• Title/Summary/Keyword: 손잡이

Search Result 180, Processing Time 0.022 seconds

Analysis on infection control of general hospital radiology (종합병원 영상의학과의 감염관리 대한 분석)

  • Shin, Jung-Sub;Park, Cheol-Woo;Jeon, Byeong-Kyou
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.335-342
    • /
    • 2012
  • This study aims to find a way to control infection of community radiology effectively by calculating the degree of contamination, culture and identifying the flora in radiology of five general hospitals in Gyeongsangbuk-do. Staphylococcus, Micrococcus, Pseudomonas stutzeri, Pseudomonas oryzihabitans were identified as surface flora. These are know to be pathogens of hospital acquired infection and there was no radiology-specific flora. Research subject hospitals were conducting similar infection control education but degree of contamination of each hospital showed significant difference. Difference in degree of contamination according to contact sources were analyzed by Contact sources were classified into technologist-using, patients-using and common-using materials. Analysis of each hospital's degree of contamination showed that patient-using materials were significantly more contaminated than technologist-using and common-using materials (p<0.001). Devices which are similar to each other in monthly average frequency of use showed no significant difference in degree of contamination, but general X-ray devices and chest boards which are used most frequently showed higher degree of contamination than others. In addition, hospital A, B and C which have heavier monthly average caseload showed relatively high degree of contamination on irradiation devices which are used by technologists only or by technologists and patients commonly, office desks and doorpulls. Hence it is considered that intensity of infection control education should be different according to the degree of monthly average caseload. This study provided an opportunity to aware that technologists' feeling of contamination is crucial for infection control of radiology, and the Accupoint ATP public hygiene monitoring system which was used in this study for measuring the degree of contamination was proved to be an effective measuring device for hospital acquired infection management.

An Visiting Environmental Assessment and Countermeasures for Ecological Park of Sun-Cheon Bay - Focused on a Universal Design Principle - (순천만 자연생태공원 탐방환경 평가와 개선방안 - 유니버설 디자인 원칙을 중심으로 -)

  • Lee, Kyung-Chan;Kim, Nam-Jo
    • Korean Journal of Environment and Ecology
    • /
    • v.27 no.6
    • /
    • pp.777-793
    • /
    • 2013
  • The purpose of this study is to provide the basic reference for appropriate ecological park planning through investigation and analysis of inviting environment of Suncheon Bay Ecological Park within the framework of 'universal design'. For this, investigating items were selected through literature reviews and legal standard of ecological park suggested by laws. Field survey on Suncheon Bay Ecological Park was conducted, The results suggesting analytical and practical implications are as follows. First, guided handles of any facilities were not equipped, so urgent supplementation is needed with legal standard of universal design. Especially, detailed criterion of universal design focusing on visitors' convenience should be reflected. Second, all facilities for the blind were not equipped and the floor height of entrance was also unsuitable. It implies that the disabled and the senior are restrained from doing independent activity, therefore, appropriate standard focusing on 'universal design' for the wide open activity space such as the park area should be re-provided. Finally, guidelines for applicable universal design of the activity space for the experience on the ecological park should be re-established.

Development of Novel Assistive Device for Improving Usability of BVM (인공호흡기 사용성 향상을 위한 새로운 보조기구 개발)

  • Jeon, Gang-Hyun;Park, Yong-Jai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.420-426
    • /
    • 2020
  • In this study, an assistive device for BVM (Bag Valve Mask) was developed. When emergencies occur, rescuers must perform artificial respiration within four minutes utilizing suitable BVM. If not, the patient can suffer serious damage within their brain and body systems. The rescuer must execute artificial respiration until the patient arrives at the hospital. In the process of artificial respiration, the rescuer can feel fatigued in their forearm muscles, particularly those who may have smaller hands or weaker muscle strength. Many products have been developed to solve these problems, but these products are difficult to market and commercialize because of their volume, size, and difficulty of use. In this paper, the BVM assistive device that has been previously manufactured was improved, and an attempt was made to devise a new method that reduces the burden on the user. The BVM assistive device can be divided into three-parts: a head part for compressing the air bag, which can control the amount of air; the body part for coupling with BVM; and finally, the handle that can rotate for better use on various postures of patients. Throughout the experiment, the assistive device could inject an equal amount of air into the patients. As a result, the rescuer could feel less fatigue and inject a suitable amount of air to emergency patients during artificial respiration.

