• Title/Summary/Keyword: 소형차 전용 지하도로

Search Result 7, Processing Time 0.018 seconds

A study on the development and applicability of fire risk assessment method for small road tunnels passing only small cars (소형차 전용 도로터널의 화재 위험도 평가기법개발 및 적용성에 관한 연구)

  • Ryu, Ji-Oh;Choi, Pan-Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.917-930
    • /
    • 2018
  • A quantitative risk assessment method for quantitatively evaluating the fire risk in designing a road tunnel disaster prevention facilities has been introduced to evaluate the appropriateness of a disaster prevention facility in a large tunnel through which all vehicle types pass. However, since the quantitative risk assessment method of the developed can be applied only to the large sectional area tunnels (large tunnels), it is necessary to develop a quantitative risk assessment method for road tunnels passing only small cars which has recently been constructed or planned. In this study, fire accidents scenarios and quantitative risk assesment method for small road tunnels through small cars only which is based on the methods for existing road tunnels (large tunnels). And the risk according to the distance between cross passage is evaluated. As a result, in order to satisfy the societal risk assessment criteria, the distance of the appropriate distance between cross passages was estimated to be 200 m, and the effect of the ventilation system of the large port exhaust ventilation system was quantitatively analyzed by comparing the longitudinal ventilation system.

A Case Study on M & E Design for Double-Deck Tunnel in Urban Area (도심지 대심도 복층터널의 환기 및 방재계획)

  • Byun, Sang-Hun;Jeong, Jae-Ho;Jun, Duk-Chan;Shin, Il-Jae;Sim, Dong-Hyun
    • Tunnel and Underground Space
    • /
    • v.21 no.4
    • /
    • pp.281-286
    • /
    • 2011
  • The west underground express way is a recent initiated BTO (Build-Transfer-Operate) project for releasing heavy traffic of the existing west express way which is notorious on-ground road for extremely traffic stuck area in the west of Seoul, South Korea. The new express way for light vehicles is the first double-deck tunnel ever designed in South Korea and 10.91 km long including both open cut structures and concrete lining with middle-deck in bored tunnel. Because the new express way is going through underground of heavily populated area, mechanical & electrical design for the safety of drivers in tunnel is one of the most important parts among many design issues. This paper discusses M & E design focuses including ventilation-evacuation plan and various safety facilities.

A study on the ventilation control method of road tunnel for small vehicles (소형차 전용 도로터널의 환기기 제어방안에 대한 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young;Chang, Ji-Don
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.749-762
    • /
    • 2019
  • In recent years, in urban areas, underground of roads are being promoted in order to resolve traffic congestion and to secure green spaces, and due to the low ratio of large vehicles, they are planned or constructed as road tunnels for small cars only. In addition, the tunnels being built in the city is a tendency to be enlarged to play the role of main roads. Accordingly, the capacity of the ventilation system is increasing and various ventilation methods are required, and the importance of maintenance after the completion of the tunnel such as the operating cost of the ventilation system is emphasized. Therefore, the need for optimization of the operation stage for reducing the power consumption of the ventilation system and the study of the ventilation system operation control logic is increasing. In this study, the study on the necessity of the optimization of operation stage and control logic of the ventilation system was carried out to realize the energy-saving operation for the small car only passing through tunnels which is applied of ① jet fan and combination ventilation system (② jet fan + air purifying equipment, ③ jet fan + vertical shaft, ④ jet fan + supply air semi-transverse). As a result of this study, there can be various operating combinations in the case of the combined ventilation system, and even though the amount of ventilation air is the same, the operating power varies greatly according to the operating combinations. It was found that operating the axial fan first rather than the jet fan first operation method has an effect on power saving.

A evaluation study of a fire smoke diffusion delay device installed in a great depth underground double deck tunnel (대심도 복층터널에 설치 가능한 화재연기 확산지연장치 성능 평가 연구)

  • Shin, Tae-Gyun;Moon, Jung-Joo;Yang, Yong-Won;Lee, Yun-Taek
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.225-234
    • /
    • 2018
  • Domestic urban areas are experiencing serious traffic congestion problems due to continuous population growth and increased traffic volume. In order to solve the problem of traffic congestion, the study of great depth underground double deck tunnels using underground space is being actively carried out in the urban areas. The characteristics of great depth underground double deck tunnels are low in cross section, so the spread of fire smoke is expected to spread faster than the road tunnel in case of fire. Therefore, it is necessary to provide a fire smoke delay device which delays the spread of fire smoke when a fire occurs in a tunnels. In the previous study, the diffusion effect was analyzed according to the blocking area when the fire smoke spread delay device was operated through the 3D CFD in the study of preventing the smoke spread in the case of the tunnel fire. A study on fire smoke diffusion delay device using spring elasticity which is excellent in applicability to a tunnel and economical value is studied. In this study, fire smoke spread delay system was developed to fire smoke delay was experimentally analyzed. Fire smoke delay effect of fire smoke delay device appeared. Therefore, it is considered that the can minimize the damage of the victims when installed in the great depth underground double deck tunnels.

