Park, Hyung-Ho;Lee, Hye-Youn;Lee, Jae-Sung;Yu, Jae-Eun
Journal of Conservation Science
/
v.29
no.3
/
pp.287-296
/
2013
Excavated iron objects are preserved in stable condition through processes of conservation treatment because they are found in the form of various corrosion products. However, the conservation treatment leads to re-corrosion over time and accordingly, iron objects can be severely damaged, and therefore fundamental measures need to be prepared to control it. In this study, the types and characteristics of corrosion products were scientifically analyzed according to the re-corrosion of iron artifacts. In addition, the stability of the corrosion products was evaluated by exposing the standard samples under the re-corrosion environment. Re-corrosion proceeded with weeping in reddish brown on the cracks of iron artifacts. Weeping was detected akagan$\acute{e}$ite had a low hydrogen ion concentration and high chloride ion. The selection of standard sample goethite, lepidocrocite, hematite, and magnetite, were evaluated corrosive by weeping. After the samples were immersed in HCl(pH 1), $H_2SO_4$(pH 1), $H_2O$(pH 6) solution, they had been maintained for 180 days in relative humidity of 20%, 50%, 80% to investiage the changes of chemical components. As a result of analysis, the changes of chemical components were not showed in goethite, lepidocrocite, and hematite. But magnetite was changed to lepidocrocite in solution including chloride ion($Cl^-$) and to goethite and lepidocrocite solution including sulfuric acid($SO{_4}^{2-}$). Results of the study, in the case of magnetite known as s stable corrosion compound, it was identified the corrosion of magnetite occurs by corrosive ions, which means weeping generated in the iron artifacts can corrode magnetite as well as base metal.
This study was designed to examine the effectiveness of an unused tunnel as a rice storage place. The physicochemical changes of rice grains were investigated during 8-months of storage in the tunnel located at Kyungnam province, Korea. Two kinds of tunnel stored rices, NP(rice grown with no pesticides) and LP(rice grown with less pesticides) were compared with $5^{\circ}C$ stored rice as a control. The peroxidase activities, as an index of freshness of rice grains, gradually decreased and NP appeared to be fresher than LP. Whiteness, grain wholeness, and chalkyness were less desirable for the tunnel stored rice than the control, with no significant difference of physicochemical properties, including the broken, damaged, colored rice, and contents of moisture, protein, and amylose. Palatability dropped below 70 in all three groups at later phase. The sensory evaluation showed that overall preference was slightly higher for the control but not significantly different from the other two groups. From all the evidences shown, unused tunnels may be an effective place for a long-term rice storage, since the average temperature inside the tunnel was maintained very constantly around $14.3^{\circ}C$ and relative humidity was optimal for rice storage, especially during spring and summer seasons.
Purpose: The goal of this study is to evaluate the minimum three-year follow-up results of reverse total shoulder arthroplasty (RTSA) for glenohumeral (GH) arthritic and pseudoparalytic patients with severe rotator cuff deficiency. Materials and Methods: We evaluated 13 patients (three males and 10 females) who underwent RTSA from July 2007 to July 2010. The average follow-up duration was 54.2 months (range, 37~74 months). Clinical results were evaluated using the Visual Analog Scale (VAS) for pain, active Range of Motion (ROM): active forward flexion (aFF); active external rotation at the side (aERs); active internal rotation to the back (aIRb), American Shoulder and Elbow Surgeons (ASES) score, Korean Shoulder Score (KSS), and intraoperative and postoperative complications. Results: VAS score improved from 7.5(6~10) points to 1.5(0~4), and ROM of active forward elevation improved from $42.7(10{\sim}100)^{\circ}$ to $129.1(110{\sim}180)^{\circ}$. In addition, ASES score improved from preoperative 32.9 (11.7~46.7) points to 80.2(58.3~95.0) postoperatively, and KSS score improved from 36.8(24~47) points to 78.4 (61~92). Twelve out of 13 cases showed various degrees of scapular notching at the last follow-up. There was one case of intraoperative anterior glenoid fracture and two cases of temporary nerve injury. Revision surgery was performed in two cases for treatment of delayed postoperative deep infection. Conclusion: According to minimum three-year follow-up results, RTSA may be an effective treatment option for glenohumeral (GH) arthritic and pseudoparalytic patients. However, considering the possibility of complications related to delayed deep infection or surgeon's technique, RTSA should be judiciously and carefully indicated by expert surgeons.
