• Title/Summary/Keyword: 손상합

Search Result 86, Processing Time 0.024 seconds

Evaluation of PTO Severeness for 78 kW-Class Tractor According to Disk Plow Tillage and Rotary Tillage (디스크플라우 및 로타리 작업에 따른 78 kW급 트랙터 PTO 가혹도 평가)

  • Kim, Wan Soo;Kim, Yong Joo;Park, Seong Un;Hong, Soon Jung;Kim, Yeon Soo
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.23-31
    • /
    • 2019
  • The purpose of this study was to evaluate the PTO severeness for an agricultural tractor during disk plow and rotary tillage. The PTO load measurement system was constructed with data acquisition and a PTO torquemeter. Field experiments were conducted at a combination of traveling speed (L3 Low, L3 High) and PTO speed (P1, P2). The load spectrum was generated using the rain-flow counting method, and the SWT method was used to consider the range and mean of the PTO load. The damage sum was calculated by applying a modified miner rule, which is a cumulative damage law. The relative severeness was expressed as the ratio of the lowest damage sum. Relative severeness was higher with the lower PTO gear stage, and higher driving gear stage and it was approximately 40-102 times higher for rotary tillage than disk plow tillage in the same gear stages. The relative severeness was 1010.12 in the rotary tillage under L3 High P1 based on the disk plow tillage under L3 Low P2.

Antegrade Interlocking Intramedullary Nailing in Humeral Shaft Fractures (상완골 간부 골절에서의 전향적 교합성 골수강내 금속정 고정술)

  • Cho, Chul-Hyun;Song, Kwang-Soon;Kim, Sin-Ki
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • Purpose: To evaluate the results and complications of antegrade intramedullary interlocking nailing in humerus shaft fractures. Materials and Methods: We evaluated the clinical outcomes, radiologic results and complications in 47 patients with humerus shaft fracture treated with antegrade intramedullary interlocking nailing, and followed up until bony union. Bony union was confirmed by serial plain radiographs and the clinical outcomes were assessed according to the ASES scoring system. Results: Bony union was confirmed in 41 (87.2%) out of a total 47 patients, and the mean union period was 14.5 weeks. Major complications were as follows: 6 non-union, 3 delayed union, 2 intraoperative posterior cortex fracture in the distal humerus and 2 permanent shoulder pain, including 1 case of adhesive capsulitis. The clinical outcomes were as follows: 29 excellent, 11 good, 4 fair and 3 poor. Satisfactory outcomes were demonstrated in 40 patients (85.1%). Conclusion: Anterograde intramedullary interlocking nailing as treatment for humerus shaft fracture showed satisfactory bony union and clinical outcomes. It is considered an efficacious treatment, especially in patients with associated injury, such as multiple fractures and segmental fracture.

3.5 mm T-shaped LCP (Locking Compression Plate) Fixation for Unstable Distal Clavicular Fractures (3.5 mm T형 잠김 금속판을 이용한 원위 쇄골 골절의 치료 결과)

  • Lee, Churl-Woo;Kim, Hee-Chun;Roh, Jae-Young;Park, Young-Su
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.41-45
    • /
    • 2008
  • Purpose: To review the clinical and radiological results after an open reduction and internal fixation with a T-shaped LCP for unstable distal clavicle fractures. Materials and Methods: From February 2005 to June 2006, ten patients with distal clavicle Neer type II fractures were treated with an open reduction and internal fixation with a T-shaped LCP. Bony union was identified by plain radiography. The clinical results were analyzed according to the UCLA scoring system. Results: The mean time to fracture union was 9weeks and union was achieved in all cases. The mean UCLA score was 33.4 (30-35); excellent in 8 cases and good in 2 cases. In one case, loosening of one distal screw was occured and mild AC joint subluxation was observed in another case. Conclusion: 3.5 mm T-shaped LCP fixation is a useful technique for treating unstable distal clavicle fractures. This procedure provide stable fixation with no further AC joint injury.

