• Title/Summary/Keyword: 손상 위치

Search Result 817, Processing Time 0.027 seconds

Evaluation of Data-based Expansion Joint-gap for Digital Maintenance (디지털 유지관리를 위한 데이터 기반 교량 신축이음 유간 평가 )

  • Jongho Park;Yooseong Shin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.2
    • /
    • pp.1-8
    • /
    • 2024
  • The expansion joint is installed to offset the expansion of the superstructure and must ensure sufficient gap during its service life. In detailed guideline of safety inspection and precise safety diagnosis for bridge, damage due to lack or excessive gap is specified, but there are insufficient standards for determining the abnormal behavior of superstructures. In this study, a data-based maintenance was proposed by continuously monitoring the expansion-gap data of the same expansion joint. A total of 2,756 data were collected from 689 expansion joint, taking into account the effects of season. We have developed a method to evaluate changes in the expansion joint-gap that can analyze the thermal movement through four or more data at the same location, and classified the factors that affect the superstructure behavior and analyze the influence of each factor through deep learning and explainable artificial intelligence(AI). Abnormal behavior of the superstructure was classified into narrowing and functional failure through the expansion joint-gap evaluation graph. The influence factor analysis using deep learning and explainable AI is considered to be reliable because the results can be explained by the existing expansion gap calculation formula and bridge design.

Precise Diagnosis and Conservation Treatment of the Twin-lion Stone Lantern from the Godalsa Temple Site, Yeoju (여주 고달사지 쌍사자 석등의 정밀진단 및 보존처리)

  • National Museum of Korea Conservation Science Division;Damwon Cultural Heritage Inc.;Man Gyeong Corp.
    • Conservation Science in Museum
    • /
    • v.31
    • /
    • pp.71-103
    • /
    • 2024
  • The National Museum of Korea Conservation science division conducted a precise diagnosis and a non-destructive investigation to comprehensively assess the overall damage of the Twin-lion stone lantern from the Godalsa Temple site, Yeoju to be placed on display in the museum's outdoor stone garden, then reviewed the relevant conservation and management plan and applied conservation treatment to the artifact. The museum carried out the treatment in the following order: precise diagnosis; dismantling of the previously-restored part of the roof stone; reinforcement and restoration of the roof structure with new stone; restoration of the previously-restored part of the lantern's support stone (jungseok); surface texture treatment to the restored area; cleaning (basic, laser); and color matching. The previously-restored part of the roof stone was removed and restored with new stone material, based on the results of a safety diagnosis regarding the separation at the said part. Granite from the Sangju area was selected as the material for the restoration in consideration of the results of mineral analysis as well as the surface color and particle size. The new stone was divided into three pieces based on the descending edges of the octagonal roof structure and joined together using epoxy resin. The structure was further strengthened by inserting titanium rods. It is expected that the status diagnosis and conservation treatment of the twin-lion stone lantern from the Godalsa Temple site in Yeoju will be used as a reference for the future conservation and management of outdoor displays of stone cultural heritage.

A numerical analysis study on the effects of rock mass anisotropy on tunnel excavation (암반의 이방성이 터널 굴착에 미치는 영향에 대한 수치해석적 연구)

  • Ji-Seok Yun;Sang-Hyeok Shin;Han-Eol Kim;Han-Kyu Yoo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.4
    • /
    • pp.327-344
    • /
    • 2024
  • In general tunnel design and analysis, rock masses are often assumed to be isotropic. Under isotropic conditions, material properties are uniform in all directions, leading to a higher evaluation of tunnel stability. However, actual rock masses exhibit anisotropic characteristics due to discontinuities such as joints, bedding planes, and faults, which cause material properties to vary with direction. This anisotropy significantly affects the stress distribution during tunnel excavation, leading to non-uniform deformation and increased risk of damage. Therefore, thorough pre-analysis is essential. This study analyzes the displacement and stress changes occurring during tunnel excavation based on rock anisotropy. A three-dimensional numerical analysis was performed, selecting anisotropy index and dip angles as variables. The results showed that as the anisotropy index increased, the displacement in the tunnel increased, and stress concentration became more pronounced. The maximum displacement and shear stress were observed where the dip planes met the tunnel.

