• Title/Summary/Keyword: 소프트 렌즈

Search Result 124, Processing Time 0.034 seconds

A Study of Ultrastructure on attachment of Soft Contact Lens Surface of Incubated Pseudomonas aeruginosa (배양된 Pseudomonas aeruginosa의 소프트 콘택트 렌즈 표면부착에 대한 미세구조적 연구)

  • Kim, Douk Hoon;Park, Yong Tae;You, Hae Byung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.11-14
    • /
    • 2000
  • The soft contact lens was very simple technique in handling, good sensation in fitting, good effect of a beauty, and good attachment state on the cornea in physical movement. So that, the subjects have used the correct of visual acuity. If the contact lens handling have not skill, they have acquired the side effect on eye. To analysis of a study of ultrastructure on soft contact lens surface of incubated P. aeruginosa. We have observed the soft contact lens surface by SEM. We have founded the good technical method. On the method of sample process of manufacture, the best observation of samlpe tissue was $OsO_4$ postfixation and tannic acid treatment. In this case, P. aeruginosa was a rod shape and one cilia in ultrastructure and the identification was very good. But, On the process of manufacture have not used the $OsO_4$ and tannic acid treatment, this tissue sample appeared the foreign body materials and artifacts, and the identification of the P. aeruginosa was very difficult.

  • PDF

Change of Corneal Shape with Soft Contact Lens Type (소프트콘택트렌즈의 유형에 따른 각막형태의 변화)

  • Woo, Chul-Min;Lee, Hyun Mee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.111-120
    • /
    • 2014
  • Purpose: This study was to investigate changes in the thickness of cornea, curvature of cornea, and aberration depending on the water contents, materials, and refractive power of contact lens. Methods: The differences in the corneal thickness between pre- and post-wearing the lenses were compared using 5 kinds of lenses. The changes in the corneal thickness, the curvatures of the anterior and posterior cornea, and high order aberration (HOA) before and after wearing the lenses were investigated at the center of the cornea, and the different distance and the direction away from the center of the cornea. For the equipments of measurement, ORB ScanII (Bausch & Lomb Inc, ver 3.14) was used to measure the corneal topography and thickness, and Zywave (Bausch & Lomb Inc, ver 5.20) was used to analyze the high order aberration. Results: Five (S1, S2, S3, T1, T2) of the lens was used for this study, excluding the lens T2 lens has four lenses and the thickness of the corneal shape, but the impact is minimal. In the case of the hydrogel soft contact lenses (T2 lens) with low oxygen permeability, the corneal thickness showed distinct increasing patterns. The high order aberration and coma aberration were most changed in the silicon hydrogel toric lens, while the depth of anterior was most changed in the hydrogel toric lens. Conclusion: Among the 5 kinds of contact lenses with different water contents, materials, and refractive power used for this study, the corneal shape change was small for the lenses with an oxygen permeability (Dk) of more than 28, and the largest for the lenses with a very low oxygen permeability.

Bleaching Observation of Cosmetic Color Lenses According to Multipurpose Contact Lens Solutions (다목적 콘택트렌즈 용액에 대한 미용 칼라렌즈의 탈색 관찰)

  • Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.295-303
    • /
    • 2014
  • Purpose: This study aims to observe bleaching resulted from multipurpose contact lens solutions used to manage lenses with the subjects of colored contact lenses being distributed in Korea. Methods: The lenses have been worn for six months, and their refraction is 0.00D. Three types of colored contact lenses of which margin has been colored with a different manufacturing method have been adopted (type 1: pigment application method, type 2: chemical bonding process, type 3: sandwich method), and multipurpose solutions used were two types containing different components. Each of the colored contact lenses was stored in the multipurpose solutions for 20 days and went through vortexing for 15 seconds per day. Their fluorescence absorbance, surface roughness, brightness index, and color coordinate index were measured before and after the vortexing to see the degree of bleaching. Results: In the two types of multipurpose solutions, every type of the color contact lenses showed no statistically significant difference in their fluorescence absorbance value before and after the vortexing. Regarding surface image, the front surface of the lenses was smooth in every type, and about the back surface, type 3 indicated less protrusion than type 1 and 2. About the difference of color on the lens surface before and after the vortexing, type 3 showed significantly less difference than type 1 and 2; however, all fell into the permissible error. Conclusions: About the bleaching of colored contact lenses resulted from multipurpose solutions for soft contact lenses, there was no difference observed in terms of fluorescence absorbance and color. According to the methods of manufacturing dyes, however, there was difference in the protrusion of the posterior surface image.

