• Title/Summary/Keyword: 소프트 스위칭

Search Result 327, Processing Time 0.022 seconds

High Frequency Soft Switching Forward DC/DC Converter Using Non-dissipative Snubber (무손실 스너버적용 고주파 소프트 스위칭 Forward 컨버터)

  • 최해영;김은수;변영복;김철수;김윤호
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.614-617
    • /
    • 1999
  • To achieve high efficiency in high power and high frequency applications, reduction of switching losses and noise is very important. In this paper, an improved zero voltage switching forward dc/dc converter is proposed. The proposed converter is constructed by using energy recovery snubbers in parallel with the main switches and output diodes of the conventional forward dc/dc converter. Due to the use of the energy recovery snubbers in the primary and secondary side, the proposed converter achieves zero-voltage-switching turn-off without switching losses for switching devices and output rectification diodes. The complete operating principles and experimental results will be presented.

  • PDF

Soft switching high power factor buck converter using loss less snubber circuit (무손실 스너버 회로를 이용한 소프트 스위칭 강압형 고역률 컨버터)

  • 구헌회;변영복;김성철;서기영;이현우
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.6
    • /
    • pp.77-84
    • /
    • 1997
  • buck type converter doesn't appear when an input voltag eis lower than an output voltage. This is the main reason the buck converter has not been used for high power factor converters. In this paper, soft switching high power factor buck converter is proposed. This converter is composed of diode rectifier, input capacitor can be small enough to filter input current, buck converter with loss less snubber circuit. Converter is operated in discontinous conduction mode, turn on of the switching device is a zero current switching (ZCS) and high powr factor input is obtianed. In addition, zero voltage switching (ZVS) at trun off is achieved and switching loss is reduced using loss less snubber circuit. The capacitor used in the snubber circuit raised output voltage. Therefore, proposed converter has higher output voltage and higher efficiency than conventional buck type converter at same duty factor in discontinous conduction mode operation. High power factro, efficiency, soft switching operation of proposed converter is veified by simulation using Pspice and experimental results.

  • PDF

Soft-Switching Phase-shifted PWM Full-bridge Converter for high power applications (고전력 응용을 위한 소프트 스위칭 위상 천이 PWM 풀 브리지 컨버터)

  • 김영필;김태웅;한완옥;이성백
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.188-192
    • /
    • 2000
  • This paper presents a novel prototype of soft-switching PWM Full-bridge converter which incorporates active power switches in series with each rectifier diode in transformer secondary side. Switching and conduction losses of all the switches and devices are reduced as well as commutating current and circulating current flowing through transformer as compared with conventional converter. And duty ratio of primary switches is constant for maximum voltage conversion ratio. But this converter can be varied output by duty ratio of secondary switches. Operation principles basically the same as that of the PWM Full-bridge converter published previously. The operating characteristics of this converter are illustrate and discussed including the simulated analysis.

  • PDF

A Soft-Switching Technique of Matrix Converters using Auxiliary Switch (보조스위치를 이용한 매트릭스 컨버터(Matrix Converter)의 소프트스위칭 기법)

  • Um, Tae-Wook;Kim, Yoon-Ho;Kim, Seung-Mo
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.519-524
    • /
    • 2002
  • This paper presents a soft-switching technique of single-stage power conversion Matrix Converter of AC-AC converters. Conventional hard-switching method is limited to operate at low switching frequency due to increased switching loss. In this paper, by additional auxiliary switch circuits, it is shown that the main switch of the matrix converter operate as a zero-voltage switches, and the auxiliary switch operate as a zero current switch. Finally, the soft-switching technique with auxiliary switches is compared with conventional hard-switching technique, and Is analyzed by simulation.

  • PDF

Comparison and Analysis of the Soft-Switching ZVT Converters in Efficiency Using PSPICE (PSPICE를 이용한 소프트 스위칭 ZVT컨버터 효율 비교와 분석)

  • Kim Yoon-Ho;Kim Su-Hong;Lee Kang-Hee;Kim Seung-Mo
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.364-369
    • /
    • 2002
  • Presently, a high frequency switching technique is used for a converter design to reduce its size and weight. However an increased switching frequency introduces a high switching loss. To the reduce switching loss, soft switching techniques using ZVS and ZCS are applied. It is very important to improve efficiency. However In general to develop new converter circuits, the efficiency and other performance parameters can be determined after design, implementation and experiments. The idea in this paper is to determine and predict efficiency and other operating characteristics without realization and experiments. Thereby a complex design and implementation can be avoided. PSPICE is used as a simulation tool. This is verified by comparing simulation and experiments results of the two different soft switching converters.

