• Title/Summary/Keyword: 속도경사 G

Search Result 27, Processing Time 0.027 seconds

Seismic Fragility Evaluation of Inverted T-type Wall with a Backfill Slope Considering Site Conditions (사면 경사도가 있는 뒷채움토와 지반특성을 고려한 역T형 옹벽의 지진시 취약도 평가)

  • Seo, Hwanwoo;Kim, Byungmin;Park, Duhee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.533-541
    • /
    • 2021
  • Retaining walls have been used to prevent slope failure through resistance of earth pressure in railway, road, nuclear power plant, dam, and river infrastructure. To calculate dynamic earth pressure and determine the characteristics for seismic behavior, many researchers have analyzed the nonlinear response of ground and structure based on various numerical analyses (FLAC, PLAXIS, ABAQUS etc). In addition, seismic fragility evaluation is performed to ensure safety against earthquakes for structures. In this study, we used the FLAC2D program to understand the seismic response of the inverted T-type wall with a backfill slope, and evaluated seismic fragility based on relative horizontal displacements of the wall. Nonlinear site response analysis was performed for each site (S2 and S4) using the seven ground motions to calculate various seismic loadings reflecting site characteristics. The numerical model was validated based on other numerical models, experiment results, and generalized formula for dynamic active earth pressure. We also determined the damage state and damage index based on the height of retaining wall, and developed the seismic fragility curves. The damage probabilities of the retaining wall for the S4 site were computed to be larger than those for the S2 site.

Determination of filtering condition and threshold for detection of Gait-Cycles under Various Gait Speeds and Walkway Slopes (다양한 보행속도와 경사각에 대한 보행수 검출을 위한 필터링 조건과 역치의 결정)

  • Kwon, Yu-Ri;Kim, Ji-Won;Lee, Jae-Ho;Tack, Gye-Rae;Eom, Gwang-Moon
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.516-520
    • /
    • 2009
  • The purpose of this study is to determine optimal filtering condition and threshold for the detection of gait-cycles for various walkway slopes as well as gait velocities. Ten young healthy subjects with accelerometer system on thigh and ankle walked on a treadmill at 9 conditions (three speeds and three slopes) for 5 minutes. Two direction signals, i.e. anterior-posterior (AP) and superior-inferior (SI) directions, of each sensor (four sensor orientations) were used to detect specific events of gait cycle. Variation of the threshold (from -1G to 1G) and lowpass cutoff frequency (fc) were applied to the event detection and their performance was evaluated according to the error index (EI), which was defined as the combination of the accuracy and false positive rate. Optimal fc and threshold were determined for each slope in terms of the EI. The optimal fc, threshold and their corresponding EI depended much on the walkway slope so that their coefficients of variation (CV) ranged 19~120%. When all data for 3 slopes were used in the identification of optimal conditions for each sensor, the best error indices for all sensor orientations were comparable ranging 1.43~1.76%, but the optimal fc and threshold depended much on the sensor position. The result indicates that the gait-cycle detection robust to walkway slope is possible by threshold method with well-defined filtering condition and threshold.

The Difference in the Smoothness of the Movement according to Shoe, Velocity, and Slope during Walking (보행시 신발, 속도, 경사도에 따른 동작의 부드러움 차이)

  • Choi J.S.;Tack G.R.;Yi J.H.;Lee B.S.;Chung S.C.;Sohn S.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.169-170
    • /
    • 2006
  • The purpose of this study was to evaluate the smoothness of the gait pattern according to shoe, walking speed, and slope. Eleven male university students used three types(running shoes, mounting climbing boots, elevated forefoot walking shoes) of shoes at various walking speeds(1.19, 1.25, 1.33, 1.56, 1.78, 1.9, 2.0, 2.11, 2.33m/s) and gradients (0, 3, 6, 10%) on a treadmill. Three-dimensional motion analysis (Motion Analysis Corp, Santa Rosa, CA, USA) was conducted with 4 Falcon high speed cameras. The results showed that elevated forefoot walking shoes had the lowest value of normalized jerk at the heel, which means that elevated forefoot walking shoes had the smoothest walking pattern at the heel. In contrast, elevated forefoot walking shoes had greater normalized jerk at the center of mass (COM) at most walking speeds, which means that the smoothness of gait pattern at the center of mass is the lowest for the elevated forefoot walking shoes. This movement at the COM might even have a beneficial effect of activating muscles in the back and abdomen more than other shoes.

