• Title/Summary/Keyword: 소프트 렌즈

Search Result 124, Processing Time 0.024 seconds

The Effects of Ultrasonic Cleaner for Eye Glasses on Protein Deposits and Parameters in Soft Contact Lens (안경용 초음파세척기에 의한 소프트콘택트렌즈의 단백질 침전물 세척효과)

  • Ju, Eun-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.227-234
    • /
    • 2010
  • Purpose: The cleaning effect of protein deposit and the change of contact lens parameters by ultrasonic cleaner for eye glasses on the soft contact lenses were investigated. Methods: Etafilcon A contact lenses contaminated with protein, was ultrasonicated by ultrasonic cleaner for eye glasses and for the control group, spoiled contact lenses were cleaned by multi-purpose solution. The remaining protein deposits on the contact lenses were determined after extraction and the changes of overall diameter, base curve, center thickness power, and water contents on contact lenses were measured and surfaces of contact lenses were observed by scanning electron microscope. Results: The cleaning efficacies of multi-purpose solution on protein deposited etafilcon A contact lenses were 6.08%, and 23.73~33.92% in the group of ultrasonic cleaner for eye glasses with multi-purpose solution and 0~12.99% in the group of ultrasonic clear for contact lens with multipurpose solution depending on the treatment time. The changes of parameters and surface on contact lenses by ultrasonication were not observed. Conclusions: Ultrasonic cleaner for eye glasses can be used to eliminate protein deposits for the diagnostic soft contact lens in the office since it was effective to eliminate protein deposits and not caused change of parameters on soft contact lenses.

Effects of Base Curve on Fitting with the current Soft Contact Lenses (베이스 커브에 의한 콘택트렌즈 피팅 효과)

  • Choe, Oh Mok;Gang, Myoung Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.65-72
    • /
    • 2000
  • The study investigated the effects of base curve radius art the fit of thin, mid-water contact lenses. It was found that central corneal curvature(as measured with the keratometer) was not predictive of the best fitting base curve. Proper lens fit may be the single most important factor that ultimately determines the success of contact lens wear. Comfort, vision, and physiological response are all dependent on the fit of the lens. The percent of optimal fits was highest with the 8.4 mm base curve lens for all three ranges of keratometry values. When fit with the 8.4 mm lens. For most eyes, fitting a flatter lens led to greater decentration, decreased comfort, and no increase in lens movement. The 8.4 mm lens was found to provide on "optimal" fit in over 60% of eyes tested and a fit of "good" or "better" in nearly 90% of eyes tested. Comparisons of different manufactures' lens found that similiar lenses do not always fit in the same way due to subtle design and production differences. Therefore, different products may require different base curve radii to fit the same patient. This is even true when water content, center thickness, and diameter are approximately the same. A praditioner fitting a new patient in this lenses should begin with the 8.4 mm base curve radius.

  • PDF

The Contamination Level of Lens Cases by Various Wearing and Storage Periods of Soft Contact Lens and the Actual Condition of Lens Cases Care (소프트 콘택트렌즈 착용 기간과 보관 기간에 따른 보관 용기의 오염도 및 보관 용기 관리 실태)

  • Kim, So Ra;Shin, Sang Mok;Park, Jong Ae;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.135-145
    • /
    • 2011
  • Purpose: This study was conducted to investigate the actual condition of caring soft contact lens cases and the change in contamination level of lens cases by wearing and storage period of soft contact lens. Methods: The actual condition of caring soft lens cases was surveyed with sixty-three of contact lens wearers. Soft contact lenses were worn for 1, 3, 7 and 14 days, and the lenses were separately stored in 12 lens cases for 1, 3 and 7 days. The contamination level of lens cases was determined by counting the numbers of microorganisms, gram negative bacteria and fungi. Results: Only 14% of survey answerers cleaned their lens cases with a brush, rinsed and dried them upside down before next usage of lens case when those lenses were kept for a long time. Furthermore, 54% of total answerers just kept soft contact lens in the case without changing the multipurpose solution. Microorganisms, gram negative bacteria and fungi were detected in lens cases even when soft contact lens were kept for 1 day in the lens case after wearing for 1 day and cleaning it with multipurpose solution. The numbers of microorganisms, gram negative bacteria and fungi in lens cases increased with storage periods of soft contact lens, and also contamination level of lens cases was increased in accordance with wearing period of lens. In the lens cases without changing multipurpose solution, the numbers of microorganisms, gram negative bacteria and fungi increased with storage period of lens with statistical significance. Conclusions: This study showed that lens wearers' concerns on caring contact lens case were not satisfactory. As the result, the contamination of lens cases was related to increase of lens wearing and storage periods suggesting that the proper instruction and education for lens wearers are required.