Coracoclavicular Ligament Augmentation Using Endobutton for Unstable Distal Clavicle Fractures - Preliminary Report - (불안정성 쇄골 원위부 골절에서의 Endobutton을 이용한 오구 쇄골 인대 보강술 - 예비 보고 -)

  • Cho, Chul-Hyun;Jung, Gu-Hee;Sin, Hong-Kwan;Lee, Young-Kuk;Park, Jin-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the radiologic and clinical outcomes after operative treatment using endobuttons for unstable distal clavicle fractures. Materials and Methods: Between October 2007 and September 2009, 9 consecutive patients who were followed up for at least more than 12 months after operative treatment using a TightRope$^{(R)}$ were studied. The radiologic results on the serial plain radiographs and the clinical results according to the American Shoulder Elbow Surgeons (ASES) score were analyzed. Result: Bony union was shown in 8 cases (88.9%) and the average time to union was 12.9 (range: 9~16) weeks. The average coracoclavicular distances at the postoperative and final follow-up were 5.6 mm and 6.2 mm, respectively, with no statistically significant difference (p>0.05). The average ASES score was 90.3 (range: 78~96) and the clinical outcomes were 6 excellent, 2 good and one fair. There were no complications such as implant failure or infection except for one case of nonunion due to loss of the initial reduction. Conclusion: A major advantage of TightRope$^{(R)}$ fixation for unstable distal clavicle fractures is that no further surgery is needed to remove the implant. We suggest that this technique provides an alternative for fracture with a distal fragment, which is difficult to fix.

The Effect of Kamihaengche-tang Plus Yukmijihwang-tangon Oxidant and Hg-induced Rabbit's Liver Cell Injury (가미행체탕 합 육미지황탕이 Oxidant 및 Hg에 의한 가토 간세포손상에 미치는 영향)

  • 이수행;김원길;김우환
    • The Journal of Korean Medicine
    • /
    • v.23 no.3
    • /
    • pp.174-187
    • /
    • 2002
  • Objectives : This study was carried out to determine whether Kamihaengche-tang plus Yulanijihwang-tang (KCYH) exerts a protective effect against oxidant-induced liver cell injury. Methods : Cell injury was estimated by measuring lactate dehydrogenase (LDH) and alanine aminotransferase (ALT) release, and lipid peroxidation was estimated by measuring malondialdehyde, a product of lipid peroxidation in rabbit liver slices. Results : Oxidants (tBHP and $H_2O_2$) increased dose-dependently LDH release which was significantly prevented by 1% KCYH. The protective effect of KCYH against oxidant-induced cell injury was dose-dependent in the range of 0.05-1 % concentrations. Similarly, KCYH inhibited oxidant-induced lipid peroxidation in a dose-dependent manner. When liver tissues were exposed to Hg (0.5 mM), ALT activity in the medium and lipid peroxidation in tissues were markedly increased. These changes were prevented by 1% KCYH, KCYH restored toxicant-induced inhibition of cellular GSH content. KCYH increased the activities of catalase and glutathion peroxidase in oxidant-treated tissues. Conclusions : These results indicate that KCYH exerts a protective effect against oxidant-induced liver cell injury, and this effect is attributed to prevention of lipid peroxidation. These effects may be due to an increase in concentration of endogenous antioxidants.

  • PDF

Thermo-Mechancal Fatigue of the Nickel Base Superalloy IN738LC for Gas Turbine Blades (가스터빈 블레이드용 IN738LC의 열기계피로수명에 관한 연구)

  • Fleury, E.;Ha, J.S.;Hyun, J.S.;Jang, S.W.;Jung, H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.188-193
    • /
    • 2000
  • A more accurate life prediction for gas turbine blade takes into account the material behavior under the complex thermo-mechanical fatigue(TMF) cycles normally encountered in turbine operation. An experimental program has been carried out to address the thermo-mechanical fatigue life of the IN738LC nickel-base superalloy. In the first phase of the study, out-of-phase and in-phase TMF experiments have been performed on uncoated and coated materials. In the temperature range investigated. the deposition of NiCrAlY air plasma sprayed coating did not affect the fatigue resistance. In the second phase of the study, a physically-base life prediction model that takes into account of the contribution of different damage mechanisms has been applied. This model was able to reflect the temperature and strain rate dependences of isothermal cycling fatigue lives, and the strain-temperature history effect on the thermo-mechanical fatigue lives.

  • PDF

Numerical Study and Firing Test of a Liquid Rocket Engine Head with a Coolant Manifold (로켓엔진 헤드용 냉각 매니폴드의 해석 및 시험)

  • Park, Jinsoo;Choi, Jiseon;Yu, Isang;Ko, Youngsung;Kim, Sunjin;Shin, Dongsun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1021-1025
    • /
    • 2017
  • Numerical heat/flow analysis was performed on a liquid rocket engine head with the cooling water manifold to ensure the durability of a ground test facility for heat exchanger. Through these studies, the shapes of the injector and the flow path were determined and applied to the head of the engine under development. Firing tests were conducted to verify the designed coolant manifold and no thermal damage was found on the engine-head-face. Comparing the combustion test results with the numerical analysis, the outlet temperature of coolant showed a difference of about $15^{\circ}C$. This trend is reasonable considering existence of LOX manifold, thermal barrier coating, and the actual location of flame.