  • PDF

Analysis of Response Characteristics According to Permanent Displacement in Seismic Slope (지진시 비탈면의 영구변위 발생에 따른 응답특성 분석)

  • Ahn, Jae-Kwang;Park, Sangki;Kim, Wooseok;Son, Su-Won
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.12
    • /
    • pp.135-145
    • /
    • 2019
  • The slope collapse can be classified into internal and external factors. Internal factors are engineering factors inherent in the formation of slopes such as soil depth, slope angle, shear strength of soil, and external factors are external loading such as earthquakes. The external factor for earthquake can be expressed by various values such as peak ground acceleration (PGA), peak ground velocity (PGV), Arias coefficient (I), natural period (Tp), and spectral acceleration (SaT=1.0). Specially, PGA is the most typical value that defines the magnitude of the ground motion of an earthquake. However, it is not enough to consider the displacement in the slope which depends on the duration of the earthquake even if the vibration has the same peak ground acceleration. In this study, numerical analysis of two-dimensional plane strain conditions was performed on engineered block, and slope responses due to seismic motion of scaling PGA to 0.2 g various event scenarios was analyzed. As a result, the response of slope is different depending on the presence or absence of sliding block; it is shown that slope response depend on the seismic wave triggering sliding block than the input motion factors.

Effects of Cheonggukjang Diet and Aerobic Exercise on Lipid Metabolism and Antioxidant Enzyme in Rats (청국장 식이와 유산소 운동이 흰쥐의 지질대사 및 항산화효소에 미치는 영향)

  • Kim, Sang-Woo;Jeong, Seon-Tea;Baek, Yeong-Ho
    • Journal of Life Science
    • /
    • v.23 no.5
    • /
    • pp.657-663
    • /
    • 2013
  • The purpose of this study was to examine the effects of a cheonggukjang diet and aerobic exercise on lipid metabolism and antioxidant enzyme activity in rats. Thirty-two Sprague Dawley rats were randomized into a cheonggukjang diet with aerobic exercise (A), aerobic exercise (B), cheonggukjang diet (C), and control group (D). The cheonggukjang diet group consumed 20 g of 20% cheonggukjang a day with their normal diet. Exercise training consisted of treadmill running (25~40 min, 5 day/wk) and the exercise intensity was gradually increased. The results are as follows: T-C was significantly lower (p<0.05) in A compared to B and C. TG was significantly lower (p<0.001) in A compared to D. B and C were significantly lower than D. HDL-C was significantly higher (p<0.05) in C compared to D. LDL-C was not statistically different across the groups. Additionally, TBARS were not statistically different in the control or experimental groups. SOD was significantly lower (p<0.05) in A compared to D. C was significantly lower (p<0.05) that of D. CAT and GPx failed to reach the statistical difference between experimental and control groups. The major findings of this study were that aerobic exercise with a chenggukjang diet intervention improved lipid profiles and antioxidant capacity in this animal model. Therefore, a cheonggukjang diet and aerobic exercise will help to improve antioxidant capacity and prevent lifestyle related diseases.