The Effect of the Axial Plane on Measurement of Available Bone Height for Dental Implant in Computed Tomography of the Mandible (하악의 전산화 단층사진에서 횡단면이 임플랜트를 위한 가용골 높이의 결정에 미치는 영향)

  • Jhin, Min-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.379-388
    • /
    • 2002
  • For the success of dental implant, accurate radiographic evaluation is prerequisite for planning the location of the osseointegrated implants and avoiding injury to vital structures. CT/MPR(computed tomography/multiplanar reformation) shows improved visualization of inferior alveolar canal. In order to obtain cross-sectional images parallel to the teeth, the occlusal plane is used to orientate for the axial plane. If the direction of axial plane is not parallel to the occlusal plane, the reformatted cross-sectional scans will be oblique to the planned fixture direction and will not show the actual dimension of the planned fixture's location. If the available bone height which measured in the cross-sectional view is much greater than the actual available bone height, penetration of canal may occur. The aim of this study is to assess the effect of the axial plane to measurement of available bone height for dental implant in computed tomography of the mandible. 40 patients who had made radiographic stents and had taken CT were selected. The sites that were included in the study were 45 molar regions. In the central panoramic scan, the length from alveolar crest to superior border of inferior alveolar canal(available bone height, ABH) was measured in direction of reformatted cross-sectional plane(uncorrected ABH). Then, length from alveolar crest to superior border of canal was measured in direction of stent(corrected ABH). The angle between uncorrected ABH and corrected ABH was measured. From each ABH, available fixture length was decided by $Br{{\aa}}nemark$ system. The results were following ; the difference between two ABHs was statistically significant in both first and second molar(p< 0.01). The percentage of difference more than 1 mm was 8.7% in first molar and 15.5% in second molar. The percentage of difference more than 2 mm was 2.0% in first molar and 6.6% in second molar. The maximum value of difference was 2.5 mm in first molar and 2.2 mm in second molar. The correlations between difference of 2 ABHs and angle was positive correlations in both first and second molar. The correlation coefficient was 0.534 in first molar and 0.728 in second molar. The second molar has a stronger positive correlation. The percentage of disagreement between 2 fixture lengths from two ABHs was 24.4% in first molar and 28.9% in second molar.

New Technique for the Reconstruction of Both Anteromedial & Posterolateral Bundles of ACL (전방십자인대의 전내측 다발 및 후외측 다발을 각각 재건하는 새로운 수술 수기)

  • Ha Chul-Won;Awe Soo-Ik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.195-199
    • /
    • 2002
  • This article is to report a new technique for reconstruction of the anteromedial and posterolateral bundles of anterior cruciate ligament by separate tensioning and fixation of the each bundle. Method : Tibial and femoral tunnels were made with conventional technique of anterior cruciate ligament reconstruction. Tibial tunnel was enlarged $5\~7$ mm in anterior-posterior direction to make oval it in cross section. When preparing the Achilles tendon allograft, bone plug portion was trimmed as the conventional technique. The tendinous portion was trimmed as two separate bundles by dividing the tendinous portion longitudinally, so the graft is shaped like 'Y'. The bone plug portion of allograft was inserted into the femoral tunnel and fixed with absorbable cross pins. Two ligamentous portionss of the distal part of the grafts were tensioned separately at the external orifice. Anteromedial bundle was fastened under maximum tension with the knee flexed 90 degrees by post-tie method. The posterolateral bundle was fixed by the same technique with the knee in full extension. Then, an absorbable interference screw was inserted between the two bundles upto the upper end of the tibial tunnel, to get more initial rigidity of the reconstructed graft as well as to locate the two bundles in more anatomic position.

  • PDF

Cortical bone thickness and root proximity at mandibular interradicular sites: implications for orthodontic mini-implant placement (하악의 교정용 미니 임플랜트 식립 부위에서의 피질골 두께와 치근간 거리: 3차원으로 재구성한 CT 영상을 이용한 연구)

  • Lim, Ju-Eun;Lim, Won-Hee;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.38 no.6
    • /
    • pp.397-406
    • /
    • 2008
  • Objective: The purpose of this study was to provide clinical guidelines to indicate the best location for mini-implants as it relates to the cortical bone thickness and root proximity. Methods: CT images from 14 men and 14 women were used to evaluate the buccal interradicular cortical bone thickness and root proximity from mesial to the central incisor to the 2nd molar. Cortical bone thickness was measured at 4 different angles including $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, and $45^{\circ}$. Results: There was a statistically significant difference in cortical bone thickness between the second premolar/first permanent molar site, central incisor/central incisor site, between the first/second permanent molar site and in the anterior region. A statistically significant difference in cortical bone thickness was also found when the angulation of placement was increased except for the 2 mm level from the alveolar crest. Interradicular spaces at the 1st/2nd premolar, 2nd premolar/1st permanent molar and 1st/2nd permanent molar sites are considered to be wide enough for mini-implant placement without root damage. Conclusions: Given the limits of this study, mini-implants for orthodontic anchorage may be well placed at the 4 and 6 mm level from the alveolar crest in the posterior region with a $30^{\circ}$ and $45^{\circ}$ angulation upon placement.

