in real time, so as to realize the determination of the transboundary mining behavior of the mines. By taking the Pingxiang area of Jiangxi Province as the research object, after the field experiment, it shows that the system runs stably and reliably, and verifies that the target tracking accuracy of the system is high, which can effectively improve the early warning capability of the open-pit mines' overstepping the boundary, improve the timeliness and accuracy of mine supervision, and reduce the supervision cost.

Analysis of Factors Related to Pain Relief on Modified Mammography (변형 유방촬영술시 통증완화에 따른 요인 분석)

  • Jang, Myung Mi;Kim, Hwa Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.413-421
    • /
    • 2017
  • Mammography, the basic test for finding and treating increased breast cancer, gives the anxiety of cancer and radiation exposure to most women. In addition, it gave very severe compression pain, so we studied the degree of pain and tried to reduce the pain. The purpose of this study is to compare and analyze the modified imaging technique and the basic imaging technique based on clinical experience, respectively. The subjects of this study were 160 women from 30 to 60 years old who visited to Seoul Boramae Hospital operated by Seoul National University Hospital from February to March 2017 for breast screening. Modified 80 persons and 80 persons were divided into two groups, and each group was asked to fill out questionnaires sequentially without knowing the subjects. The first method is a modified method in which an automatic pedal is divided into four or more presses, a manual pressure is used together, and an attitude is described in detail. Secondly, we used only the automatic pedal compression method and press it within 1-3 times. In the mean of the pain distribution, the experimental group (modified method) was 2.49 and the control group (basic method) had an average of 4.86, which showed 48.8% less pain. In this modified method, the pain scores of the experimental group were lower than those of the control group, and the degree of the pain was statistically significant.

Effects of Cooling on Repeated Muscle Contractions and Tendon Structures in Human (냉각이 반복된 근수축과 사람의 건 구조에 미치는 영향)

  • Chae, Su-Dong;Jung, Myeong-Soo;Horii, Akira
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.6
    • /
    • pp.1-11
    • /
    • 2006
  • Purpose: This study compared the effects of non-cold and cold conditions on the viscoelastic properties of tendon structures in vivo. Methods: Seven male subjects perfomed plantar flesion exercise with maximal isokinetic voluntary contraction, which consisted of muscle contraction for 6 see and relaxation for 60 secs, 10 times for 1 set, Totally 10 sets were repeated. Before and after each task, the elongation of the tendon and aponeurosis of the medial gastrocnemius muscle (MG) was directly measured by ultrasonography. (The relationship between the estimated tendon force and tendon elongation.) Tendon cross-sectional area and ankle joint moment arm were obtained from magnetic resonance imaging (MRI). The tendon force was calculated from the joint moments and the tendon moment arm and stress was obtained by dividing force by cross-sectional areas (CSA). The strain was measured from the displacements normalized to tendon length. Results: After cooling, the tendon force was larger in cold than non-cold. The value of the tendon stiffness of MVC were significantly higher under the cold condition than under the non-cold condition. The maximal strain and stress of $7.4{\pm}0.7%$ and $36.4{\pm}1.8$ MPa in non-cold and $7.8{\pm}8.5%,\;31.8{\pm}1.1$ MPa in cold (P<0.05). Conclusion: This study shows for the first time that the muscle endurance in cooling increases the stiffness and Young's modulus of human tendons. The improvement in muscle endurance with cooling was directly related to muscle and tendon.

