• 제목/요약/키워드: 수동형 댐퍼

검색결과 16건 처리시간 0.019초

차량용 HDD 의 수동형 진동저감 시스템 설계 (Design of Passive Vibration Attenuation System for a Vehicle HDD)

  • 김진남;김영추;권원태
    • 한국정밀공학회지
    • /
    • 제27권2호
    • /
    • pp.117-122
    • /
    • 2010
  • The shock performance of hard disk drives has been a serious issue for Car PC. Since the vibration and disturbances from a car gives an adverse effect on a HDD of Car PC, it is necessary to protect a HDD from them. In this study, passive vibration attenuation system for a vehicle HDD was developed. Acceleration from the ground through the tire and suspension system was measured to figure out the frequency translated to Car PC. Critical frequency to Car PC was determined by exciting it with a shaker and measuring a data transmitting speed from HDD. A newly designed vibration attenuation system was fabricated to protect HDD from the acceleration. It was shown that the developed system had an excellent vibration attenuation ability.

수동형 압전션트를 이용한 외팔보의 진동저감 연구 (Vibration Reduction of Cantilever using Passive Piezoelectric Shunt)

  • 윤양수;김재철;노희민
    • 한국도시철도학회논문집
    • /
    • 제6권4호
    • /
    • pp.417-426
    • /
    • 2018
  • 압전션트는 구조물의 진동을 저감할 수 있는 전기적인 형태의 댐퍼이다. 구조물의 고유진동수에서 발생한 진동은 구조물에 부착된 압전재료를 통해 전기에너지로 변환된다. 전기에너지는 인덕터와 저항으로 구성된 압전션트를 이용하여 열에너지로 소산시켜 진동을 저감할 수 있다. 본 논문에서는 외팔보의 진동을 저감하기 위하여 필요한 최적 인덕턴스에 대한 수식을 검토하고 유한요소해석과 실험을 이용하여 알루미늄 외팔보의 진동을 저감하였다. 유한요소해석에서는 모드형상과 스트레인에너지 분포를 계산하여 부착위치를 검토하고, 인덕턴스와 저항의 회로값을 조절하여 외팔보의 진동저감량을 계산하였다. 또한, 실험에서는 가변인덕터 모듈을 사용하여 외팔보의 특정주파수에서 발생하는 진동을 저감하였다. 결국, 유한요소해석과 실험의 결과를 토대로 압전션트가 외팔보의 진동을 효과적으로 저감할 수 있음을 검증하였다.

사장교형식 보도교의 보행진동제어를 위한 TMD 적용 (Application of Tuned Mass Damper to Suppress Man-Induced Vibrations of Cable Stayed Foot-bridge)