  • PDF

Single Soft-Switching Multi-Level Energy Recovery Circuit Driver for Plasma Display Panel (플라즈마 디스플레이 채널을 위한 단일 소프트-스위칭 다단계 에너지 회수 회로 드라이버)

  • Jacobo Aguillon-Garcia;Moon Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.413-416
    • /
    • 2006
  • The power source of an AC-PDP fur sustainer circuit is operated in high-voltage and high frequency switching during the process required to achieve the gas discharge current to generate light in a PDP panel. Since PDP has the characteristics of a pure capacitive load, the displacement current that occurs during charge and discharge generates considerable reactive power. An auxiliary circuitry called Energy Recovery Circuit (ERC) reduces the capacitive displacement current. However, this auxiliary topology also bears high stress in its components. In this paper, a multilevel voltage wave shaping sustainer circuit with auxiliary ERC characteristics for an AC-PDP driver is proposed. A comparative analysis and experimental results are presented.

  • PDF

An Improved Soft-Switching Inverter with An Unidirectional Auxiliary Switch (단방향 보조 스위치를 갖는 개선된 소프트 스위칭 인버터)

  • Sohn, Se-Jin;Lee, Kui-Jun;Kim, Rae-Young;Hyun, Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.376-377
    • /
    • 2010
  • In this paper, novel unidirectional auxiliary resonant commutated pole is proposed to improve the performance of zero-voltage soft-switching inverter. The proposed circuit keeps the advantages of the original soft-switching inverter, while providing more effective resetting capability in magnetizing current. Based on the advanced reset mechanism, auxiliary switches operate under a complete zero-current condition. The operating principle and steady-state analysis are presented theoretically, according to its operating modes. Accordingly, it proves the fact that the proposed unidirectional auxiliary resonant commutated pole breaks an unwanted magnetizing current loop effectively. The performance of the proposed circuit is verified by several simulation results.

  • PDF

Bidirectional Soft Switching DC-DC Converter using ZVS method (ZVS기법을 사용한 양방향 소프트 스위칭 DC-DC 컨버터)

  • Oh, Soon-Tack;Kim, Jae-Hyung;Eom, Ju-Kyung;Won, Chung-Yuen;Jung, Yong-Chae
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.29-30
    • /
    • 2010
  • This paper proposed bidirectional DC-DC converter applying soft switching technique. Compared with conventional bidirectional converter, the main switches of proposed converter are operated without switching losses, and auxiliary switches were run under soft switching condition using quasi-resonant current mode. To verify the validity of the proposed converter, mode analysis and simulation results are presented.

  • PDF

A Soft Switching Bidirectional DC-DC Converter Using ZCT method (ZCT 방식을 이용한 양방향 소프트 스위칭 DC-DC 컨버터)

  • Lee, Il-Ho;Park, Kun-Wook;Jung, Doo-Yong;Kim, Jae-Hyung;Won, Chung-Yuen;Jung, Yong-Chae
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.479-480
    • /
    • 2010
  • In this paper, the bi-directional soft switching DC-DC converter using ZCT(Zero Current Transition) method is proposed for using battery application system. This topology is composed of soft switching bi-directional buck/boost converter having the ZCT auxiliary circuit with two switches, two resonant capacitors, one resonant inductor. Therefore, the proposed topology can reduce switching loss. To verify the validity of the proposed topology, theoretical analysis and simulation results are presented.

  • PDF

Three Phase Voltage-ed Soft Switching Inverter using Auxiliary Resonant DC Link (보조공진 DC 링크 스너버를 이용한 3상 전압형 소프트 스위칭 인버터)

  • Kim, Ju-Yong;Suh, Ki-Young;Lee, Hyun-Woo;Mun, Sang-Pil;Ryu, Jae-Yup
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.143-146
    • /
    • 2002
  • This paper proposes a new auxiliary resonant DC link(ARDCL)snubber circuit and deals with its power loss on the basis of actually-measured conduction loss characteristic of switching device module. Voltage-ed soft switching three-phase inverter using proposed ARDCL snubber circuit is presented along with its performance evaluations. And, the power loss analysis of three-phase hard and soft switching inverter are carried out from the point of simulation and experimental results.

  • PDF