  • PDF

Effects of the Symmetric Upper Extremity Motion Trainer on the Motor Function Recovery after Brain Injury: An fMRI Study (뇌손상 후 운동신경기능 회복에 대한 대칭형 상지 운동기구의 효과: 기능적 뇌 자기공명영상 연구)

  • Tae Ki-Sik;Choi Hue-Seok;Song Sung-Jae;Kim Young-Ho
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2005
  • The effect of the developed symmetric upper extremity motion trainer on the cortical activation pattern was investigated in three chronic hemiparetic patients using both fMRI and Fugl-Meyer test. The training program was performed at 1 hr/day, 5 days/week during 6 weeks. Fugl-Meyer tests were performed every two weeks during the training. fMRI was performed at 3T scanner with wrist flexion-extension in two different tasks before and after the training program: the only unaffected hand movement (Task 1) and passive movements of affected hand by the active movement of unaffected hand (Task 2). fMRI studies in Task 1 showed that cortical activations decreased in ipsilateral SMC but increased in contralateral SMC. Task 2 showed cortical reorganizations in bilateral SMC, PMA and SMA. Therefore, it seems that the cortical reorganization in chronic hemiparetic patients can be induced by the training with the developed symmetric upper extremity motion trainer.

  • PDF

Use of music to facilitate verbal and nonverbal expression for older adults in the hospice care (호스피스 환자들의 언어적·비언어적 표현 증진을 위한음악적 활용)

  • Chong, Hyun Ju;Choi, Sung Yoon
    • Journal of Music and Human Behavior
    • /
    • v.2 no.1
    • /
    • pp.35-46
    • /
    • 2005
  • Older adults in the hospice care experience difficulties in expressing their emotional and psychological issues, which has detrimental effect in their well-being. The purpose of this study is to examine how music can be used to facilitate self-expression both verbally and nonverbally in order to decrease negative influences of self-concealment. Four cases were referred from hospice personnel at the hospital, and received music therapy sessions for four month. The total number of session varied from 9 to 11 depending on the conditions of each case. Both qualitative and quantitative data were collected from pre and post test of Self-Concealment Scale and Personal Descriptive Essays. The results indicated that the use of music, especially programed songs were effective in evoking emotional responses with various life-related issues and themes. The posttest indicated that the level of self-concealment has decreased, and also the Personal Descriptive Essays involved increased statements of emotional content after music therapy implementation. The study indicates that music can be used as an significant communicative and expressive medium when working with older adults in the hospice or palliative care, since they experience many difficulties to be engaged in the active expression. Music provide both passive and active experience through listening and participating, and programed music therapy intervention will increase the quality of life through expressive music activities.

  • PDF

The shoulder diagnosis Scapula study of patients who visited the hospital (병원 내원한 환자 견갑골(scapula) 진단을 위한 연구)

  • Ahn, Byeong-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.13-20
    • /
    • 2010
  • True lateral scapula image was very important to diagnosis the scapula fracture and dislocation induced by traumatic injury. The aim of this study was to know the patient rotation angle to be showing the scapula true lateral in korean. d Materials Thirty patients(22men, 8 women, mean ages 53.4)with scapular pain, had supine Anteroposterior projection taken with $30^{\circ}$, $40^{\circ}$, $45^{\circ}$ trunk rotation angle changing the manual angulation material. Radiographs were evaluated independently by 5 experienced observers(1 orthopedics surgery specialist, 1 diagnostic radiology specialist, 3 radiological technologist) They assessed overlap of vertebral border and axillary border of scapula as follows; Totally overlapping of vertebral border and axillary border is 4, partially overlapping is 3, not overlapping is 2 and oblique location with two borders is 1. All observers scored using by PACS monitor.$30^{\circ}$ trunk rotation was scored $1.53{\pm}0.39$, $40^{\circ}$ trunk rotation was scored $3.83{\pm}0.15$ and $45^{\circ}$ trunk rotation was scored $2.17{\pm}0.43$. There was no difference(p<0.05) between group of more than 100cm of the girth of the chest and group of less than 100cm. Similarly, men and women group showed no difference(p<0.05) with trunk rotation statistically. There was no result of trunk rotation angle to radiograph the true scapula lateral image up to date. This studies were summarized as follows; Adaptation of $40^{\circ}$ trunk rotation was the best to show the true scapula lateral image in korean. Our results were very useful to get the true scapula lateral images in clinic.