Polymerization of HEMA by Electron beam Irradiation and Fabrication of Soft contact lens (전자빔조사에 의한 HEMA의 중합과 소프트콘택트렌즈 제조)

  • Hwang, Kwang-Ha;Shin, Joong-Hyeok;Sung, Yu-Jin;Jeong, Keun-Seung;Jun, Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.135-141
    • /
    • 2012
  • Purpose: Polymerization of HEMA(2-hydroxyethyl methacrylate) which can be used in the soft contact lens has been performed by using electron beam(EB) irradiation, and examined the best condition for the polymerization. Comparing the physical properties of the contact lenses to the one fabricated by thermal polymerization method, we check the use possibility of the EB irradiation to the fabrication of the soft contact lens. Methods: We investigated the degree of polymerization of the HEMA according to the composition of the monomer, the additive ratio and the dose of electron beam (0~120 kGy). The degree of polymerization was measured depending on the EB dose to research the best synthetic condition under the EB irradiation. The physical properties of the contact lens such as water content(%), oxygen transmissibility(Dk/t) and optical transmittance were analysed by using the FT-IR results with comparing the two different polymerization method (thermal and electron beam polymerization) with same additive ratio. Results: When the dose of electron beam was above 100 kGy, the degree of polymerization of HEMA was above 99% with regardless using cross-linker and initiator. The water content of the lens fabricated by EB method showed 10% higher than the one by the thermal method which was 40%. The lens fabricated by EB method also showed higher oxygen transmissibility(Dk/t) as same with the water content, and showed twice higher value in the lens fabricated by pure HEMA. According to the FT-IR results, hydrophilic property of the lens fabricated by EB method was increased due to increasing the intermolecular hydrogen bonding. It showed above 90% optical transmittance in the visible range of wavelength on the contact lenses fabricated by the both of two different polymerization method. Conclusions: The polymerization of HEMA without cross-linker and initiator was successful above 100 kGy of EB irradiation. Moreover the lens fabricated from the polymer synthesized by pure HEMA with 100 kGy of EB showed the highest water content and oxygen transmissibility. Therefore EB irradiation is another possible method to synthesize the polymer which can be used for the soft contact lens.

Change of Spherical Aberration with Aspheric Soft Contact Lens Wear (비구면 소프트콘택트렌즈 착용에 의한 눈의 구면수차 변화)

  • Kim, Jeong Mee;Mun, Mi-Young;Kim, Young Chul;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.365-372
    • /
    • 2012
  • Purpose: To investigate ocular higher order aberrations (HOA) and spherical aberration changes caused by an aspheric soft contact lens designed to reduce spherical aberration (SA) of the eye. Methods: Fifty subjects who have successfully experienced soft contact lenses were refitted with aspheric design (Soflens Daily Disposable: SDD, Bausch+Lomb) soft contact lens. Ocular higher order aberrations (HOA) and stand alone SA were measured and analyzed for a 4-mm pupil size using Wave-Scan Wavefront$^{TM}$ aberrometer (VISX, Santa Clara, CA, USA). High and low contrast log MAR visual acuity and contrast sensitivity function (CSF) were also measured under photopic and mesopic conditions (OPTEC 6500 Vision Tester$^{(R)}$). All measurements were conducted monocularly with an undilated pupil. Results: The RMS mean values for total HOA with SDD contact lenses were significantly lower than those at with unaided eyes (p<0.001) and a reduction for SA in the SDD was close to the baseline SA (zero ${\mu}m$) (p<0.001). For the SDD lens, there was a statistically significant correlation between the changes in the total HOA and the contact lens power (r=0.237, p=0.018) as well as between the changes in SA and the lens power (r=0.324, p=0.001). High contrast visual acuity (HCVA) and low contrast visual acuity (LCVA) with SDD lenses were $-0.063{\pm}0.062$ and $0.119{\pm}0.060$, respectively under photopic and $-0.003{\pm}0.063$ and $0.198{\pm}0.067$, respectively under mesopic condition. Contrast Sensitivity Function (CSF) with SDD lenses under both photopic and mesopic conditions was $3.095{\pm}0.068$ and $3.087{\pm}0.074$, respectively. Conclusions: The SDD contact lens designed to control SA reduced the total ocular HOA and SA of the eye, resulting in compensating for positive SA of the eyes. Thus, the optical benefits of the lens with SA control would be adopted for improving the quality of vision.