A study on the fire characteristics according to the installation type of large smoke exhaust port in a small cross sectional tunnel fire (소단면 대심도 터널 화재시 대배기구의 설치형태에 따른 화재특성 연구)

  • Choi, Pan-Gyu;Baek, Doo-San;Yoo, Ji-Oh;Kim, Chang-Yong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.201-210
    • /
    • 2019
  • Recently, due to the efforts to mitigate traffic congestion and expansion of space efficiency, the construction of underground roads has been increased in big-scale cities. Since tunnels in the city have a higher chance for a fire leading to a great tragedy during a severe traffic jam than mountain tunnels, it is highly likely that it will be constructed as a tunnel, having a small cross section, for small vehicles. However, if they are constructed as such small-vehicle tunnels, it would be possible to reduce the design fire intensity while the concentration of harmful gases would increase due to a reduction in the small cross sectional area, led by a decrease in the tunnel height. In this study, behaviors of fire smoke by the installation interval and format of large-scale exhaust-gas ports were examined and compared in the analysis of temperatures and CO concentrations of a tunnel and its results were as the following. Although there were no significant differences in the smoke spreading distance between installation intervals, but in this study, 100 m was found to be the most effective installation interval. The smoke exhaustion performance was found to be excellent in the order of $4m{\times}3m$, $6m{\times}2m$, and $3m{\times}2m$ (2 lane) of the smoke spreading distance. Although there was no significant difference in the smoke spreading distance between formats of large-scale exhaust-gas ports, it was found that the smoke spreading distance was larger than other cases when it was $3m{\times}2m$ in the fire growing process. The analysis of smoke spreading distances by the aspect ratio showed that a smoke spreading distance was shorted when its the smoke spreading distance was found to be shorter when its traverse distance was relatively longer than its longitudinal distance.

A study on the design and applicability of stereoscopic sign for improving the visibility of traffic sign in double-deck tunnel (복층터널 교통표지판 시인성 향상을 위한 입체표지판 설계 및 적용 가능성에 대한 연구)

  • Park, Sang-Heon;Hwang, Ju-Hwan;Han, Sang-Ju;An, Sung-Joo;Kim, Hoon-Jae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.899-915
    • /
    • 2018
  • In this study, in order to construct an eco-friendly advanced road transportation network, the multi-layer tunnel, which is a small-sized car road, is designed to have a height of less than 60 cm. However, the shape of the tunnel is low and the height of the traffic sign is small. In order to solve these problems, traffic sign characters were designed in three dimensions, and the possibility of applying the design of the three - dimensional sign that can obtain greater visibility than the existing signs at the same distance and the possibility verification through virtual simulation were performed. The three-dimensional sign is horizontally installed on the ceiling of the multi-layer tunnel. To be seen vertically, it is enlarged by a certain ratio by the perspective, and the width and height are enlarged. Respectively. In addition, 3D simulation was performed to verify the visibility of the stereoscopic signs when the driver ran through the stereoscopic sign design specifications. As a result of the design and experimental study, it was confirmed that the stereoscopic sign could be designed through the theoretical formula and that it could provide the driver with a larger traffic sign character because there is no limitation of the facility limit compared to the existing vertical traffic sign. Also, we confirmed that it can be implemented in the side wall by using the stereoscopic sign design principle installed on the ceiling part. It was confirmed that the design of the stereoscopic sign can be designed to be smaller as the distance that the driver visually recognizes the sperm is shorter, the height of the protrusion vertically at the lower part of the stereoscopic sign becomes higher. As a result of 3D simulation running experiment based on the design information of the stereoscopic sign, it was confirmed that the stereoscopic sign is visually the same as the vertical sign at the planned distance. Although the detailed research and institutional improvement of stereoscopic signs have not been made in Korea and abroad, it is evolved into a core technology of new road traffic facilities through various studies through the possibility of designing and applying stereoscopic signs developed through this study Expect.

A Study on the Inflow Velocity Reduction Measures in Case of Fire Great Depth Underground Double-Deck Tunnel (대심도 복층터널 화재 시 유입풍속 저감방안 연구)

  • Yang, Yong-Won;Moon, Jung-Joo;Shin, Tae-Gyun
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Recently, frequent traffic congestion has occurred in domestic urban roads. As a solution for downtown traffic congestion in domestic urban roads, plans for great depth underground double-deck tunnels have been made. Great depth underground double-deck tunnels that have been planned for passenger cars, has the structure of a network type; the entry of vehicles is carried out in the underground space. In these network great depth underground double-deck tunnels, the cross section and the height of the tunnel are smaller than the general road tunnel, and the smoke of a fire will propagate faster than the evacuation of tunnel passengers by the action of the traffic-ventilation and casualties are expected. Therefore, in the present study, an attempt was made to prevent the delay system for fire smoke diffusion at the time of a fire in a domestic network great depth underground double-deck tunnel according to the area of the tunnel block during the operation of the delay system for fire smoke diffusion to analyze the effects of reducing the inflow velocity. When the area of the tunnel block was not less than 50%, the effect of reducing about 21% of the wind speed acting on the tunnel was significant. If the area is more than 50%, the diffusion rate of fire smoke was reduced by approximately 21%, which will be useful for a safe evacuation.