Study on Operating Limits of 5.56mm Rifle Overheat - Focusing on Human Engineering (5.56mm 소총 과열에 의한 운용한계 분석 - 인간공학 중심으로)

  • Lee, Ho-Jun;Choi, Si-Young;Shin, Tae-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.49-56
    • /
    • 2020
  • High temperature heat generated during rifle firing not only degrades the performance of the weapon, but also limits the user's operation. In this study, temperature change of handguard according to firing was measured with reference to Human Engineering criteria and the operability according to material was examined. Accordingly, for the firing test, three types of Korean rifle and one overseas model were selected for each material of handguard, and firing test was conducted using a contact type temperature meter. The test result shows that using a plastic handguard with low thermal conductivity and aluminum handguard with high thermal conductivity enabled the rifles to be operated with bare hands even when firing at more than 100 rounds at low atmospheric temperature. However, when firing more than 60 rounds at over 20℃ atmospheric temperature, aluminum handguard use is limited. When firing quickly over 100 rounds, handguard use is restricted regardless of its fabrication material. To eliminate operational limitations by overheating, it is necessary to eliminate direct contact with skin using gloves, vertical grips, etc. This study examined the operability of rifles in terms of thermal risk, and the resulting study results are expected to be used as basic data for Human Engineering of other rifles and munitions.

The Wheelchair Design for Persons with Disabilities (지체장애인용 수동식 휠체어 디자인)

  • 신학수;김성남
    • Archives of design research
    • /
    • v.11
    • /
    • pp.48-58
    • /
    • 1995
  • In 1981. KOREA applied YEAR OF WORLD DISABLED DESIGNNATED BY UN as starting point to begin noticing disabled and gradually improve and understand the problems of the disabled.This study considering the income level and welfare level selected basic most widely used wheelchair as subject of study. Design Application of this study's main analysis are as follolVs 1. MAN-MACHINE INTERFACE STUDY ANALYSIS!Basic concept of wheelchair is for persons uncapable of move by sitting down. so main focus of study was considered on equipment which on chair. 2. WHEELCHAm MOVEMENT STUDY ANALYSISlThrough movement and test measurement which can be considered as basic study of Ergonomics, observe movement changes accordingly. 3. BACK(MAIN) WHEEL AND HANDRIM MOVEMENT ANALYSIS / Seat and wheel as the most important component of a wheelchair, study the relation of handrim and hand movement and test the most effective and comfortable handrim. Direction of the study was concerntrated on three areas, with results and information collected, would like to suggest design change of X type collapsible chair in areas of size of SEAT(air pocket type), HANDRIM(anti-slip hump), ARMHEST(transfer movement, rubber padding. accent), and HANDLE(adjustable, round type). The content started this study is only one small position of understanding the disabled. Also, the importance of one of many business of assisting disabled rehabilitation. (IJISABLED, REHABILITATION. APPROACH)

  • PDF

A Study of Dermal and Ocular Exposure to Isocyanate-Based Paints in Crash Repair Workshops (차량수리업에서 사용하는 이소시안계 페인트에 의한 피부와 눈의 노출에 관한 연구)

  • Lee, Su-Gil;Pisaniello, Dino;Lee, Nae-Woo;Tkaczuk, Michael
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.72-78
    • /
    • 2009
  • Exposure to HDI(hexamethylene di-isocyanate) commonly used in vehicle crash repair workshops remains a leading cause of occupational asthma. Although skin and eye contamination are considered as absorption routes, there are no occupational exposure standards for skin and ocular exposure. This is the reason why there are more empirical data should be provided. Therefore this study was to determine contamination levels of HDI on the skin, eyes, work surfaces, respirators and eye protectors. There was evidence of contamination on a variety of work surfaces, for example, door handles, bench top and spray gun, etc. A high proportion(47~80%) of skin wipe samples from neck, forehead, back hand, palm and wrist was positive for HDI contamination, even though spray time was relatively brief. The contamination levels from spraying inside spray booth were generally higher than outside booth due to poor work practices and inappropriate personal protective use like safety gloves. Apprentices had higher exposure levels than the qualified painters, likely due to lack of the recognition of safety and hygiene. The extent of contamination inside the PPE might provide an indication of the potential for respiratory & skin exposure and ocular exposure. Eye fluid samples from 4 out of 14 workers had the positive detection of HDI contamination, due to poor work practices like no or inappropriate eye protection. Considering the potential for dermal & ocular exposure to contribute to possible health symptoms including respiratory sensitization, the empirical data point to a need for improving work practices and appropriate PPE selection, use and maintenance.

Carbonization Patten and Operation Characteristics of a 1Φ 2 W MCCB Damaged by PCITS (PCITS에 의해 소손된 1Φ 2 W MCCB의 탄화 패턴 및 작동 특성)

