• Title/Summary/Keyword: 속도측정

Search Result 6,731, Processing Time 0.034 seconds

Development and Validation of a Measurement Technique for Interfacial Velocity in Liquid-gas Separated Flow Using IR-PTV (적외선 입자추적유속계를 이용한 액체-기체 분리유동 시 계면속도 측정기법 개발 및 검증)

  • Kim, Sangeun;Kim, Hyungdae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.549-555
    • /
    • 2015
  • A measurement technique of interfacial velocity in air-water separated flow by particle tracking velocimetry using an infrared camera (IR-PTV) was developed. As infrared light with wavelength in the range of 3-5 um could hardly penetrate water, IR-PTV can selectively visualize only the tracer particles existing in depths less than 20 um underneath the air-water interface. To validate the measurement accuracy of the IR-PTV technique, a measurement of the interfacial velocity of the air-water separated flow using Styrofoam particles floating in water was conducted. The interfacial velocity values obtained with the two different measurement techniques showed good agreement with errors less than 5%. It was found from the experimental results obtained using the developed technique that with increasing air velocity, the interfacial velocity proportionally increases, likely because of the increased interfacial stress.

Development of a device to measure the speed of motor used in a crane (기중기에 사용된 모터의 회전수 측정장치 개발)

  • 김강철;한석붕
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.05a
    • /
    • pp.374-377
    • /
    • 2001
  • 본 논문에서는 기중기에 사용된 모터의 회전수를 측정하는 정치를 설계하였다. 이 장치는 로타리엔코더, 회전수를 계산하는 속도 측정부, LCD 표시부 및 모터의 방향판별회로로 구성된다. 모터의 회전수측정 장치는 모터의 회전수를 측정하여 RPM으로 표시하고, 모터가 6° 회전 후에 모터의 방향을 판별할 수 있다. 그리고 모터가 제한속도를 벗어나면 위험신호를 발생하는 신호와 회전방향을 나타내는 신호를 발생한다.

Construction of Ultrasound Pulsed Doppler Velocimeter (펄스 초음파 도플러 속도계의 제작에 관한 연구)

  • 현석봉;김수용;이재수
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.25-39
    • /
    • 1994
  • To measure the velocity of heart wall and local flow transctaneously in blood vessels, we have developed a single channel 3.1 MHz pulsed ultrasonic Doppler velocity meter. Ultrasound pluse width and repetition frequency (PRF) used in the velocity meter is 1 ${\mu}$sec 6kHz reapectively, and the Doppler shift of the backscattered echo signal is sensed in a phase detector by coherent demodulation method. From the output of the phase detector, the Doppler signal corresponding to the mean velocity of acoustic wave scatterers over a small region is obtained by using a range gate, sample holder and band-pass filter. Mean frequency of Doppler signal is estimated by zero-crossing counter and the instantaneous velocity of scatters is displayed as a function of time. It is possible to estimate velocity profile, volume flow and flow acceleration of vessels in man if the number of channels and range resolution in increased.

  • PDF

Error Filtering Algorithm for Accurate Travel Speed Measurement Using UTIS (UTIS 구간통행속도 이상치 제거 알고리즘)

  • Ki, Yong-Kul;Ahn, Gye-Hyeong;Kim, Eun-Jeong;Jeong, Jun-Ha;Bae, Kwang-Soo;Lee, Choul-Ki
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.6
    • /
    • pp.33-42
    • /
    • 2010
  • Travel speed is an important parameter in measurement of road traffic. UTIS(Urban Traffic Information System) was developed as a type of section detector. However, UTIS incur errors caused by irregular vehicle trajectories, wireless communication range and so on. This paper suggests a new model that use an error-filtering algorithm to improve the accuracy of travel speed measurements. In the field test, the variance of the percent errors measured by the new model was reduced. Therefore, it can be concluded that the proposed model significantly improves travel speed measuring accuracy.