  • 김윤석;이승우;김재민;장성규
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2011년도 정기 학술발표대회
    • /
    • pp.74-74
    • /
    • 2011
  • 본 연구에서는 중앙경간 54m, 교폭 4m의 사장교형식의 보도교로 측경간은 계단으로 이루어진 1경간 케이블교량을 대상으로 보행하중에 의한 수직진동을 제어하기 위해 제진장치(TMD)를 적용하기로 하고 실물 TMD의 설계 및 제작 그리고 설치 및 제어성능실험을 수행하였다. 우선 사장교형식의 교량. 그리고 1경간 교량이라는 점에서 상대적으로 감쇠율이 낮을 것으로 예측되었고 또한 54m의 경간장이 보행자가 가진 주파수에 근접한 고유진동수를 나타낼 것으로 사료되어 Eurocode 2 part 2(EC5-2)의 규준에 따라 1인 및 다수 보행하중에 의한 보도교의 발생가속도를 산출하였다. 이 경우 최대가속도는 다수의 보행자가 연속적으로 진행할 때 발생하였으며, 수직방향의 가속도가 사용성기준을 초과하는 것으로 나타났다. 또한 구조해석프로그램에 의한 고유치 해석결과, 보행하중의 주파수대역내에 진동모드가 존재하는 것으로 나타났다. 따라서 본 교량의 설계단계에 있어서 보행진동을 제어하기 위하여 유지관리가 용이한 수동형의 동조질량감쇠장치(Tuned Mass Damper)를 적용하기로 하였으며 TMD의 설계에서는 TMD의 제어목표를 만족시킬 수 있는 TMD의 가동질량(moving mass)을 우선적으로 결정하였고, 이로부터 Den Hartog의 제안식에 따라 TMD의 고유진동수비, 유효감쇠비를 산정하였다. 산정된 변수들을 이용하여 설계된 TMD는 현장설치 및 튜닝의 편의성을 고려하여 수평 외팔보형식으로 설계, 제작되었으며 제작된 TMD의 경우 회전축에 대해 질량, 스프링, 댐퍼의 중심거리를 조정함으로써 TMD의 진동수, 강성, 감쇠력을 상대적으로 매우 용이하게 조절할 수 있으며, 조정범위 또한 광범위하여 일반 TMD에 비해 현장설치시 대상구조물에 동조시키기가 용이하며, 작동시 마찰감쇠가 거의 없다는 장점이 있다. 현장설치전에 제작된 TMD를 대상으로 자유진동 시험을 통하여 질량의 중심거리, 스프링 크기 그리고 댐퍼의 설치유무를 각각 변화시키며 TMD의 자유진동 데이터를 취득하였다. 각각의 시험에서 얻어진 데이터로부터 스펙트럼해석을 통하여 고유진동수를 구하였고, 자유진동 파형으로 부터 감쇠비를 구하였다. TMD는 일반적으로 제어모드의 변형형상이 가장 큰 곳에 설치되었을 때 최대의 제진효과를 발휘할 수 있다. 그러나 현장여건상 설치가 불가능하거나 미관을 해치는 경우에는 가능한 범위 내에서 TMD 제어효율이 가장 크게 발휘할 수 있는 곳을 선택하여야 한다. 본 보도교의 경우, 중앙경간 중심부에서 가장 큰 모드변형형상을 나타내지만, 보도교의 상판 연결부 등에 따른 TMD 시공문제로 인하여 TMD 설치위치는 교량 중앙에서 양 방향으로 1.25m 떨어진 곳에 대칭으로 총 2기를 설치하기로 하였다. 일반적으로 TMD의 모든 설계변수는 구조물의 설계단계에서 수행된 구조해석결과에 근거하여 설정하므로 완공된 구조물, 즉 실제보도교의 동적특성을 계측하여 정확하게 진동수를 튜닝하여야 한다. 구조해석에 의한 보도교의 수직방향(TMD 작동방향) 고유진동수는 1.5225 Hz이며, 감쇠비는 규준에 의하여 0.6 %로 가정하였다. 그러나 이 값들은 구조해석모델 및 재료적 특성과 시공상의 오차에 의하여 실제와 다를 수 있으므로 현장계측에 의한 확인이 요구된다. 또한 TMD의 제진효율이 설계시의 목표대로 확보되었는지도 확인해야 하므로 현장튜닝 및 성능시험을 실시하였다. 보도교의 가진은 사전에 실시한 상시 미진동계측결과를 토대로 2Hz를 목표로 하여 인력가진실험을 수행하였고, 탁월진동 주파수는 1.9896Hz로 나타나 구조해석결과와 오차가 있음을 알 수 있다. 가진실험결과를 토대로 TMD의 진동수를 최적진동수비로 튜닝하고 인력가진 실험을 다시 실시하여 TMD의 진동제어성능을 검토하였다. TMD 튜닝 전, 후의 보도교 감쇠비를 비교한 결과, TMD를 설치함으로써 약 4.218%의 감쇠비 증가가 있음을 알 수 있다.

  • PDF

수동형 댐퍼를 장착한 구조물의 동적응답기반 신뢰성 해석 - 제2편: 시스템 파괴확률 산정 (Dynamic Response based System Reliability Analysis of Structure with Passive Damper - Part 2: Assessment of System Failure Probability)

