• Title/Summary/Keyword: 수동형

Search Result 457, Processing Time 0.023 seconds

A Construction Scheme of Next Generation Wire Communication System by using Long-reach WDM-PON (장거리 전송 파장분할 다중방식 수동형 광가입자망을 이용한 차세대 국방 유선통신체계 구축방안)

  • Kim, Min-Hwan;Lee, Sang-Mook;Lee, Chang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.90-99
    • /
    • 2007
  • We demonstrate an 80km-reach 64-channel DWDM-PON based on wavelength-locked F-P LDs by changing the position of the C-band BLS for upstream channels from the CO to the RN. It mitigates the necessity of the high power C-band BLS and its handling problems. It also reduces back scattering induced penalty. We obtained less than $10^{-6}$ PLRs in all 128channels through 80km SMF. We also demonstrate a 240km-reach DWDM-PON based on wavelength-locked F-P LDs by adding a bidirectional erbium-doped fiber amplifier(EDFA). We show packet-loss-free transmission in all 128channels at 125 Mb/s per channel over 240km SMF We report the detuning effect of arrayed waveguide gratings(AWGs) and crosstalk effect in the implemented system. We Propose an architecture of a next generation defense wire communication system with the demonstrated long-reach DWDM-PON.

PIMD Performance Test of Active Baseband Antenna (능동형 기지국안테나의 PIMD 특성분석)

  • Kim, Jae-Hak;Jung, Young-Bae
    • Journal of IKEEE
    • /
    • v.17 no.2
    • /
    • pp.163-167
    • /
    • 2013
  • As the mobile services have been increased, the interference of the neighboring base stations is increased and the PIMD(Passive Inter-Modulation Distortion) has been a main issue for the design of base station antenna systems. In this paper, it is proposed the PIMD test method for the active basestation antenna whose radiators are directly connected with main active parts including amplifiers, and we presents its test results using a developed active basestation antenna. From the results, the active basestation antenna has the better PIMD performance than conventional passive structure by 8.4dB. The proposed PIMD test method can be used to get the accurate PIMD test result because the test environment is very similar with real basestation.

Performance of a Passive Ranging by Using Dual Focused Beamformers (이중 초점 빔 형성기를 사용한 수동형 거리 추정 기법의 성능)

  • 김준환;양인식;김기만;오원천;김인익;천승용
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.52-57
    • /
    • 2001
  • The passive ranging estimation techniques using a focused beamformer have been studied under the water. It is well known that the passive ranging estimation method using a focused beamformer is excellently evaluated. Among these, the passive ranging sonar is known to have a good performance under low signal-to-noise. ratio. However, its performance is degraded in multi-source environments. In this paper, we proposed the technique using dual focused beamformers to estimate the range. And when the sampling frequency is low, it is very difficult to steer the focused beam to the desired direction, as a result of this, the low performance occurs because of a distorted beam pattern. In this paper, we study the effect of sampling rate on passive ranging by using focused beamformer. And we verified the performance of the proposed method via computer simulation.

  • PDF

Performance Improvement in Passive Tag Based RFID Reader (수동형 태그 기반 RFID 리더기의 성능 개선)

  • Rhee, Seung-Hak;Chun, Jong-Hun;Park, Jong-An
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.11A
    • /
    • pp.1159-1166
    • /
    • 2006
  • In this paper, we have designed a RFID reader receiver system for improving the performance of the passive Tag based 9$'908.5{\sim}914MHz'$ RFID reader, and analyzed the system performance according to the frequency, the reader, and tag properties. The commercial receive system causes a loss in sensitivity because of 24 capacitors and 6 inductors. So we have designed an improved system using a circulator, LNA and a SAW filter. The experimental results show that the use of a circulator to separate the Tx/Rx paths eliminates interference, the LNA improves the sensitivity of the Rx module and SAW filter eliminates the noise and spurious components in the received signal.

A study on Real-time Graphic User Interface for Hidden Target Segmentation (은닉표적의 분할을 위한 실시간 Graphic User Interface 구현에 관한 연구)

  • Yeom, Seokwon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.17 no.2
    • /
    • pp.67-70
    • /
    • 2016
  • This paper discusses a graphic user interface(GUI) for the concealed target segmentation. The human subject hiding a metal gun is captured by the passive millimeter wave(MMW) imaging system. The imaging system operates on the regime of 8 mm wavelength. The MMW image is analyzed by the multi-level segmentation to segment and identify a concealed weapon under clothing. The histogram of the passive MMW image is modeled with the Gaussian mixture distribution. LBG vector quantization(VQ) and expectation and maximization(EM) algorithms are sequentially applied to segment the body and the object area. In the experiment, the GUI is implemented by the MFC(Microsoft Foundation Class) and the OpenCV(Computer Vision) libraries and tested in real-time showing the efficiency of the system.

