• Title/Summary/Keyword: 소형선

Search Result 587, Processing Time 0.025 seconds

A Study on the Revitalization Strategy for Inter-Korean Railway by Building the Railway Logistics Depot - Focused on the Donghae Line - (철도 물류기지 구축을 통한 남북철도 활성화 방안 연구 - 동해선을 중심으로 -)

  • Kim, Young-Min;Cho, Chi-Hyun
    • Journal of Distribution Science
    • /
    • v.8 no.2
    • /
    • pp.5-12
    • /
    • 2010
  • The allotment rate for railway transportation keeps an yearly 6% in Korea. However, the railway logistics will cause the opposite result according to the continuous investment and logistics rationalization. The study on railway logistics as well as inter-Korean railway that might highly contribute to the development of railway logistics is not enough at all. The purpose of this paper is to study the revitalization strategy for inter-Korean railway by forecasting the demand and the scale of railway logistics depot. The revitalization strategies for inter-Korean railway through railway logistics depot are as followings. First, it is necessary to strengthen the partnership with coal user in the logistics depot. Second, it is encouraged to provide the financial assistance that are needed in the maintenance of the decrepit North Korea's track as well as the establishment of Donghae northern line that is from Gangneung to Jejin. Third, the railway cost on long/short transportation and large sized shipper is needed to apply in a flexible way. Fourth, it is necessary to obtain the railway traffic right by involving the foreign mining development. Fifth, it is encouraged to constantly find the small sized shipper like cement company.

  • PDF

Image Processing Based Virtual Reality Input Method using Gesture (영상처리 기반의 제스처를 이용한 가상현실 입력기)

  • Hong, Dong-Gyun;Cheon, Mi-Hyeon;Lee, Donghwa
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.5
    • /
    • pp.129-137
    • /
    • 2019
  • Ubiquitous computing technology is emerging as information technology advances. In line with this, a number of studies are being carried out to increase device miniaturization and user convenience. Some of the proposed devices are user-friendly and uncomfortable with hand-held operation. To address these inconveniences, this paper proposed a virtual button that could be used in watching television. When watching a video on television, a camera is installed at the top of the TV, using the fact that the user watches the video from the front, so that the camera takes a picture of the top of the head. Extract the background and hand area separately from the filmed image, extract the outline to the extracted hand area, and detect the tip point of the finger. Detection of the end point of the finger produces a virtual button interface at the top of the image being filmed in front, and the button activates when the end point of the detected finger becomes a pointer and is located inside the button.

Compact Tri-Band Bandpass Filter Using Dual-Mode Stepped-Impedance Resonators and Parallel Coupled-Lines (이중 모드 SIR과 평행 결합선로를 이용한 소형 3중-대역 대역통과 필터 설계)

  • Gyuje Sung;Young Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.1
    • /
    • pp.57-62
    • /
    • 2023
  • This paper proposes a tri-band bandpass filter using dual-mode stepped-impedance resonators (SIRs) with parallel coupled structures. The proposed filter adopts U-shaped SIRs with open stubs and parallel coupled lines (PCLs) that have inter-digital and comb-line shorted ends. Two U-shaped SIRs with open stubs build the first and third passband, and the central PCL resonators build the second passband. Five resonators and coupling structures are theoretically analyzed to derive the scattering parameters of the proposed filter. A novel tri-band bandpass filter is designed and fabricated using the induced scattering parameters. The measured result of the fabricated tri-band bandpass filter shows a good agreement with the simulated one.

