• Title/Summary/Keyword: 소프트 스위칭

Search Result 327, Processing Time 0.022 seconds

Soft-Switching Half-Bridge Converter using Secondary Switches for Output Control and Conduction Loss Reduction (출력제어와 도통손실 감소를 위해 2차측 스위치를 사용한 소프트스위칭 하프브리지 컨버터)

  • 김영필;김진우;김태웅;이성백
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.103-106
    • /
    • 2001
  • In this paper, a soft switching half-bridge converter using secondary switches for output control and conduction loss reduction is proposed. The conventional half-bridge converter must be fixed on duty cycle for soft switching. The proposed converter was consisted of two added switches in series of the secondary rectifier diodes. The main switches with constant duty cycle are operated ZVS. The secondary switches are operated ZV-ZCS. Especially, the primary switches were fixed duty cycle for maximum voltage conversion ratio. Output of converter is controlled by duty cycle or phase-shifted time of secondary switches. The conduction loss of the proposed converter can be reduced by the secondary switches. The operation characteristic, analysis, simulation and experimental results of the proposed converter are presented.

  • PDF

A New Soft Switching DC-DC Converter using Two Transformers (두 개의 변압기를 이용한 새로운 소프트 스위칭 방식의 DC-DC 컨버터)

  • Lee Darl-Woo;Ahn Tae-Young
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.9
    • /
    • pp.444-449
    • /
    • 2005
  • This paper proposes the new soft switching DC-DC converter. We reported the experimental results of the new soft switching DC-DC converter. The proposed converter is to resonate between the leakage inductance of the transformer and the parasitic capacitances of the main switches for zero voltage switching. The voltage stresses of the two switches are the input voltage, it can improve the efficiency and a reduced height used two transformers. Theoretical analysis of the converter along with experimental results is provided. Finally, a 3.3V/20A prototype converter operation at 100kHz is built and experimental waveform verifies the analysis.

A Design of Converter using Bi-directional Partial Resonant Soft-Switching (양방향 부분공진 소프트 스위칭을 적용한 컨버터 회로 설계)

  • Yun, S.H.;Kim, C.S.;Suh, K.Y.;Lee, H.W.;Kim, K.T.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.212-214
    • /
    • 2001
  • This paper proposes a hi-directional current switch with snubber regeneration using Power MOSFETs and to use a loss-less snubber with switching device to perform soft-switching. It results in not only decreasing switching loss in the device drastically, but also improving input ac current waveform distortion. The computer simulation results show that the input current waveform and show the requirements necessary for the elimination of the 3rd harmonic component. We also show the Procedure to design the parameters of the converter.

  • PDF

A New Soft Switching Technique for Bi-directional Power Flow, Full-bridge DC-DC Converter (양방향 풀-브릿지 DC-DC 컨버터를 위한 새로운 소프트 스위칭 기법)

  • Song, Y.J.;Park, S.I.;Jeong, H.G.;Han, S.B.;Jung, B.M.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.251-255
    • /
    • 2005
  • This paper proposes a new soft switching technique for a phase-shift controlled bi-directional DC-DC converter. The described converter employs a low profile high frequency transformer and two active full-bridge converters for bidirectional power flow capability. A new soft switching technique is proposed, which guarantees soft switching over wide range (no load to full load) without any additional circuit components. In the proposed switching scheme, the switch pairs in the diagonal position of the converter each are turned on/off simultaneously by the switching signals with a variable duty ratio depending on the phase shift amount, and the converter is operated without freewheeling interval.

  • PDF

Topology of a soft switching high frequency insulatied PWM DC-DC converter (고주파 절연형 소프트 스위칭 PWM DC-DC 컨버터의 토폴로지)

  • Lee, S.H.;Kwon, S.K.;Suh, K.Y.;Lee, H.W.;Mun, S.P.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.383-386
    • /
    • 2005
  • In this paper, proposed new partial resonance ZCS PWM controlled High frequency insulated Full-bridge DC-DC converter not using exciting current of high frequency transformer. It is compared with the existing principles in characteristics. It also realizes a widely stabilized ZVS operating using new ON-OFF control method at synchronized power rectification MOSFET of high frequency insulated transformer secondary. Besides, it is brought over 97[%] measurement efficiency by proposed DC-DC converter.