Simulation of Moving Target by SAR Phase Shift (Range 압축 데이터 위상변위를 이용한 해수면 이동체의 시뮬레이션 고찰)

  • Kim, Youn-Seop;Yang, Chan-Su
    • Proceedings of the KSRS Conference
    • /
    • 2009.03a
    • /
    • pp.147-150
    • /
    • 2009
  • 본 논문에서는 해상 클러터를 고려하여 움직이는 물체의 SAR 원시 데이터를 생성하고, SAR 원시 데이터 중간 처리 결과인 range 압축 데이터의 azimuth 차분 신호로부터 물체의 속도를 측정하는 방법을 여러 가지 환경에 적용하여 그 정확도 및 적용 가능한 경우를 분석하였다. 움직이는 물체에 의한 도플러 중심 주파수의 변이가 azimuth 차분 신호에서 위상의 변화를 가져오므로, 이를 이용하여 움직이는 물체의 속도를 측정하는 알고리듬을 정리하였다. 이 알고리듬을 위에서 생성한 range 압축 데이터에 적용하여, 타깃이 되는 물체가 독립적으로 존재하는 경우, azimuth 상에 또 다른 속도를 가지는 산란체가 존재하는 경우, 그리고 높은 후방산란계수를 가지는 육지에 타깃이 되는 물체가 인접해 있는 경우를 가정하여 속도를 측정하였다. 그 결과, 타깃이 되는 물체가 SAR 영상에서 256 픽셀 범위 내에서 독립적으로 존재할 경우에는 높은 정확도로 물체의 속도를 측정할 수 있었으나, 128 픽셀 범위에 다른 움직이는 물체가 존재하거나, 높은 후방산란 계수를 갖는 육지와 인접해 있을 경우에는 최대 1m/s 의 오차를 나타냈다. 이는 주변 산란체의 영향에 의해 신호가 교란되어 목표물의 위치를 추정하는 과정에서 오차가 발생했기 때문이다.

  • PDF

The Effect of Surface Tension on Shear Wave Velocities according to Changes of Temperature and Degree of Saturation (온도와 포화도의 변화에 의한 표면장력이 전단파 속도에 미치는 영향)

  • Park, Jung-Hee;Kang, Min-Gu;Seo, Sun-Young;Lee, Jong-Sub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6C
    • /
    • pp.285-293
    • /
    • 2012
  • The surface tension, which is generated in the unsaturated soils, increases the stiffness of the soils. The objective of this study is to estimate the effect of the surface tension, which varies according to the temperature, on the shear wave velocity. Nine specimens, which have the different degree of saturation (0%, 2.5%, 5%, 10%, 20%, 40%, 60%, 80%, 100%), are prepared by using sand-silt mixtures. Experiments are carried out in a nylon cell designed for the measurement of shear waves. A pair of bender elements, which are used for the generation and detection of shear waves, is installed as a cross-hole type. The shear waves are continuously monitored and measured as the temperature of specimens decreases from $15^{\circ}C$ to $1^{\circ}C$. The results show that shear wave velocities of the fully saturated and fully dried specimens change a little bit as the temperatures of specimens decrease. However, the shear wave velocities of the specimens with the degree of saturations of 2.5%, 5%, 10%, 20%, 40%, 60% and 80% continuously increase as temperature decreases from $15^{\circ}C$ to $1^{\circ}C$. Furthermore, a fully saturated specimen is dried at the temperature of $70^{\circ}C$ in order to observe the shear waves according to degree of saturation. The shear wave velocities measured at the temperature of $70^{\circ}C$ are generally lower than those measured at temperature of $15^{\circ}C$. This study demonstrates that the dependence of shear wave velocities on the temperature according to the degree of saturation should be taken into account in both laboratory and field tests.

우주거리척도(Cosmic Distance Scale)로 사용되는 식쌍성 I. 알골형 식쌍성을 이용하여 측정한 거리

  • 홍경수;강영운
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.23-23
    • /
    • 2003
  • 천체의 거리는 다양한안 방법을 사용하여 직접 혹 간접적으로 측정되어왔다. 특히 우주배경복사를 측정하는 인공위성 관측의 정밀도가 혁명적으로 향상됨에 따라 우주의 나이는 수 % 이내의 정밀도로 결정할 수 있는 수준으로 발전하였다. 우주의 규모가 구체적으로 정의되는 가운데 우주의 절대적인 크기를 제시하기 위하여 천체의 거리를 측정하는데 사용되는 표준등불로 세페이드 변광성 이외에 식쌍성이 새롭게 대두되었다. 이 논문에서는 식쌍성이 거리척도의 표준등불이 될 수 잇는지 검증하기 위하여 광도곡선과 시선속도곡선이 잘 알려진 알골형 쌍성 식쌍성 RY Aqr, RX Gem, RS Vul을 선정하여 거리를 산출하였다. 별을 선정한 기준은 2색 이상의 광도곡선이 발표되고, 이중 분광쌍성으로 시선속도곡선이 각 성분별로 잘 관측되어 발표되고, IUE 관측 자료가 있는 알골형 쌍성이다. 거리 산출과정에서 간접적으로 유추하여 얻는 인자를 줄이기 위하여, 광도곡선으로부터 별의 상대적인 크기를 구하고, 시선속도곡선으로부터 공전궤도의 장반경을 구하고, 별의 에너지 분포 곡선으로부터 별의 온도를 측정하였다. 위 3종류의 관측 결과를 종합하여 식쌍성의 물리적 인자와 거리를 구하였다. 이와 같은 방법으로 구한 거리는 히파크러스를 이용하여 관측한 시차와 비교하였다.