Clinical Study of Childhood Accidents from a Hospital Over Ten Years with Regard to Foreign Body Aspiration (단일병원에서 관찰한 최근 10년간의 소아 우발사고에 관한 연구 : 이물흡인을 중심으로)

  • Kim, Cheol-Min;Song, Jun-Young;Kim, Ja Hyung;Kim, Ki Soo;Hong, Soo-Jong
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.9
    • /
    • pp.1134-1140
    • /
    • 2002
  • Purpose : Childhood accidents have been increasing recently. Accidents rank as the leading cause of childhood mortality and morbidity. We performed this study to evaluate the causes of childhood accidents. Methods : The authors analysed retrospectively the medical records of 6,410 cases of childhood accidental injuries who visited the emergency room of Asan Medical Center from January 1990 to December 1999. Results : The most common type of accidents was trauma which accounted for 5,038 cases of the total accidents, followed by falls, burns, foreign body aspiration, and poisoning. The most common age of foreign body aspiration was under two years old and the male to female ratio was 2 to 1. The most common site of foreign body aspiration was the esophagus and the stomach, followed by the respiratory tract. In airways, the right and left main bronchus were the most common site for foreign body aspiration and were accompanied by the highest mortality. The most common foreign body in the gastrointestinal tract and respiratory tract were coins and peanuts, respectively. Conclusion : The most common cause of accidents was trauma, followed by falls, burns, foreign body aspiration, and poisoning. The incidence of foreign body aspiration and poisoning is increasing in infants. In cases of foreign bodies in airways, proper management is needed because of the high mortality rate.

Comparison of Early Complications after Peritoneal Dialysis Catheter Implantation by Laparoscopic Surgery and Conventional Surgery in Children (소아에서 복막투석도관 삽입시 복강경을 이용한 방법과 기존의 수술법에 따른 초기 합병증 발생의 차이)

  • Jeong, Soo-In;Lee, Hyun-Young;Lee, Cheol-Gu;Seo, Jeong-Meen;Lee, Suk-Koo;Kim, Su-Jin;Kwak, Min-Jung;Jin, Dong-Kyu;Paik, Kyung-Hoon
    • Childhood Kidney Diseases
    • /
    • v.11 no.1
    • /
    • pp.51-58
    • /
    • 2007
  • Purpose : To assess the early complication of laparoscopic peritoneal dialysis catheter implantation in children. Methods : Medical record review was carried out on 21 laparoscopic and 16 conventional peritoneal dialysis catheter implantations which were performed in 31 children under 18 years of age between 2002 and 2006. All medical records were retrospectively analyzed. The patients were followed until 2 months after catheter placement. Patient characteristics and catheterrelated complications, such as significant bleeding, leakage, obstruction, migration, insertion site infection and peritonitis during the first 60 days after implantation were recorded. Results : After conventional operation, dialysate leakage occurred in 2 of 16 cases and all cases improved after conservative management. In 1 case, significant bleeding occurred and re-operation was performed. Three cases of obstruction due to migration were reported, 2 cases underwent reoperation and 1 case improved without intervention. After laparoscopic surgery, outflow obstruction occurred in 1 out of 21 cases, which was caused by adhesion after several reinsertions of the catheter and recurrent peritonitis. No migration was noted after laparoscopic surgery. There was no significant difference in the complication rate between the two groups. Conclusion : Laparoscopic peritoneal dialysis catheter placement is feasible in children of all age groups, with at least equivalent functional results compared to conventional surgery. The additional advantage of laparoscopic catheter insertion is the option to identify and eliminate anatomical risk factors, such as intra-abdominal adhesions, and to perform partial omentectomy without additional incisions.