Implementation of a portable pulse oximeter for SpO2 using Compact Flash Interface (컴팩트 플래쉬 방식의 휴대용 산소포화도 측정 시스템 구현)

  • Lee, Han;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.678-681
    • /
    • 2003
  • In this paper, we aims to develop a microcontroll er-based portable pulse oximeter using Compact Flash Interface. First, portable pulse oxineter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of SpO$_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patients condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO$_2$ modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact flash interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF

Determination of Beam Quality Correction Factors for the PTW-Markus Chamber for Electron Beam Qualities R50=1.0 and 1.4 g/cm2 (전자선 선질 R50=1.0과 1.4 g/cm2에 대한 PTW-Markus 전리함의 선질보정인자 결정에 관한 연구)

  • Kim, Me Young;Rhee, Dong Joo;Moon, Young Min;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.178-184
    • /
    • 2015
  • The Markus ionization chamber(R) is a small plane parallel ionization chamber widely used in clinical electron beam dosimetry. Plane parallel chambers were recommended for low energy electron dosimetry with the beam quality at $R_{50}<4.0g/cm^2$ (${\bar{E}}{\approx}10MeV$) according to TRS-398 protocol. However, the quality correction factors ($k_{Q,Q_0}$) of the Markus chamber was not presented in TRS-398 protocol for electron beam quality at $R_{50}<2.0g/cm^2$ (${\bar{E}}{\approx}4MeV$). In this study, the $k_{Q,Q_0}$ factors of the Markus chambers (PTW-34045) for beam qualities at $R_{50}=1.0$, 1.4, 2.0, 2.5, 3.0, and $5.0g/cm^2$ were determined by Monte Carlo calculations (DOSRZnrc/EGSnrc) and the dosimetric formalism of quality correction factor. The derived $k_{Q,Q_0}$ values were evaluated using the produced data based on TRS-398 and TG-51 protocols and known values for the Markus chamber.

Study on the Evaluation of TRS-398 Quality Factors with Central Electrode Corrections for Small Cylindrical Chambers (소형 전리함에 대한 TRS-398 선질인자 계산과 중심전극 보정에 관한 연구)

  • Kang, Yeong-Rok;Lee, Chang-Yeol;Kim, Jin-Ho;Moon, Young-Min;Kwak, Dong-Won;Kang, Sang-Koo;Kim, Jeung-Kee;Yang, Kwang-Mo;Jeong, Dong-Hyeok
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.148-154
    • /
    • 2011
  • The quality factors ($k_{Q,Q_0}$) were evaluated by appling the results recently studied for the effect of central electrode in TRS-398 protocol. The PTW-31010 and IBA-CC13 chambers were used in this study. The quality factors were calculated as a function of beam quality for high energy electron and photon beams and compared with data currently used in TRS-398 protocol. In the PTW-31010 chamber using aluminium electrode, appling the new central electrode collections, the quality factors were 0.4% and 0.9% higher than current TRS-398 data for high energy photon and electron beams respectively. In the IBA-CC13 chamber using C-552 electrode, there are no variations in quality factors compared to TRS-398 data currently used.

A Study on Image Acquisition of Gamma Camera using Simulation LUT and MLPE (시뮬레이션 순람표와 최대우도함수를 이용한 감마카메라의 영상 획득 연구)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.409-414
    • /
    • 2021
  • In order to acquire an image from a gamma camera, linearity correction must be performed. To this end, digital coordinates are acquired by using a linearity map to accurately specify the location where the scintillator and gamma rays interact. In this study, a method for acquiring undistorted images and digital coordinates was developed using a lookup table and maximum likelihood position estimation without using a linearity map. The proposed method was verified by configuring a small gamma camera through DETECT2000 simulation. A gamma camera was constructed using a GAGG scintillator and a SiPM optical sensor, and a gamma-ray interaction was generated at the center of the scintillator, and a lookup table was prepared using the ratio of the signals obtained from the SiPM. Through the prepared lookup table and the maximum likelihood position estimation, the position of the signal obtained by the gamma-ray interaction was acquired as digital coordinates to compose an image. As a result, the linearity was maintained compared to the generally acquired image, the accuracy of the location where the gamma-ray interaction was generated was excellent, and the distance between the locations was uniform. Since the lookup table obtained through simulation is created using the ratio of the signal, it can be directly used in the experiment, and the position of the signal can be conveniently obtained with digital coordinates with corrected linearity without creating a linearity map.