Study on the Contact Lenses Wear Status of University Students (대학생들의 콘택트렌즈 착용 실태에 관한 연구)

  • Kim, Tae-Hun;Min, Gyeong-Rok;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.151-157
    • /
    • 2005
  • The purpose of this study is to get related appropriate data for correct awareness and education of the university students who are using contact lens by investigating university students' awareness, present status, using habits and complication of contact lens. The method of survey was made by questionnaires which were spread to the group of 408 university students. The result indicated some characteristics including using daily wear soft lens of 55.7%, the major motive of using them is for cosmetics of 45.6%. Among them, 54.9% experienced complication, and the xerophthalmia was the most conspicuous case in the aspect of the kinds of the complication. In the aspect of the place where they purchased the contact lens, 93% of the users bought them at eye glasses stores. But when they experienced inconveniences of the contact lens, only 18.8% consulted the Stores. In the fact, I think, the users don't seem to trust the stores fully. Furthermore, 43.5% endure the inconveniences when they get them without any treatment. The fact indicates that they don't realize the seriousness of the complication due to contact lens. Reviewing above-stated facts, information and education for correct awareness and managing methods of contact lens, the complication seem 10 be required. In addition, optician specialized knowledge on contact lens and the sense of duty on national eye health improvement seem to be required.

  • PDF

Comparison of Contrast Sensitivity Between Soft Contact Lens Wearers and Spectacle Wearers (콘택트렌즈와 안경 착용자의 대비감도 비교)

  • Kim, Jai-Min;Lee, Min-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.119-125
    • /
    • 2007
  • The aim of the present study was to compare the contrast sensitivity of soft contact lens wearers, spectacle wearers or emmetropia. Seventy myopic eyes and thirty emmetropic eyes aged 19 to 26 years were collected. The myopic group included 48 eyes corrected with spectacle lenses and 22 eyes of them corrected with contact lenses, too: all had corrected vision acuity of 20/20 or better. Spatial contrast sensitivity was measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView  Functional Vision Analysis software at photopic or mesoopic condition. There was no significant difference in contrast sensitivity between spectacle lenses and emmetropes. Myopes corrected with soft contact lenses showed statistical sensitivity losses at 1.5, 12 cycle/degree spatial frequencies. In conclusion, our findings suggest that loss of contrast sensitivity in soft contact lens wearers might be interpreted as evidence for corneal disruption before corneal pathological events occur in contact lens wearers. Contrast sensitivity testing appears to be a useful method for evaluating soft contact lenses.

  • PDF

The diameter and base curve changes of soft contact Lens by protein deposition (단백질 침착에 의한 소프트콘택트렌즈의 직경 및 곡률반경 변화)

  • Park, Mi-Jung;Cho, Gyu-Tae;Shin, Sung-Hwan;Lee, Heum-Sook;Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.165-171
    • /
    • 2005
  • The aim of the study was to investigate the diameter and base curve changes of soft contact lens by protein deposition. Soft contact lenses were soaked in artificial tear or protein solution which had the same composition with tear for 2min, 10min, 30min, 1hr, 3hr, 6hr, 12hr, and 24hr. Diameter and base curve changes of soft contact lenses were examined by using the high speed camera(Fastcam ultima 1024). The longer the soaking time of soft contact lenses in the artificial tear, the diameter and base curve changes of soft contact lenses was more increased. In the case of soft contact lenses adsorbed only protein, the similar pattern was shown and the diameter and base curve were decreased. However, the influence of calcium ion was found to be less than that of protein. These results suggest that the tear protein causes the diameter and base curve decrease of soft contact lens, which might be related to the discomfort after soft contact lens wearing.

  • PDF