  • PDF

Design of A 2KW Soft-Switching ZVT Power Factor Correction Converter with Active Snubbers (능동 스너버를 갖는 2KW 소프트 스위칭 ZVT 역률 보정 컨버터 설계)

  • Park Kyoung-Soo;Kim Yoon-Ho;Park Kyoung-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.677-680
    • /
    • 2001
  • In this paper a soft switching ZVT power factor converter using active snubbers is designed to improve efficiency and reduce voltage spike and parastic ringing. The main switch achieves ZVT and the auxiliary switch performs with ZCS. A 2KW soft switching ZVT converter is designed with switching frequency 100kHz, output voltage 400VDC. Then the designed system is realized and experimental results shows that the measured efficiency and power factor were over $97.45\%$ and 0.997 respectively with an input current THD less than $3\%$.

  • PDF

The new Soft-Switching AC-DC Boost Type Converter using Lossless Snubber (무손실 스너버회로를 이용한 새로운 소프트 스위칭 AC-DC승압형 컨버터)

  • Mun Sang-Pil;Suh Ki-Young;Kim Young-Mun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1226-1228
    • /
    • 2004
  • A novel lossless passive snubber is proposed for soft switching the boost type converters. The proposed snubber does not use any auxiliary switches. but uses two identical snubber capacitors which are charged in parallel at turn off of the main switch and discharged in series at turn on automatically, and the discharged energy is recovered effectively (more than $95[\%]$ recovery) into the output capacitor. Thus, the snubber provides zero voltage switching for the converter main switch, reducing both the turn off losses and the electromagnetic interference(EMI) noise, whitch improves the converter performance. The experimental results of a 20[kHz] 600[W] DC-DC boost converter and a single-phase AC-DC boost rectifier with the new snubber are presented.

  • PDF

Analysis, Design and Experimental Comparison of 2㎾ Power Factor Corrector Converters With Soft-Switching Methods (소프트 스위칭 방식을 갖는 2㎾ PFC 컨버터의 분석 설계 및 실험 비교)

  • Park, Gyeong-Su;Kim, Yun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.9
    • /
    • pp.537-544
    • /
    • 2002
  • This paper describes a comparative analysis of soft switching boost converters through design, production and experiment. Soft switching boost converters are designed to satisfy the condition of input voltage 170-265Vac, output voltage 400Vdc, output current 5A, output power 20W-2000W and unit power factor. In addition, parameter values are designed so that system operation can be compared under this is similar conditions. The efficiency of the combined inductor soft switching boost converter was 97.63% with 1011 load better than that of other boost converter types. The combined inductor soft switching converter has simple circuit construction and low switching loss. EMI resulted by the switching noise, and harmonic distortion.

Analysis on power loss of three-phase soft switching inverter (3상 소프트 스위칭 인버터의 전력손실에 관한 해석)

  • Kim, J.Y.;Mun, S.P.;Kim, Y.S.;Suh, K.Y.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.3-5
    • /
    • 2002
  • This paper proposes a new prototype auxiliary resonant DC link(ARDCL)snubber circuit and deals with its power loss on the basis of actually measured conduction loss characteristic of switching device module. Voltage-type soft switching three phase inverter using proposed ARDCL snubber circuit is presented along with its performance evaluations. And, the power loss analysis of three phase hard and soft switching inverter are carried out from the point of simulation and experimental results.

  • PDF

Soft Switching Buck Converter Using Non-dissipative Snubber (탭-인덕터적용 무손실 스너버에의한 소프트스위칭 Buck 컨버터)

  • Kim E. S.;Park S. S.;Gong Y. S.;Choi S. H.;Kang D. H.;Joe K. Y.;Lee J. S.
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.133-136
    • /
    • 2002
  • This paper presents m improved soft switching Buck converter using an energy recovery snubber which is composed of a tapped inductor, two snubber capacitors and three snubber diodes. The proposed Buck converter achieves zero voltage turn-of in the main power switch md freewheeling diode. The operating Principle of the Proposed Buck converter is described through the simulation, relevant equation and analysis.

  • PDF