Characteristics of noise in HVAC duct for vehicle (차량용 공조덕트의 소음특성에 관한 연구)

  • Kim, Jae-Won;Kim, Jin-Min;Park, Jeong-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.529-534
    • /
    • 2003
  • Comprehensive study on the system, including blower and ducts, of HVAC device of a vehicle has been carried out for improvements of noise characteristics. The parameters of design improvements are concerned with geometric informations such as the shape of ducts and presence of a windshield window. Test results show that noise level increasing the following order: HV (HD) < V (D) < BH ${\sim}$ BHV (BHD) < B (B, H, V, D denote for blower, heater unit, vent duct, defrost duct, respectively). The effects of windshield glass on the noise level in the case of defrost mode are pronounced and the effects of the geometry of ducts on the overall HVAC noise prove to be not small.

  • PDF

Vibration Reduction of an Air Cooled Heat Exchanger with Axial Flow Fan (축류송풍기 부착형 공냉식 열교환기의 진동 저감)

  • Jung, Goo-Choong;Choi, Yeon-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.75-81
    • /
    • 2000
  • Vibration problems induced by an air cooled heat exchanger with axial flow fan were investigated during the operation of a petrochemical plant. Two different studies were done; one was experimental field test and the other was theoretical verification. To find main cause of the blade passing frequency of the fan after installing additional blockage board at the air inlet of the axial fan, the frequency spectrum was measured. The vibrations of the blade passing frequency became higher. The natural frequency of driving support of the heat exchanger was theoretically calculated. It was approximately equal to the blade passing frequency. During the normal operation of the plant, it was impossible to modify the structure of the driving support. Instead, the blade number was increased to reduce vibration level. It increased the ratio of the forcing frequency to the natural frequency of the driving support over the resonance region.

  • PDF

A Study on Design and Manufacture of Slotless Outer Rotor BLDC Motor for a Vehicle Blower (자동차 송풍장치용 Slotless Outer Rotor BLDC 모터 설계 및 제작에 관한 연구)

  • Hyon-Jang Lee;Hee-Seok Jeong;Sun-Ho Cho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.5
    • /
    • pp.827-834
    • /
    • 2023
  • In this paper, a slotless outer rotor BLDC motor for a vehicle blower was designed and manufactured to improve the disadvantages of general motors. The proposed motor solves the noise caused by mechanical friction of DC motor during rotation by removing the brush, Also, slotless air-gap windings are used to improve cogging torque by BLDC motor slots. Then, the motor has a structure in which a magnet is attached to the external rotor and rotates simultaneously with the internal rotor, there is no change in magnetic flux. Therefore, it has high efficiency by fundamentally reducing iron loss.

A Study on the Effect of Sweep Angle of Axial Fan on Its Noise (축류송풍기의 스윕각이 소음에 미치는 영향에 대한 연구)

  • Choi, Jae-Ho;Kim, Kwang-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.365-370
    • /
    • 2000
  • A computational study on the effect of sweep angle of axial fan on its noise is performed in the present paper. The forward swept axial fan was designed by numerical optimization method incorporated with three dimensional flow analysis. The objective function was defined by the ratio of generation rate of turbulent kinetic energy to pressure head. And, two variables related with sweep angle distribution are used for design variables. The swept fan has better performance characteristics and noise level. The experimental result shows that spectrums of no-sweet and swept fans have differences in the blade passage frequency, especially in the broadband. And the overall noise level of swept fan is lower 10dB(A) than that of no-sweep fan. For the comparison of flow fields between no-sweep fan and swept fan, CFX-TASCflow computational fluid dynamics software is used. Standard k-${\varepsilon}$ model is used for the turbulence model. Distributions of pressure and turbulent kinetic energy distributions are compared in order to find what happen in the low-noise swept fan.