An appropriateness review on the road tunnel ventilation standards by pollutants site measurement and case study (오염물질 현장측정 및 사례조사를 통한 도로터널 환기기준의 적정성에 관한 연구)

  • Kim, Hyo-Gyu;Baek, Doo-San;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.3
    • /
    • pp.323-335
    • /
    • 2020
  • In this study, a series of site measurement of particulate and gases pollutants at five tunnels were carried out along with case studies to review the suitability of the current road tunnel ventilation design standards. Previous studies by other researchers have shown that the ratios of the level of measurement to the standard were 27.9%, 1.6% and 3.4% for TSP, CO and NOx, respectively. Those measured in this site study shows even lower ratios; the ratios were 2.6%, 0.8% and 0.3%, for TSP, CO and NOx, respectively. The particle size analysis of TSP for the five tunnels shows that PM10 including tire wear and re-suspended road dust exceeded 20.4%. This implies that non-exhaust particulate matter must be taken into account, since the current design standards for the particulate matter (visibility) include only the engine emission. Based on the recent research results, for vehicle emission rate and slope-speed correction factors, revision of ventilation design standards for pollutants is required. WRA (PIARC) also emphasizes the necessity of the ventilation design standards for pollutants. In addition, enactment of a new road tunnel ventilation system operation standard or guideline is strongly recommended when considering the low operating rate of the ventilation system with jet-fans.

Lung Clearance of Inhaled $^{99m}Tc$-DTPA by Urine Excretion Ratio (소변내 방사능배설량비를 이용한 $^{99m}Tc$-DTPA 폐청소율에 관한 연구)

  • Suh, G.Y.;Park, K.Y.;Jung, M.P.;Yoo, C.G.;Lee, D.S.;Kim, Y.W.;Han, S.K.;Jung, J.K.;Lee, M.C.;Shim, Y.S.;Kim, K.Y.;Han, Y.C.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.357-366
    • /
    • 1993
  • Background: Lung clearance of inhaled $^{99m}Tc$-DTPA reflects alveolar epithelial permeability and it had been reported as more sensitive than conventional pulmonary function tests in detecting lung epithelial damage. However, measuring lung clearance of inhaled $^{99m}Tc$-DTPA by gamma camera may not always reflect alveolar epithelial permeability exactly because it is influenced by mucociliary clearance depending on the site of particle deposition. Moreover, this method takes much time and patient's effort because he has to sit or lie still in front of the camera for a prolonged period. Most of the absorbed DTPA is excreted in urine within 24 hours and the amount of excreted DTPA in urine during the first few hours after inhalation is influenced by absorption rate which is correlated with the alveolar-epithelial permeability suggesting that the urinary excretion, especially in first few hours, may be an alternate index for lung clearance. The purpose of this study was to evaluate the usefulness of ratio of excreted $^{99m}Tc$-DTPA in 2 hour and 24 hour urine as an index of alveolar-epithelial damage. Methods: Pulmonary function tests including diffusing capacity and lung clearance of $^{99m}Tc$-DTPA measured by gama camera ($T_{1/2}$) and 2hr/24hr urine excretion ratio (Ratio) of inhaled $^{99m}Tc$-DTPA in 8 normal subjects and 14 patients with diffuse interstitial lung disease were compared. Results: 1) In the normal control, there was significant negative correlation between the $T_{1/2}$ and the Ratio (r=-0.77, p<0.05). In patients with diffuse interstitial lung disease, there also was significant negative correlation between $T_{1/2}$ and Ratio(r=-0.63, p<0.05). 2) In diffuse interstitial lung disease patients, the $T_{1/2}$ was $38.65{\pm}11.63$ min which was significantly lower than that of normal control, $55.53{\pm}11.15$ min and the Ratio was $52.15{\pm}10.07%$ also signifantly higher than that of the normal control, $40.43{\pm}5.53%$ (p<0.05). 3) There was no significant correlations between $T_{1/2}$ or Ratio and diffusing capactiy of lung in both patients and controls (p>0.05). Conclusion: These results suggests that 2hr/24hr urine excretion ratio of inhaled $^{99m}Tc$-DTPA is a useful simple bedside test in assessing alveolar epithelial permeability and that it may be used as an additive follow-up test in patients with diffuse interstitial lung disease complementing conventional pulmonary function tests.

  • PDF