Measurement of excitation efficiency and passively Q-switched characteristics of laser diode end-pumped Nd:YAG laser by using $Cr^{4+}$:YAG as a saturable absorber ($Cr^{4+}$:YAG 포화 흡수체를 이용한 레이저 다이오드 뒷면 여기 Nd:YAG 레이저의 들뜸 효율 및 Q-switching 특성 연구)

  • 정태문;김광석;문희종;이종훈;김철중;이종민
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.4
    • /
    • pp.231-235
    • /
    • 1998
  • Passively Q-switched, laser diode(LD) end-pumped Nd:YAG laser was demonstrated by using $Cr^{4+}$:YAG as a saturable absorber. In addition , we could calculate an excitation efficiency, which is an important parameter to evaluate the pumping geometry, directly by measuring the absorbed power in Nd:YAG at threshold condition. We found that output parameters such as average power, pulse duration, and repetition rate strongly depended on the low intensity transmission of $Cr^{4+}$:YAG and driving current of lase diode. The maximum Q-switched output power of 1 W was obtained with 40 kHz repetition rate. The pulse duration was varied from 50 ns to 200 ns.

  • PDF

An Experimental Study on the Structural Vibration Control Using Semi-Active Orificed Fluid Dampers (반능동형 오리피스 유체댐퍼를 이용한 구조물 진동제어에 관한 실험적 연구)

  • 문석준;김병현;정종안
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.2
    • /
    • pp.55-62
    • /
    • 2004
  • In general, control performance of the active control system is superior to that of the passive control devices. However, the active system require a large amount of external energy to operate the actuators. Semi-active control systems maintain the reliability of the passive control systems while taking advantage of the adjustability of the active control system. In this research, a semi-active orificed fluid damper having the capacity of about 2 tons was designed and fabricated. It is a two-stage damper with normally open solenoid valve. A series of tests was performed to grasp its performance characteristics. It was also applied to a 6-story steel structure subjected to random and seismic excitations for the confirmation of its validity on structural vibration absorption.

Radiometric Calibration of FTIR Spectrometer For Passive Remote Sensing Application (수동형 원격탐지 FTIR 분광계의 Radiometric Calibration)

  • Kim, Dae-Sung;Park, Do-Hyun;Choi, Seung-Ki;Ra, Sung-Woong
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.391-395
    • /
    • 2006
  • In this paper, radiometric calibration of a FTIR spectrometer for passive remote sensing application was introduced and verified. Radiometric calibration is a significant signal processing procedure to retrieve the object radiance from the measured spectrum. The object radiance is measured and registered distorted by the detector's responsivity dependent on wavelength and instrument self-emission. Radiance of two temperature points, hot temperature and cold temperature, from a well-controlled blackbody was measured and used to obtain the scale factor and offset factor which are required for radiometric calibration. For gas phase C2H5OH. radiometric calibration was done and verified through comparison of its emission line width and intensity with the standard spectrum.

Design of the control Algorithm for Improvement of the Convenience the Active-type Walking Aid (전동 보행보조기의 편의성 향상을 위한 제어기 설계)

  • Lee, D.K.;Kong, J.S.;Goh, M.S.;Kang, S.J.;Lee, S.M.;Lee, E.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.17-25
    • /
    • 2011
  • This paper aims to find the optimal control gain for enhancing the convenience of electric walking frames and design a control algorithm. With the recent advances in medical technology, there has been a rapid increase in the aging population and a variety of mobile walking frames have been developed for improvement of the quality of life. However, the manual walking frames of such mobile aids don't have any electric motor which helps facilitate elderly users' walking and thus are not efficient enough for the old people of weak strength to use especially when moving on uneven surfaces such as slopes or thresholds. The types of electric walking frames have been developed to overcome such inefficiency. Electric walking frames require users' control operations for motor driving unlike manual frames. Therefore, when they are not properly handled, it causes considerable inconvenience to their users. The present study compared the electric walking frames with manual ones in terms of operational convenience and attempted to improve the user convenience of walking frames varying the control value for user convenience based on certain standards. This paper presented a haptic sensor designed to recognize the will to walk and measure the degree of convenience and proposed a control algorithm for improvement of convenience. For user convenience, this paper evaluated the relative convenience of walking frames in view of changing differences between the center of vehicle (COV) and the center of position (COP). With the employment of an electric walking frame and a new measuring method, all the processes were experimentally tested and validated.

Dual-band RFID Tag Antenna Applicable for RF Power Harvester System (RF 에너지 충전 시스템 기능을 위한 이중대역 RFID 태그 안테나)

  • Mun, Byeonggwi;Rhee, Changyong;Kim, Jae-Sik;Cha, Junghoon;Lee, Byungje
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.5
    • /
    • pp.46-51
    • /
    • 2013
  • In this paper, a dual-band antenna is proposed for the RF power harvester system as well as RFID tag. The proposed antenna operates as the passive and active RFID tag antenna in the UHF and microwave band, respectively. In addition, to charge the battery of an active RFID tag in the microwave band, it harvest the RF signal for tagging from the passive RFID tag antenna in the UHF band. The proposed antenna operates in the UHF band (917~923.5 MHz) and microwave band (2.4~2.45 GHz). In order to obtain the dual-band operation, the dipole structure and meander parasitic elements are proposed as the ${\lambda}/2$ and $1{\lambda}$ dipole antenna, respectively. The radiating dipole structure in the microwave band acts as the coupled feed for the meander parasitic elements in the UHF band. The impedance bandwidth (VSWR < 2) of the proposed antenna covers 917~923.5 MHz (UHF band) and 2.4~2.45 GHz (Microwave band). Measured total efficiencies are over 45 % in the UHF band and over 70 % in the microwave band. Peak gains are over 0.18 dBi and 2.8 dBi in the UHF and microwave band with an omni-directional radiation pattern, respectively.