  • PDF

Acoustical Similarity for Small Cooling Fans Revisited (소형 송풍기 소음의 음향학적 상사성에 관한 연구)

  • 김용철;진성훈;이승배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.196-201
    • /
    • 1995
  • The broadband and discrete sources of sound in small cooling fans of propeller type and centrifugal type were investigated to understand the turbulent vortex structures from many bladed fans using ANSI test plenum for small air-moving devices (AMDs). The noise measurement method uses the plenum as a test apparatus to determine the acoustic source spectral density function at each operating conditions similar to real engineering applications based on acoustic similarity laws. The characteristics of fans including the head rise vs. volumetric flow rate performance were measured using a performance test facility. The sound power spectrum is decomposed into two non-dimensional functions: an acoustic source spectral distribution function F(St,.phi.) and an acoustic system response function G(He,.phi.) where St, He, and .phi. are the Strouhal number, the Helmholtz number, and the volumetric flow rate coefficient, respectively. The autospectra of radiated noise measurements for the fan operating at several volumetric flow rates,.phi., are analyzed using acoustical similarity. The rotating stall in the small propeller fan with a bell-mouth guided is mainly due to a leading edge separation. It creates a blockage in the passage and the reduction in the flow rate. The sound power levels with respect to the rotational speeds were measured to reveal the mechanisms of stall and/or surge for different loading conditions and geometries, for example, fans installed with a impinging plate. Lee and Meecham (1993) studied the effect of the large-scale motions like impinging normally on a flat plate using Large-Eddy Simulation(LES) and Lighthill's analogy.[ASME Winter Annual Meeting 1993, 93-WA/NCA-22]. The dipole and quadrupole sources in the fans tested are shown closely related to the vortex structures involved using cross-correlations of the hot-wire and microphone signals.

  • PDF

An Experimental Study on the Effects of Non-uniform Inlet Flows upon Tonal Radiation from an Axial-type Propeller Fan (불균일 난류 유입유동이 프로펠러형 송풍기의 톤소음에 미치는 영향에 대한 실험적 연구)

  • Lee, Seungbae;Kim, Kwang-Yong;Yang, Gwi-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.1 no.1 s.1
    • /
    • pp.49-57
    • /
    • 1998
  • The acoustic signatures from a propeller fan under non-uniform inlet flow conditions were measured to reveal the mechanism for tonal radiation. Experimental studies were carried out by generating non-uniform turbulent flows with circumferential and radial components of harmonic incoming gust deliberately. This paper reports the measured acoustic power exponents and cross-spectra for circumferential and radial disturbances at a specified flow-rate coefficient.

  • PDF

Development of Standard Series for Turbo Blowers (터보 블로워 표준화 제품 개발 사례)

  • Song, Kween;Kim, Kwang-Ho;Kim, Shin Hyoung;Kim, Hwe-Ryong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.99-103
    • /
    • 2000
  • This paper describes the development of standard series for turbo blowers. In mass production system, it is very required to standardize blowers to improve the productivity of ordering, estimating, manufacturing. To standardize blowers, we performed researches on the effects of $b_1$(impeller inlet width), $b_2$(impeller outlet width), ${\beta}_1$(blade inlet angle), ${\beta}_2$(blade outlet angle), Z(number of blades) of impellers and geometry of casing experimentally. Through this study, we chose the several best model of turbo blowers with high efficiency and low noise, which represent each specific speed series 63, 80, 100, 125, 160, 200, 250, 315. After the development of such standardized blowers, the test results are used to prepare the fan geometry and performance database for a selection software.

  • PDF

Development of Decompressed Dryer for Mushroom (버섯의 감압건조기 개발)

