• Title/Summary/Keyword: 손상 크기

Search Result 814, Processing Time 0.032 seconds

Manufacture and Characterization of Melamine/Urea/Formaldehyde Based Microcapsules for Self-healing Applications (자가손상복구용 Melamine/Urea/Formaldehyde 마이크로캡슐의 제조 및 특성 분석)

  • Liu, Xing;Lee, Jong-Keun;Kim, Jung-Seok
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1674-1678
    • /
    • 2008
  • 자가손상복구 기법에서 마이크로캡슐은 손상복구 효율을 좌우하는 중요한 역할을 한다. 본 연구에서는 다양한 종류의 손상복구액을 함유한 마이크로캡슐을 Melamine/Urea/Formaldehyde를 외벽물질로 하여 in-situ 중합법에 의해서 oil-in-water emulsion 방법으로 제조하였다. 제조된 마이크로캡슐을 광학현미경, 주사전자현미경으로 캡슐 모폴로지, 외부 및 내부표면, 외벽 두께 등을 조사하였다. 그리고 입도분석기를 이용하여 캡슐의 크기를 측정하였으며 그 결과 캡슐의 직경은 평균 약 120 마이크론 정도였다.

  • PDF

Rail surface inclined crack growth analysis considering periodic grinding (주기적 마모를 고려한 레일표면 경사균열 진전해석)

  • Jun, Hyun-Kyu;You, Won-Hee;Ham, Young-Sam
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.493-498
    • /
    • 2011
  • 구름접촉피로는 차륜과 레일의 반복적인 접촉으로 인하여 발생하는 표면손상현상으로 점차 증가하는 레일손상 중 하나이다. 접촉마모 및 주기적 그라인딩보다 균열의 성장속도가 더 빨라 균열진전이 시작되는 최소균열크기(minimum crack size for growth)는 레일의 파괴방지 및 유효한 유지보수전략을 수립하는데 기초자료로 활용된다. 본 연구에서는 최소균열크기를 예측하기 위하여 차륜레일의 접촉에 영향을 미치는 주요 파라미터를 변화시키면서 최소균열크기의 변화를 살펴보았다. 이를 위하여 Fletcher와 Kapoor의 "2.5D"모델을 적용한 시뮬레이션 소프트웨어를 개발하였으며, 최대접촉하중(1174MPa), 표면마찰계수(0.1, 0.2, 0.3 and 0.4), 잔류응력, 접촉에 의한 표면마모(1.0nm/cycle), 그라인딩량(0.3mm/10MGT)을 파라미터로 하여 해석을 수행하였다. 해석결과 최소균열크기는 해석조건에 따라 1.41-1.95mm로 계산되었다.

  • PDF

Shear Damage Behavior of Reinforced Concrete Beams under Fatigue Loads (반복하중을 받는 철근콘크리트보의 전단피로손상거동)

  • 오병환;한승환;이형준;김지상;신호상
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.1
    • /
    • pp.143-151
    • /
    • 1998
  • 최근들어 반복하중에 의한 철근콘크리트 구조물의 손상이 자주 발견되고 있으며 교량 등의 구조물 등은 때때로 과적차량에 의한 초과하중을 받아 이러한 피로손상이 심화되고 있다. 본 연구에서는 이러한 반복 하중을 받는 철근 콘크리트보의 누적피로손상에 대한 실험적 연구룰 수행하여 피로하중에 의한 철근콘크리트보의 손상과정을 규명하였다. 실험 변수를 전단철근의 양과 반복되는 하중의 크기 및 반복횟수로 하여 실험부재를 제작하였으며, 하중제어에 의한 휨시험법에 의해 3Hz의 반복하중을 시편에 재하하였다. 사인장 균열하중과 사인장 균열 후 반복하중에서의 보의 손상누적거동 즉 처짐. 전단철근의 변형도, 에너지 손실 등의 변화를 실험적으로 평가하였으며, 이를 통하여 반복하중에 의한 누적손상에 의해 철근 콘크리트보의처짐 및 전단변형도가 초기하중상태에서는 급격히 증가하다가 이후 점진적으로 증가하는 것을 규명하였다. 본 연구의 결과는 사용하중상태에서 점진적으로 발생할 수 있는 피로손상의 누적과정을 기술하여 주고 있다.