Investigation of the Signal Characteristics of a Small Gamma Camera System Using NaI(Tl)-Position Sensitive Photomultiplier Tube (NaI(Tl) 섬광결정과 위치민감형 광전자증배관을 이용한 소형 감마카메라의 신호 특성 고찰)

  • Choi, Yong;Kim, Jong-Ho;Kim, Joon-Young;Im, Ki-Chun;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Joo, Koan-Sik;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.82-93
    • /
    • 2000
  • Purpose: We characterized the signals obtained from the components of a small gamma camera using Nal(Tl)-position sensitive photomultiplier tube (PSPMT) and optimized the parameters employed in the modules of the system. Materials and Methods: The small gamma camera system consists of a Nal(Tl) crystal ($60{\times}60{\times}6mm^3$) coupled with a Hamamatsu R3941 PSPMT, a resister chain circuit, preamplifiers, nuclear instrument modules (NIMs), an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a resistive charge division circuit which multiplexes the 34 cross wire anode channels into 4 signals (X+, X-, Y+, Y -). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated and digitized via triggering signal and used to localize the position of an event by applying the Anger logic. The gamma camera control and image display was performed by a program implemented using a graphic software. Results: The characteristics of signal and the parameters employed in each module of the system were presented. The intrinsic sensitivity of the system was approximately $8{\times}10^3$ counts/sec/${\mu}Ci$. The intrinsic energy resolution of the system was 18% FWHM at 140 keV. The spatial resolution obtained using a line-slit mask and $^{99m}Tc$ point source were, respectively, 2.2 and 2.3 mm FWHM in X and Y directions. Breast phantom containing $2{\sim}7mm$ diameter spheres was successfully imaged with a parallel hole collimator. The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We proposed a simple method for development of a small gamma camera and presented the characteristics of the signals from the system and the optimized parameters used in the modules of the small gamma camera.

  • PDF

Fire Alarm Solutions Through the Convergence of Image Processing Technology and M2M (영상처리기술과 M2M의 융합을 통한 화재 경보 솔루션)

  • Kang, Bo-Seon;Lee, Keun-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.1
    • /
    • pp.37-42
    • /
    • 2016
  • Recent advances have been made in technology of sensor devices. Accordingly, the size of devices has been miniaturized, to which diverse functions can be applied. On top of that, the devices use image processing technology to observe circumstances of users' living spaces and detect risk situations saved in database. In case of detecting risk situations, M2M environment is constructed so that the information can be delivered to other communication devices to immediately raise an alarm. This paper aims to introduce solutions that construct M2M environment by using color detection algorithm of OpenCV and Raspberry Pi, raise an alarm to users in case of fire, and provide information on follow-up measures for it.

A Study on the Alternatives Evaluation of the Fishing Boat in the Small Powered Purse Seine (소형선망어업 시험선 운영의 경제성 평가에 관한 연구)

  • 이승우
    • The Journal of Fisheries Business Administration
    • /
    • v.29 no.2
    • /
    • pp.163-175
    • /
    • 1998
  • The decrease of the fishery's business performance is due to the changes of environment-the increase of cost, the reduction of resources, the liberalization of import, the effectuation of the admiralty law Though the government has prepared the alternative policy to strengthen the competitive power of the fishery, fishermen should draw up a plan to improve the business performance. The problems of the small powered purse seine resulting from the small scale of the fishing boat is following. First, its catching activity in the sea is riskful. Second, the space to eat and to work is not enough. Third, the space to put the fish is not enough, it is hard to maintain the freshness of the fish. Therefore it is necessary to solve these problems for the scale of the fishing boat to have to be enlarged. The enlargement of the fishing boat to be required much expenditure of fund is the important investment decision to fishermen. The alternatives evaluation between the existing boat(defender) and the new boat enlarged with the new equipment(challenger) is necessary process to reduce the uncertainty of investment. The profitability of the challenger is better than that of defender due to the reduction of cost and the increase of revenue. Because the net present value of incremental cash flow is positive, it is rational for fishermen to accept the challenger.

  • PDF