  • 김영민;김유호;조영길;최희석;조광환
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.07a
    • /
    • pp.267-272
    • /
    • 2003
  • 본 연구에서는 버섯의 건조시간을 줄여 건조 후 버섯의 품질을 향상시키기 위하여 버섯의 감압건조기를 개발하였으며 연구 결과는 다음과 같다. 가. 버섯의 감압건조기의 시작기를 제작하였고, 시작기의 구조는 건조실, 감압블로워, 흡ㆍ배기구 솔레노이드 밸브, 제습장치, 송풍기, 전기히터로 구성되어 있으며, 건조실의 내부 압력이 표준대기압-900hPa, 열풍온도는 상온에서 5$0^{\circ}C$까지 조절할 수 있도록 제작하였다. 나. 시작기를 이용하여 표고버섯을 대상으로 건조특성시험을 실시한 결과, 열풍온도 5$0^{\circ}C$, 건조실 내부압력 900-940hPa에서 건조시간은 11.5h으로 대기압과 비교하여 6.5h 단축되는 것으로 나타났다. 또한, 건조 전ㆍ후의 색차, 수축률, 복원률의 품위가 우수한 것으로 나타났으며 F-test 유의성 검증 결과, 5%의 유의수준에서 갓주름의 색차, 갓직경의 수축률, 복원률에서 유의차가 있는 것으로 나타났다. 다. 열풍온도 5$0^{\circ}C$, 건조실 내부압력 900-940hPa로 표고버섯과 아가리쿠스에 대하여 건조성능시험을 실시한 결과, 표고버섯의 경우 건조시간은 13h으로 열풍식 농산물 건조기와 비교하여 건조시간이 4.5h 단축되는 것으로 나타났으며, 아가리쿠스의 경우 건조시간이 17.5h로 나타났다. 라. 성능시험 결과, 시작기가 열풍식 농산물건조기와 비교하여 건감률, 색택, 수축률, 복원률 등의 품위가 전반적으로 우수한 것으로 나타났다. 마. 시작기의 건조비용을 분석한 결과, 건조시간은 단축되었지만 시설투자비가 높아 건조비용이 표고버섯의 경우 2,461원/kg으로 열풍식 농산물건조기 보다 13% 높은 것으로 나타났지만, 추후 고품질 건조버섯 생산을 위한 기초자료로 활용이 가능할 것으로 판단된다.라갈수록 낮은 온도분포를 나타내고 있는 것은 상부에는 외부공기가 유입되면서 온도가 떨어지는 반면 하부에는 외부공기 유입이 적기 때문으로 사료된다. 또한 열풍실의 길이방향 위치별 온도 분포에서도 같은 현상으로 나타났고, 버너쪽과 송풍기쪽의 온도편차는 나타나지 않아 균일 건조를 기대할 수 있다. 마. 열풍온도를 45$^{\circ}C$로 설정하고 조사거리와 방사체 길이를 각각 119, 1,470mm로 하여 벼의 건조성능시험을 열풍건조기(대비구)와 비교시험 결과 시험구에서 건감률, 건조소요에너지가 각각 0.58%(w.b.), 470kcal/kg - water로 대비구보다 각각 건감율은 23% 높았고, 건조소요에너지는 2%의 절감되었다. 바. 건조기에서 발생되는 소음은 버너쪽 근처에서는 대비구 94.12㏈의 87%에 불과하였으나, 거리가 멀어질수록 차이는 크지 않았다. 이것은 버너에서 멀어질수록 외부적인 요인이 소음에 영향을 미쳤기 때문인 것으로 생각된다. 사. 시작기와 대비구간의 경제성에서 시작기의 구입가격이 20% 비싸기 때문에 시간당 고정비가 높았으나, 건조성능이 우수하여 건조비용이 69,350원/톤으로 대비구보다 14% 절감되는 것으로 나타났다.작용하는 것으로 사료된다.된다.정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을 전도성 물질로 증착시키지 않고, Silver Paint 에 시편을 접착하는 방법으로도 만족한 시험 결과를 얻을 수 있었다.째, 회복기 중에 일어나는 입자들의 유입은 자기폭풍의 지속시간을 연장시키는 경향을 보이며 큰 자기폭풍일수록 현저했다. 주상에서 관측된 이러한 특성은 서브스톰 확장기 활동이 자기폭풍의 발달과 밀접한 관계가 있음을 시사한다.se that were all

  • PDF

Study on the Characteristics of Far Infrared Ray Drying for Rough Rice(III) - Performance test of far infrared ray dryer - (벼의 원적외선 건조특성에 관한 연구(III) 원적외선 건조기 성능시험)