  • PDF

Three-Dimensional Container Packing Problem (컨테이너 3차원 적재문제)

  • 배민주;최세경;김환성
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2003.05a
    • /
    • pp.242-248
    • /
    • 2003
  • In this paper, we propose a new heuristic solution for 3D container packing problem for the variable size and the variable kind of freights. First we consider the total cost of container charges, i.e., loading, transportation and handling charges, where the priority of each frights are dealt. By minimizing the total cost of container charges, the kinds of container and its number can be decided automatically. From these factors, we con determine the position in the container and the loading sequence into the container. Finally, by equivalence of freight's weight in container, we can prevent the freight's damage on the handling.

  • PDF

Risk Assessment Technique for Gas Fuel Supply System of Combined Cycle Power Plants (I) : Based on API RBI Procedures (복합화력발전의 가스연료 공급계통에 대한 위험도 평가 기법 연구 (I) : API RBI 절차에 기반한 위험도 평가)

  • Song, Jung Soo;Yu, Jong Min;Han, Seung Youn;Choi, Jeong Woo;Yoon, Kee Bong
    • Journal of Energy Engineering
    • /
    • v.27 no.2
    • /
    • pp.1-13
    • /
    • 2018
  • The proportion of natural gas-fueled power generation is expanding due to the change of domestic energy policy pursuing reduction of dust and increasing clean energy consumption. Natural gas fuels used for the combined-cycle power plants and the district-heating power plants are operated at high temperature and high pressure in the fuel supply system. Accidents due to leakage of the gas such as fire and explosion should be prevented by applying risk management techniques. In this study, risk assessment was performed on the natural gas fuel supply system of a combined power plant based on the API RP 581 RBI code. For the application of the API RBI code, lines and segments of the evaluation target system were identified. Operational data and input information were analyzed for the calculations of probability of failure and consequence of failure. The results of the risk assessment were analyzed over time from the initial installation time. In the code-based evaluation, the gas fuel supply system was mainly affected by thinning, external damage, and mechanical fatigue damage mechanisms. As the operating time passes, the risk is expected to increase due to the external damage caused by the CUI(Corrosion Under Insulation).

Economic analysis of Frequency Regulation Battery Energy Storage System for Czech combined heat & power plant (체코 열병합발전소 주파수조정용 배터리에너지저장장치 경제성 분석)

  • KIM, YuTack;Cha, DongMin;Jung, SooAn;Son, SangHak
    • Journal of Energy Engineering
    • /
    • v.29 no.2
    • /
    • pp.68-78
    • /
    • 2020
  • According to the new climate change agreement, technology development to reduce greenhouse gases is actively conducted worldwide, and research on energy efficiency improvement in the field of power generation and transmission and distribution is underway [1,2]. Economic analysis of the operation method of storing and supplying surplus electricity using energy storage devices, and using energy storage devices as a frequency adjustment reserve power in regional cogeneration plants has been reported as the most profitable operation method [3-7]. Therefore, this study conducted an economic analysis for the installation of energy storage devices in the combined heat and power plant in the Czech Republic. The most important factor in evaluating the economics of battery energy storage devices is the lifespan, and the warranty life is generally 10 to 15 years, based on charging and discharging once a day. For the simulation, the ratio of battery and PCS was designed as 1: 1 and 1: 2. In general, the primary frequency control is designed as 1: 4, but considering the characteristics of the cogeneration plant, it is set at a ratio of up to 1: 2, and the capacity is simulated at 1MW to 10MW and 2MWh to 20MWh according to each ratio. Therefore, life was evaluated based on the number of cycles per year. In the case of installing a battery energy storage system in a combined heat and power plant in the Czech Republic, the payback period of 3MW / 3MWh is more favorable than 5MW / 5MWh, considering the local infrastructure and power market. It is estimated to be about 3 years or 5 years from the simple payback period considering the estimated purchase price without subsidies. If you lower the purchase price by 50%, the purchase cost is an important part of the cost for the entire lifetime, so the payback period is about half as short. It can be, but it is impossible to secure profitability through the economy at the scale of 3MWh and 5MWh. If the price of the electricity market falls by 50%, the payback period will be three years longer in P1 mode and two years longer in P2 and P3 modes.