This study was conducted to investigate changes of pH, meat color, cooking loss, shear force and sensory evaluation on Hanwoo meat fed with supplemental fig fermentation(SFF) during storage period. A total of 10 Hanwoo bulls were subjected to one of two treatment diets (control and 10% SFF) from live weight of 400kg far 6 months. After slaughter, longissimus muscles were removed, zipper-wrapped and stored at 4$\^{C}$ for 21 days. The pH, meat color, cooking loss, shear force and sensory evaluation of the samples were measured at 1, 3, 9, 15, 21 days of storage. There were no differences in pH, meat objective color(Hunter L, a and b) and cooking loss (%) of longissimus muscles between control and SFF treatment during storage. Shear force values of longissimus muscle from SFF treatment showed lower level in 1, 3 and 9 days and tended to decrease during storage. No differences in odor and appearance of sensory evaluation were observed between control and SFF treatment during storage. The taste induced by SFF was increased(f<0.05) at 1, 3 and 9 days of storage. These results indicate that the SFF may improve meat quality of Hanwoo during storage.
LEE Kang-Ho;CHO Ho-Sung;LEE Dong-Ho;KIM Min-Gi;CHO Young-Je;SUH Jae-Soo;KIM Dong-Soo
Korean Journal of Fisheries and Aquatic Sciences
/
v.26
no.4
/
pp.330-339
/
1993
To optimize the processing conditions of fermented ascidian, Halocynthia roretzi, fermentation at low temperature with different salt contents, the effect of enzymes added, and the quality changes during fermentation were investigated. As the quality factors, changes in such components as free amino acid, volatile basic nitrogen(VBN), amino nitrogen, total creatinine, total carotenoid, extents of browning, reducing sugar and glycogen were determined. The quality was also evaluated organolatically by pannel test. Fresh deshelled and sliced ascidian were fermented for 50 days at $5{\pm}1^{\circ}C$ with different salt contents of 5, 10, $15\%$ (w/w) with enzyme contents of papain $0.1\%$ and protease-A $0.1\%$ VBN increased gradually during the 50 days of fermentation and showed $30{\sim}40mg/100g$ at 30, 35 and 45 days in case of salt contents 5, 10 and $15\%$ added with $0.1\%$ papain and protease-A, respectively. Amino nitrogen and the total creatinine increased until 20 days, hereafter tended to decrease gradually. Total carotenoid and glycogen also decreased during the fermentation. The results of sensory evaluation of fermented ascidian at $5{\pm}1^{\circ}C$ added $0.1\%$ papain or protease-A showed that the peculiar taste and flavor of ascidian was sustained for $30{\sim}40$ at least 20 days with $5\%$ NaCl and $35{\sim}45$ days of fermentation with 10 and $15\%$ NaCl.
According to the new climate change agreement, technology development to reduce greenhouse gases is actively conducted worldwide, and research on energy efficiency improvement in the field of power generation and transmission and distribution is underway [1,2]. Economic analysis of the operation method of storing and supplying surplus electricity using energy storage devices, and using energy storage devices as a frequency adjustment reserve power in regional cogeneration plants has been reported as the most profitable operation method [3-7]. Therefore, this study conducted an economic analysis for the installation of energy storage devices in the combined heat and power plant in the Czech Republic. The most important factor in evaluating the economics of battery energy storage devices is the lifespan, and the warranty life is generally 10 to 15 years, based on charging and discharging once a day. For the simulation, the ratio of battery and PCS was designed as 1: 1 and 1: 2. In general, the primary frequency control is designed as 1: 4, but considering the characteristics of the cogeneration plant, it is set at a ratio of up to 1: 2, and the capacity is simulated at 1MW to 10MW and 2MWh to 20MWh according to each ratio. Therefore, life was evaluated based on the number of cycles per year. In the case of installing a battery energy storage system in a combined heat and power plant in the Czech Republic, the payback period of 3MW / 3MWh is more favorable than 5MW / 5MWh, considering the local infrastructure and power market. It is estimated to be about 3 years or 5 years from the simple payback period considering the estimated purchase price without subsidies. If you lower the purchase price by 50%, the purchase cost is an important part of the cost for the entire lifetime, so the payback period is about half as short. It can be, but it is impossible to secure profitability through the economy at the scale of 3MWh and 5MWh. If the price of the electricity market falls by 50%, the payback period will be three years longer in P1 mode and two years longer in P2 and P3 modes.