  • PDF

LDV Measurement of Turbulent Flow Inside the Cylinder in an Engine (엔진 실린더내 유동 LDV측정)

  • 강건용;정동수
    • Journal of the KSME
    • /
    • v.33 no.12
    • /
    • pp.1063-1068
    • /
    • 1993
  • 왕복식엔진에서 연소과정은 실린더내 유체유동에 지배되므로 최적조건의 엔진설계를 위해서는 실린더내 유체유동을 효과적으로 이용하는 것이 필요하다. 연소과정에 중요한 영향을 미치는 압축말기 연소실내 난류강도는 흡입과정시 생성된 유동의 에너지가 압축과정을 거치면서 작은 스케일의 에디(eddy)로 깨지면서 발생된다. 연소과정시 이러한 에디들은 초기화염생성을 촉진 시키고 화염전파속도를 증진시키는 역할을 함으로써 실린더내 유체유동에 대한 이해증진을위해 실린더내 평균속도 및 난류유동을 측정하는 연구들이 많이 진행되고 있다. 엔진유동은 매사이 클의 유동이 엄밀히 주기적인 운동을 하지 않고, 각 사이클의 유동이 비정상유동을 하며, 유동의 생성 및 소멸이 매우 짧은 특성을 가진다. 따라서 산란입자가 측정체적을 통과할 때 속도데이 터가 발생하는 LDV(laser Doppler velocimetry) 측정에 있어서 레이저빔의 산란광노이즈 감소와 산란입자의 효율적인 공급으로 데이터 발생률을 높이는 것이 어려운 점이다. 이 글에서는 엔진 유동의 LDV측정시 고려해야 할 문제점들, 실험장치구성, 그리고 데이터처리 방법과 주요측정 결과에 대해 본 연구팀에서 지금까지 수행한 연구결과를 토대로 하여 기술하고자 한다.

  • PDF

A Method of Pedestrian Flow Speed Estimation Adaptive to Viewpoint Changes (시점변화에 적응적인 보행자 유동 속도 측정)

  • Lee, Gwang-Gook;Yoon, Ja-Young;Kim, Jae-Jun;Kim, Whoi-Yul
    • Journal of Broadcast Engineering
    • /
    • v.14 no.4
    • /
    • pp.409-418
    • /
    • 2009
  • This paper proposes a method to estimate the flow speed of pedestrians in surveillance videos. In the proposed method, the average moving speed of pedestrians is measured by estimating the size of real-world motion from the observed motion vectors. For this purpose, a pixel-to-meter conversion factor is introduced which is calculated from camera parameters. Also, the height information, which is missing because of camera projection, is predicted statistically from simulation experiments. Compared to the previous works for flow speed estimation, our method can be applied to various camera views because it separates scene parameters explicitly. Experiments are performed on both simulation image sequences and real video. In the experiments on simulation videos, the proposed method estimated the flow speed with average error of about 0.08m/s. The proposed method also showed promising results for the real video.

Tacho Pulse Non-uniformity Effects on Pulse Count Method (타코펄스 불균일성으로 인한 펄스개수측정방법 영향성)

  • Son, Jun-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.4
    • /
    • pp.301-309
    • /
    • 2021
  • Pulse count method is the classical reaction wheel speed detection method. In this study, we represent the pulse count method as mathematical equations. Instead of rotation speed, we model the reaction wheel rotation through rotation angle during sampling periods. We verified the effectiveness of the proposed model by comparing the pulse counts variation and averaging method effects from the model and previous research results. Then, we add tacho pulse non-uniformity to this verified model, and examine the errors of pulse count method. We express the measurement error increasement due to non-uniformity as mathematical equations, and also shows the requirement of moving average numbers to offset the measurement errors.