Decomposing the Electro-Mechanical Signatures of Collocated Piezoelectric Wafers for the Baseline-Free Damage Diagnosis of a Plate (판의 무기저 손상 진단을 위한 병치형 압전웨이퍼의 전기역학적 신호 분해)

  • Kim, Eun-Jin;Sohn, Hoon;Park, Hyun-Woo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.347-351
    • /
    • 2010
  • 판과 같은 구조물의 손상 감지를 위해, 손상 전 구조물의 임피던스 신호를 기저신호(Baseline impedance signal)로 이용하여 직접적으로 비교하지 않는 새로운 개념의 무기저 손상진단 기법(Reference-free impedance method)을 제시한다. 박막 압전소자(이하 PZT)를 판의 상하 표면에 부착시킨 한 쌍의 병치 PZT를 이용하여 손상으로 인해 모드변환을 일으키는 전기역학적 신호(Electro Mechanical Signatures ; 이하 EMS)를 추출한다. 이 연구에서는 스펙트럼 요소법(Spectral Element Method ; 이하 SEM)을 이용하여 주파수 영역에서 병치된 PZT의 EMS를 파악하기 위한 수치해석을 수행한다. 특히, 손상에 의해 발생된 모드변환 EMSMC를 병치된 PZT의 극성에 기인한 신호분해 기법을 적용하여 추출하고, 분해된 모드변환 EMSMC가 손상의 위치와 크기에 따라 받는 영향을 추가로 분석한다.

  • PDF

Effect of Community-based Rehabilitation on Patients with Brain Injury: Meta-analysis Based on the ICF Model (뇌손상 환자의 지역사회재활(CBR) 프로그램의 효과: ICF 모델에 근거한 메타분석)

  • Cha, Yu-Jin;Kim, Se-Yun
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.3
    • /
    • pp.203-214
    • /
    • 2014
  • In this study, a meta-analysis was conducted to investigate the effect of community-based rehabilitation on patients with brain injury by ICF factor in previous studies and examine the application of recent community-based rehabilitation program. Total 15 articles that satisfied the selection criteria were divided by ICF factors to obtain the effect size. Homogeneity and publication bias were tested for those selected papers. As a result, the overall effect size of community-based rehabilitation was 0.22; the effect size by physical function and structure among the ICF factors came to be 0.21; and the effect size of activity and participation was 0.20, indicating a small effect size. The studies involved in a meta-analysis were considered as the absence of heterogeneity and publication bias, which indicates that the results of this study are subjectively reliable. These results well explained the level of change on ICF factors, especially physical function and structure, activity and participation, in other words, the intervention effect of community-based rehabilitation on patients with brain injury.

A Study on Improving the Efficiency of Facility Safety Inspection Work Using Images (영상을 활용한 시설물 안전점검 작업 효율성 향상 방안 연구)

  • Jeon, Kyungsik;Kim, Jintae;Lee, Byoungkil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.3
    • /
    • pp.179-186
    • /
    • 2021
  • In general, the daily safety inspection activities, which investigate damages in structures and measures the size of the damage, have been relied heavily on the visual inspection so far. Since the probe of the condition and performance of facilities by such personnel is often dependent on the subjective judgment of the investigator, the consistency and repeatability of the probing results may reduce. Particularly, damage located in a difficult-to-reach place depends mainly on experience with the naked eye, and an unsafe method using a ladder has mainly applied when necessary. Therefore, in this study, we tried to propose a way of using images that can reduce the deviation between safety inspection investigators, enhance objectivity, and improve the safety of workers. In this study, we have applied homographic transformation as a method of correcting the image. As a result of analyzing the size of the damage in the corrected image of the test subject, it confirms that the accuracy of measuring the magnitude of the damage can satisfy the target levels of 5.0mm and 0.005m2, the target accuracy levels. As a result of the field verification test to which the proposed image correction technique applied, the coefficient of variation of the crack length in the structure decreased from 5.4~7.0% to 0.072~0.12%, and that of the damaged area from 10.9% to 1.6%. It confirms that the measurement accuracy is improved. Therefore, it is expected that this study on the image utilization technique in safety inspection activities can increase the accuracy of damage measurement and improve the reliability of the safety inspection reports and exterior survey drawings.

Fracture Behavior of Pre-cracked AISI 4130 Specimens by Means of Acoustic Emission and Ultrasonic C-scan Measurements (음향방출과 초음파 C-scan을 이용한 AISI 4130 균열재의 파괴거동 연구)

  • Ong, J.W.;Moon, S.I.;Jeong, H.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.3
    • /
    • pp.7-13
    • /
    • 1993
  • Fracture behavior of pre-cracked compact tension specimens made of AISI 4130 steel was investigated using acoustic emission (AE) and ultrasonic C-scan measurements. While each specimen was loaded up to a certain level, various acoustic emission parameters were recorded together with the crack opening displacement (COD). An elastic-plastic finite element analysis was performed to calculate COD and the damage (plastic) zone size ahead of crack tip. Ultrasonic C-scans, in a pulse-echo, immersion mode, were done for mapping the damage zone size. The agreement between the finite element results and the measured COD was satisfactory. Based on AE results, the test specimens were found to show ductile behavior. The slope of the total ringdown counts vs. COD curve was useful to determine the crack initiation. The preliminary C-scan images showed evidence of changes in the amplitude of ultrasonic signal in the damaged region, and the shape and size of the damage zone matched qualitatively with the finite element results. A further work on the damage zone sizing was also pointed out.