Choi, Eun Ji;Park, Hae Woong;Chung, Young Bae;Kim, Jin Se;Park, Seok Ho;Chun, Ho Hyun
Food Science and Preservation
/
v.24
no.2
/
pp.168-180
/
2017
This study was performed to determine the rapid thawing method for reducing the thawing time of frozen pork loins and to examine the effects of supercooling on the microbiological, physicochemical, and sensory qualities of fresh and frozen-thawed pork during storage at -1.5, 4, and $15^{\circ}C$. Forced-air thawing at $4^{\circ}C$ was the most time-consuming process, whereas radio frequency thawing time was the shortest by dielectric heating. The supercooling storage temperature was chosen to be $-1.5^{\circ}C$ because microstructural damages were not observed in the pork sample after cooling at $-1.5^{\circ}C$ for 24 h. Fresh or frozen-thawed pork loins stored at $-1.5^{\circ}C$ had lower drip loss and total volatile base nitrogen, thiobarbituric acid-reactive substance, and Hunter b* levels than loins stored at 4 and $15^{\circ}C$. In addition, the least degree of increase in preexisting microorganisms counts of the fresh or frozen-thawed pork loin samples was obtained during supercooled storage at $-1.5^{\circ}C$. Sensory quality results of fresh and frozen-thawed pork loin samples stored at $-1.5^{\circ}C$ showed higher scores than the samples stored at 4 and $15^{\circ}C$. These data indicate that supercooling at $-1.5^{\circ}C$ in the meat processing industry would be effective for maintaining the quality of pork meats without ice crystal nucleation and formation.
Son, Sang Jun;Park, Jang Pil;Kim, Min Jeong;Yoo, Suk Hyun
The Journal of Korean Society for Radiation Therapy
/
v.26
no.1
/
pp.107-114
/
2014
Purpose : The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head & neck radiation treatment planning CT with metal artifact created by dental implant. Materials and Methods : All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120kVp, 2mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). Results : In cases of head&neck phantom, the difference of dose distibution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. Conclusion : The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area even turned tissue HU by wrong correction was founded, too. Consequentially, It seems O-MAR algorithm is not perfect to distinguish air cavity and photon starvation artifact. Nevertheless, the differences of HU and dose distribution are not a huge that is not suitable for clinical use. And there are more advantages in clinic for improved quality of CT images and DRRs, precision of contouring OARs or tumors and correcting artifact area. So original and O-MAR CT must be used together in clinic for more accurate treatment plan.
Kim, Yong-Min;Cho, Byung-Ki;Kim, Dong-Soo;Choi, Eui-Sung;Shon, Hyun-Chul;Park, Kyoung-Jin;Kim, Dong-Hwan
Journal of Korean Orthopaedic Sports Medicine
/
v.10
no.1
/
pp.35-40
/
2011
Purpose: This study was performed to evaluate the diagnostic usefulness of ankle stress radiograph for evaluation of chronic lateral ankle instability. Materials and Methods: Among patients undergoing the modified-Brostrom procedure, 42 cases with complete rupture of the anterior talofibular ligament were enrolled in this study. Sixty Korean adults (120 cases) were recruited as the control group. Radiologic measurement of talar tilt and anterior talar translation was performed through stress radiographs using Telos device. We obtained the normal range of Korean adults, and used as a standard value for judgment of mechanical instability. We analyzed the sensitivity, specificity, positive and negative prediction value of ankle stress radiograph. Results: On ankle stress radiograph, normal range of talar tilt angle and anterior talar translation was below $8.3^{\circ}$, below 7.6mm. Talar tilt angle on varus stress radiograph showed 57% of sensitivity, 97% of specificity, 89% of positive and 86% of negative prediction value. Anterior talar translation on anterior drawer stress radiograph showed 69% of sensitivity, 97% of specificity, 91% of positive and 90% of negative prediction value. Conclusion: Ankle stress radiograph had a good specificity, positive and negative prediction value for the evaluation of mechanical instability. However it underestimated the mechanical instability of ankle joint. It must be remembered that normal stress radiograph does not exclude ankle instability.
Purpose: This study is to compare the clinical results of ACL reconstruction between three groups using hamstring tendon autograft, mixed and tibialis tendon allograft. Materials and Methods: Between August 2003 and August 2008, we analyzed 169 cases of ACL reconstruction, 66 cases used hamstring tendon autograft, 42 cases used mixed graft and 61 cases used tibialis tendon allograft, with a minimum follow-up of 12 months. For the clinical evaluation, we evaluated the Lysholm score, Telos stress test device and IKDC score. Results: The average side to side difference in Telos stress test decreased from $7.5{\pm}1.0$ mm to $1.6{\pm}1.0$ mm in autograft group, from $7.6{\pm}1.1$ mm to $1.4{\pm}1.1$ mm in mixed graft group and from $7.4{\pm}1.3$ mm to $2.5{\pm}1.3$ mm in allograft group. The average Lysholm knee score improved from 58.6 to 92.3 in autograft group, from 60.6 to 92.6 in mixed graft group and from 55.3 to 91.5 in allograft group. There was no significant difference between three groups in clinical results. At second look arthroscopy, tension of ligament and synovial coverage were good result in autograft and mixed graft than allograft group. Conclusion: All hamstring tendon autograft, mixed graft and tibialis tendon allograft groups showed satisfactory clinical results, with no significant difference in outcomes between the groups. Both hamstring tendon autograft and mixed graft showed good synovial coverage in second look arthroscopy. So mixed graft will be considered as good alternative in case of shorter or thin harvested hamstring tendon.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.