  • Lee, Jae-Hyuk;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.8-13
    • /
    • 2014
  • The purpose of this study is to analyze the damage pattern when overcurrent is applied to a thermal magnetic type molded case circuit breaker (MCCB) using a Primary Current Injection Test System (PCITS). When an overcurrent of 150 A was applied to the PCITS for 5 seconds with the trip bar of an MCCB being damaged, it was found that the surface of the temperature control device (bimetallic strip) positioned at the right was significantly carbonized. When an overcurrent of 300 A was applied to the PCITS for 5 s under the same conditions, the entire temperature control device was deteriorated, becoming flattened and in close contact with the MCCB. When an overcurrent of 450 A was applied to the PCITS for 5 s, the coil of the temperature control device was melted and disconnected. In addition, it was observed that the contacts, the enclosure and upper cover were deformed and there was a trace of carbonization on them. When approximately 3 s had elapsed after an overcurrent of 600 A was applied, white smoke occurred inside the MCCB and a flame was radiated out, after which the overcurrent supply stopped with "phutt" (whomp) sound. It was observed that when the same type of MCCB is damaged by a general flame, the surfaces of its handle, terminal, arc divider (extinguisher) and temperature control device were carbonized uniformly. In addition, it was found that the trip bar of the operating mechanism was melted down and the metal operation pin was moved while being tripped.

Research on the detection of LCN DNA from traces on firearms (총기 흔적흔에서의 low copy number(LCN) DNA 검출에 관한 연구)

  • Jeon, Chung-Hyun;Park, Sung-Woo
    • Analytical Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.51-59
    • /
    • 2011
  • Genetic Identification has become an important forensic investigation method which discerns identity through analysis of physical samples discovered in various crime scenes. Recently more samples are being requested to undergo A-STR analysis of low copy number (LCN) DNA, which is known as touch evidence-type sample and left on various objects such as a pen briefly used by the criminal, the gear of the car used for driving, the handle, and various buttons inside a car. This research attempted to extract the LCN DNA of the touch evidencetype left on crushed fingerprints on firearms, etc. and examine the genotyping success rate. Four types of firearms (M16, K1A, COLT 45 Pistol, M29 Revolver) were fired individually and physical samples were gathered from four parts of each firearm. Subsequently, in order to extract the LCN DNA, Microkit and $Prepfiler^{TM}$ were used to compare and analyze the quantity of DNA extracted and the genotyping success rate. Analysis results showed that the quantity of DNA extracted by $Prepfiler^{TM}$ was on average 1.7 times higher than that of Microkit, and in genotype analysis success rate $Prepfiler^{TM}$ also demonstrated 24.9% on average in contrast to 0% for Microkit. In regards to the grip part of the K1A, $Prepfiler^{TM}$'s success rate was as high as 50.6%.

A development of an independent electric power generating portable flashlight by using solar battery (태양전지를 이용한 자가발전 손전등 개발에 관한 연구)

  • Kim, Hong-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1795-1801
    • /
    • 2009
  • In this study, a portable flashlight which can manually generate the electricity by using sunlight was developed so that it can be used in the extreme environmental condition such as no-electricity condition. Battery is charged by using solar battery during the day, but when sunlight is not avalible during the night or rainy day, a handle is rotated to generate the electricity in order to charge the battery manually. To improve the brightness of the light, light is concentrated by using the optical lens. Low electric consumption circuit is used for the longer operating time by suppress electrical consumption while lamp is discharged. A circuit is designed and used for steady electrical curris dand voltage to insure steady battery charging. Super-discharge circuit and protection circuit are used for the super discharge of battery when it is not used for a long time. Also the constant charge is possible by using houseware adapter. As a result, a portable flashlight is designed to charge with sunlight during day, and with houseware adapter during night. A portable flashlight is also designed to irradiate longer distances by improvement of the brightness of the light using the optical lens. Thus, it forms white natural ray of light making possible for night reading.

Microbiological Quality Evaluation for Application of the HACCP System to the Bakery Products at Small Scale Bakeries (소규모 베이커리에서의 HACCP적용을 위한 미생물학적 위해도 평가)

  • 엄애선;권성희;정덕화;오상석;이헌옥
    • Korean journal of food and cookery science
    • /
    • v.19 no.4
    • /
    • pp.454-462
    • /
    • 2003
  • Recently, the HACCP(Hazard Analysis Critical Control Point) system has been emphasized in food processing industries throughout the world. However, the system has, as yet, not been applied very well to domestic food industries. Due to the increase in the consumption of bakery products, more studies are required on the application of HACCP to establish the system in small-scale bakeries. This study was designed to provide basic data for setting management standards for HACCP, based on microbiological hazard evaluations of bakery products. Red bean paste filled breads, custard cream filled breads and cakes covered with fresh whipping cream were collected, and microbiological evaluations conducted on the raw materials, the manufacturing processes and potential hazards. The result showed the presence of coliforms in fresh cream of cakes and the soybean paste of soybean paste breads at levels as high as 105 CFU/g on the hazard analysis of the raw materials. Moreover, the general levels of bacteria and coliforms were over those of the standards during the intermediate fermentation and molding processes. Furthermore, high levels of coliforms were detected on the hands of the salesmen and bakers themselves. This suggests that the CCPs (Critical Control Points), such as fresh cream and red bean paste manufacturing process desperately require better management. There is also a requirement for education relating to personal hygiene for the production of hygienic bakery products and for the publics health.