  • PDF

Ultrasonographic Measurement of Articular Cartilage Thickness of Medial Femoral Condyle in Knee Osteoarthritis (슬관절 골관절염에서 초음파를 이용한 대퇴 내과 관절 연골의 두께 측정)

  • Kim, Jung-Man;Kim, Tae-Hyung;Im, Dong-Sun;Kang, Min-Gu;Lee, Kyu-Jo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.1
    • /
    • pp.7-14
    • /
    • 2011
  • Purpose: The purpose of this study was to analyze the correlation between the medial joint space on weight bearing simple X-ray and the ultrasonographic articular cartilage thickness. Materials and Methods: The articular cartilage thickness of 91 osteoarthritic knees of 73 patients were measured with weight bearing simple X-ray and ultrasonography between June 2010 and September 2010. Male were 13 and female were 60. Right knees were 35, left knees were 20 and bilateral involvements were 18. Medial joint spaces on X-ray were measured in full extension view and $45^{\circ}$ PA(Rosenberg) view. Femoral cartilage thicknesses at and those at the point between the middle 1/3 and posterior 1/3 area were measured by ultrasonography, that were scanned coronally at $30^{\circ}$ flexion and $130^{\circ}$ flexion respectively. The results were analyzed statistically by Pearson correlation test and Bland-Altman plot test. Results: Medial joint spaces measured in full extension view and femoral articular cartilage thicknesses at the point between the anterior 1/3 and middle 1/3 area measured with sonography were statistically correlated and medial joint spaces measured in $45^{\circ}$ PA view and those at the point between the middle 1/3 and posterior 1/3 area measured with sonography were also correlated (P<0.05, $SD{\pm}2$). Conclusion: The measurement of articular cartilage thicknesses by the ultrasonography was easy even in the patient who are unable to take weight bearing view and was thought to be a useful diagnostic and follow up method to examine the degenerative change in addition to simple radiographic examination in the knee osteoarthritis.

  • PDF

Pediatric Urolithiasis: Our 22-year Experience at a Single Center (소아에서의 요로결석: 단일기관에서 22년간의 경험)

  • Kim, Su-Yon;Kim, Min-Jee;Lee, Joo Hoon;Kim, Kun Suk;Park, Young Seo
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.101-109
    • /
    • 2013
  • Purpose: Pediatric urolithiasis is uncommon in children but is a cause of significant morbidity and damage to the kidney. Although much information on adult urolithiasis is available in the literature, large studies on the pediatric population are still scarce. In this report, we review our experience with pediatric urolithiasis over 22 years at a tertiary referral center. Method: We retrospectively reviewed the records of children with newly diagnosed urolithiasis between January 1991 and May 2013. We assessed the age, sex, family history, initial symptoms, location of stones, underlying cause, stone analysis, treatment, and recurrence among the patients. Results: In total, 137 patients (96 male, 41 female) were assessed. The age range was 0-17 years (mean age, 6.0 years). Forty-three (31%) children were aged <1 year, and 37% (16/43) had a history of intensive care unit (ICU) admission. Thirteen patients (9.5%) had a family history of stones. The most common symptoms at presentation among the patients were gross hematuria (56/137, 41%) and flank or abdominal pain (46/137, 34%). The stones were located in the kidney (85/137, 62%), ureter (29/137, 21%), bladder (2/137, 1.4%), and multiple locations (20/137, 15 %). Congenital abnormalities of the genitourinary (G-U) tract, with or without metabolic abnormality, or urinary tract infection (UTI) was detected in 26 children (19%). Ninety-one patients (66%) underwent metabolic examination, and 38% of these patients exhibited an abnormality. UTI, with or without abnormalities of the G-U tract, or metabolic abnormality was detected in 26 children (19%). Of the 35 stones analyzed, the majority were calcium stones (20/35, 57%), followed by infected stones (5/35, 14%), uric acid stones (4/35, 11%), carbonate apatite stones (3/35, 7%), cystine stones (2/35, 6%), and phosphate stones (1/35, 3%). Five patients (4%) required open procedures, with or without non-open procedures, whereas 77 patients (56%) were managed conservatively; the remaining 55 patients (40%) received some other form of intervention. Eighteen patients (13%) had stone recurrence during the follow-up period. Conclusions: Pediatric urolithiasis is commonly associated with abnormalities of the G-U tract and/or metabolic disorders and/or UTI. Half of the patients will pass their stones spontaneously, and all the techniques of minimally invasive surgery are applicable in the treatment of children with stones. As the recurrence rates are high among this population, long-term follow-up is recommended and the complete clearance of stones is important.