  • PDF

쌀가루의 입자크기 비율에 따른 품질 특성

  • 금준석;이현유;조윤성;최봉규;태현주;최민화
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.10a
    • /
    • pp.222.1-222
    • /
    • 2003
  • 쌀가루 제조 후 입자크기 비율에 따른 품질 특성을 검토하였다. 혼합 쌀가루의 색도를 보면 100-200메쉬 사이의 쌀가루 색도에 있어 자기는 유의성을 보이지 않았고 혼합쌀가루가 습식의 함량이 많을수록 쌀가루의 밝기가 증가됨을 나타내었다. 건식과 습식의 비율에 있어 밝기는 유의성을 나타내었지만 a값과 b값의 경우 혼합비율에 유의성을 나타내지 않았다. 혼합쌀가루 역시 입자크기가 작을수록, 건식쌀가루의 혼합 비율이 높을 수록 수분흡수지수(WAI) 및 수분용해지수(WSI)의 값은 높은 경향을 나타내었다. 80메쉬의 혼합쌀가루는 건식쌀가루의 혼합 비율에 상관없이 거의 같은 WAI의 값을 나타내었고, 100-140메쉬의 혼합쌀가루의 WAI 값이 가장 높은 값을 나타내었다. WAI와 WSI의 값은 각각 쌀가루의 수분함량과는 유의적인 연관성은 없는 것으로 나타났으며 각 쌀가루의 입자의 크기와 건식, 습식쌀가루의 종류와 혼합 비율에 따라 변화가 있는 것으로 나타났다. 입자의 크기에 따른 호화엔탈피의 변화는 200메쉬 이하의 입자 크기에서는 큰 영향을 주지 못했으나 200메쉬 이상에서는 호화엔탈피 값에 차이가 있었다. 혼합쌀가루의 경우 입자가 클수록 전분손상도가 낮게 나왔으며 건식쌀가루의 함량이 높을수록 전분손상도가 높게 나타났다.

  • PDF

Structural Diagnosis in Time Domain on Damage Size (손상크기에 따른 시간영역에서의 구조물 진단)

  • 권대규;임숙정;방두열;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.259-262
    • /
    • 2002
  • This paper provides the experimental verification of a non-destructive time domain approach to examine structural damage. Time histories of the vibration response of structure were used to identify the presence of damage. Damage in a structure cause changes in the physical coefficients of mass density, elastic modulus and damping coefficient. This paper examines the use of beam like structures with PVDF sensor and PZT actuator to perform identification of those physical parameters, and hence to detect the damage. Experimental results are presented from tests on cantilevered composite beams damaged at different location and with damage of different dimensions. It is demonstrated that the method can sense the presence of damage, and characterize the damage to a satisfactory precision.

  • PDF

EXPERIMENTAL ESOPHAGEAL INJURY WITH DISC BATTERY (수은전지에 의한 식도손상)

  • 박언우;남부현;나기상;유장열;박찬일
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1987.05a
    • /
    • pp.14-14
    • /
    • 1987
  • 최근 수은전지의 사용이 증가함에 따라 이에 의한 식도이물의 가능성도 증가하게 되었다. 저자는 수은전지에 의한 식도손상을 관찰하기 위하여 가토(1.7kg~2.5kg)에서 수은전지(충전된 전지, 방전된 전지)와 같은 모양, 크기의 철판(대조군)을 상절치에서 약 15cm되는 식도에 삽입 후 시간별로(1, 3, 6, 12, 24시간)육안적, 조직학적 관찰을 하였다. 충전된 전지를 삽입한 군에서는 삽입 후 1시간부터 식도손상을 보였고 시간경과에 따라 그 정도가 심해졌으며, 방전된 전지를 삽입한 군에서는 삽입후 3시간부터 식도손상을 보였고 시간 경과에 따라 그 정도가 심해졌으나 충전된 전지군에 비하여는 경한 손상을 보였으며, 대조군에서는 삽입 후 24시간까지 손상을 보이지 않았다. 따라서 수은전지에 의한 식도이물은 조기에 심한 식도손상을 초래하므로 가능한 한 신속히 제거해야 할 것으로 생각된다.

  • PDF