Development and Assesment of an Embedded Portable A-ABR System (임베디드 기반의 휴대용 A-ABR 시스템 개발 및 평가)

  • Noh, Hyung-Wook;Nam, Ki-Chang;Jang, Kyung-Hwan;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.3
    • /
    • pp.48-55
    • /
    • 2010
  • Hearing impairment is one of the most common birth defects among infants. Significant bilateral hearing impairment have profound effects on speech and language development. But it can be prevented, if a hearing impairment is identified and treated in its early stage. ABR (auditory brainstem response) is useful screening tool for new born hearing test. However, the interpretation of conventional ABR should be done by a experienced audiologist and testing takes some time. Therefore, A-ABR(automated ABR) which detect ABR peak automatically have been developed recently. In contrast to A-ABR researches became active in overseas, there has been little study in Korea. In this study, we have developed a portable A-ABR system based on the results of our previous study. For the evaluation of the developed system, the clinical trials were performed on adults and infants. As a results, it showed good sensitivity (94.4%) and specificity (92.2%), and accuracy (93.0%) between clinical diagnosis and the developed A-ABR test.

Toxic Optic Neuropathy Caused by Chlorfenapyr Poisoning (클로르페나피르 음독 후 발생한 독성 시신경병증 1예)

  • Park, Su Jin;Jung, Jae Uk;Kang, Yong Koo;Chun, Bo Young;Son, Byeong Jae
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1097-1102
    • /
    • 2018
  • Purpose: To report a case of toxic optic neuropathy caused by chlorfenapyr ingestion accompanied by central nervous system involvement. Case summary: A 44-year-old female visited our clinic complaining of reduced visual acuity in both eyes for 7 days. She had ingested a mouthful of chlorfenapyr for a suicide attempt 2 weeks prior to the visit. Gastric lavage was performed immediately after ingestion at the other hospital. Her best-corrected visual acuity was finger count 30 cm in the right eye and hand motion in the left eye. Both pupils were dilated by 5.0 mm and the response to light was sluggish in both eyes. A relative afferent pupillary defect was detected in her left eye. Funduscopy revealed optic disc swelling in both eyes. Magnetic resonance imaging of the brain showed a symmetric hyper-intense signal in the white matter tract including the internal capsule, corpus callosum, middle cerebellar peduncle, and brainstem. The patient was diagnosed with toxic optic neuropathy induced by chlorfenapyr ingestion, and underwent high-dose intravenous corticosteroid pulse therapy. Three days later, the best-corrected visual acuity was no light perception in both eyes. Three months later, optic atrophy was observed in both eyes. Optical coherence tomography revealed a reduction in the thicknesses of the retinal nerve fiber layer and ganglion cell and inner plexiform layer in the macular area. Conclusions: Ingestion of even a small amount of chlorfenapyr can cause severe optic nerve damage through the latent period, despite prompt lavage and high-dose steroid treatment.

Clinical Effects of SJ-002 on URI - Upper Respiratory Tract Infection - (상기도감염증에 대한 SJ-002액의 임상적 고찰)

  • Chung, Byung-Chun;Kim, Kwang-Won;Woo, Un-Joh;Lee, Young-Sunk;Kim, Seung-Woan;Choi, Young-Hwan;Kim, Yeon-Jae;Kim, Sung-Rok;Kim, Soo-Dong
    • The Korean Journal of Pharmacology
    • /
    • v.27 no.2
    • /
    • pp.211-214
    • /
    • 1991
  • SJ-200 is an oral liquid preparation of acetaminophen, ibuprofen, Dl-methyleph edrine HCl, caffeine, chlorpheniramine maleate, guaifenesin and dextromethorphan HBr, which is indicated when there is a need to improve various cold symptoms such as headache, sore throat, fever, or cough etc. Thirty patients was enroled for this study fro June to July, 1991. They were given one bottle (30 ml) of SJ-200 t.i.d dy P.O for an average of one to seven days. 1) Twenty-eight patients (84.8%) were relieved from the symptoms of upper respiratory tract infection. 2) Side effects with this preparation occured in 8 patients924.2%) but in four patients, they were mild, which wee transienty by the discontinuation f the medication.

  • PDF