  • 김유호;조영길;조광환;이선호;김영민;한충수;금동혁;한종규
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.07a
    • /
    • pp.213-219
    • /
    • 2003
  • 본 연구에서는 새로운 개념의 건조방법을 연구하여 곡물건조의 변화를 도모하고자 원적외선ㆍ열풍 복합열을 이용한 곡물건조기를 개발하게 되었다. 그 결과를 요약하면 다음과 같다. 가. 방사체길이가 1,680mm일 때 보다 1,470mm일 때가 방사체 표면온도가 높게 나타났고, 안정적인 것으로 나타났다. 열풍온도를 5$0^{\circ}C$로 설정했을 때 방사체의 표면온도분포는 280-29$0^{\circ}C$을 유지하였고, 6$0^{\circ}C$일 때는 30$0^{\circ}C$ 부근에서 유지되는 것을 확인할 수 있었다. 두 조건 모두에서 온도편차는 크게 나타나지 않았으므로 균일 건조가 이루어지는 것을 의미하며, 곡물의 품질저하에 영향을 미치지 않는 것으로 판단된다. 나. 열풍온도 5$0^{\circ}C$, 조사거리 125mm, 방사체 길이 1,470mm에서 방사체 길이방향으로 위치에 따라서 온도편차를 측정했을 때 버너를 기점으로 해서 근거리에서부터 원거리까지 균등 분할하여 5점의 온도를 측정하여 그 변화곡선을 분석한 결과 위치 3에서 온도가 높았고, 계속해서 위치 4, 5, 2, 1순으로 나타났다. 버너의 근거리에서보다 원거리에서 온도가 높게 나타난 것은 원적외선방사체를 통과하는 열풍이 빠져나가도록 되어있는 열풍유동관이 버너 원거리에 위치하고 있어 버너에 불꽃이 점화되면서 열풍이 방사체 끝쪽으로 유동되기 때문이다. 다. 건조실 수직면 길이방향의 온도는 열풍공기가 열풍실에서 유입되는 하단부이 온도가 높게 나타났고, 버너쪽과 송풍기쪽의 온도차는 나타나지 않아 온도분포의 좌우 대칭이 잘 되어 균일 건조가 되는 것으로 판단된다 이러한 현상은 건조실의 수평면에 대해서도 같은 현상이 나타났다. 라. 바닥면에서 상부로 올라갈수록 낮은 온도분포를 나타내고 있는 것은 상부에는 외부공기가 유입되면서 온도가 떨어지는 반면 하부에는 외부공기 유입이 적기 때문으로 사료된다. 또한 열풍실의 길이방향 위치별 온도 분포에서도 같은 현상으로 나타났고, 버너쪽과 송풍기쪽의 온도편차는 나타나지 않아 균일 건조를 기대할 수 있다. 마. 열풍온도를 45$^{\circ}C$로 설정하고 조사거리와 방사체 길이를 각각 119, 1,470mm로 하여 벼의 건조성능시험을 열풍건조기(대비구)와 비교시험 결과 시험구에서 건감률, 건조소요에너지가 각각 0.58%(w.b.), 470kcal/kg - water로 대비구보다 각각 건감율은 23% 높았고, 건조소요에너지는 2%의 절감되었다. 바. 건조기에서 발생되는 소음은 버너쪽 근처에서는 대비구 94.12㏈의 87%에 불과하였으나, 거리가 멀어질수록 차이는 크지 않았다. 이것은 버너에서 멀어질수록 외부적인 요인이 소음에 영향을 미쳤기 때문인 것으로 생각된다. 사. 시작기와 대비구간의 경제성에서 시작기의 구입가격이 20% 비싸기 때문에 시간당 고정비가 높았으나, 건조성능이 우수하여 건조비용이 69,350원/톤으로 대비구보다 14% 절감되는 것으로 나타났다.

  • PDF

Development of An Integrated Optimal Design Program for Design of A High-Efficiency Low-Noise Regenerative Fan (재생형 송풍기의 고효율 저소음 설계를 위한 통합형 최적설계 프로그램 개발)

  • Heo, Man-Woong;Kim, Jin-Hyuk;Seo, Tae-Wan;Koo, Gyoung-Wan;Lee, Chung-Suk;Kim, Kwang-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.1
    • /
    • pp.35-40
    • /
    • 2014
  • A multi-objective optimization of a regenerative fan for enhancing the aerodynamic and aeroacoustic performance was carried out using an integrated fan design system, namely, Total FAN-Regen$^{(R)}$. The Total FAN-Regen$^{(R)}$ was developed for non-specialists to carry out a series of design process, viz., computational preliminary design, three-dimensional aerodynamic and aeroacoustic analyses, and design optimization, for a regenerative fan. An aerodynamic analysis of the regenerative fan was conducted by solving three-dimensional Reynolds-averaged Navier-Stokes equations using the shear stress transport turbulence model. And, an aeroacoustic analysis of the regenerative fan was implemented in a finite/infinite element method by solving the variational formulation of Lighthill's analogy based on the results of the unsteady flow analysis. An optimum shape obtained by Total FAN-Regen$^{(R)}$ shows the enhanced efficiency and decreased sound pressure level as much as 1.5 % and 20.0 dB, respectively, compared to those of the reference design. The performance test was carried out for an optimized regenerative fan to validate the performance of the numerically predicted optimal design.