  • 김승민;옥승용
    • 한국안전학회지
    • /
    • 제31권5호
    • /
    • pp.95-101
    • /
    • 2016
  • This study proposes a multi-scale dynamic system reliability analysis of control system as a method of quantitative evaluation of its performance in probabilistic terms. In this second paper, we discuss the control effect of the viscous damper on the seismic performance of the structure-level failure. Since the failure of one structural member does not necessarily cause the collapse of the structural system, we need to consider a set of failure scenarios of the structural system and compute the sum of the failure probabilities of the failure scenarios where the statistical dependence between the failure scenarios should be taken into account. Therefore, this computation requires additional system reliability analysis. As a result, the proposed approach takes a hierarchial framework where the failure probability of a structural member is computed using a lower-scale system reliability with the union set of time-sequential member failures and their statistical dependence, and the failure probability of the structural system is again computed using a higher-scale system reliability with the member failure probabilities obtained by the lower-scale system reliability and their statistical dependence. Numerical results demonstrate that the proposed approach can provide an accurate and stable reliability assessment of the control performance of the viscous damper system on the system failure. Also, the parametric study of damper capacity on the seismic performance has been performed to demonstrate the applicability of the proposed approach through the probabilistic assessment of the seismic performance improvement of the damper system.

수동형 댐퍼를 장착한 구조물의 동적응답기반 신뢰성 해석 - 제1편: 부재별 파괴확률 산정 (Dynamic Response based Reliability Analysis of Structure with Passive Damper - Part 1: Assessment of Member Failure Probability)

  • 김승민;옥승용
    • 한국안전학회지
    • /
    • 제31권4호
    • /
    • pp.90-96
    • /
    • 2016
  • This study proposes a dynamic reliability analysis of control system as a method of quantitative evaluation of its performance in probabilistic terms. In this dynamic reliability analysis, the failure event is defined as an event that the dynamic response of the structural system exceeds a displacement limit, whereas the conventional reliability analysis method has limitations that do not properly assess the actual time history response of the structure subjected to dynamic loads, such as earthquakes and high winds, by taking the static response into account in the failure event. In this first paper, we discuss the control effect of the viscous damper on the seismic performance of the member-level failure where the failure event of the structural member consists of the union set of time-sequential member failures during the earthquake excitations and the failure probability of the earthquake-excited structural member is computed using system reliability approach to consider the statistical dependence of member failures between the subsequent time points. Numerical results demonstrate that the proposed approach can present a reliable assessment of the control performance of the viscous damper system in comparison with MCS method. The most important advantage of the proposed approach can provide us more accurate estimate of failure probability of the structural control system by using the actual time-history responses obtained by dynamic response analysis.

고댐핑 요크 구조 적용 대형 태양전지판의 수동형 제진에 관한 연구 (A Study on the Passive Vibration Control of Large Scale Solar Array with High Damping Yoke Structure)

  • 박재현;박연혁;박성우;강수진;오현웅
    • 항공우주시스템공학회지
    • /
    • 제16권5호
    • /
    • pp.1-7
    • /
    • 2022
  • 최근 인공위성 임무 고도화에 따라 고성능의 전장품이 탑재되어 시스템 소요전력이 증가되고 있다. 이에 따라 충분한 전력확보를 위하여 태양전지판 크기 또한 점차 증가하고 있다. 태양전지판의 크기 증가 및 중량화는 위성체 자세 기동 시 발생하는 진동과의 커플링 등에 의해 태양전지판 탄성 진동의 크기 증가를 유발한다. 상기 진동은 힌지 및 요크를 통해 위성체에 전달되어 지향성능이 요구되는 고정밀 관측위성의 지향성능과 직결되어 고해상도 영상 획득 임무 성능을 저하시킨다. 종래에는 태양전지판의 탄성 진동을 저감시키고자 고강도 설계에 집중 또는 별도의 보강재 및 댐퍼 시스템을 적용하였다. 그러나, 이는 부피 및 무게를 증가시키며 시스템 복잡성이 증가하는 한계점이 존재한다. 본 연구에서는 상기 한계점을 극복하고자 초탄성 형상기억합금(SMA: Shape Memory Alloy) 양면에 점탄성 테이프로 박막층을 적층함으로써 댐핑 특성을 극대화하였으며, 별도 시스템 적용없이 작은 부피 및 무게로 진동을 저감하여 시스템 경량화에 기여할 수 있는 설계기법을 제안하였다. 제안한 초탄성 SMA 적층형 태양전지판 요크를 태양전지판 더미에 적용시켜 자유감쇠시험 및 온도시험을 통해 설계 유효성을 입증하였다.