Reliability of Measurements of Back Vertex Power for Soft Contact Lenses Using an Auto-Lensmeter (자동렌즈미터를 이용한 소프트 콘택트렌즈의 굴절력 측정 방법에 관한 신뢰도)

  • Kim, Kun-Kyu;Lee, Wook-Jin;Lee, Sun-Haeng;Kwak, Ho-Won;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.39-46
    • /
    • 2010
  • Purpose: To assess the reliability for measuring the back vertex power of soft contact lenses by dry blotting and wet cell method using an auto-lensmeter. Methods: The soft contact lenses used for measurement were 5 types that were distributed in Korea, and 4 back vertex powers (-1.50D, -3.00D, -6.00D, -9.00D) were used. and repeatability and reproducibility were evaluated by measuring them with an auto-lensmeter by two examiners. Results: Measured powers by dry blotting method were ranged in mean differences from 0.03D to 0.18D for overall lenses, 0.10D to 0.18D for silicone hydrogel lenses, 0.03D to 0.08D for hydrogel lenses. The mean differences between two examiners were less than 0.10D, and the inter-examiner reproducibility was good for dry blotting method. The mean difference between powers determined by wet cell method were 0.09D to 0.69D, the mean differences between two examiners were 0.02D to 0.59D. The reliability of measurements and inter-examiner reproducibility were less than dry blotting method. Conclusions: The reliability of measurements for all materials was better in dry blotting than wet cell method, the re liability of measurements for silicone hydrogel lenses was low in both methods. In clinical practical which requires quick checking of back vertex power using an auto-lensmeter. dry blotting method is thought to be more efficient than wet cell one.

Elution Properties of Naringin from Soft Contact Lens Containing Naringin (나린진(naringin)이 함유된 소프트 콘택트렌즈에서 나린진의 용출 특성)

  • Ryu, Geun-Chang;Jun, Jin;Jin, Moon-Seok;Chae, Soo-Chul;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.45-50
    • /
    • 2008
  • Purpose: A soft contact lens was manufactured by adding naringin known as natural anti-bacterial material to resin solution. With solution eluted from manufactured contact lens, we examined its optical properties, physical and chemical states of naringin in the polymer, and elution properties. Methods: The soft contact lens with naringin was synthesized by bulk polymerization method. IR spectrum and HPLC were used to define the bonding type of naringin itself in the soft contact lens contained naringin, elution process of naringin to the saline solution, and the amount of naringin solution eluted from the lens with elapsed time. Results: Naringin was continuously eluted with constant concentration from the soft contact lens for about a month and the structure ofnaringin which is eluted was as same as before it was added to resin solution. Any change in optical properties such as transmittance couldn't be found. Bonding state and the structure of naringin in contact lens were explained with IR spectrum and HPLC results. Conclusions: In the contact lens with naringin, naringin remained in the contact lens bonding with weak hydrogen bonding and/or van der Waals force between naringin and polymer. Naringin was continuously eluted from the contact lens contained naringin during about 1 month. Even after 1 month, it showed that the concentration of the naringin eluted was approximately 10 ppm in a day. From the results, adding naringin to the soft contact lens resin is very effective method for manufacturing the soft contact lens which has anti-bacterial function for a period of time.

  • PDF

The Comparison of Lens Movement by the Fitting States of Soft Contact Lenses in Normal and Dry Eyes (정상안과 건성안에서 피팅상태에 따른 각막에서의 소프트렌즈 움직임 비교)

  • Jung, Da I;Lim, Shin Kyu;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.21-30
    • /
    • 2011
  • Purpose: The study was performed to compare the differences in lens rotation, lens movement by blinking and lens centration with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified into the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment fitting or steep fitting. Lens rotation, lens movement by blinking and lens centration were separately measured immediately after lens wearing and after stabilization of tear film and compared by fitting states of soft contact lenses. Results: With steep fitting of soft contact lens in dry eyes, averaged lens rotation immediately after lens wearing was not significantly different from that of the normal eye group with alignment fitting however, lens rotation after stabilization in dry eyes was significantly larger than that in normal eyes. Any significant difference in lens movement by blinking was not shown in normal eyes. However, lens movement by blinking in dry eyes was increased with steep fitting. The range of lens centration on cornea in normal eyes with alignment fitting was more vertically distributed. On the other hand, the range of lens centration on cornea in dry eyes with alignment fitting was more horizontally distributed. Lens centration was shown to be changed by stabilization of tear film. That is, lens centrations were somewhat vertically widespread immediately after lens wearing and restrictively distributed in horizontal direction, respectively, with steep fitting in dry eyes. Conclusions: These results suggested that lens movements and centration in dry eyes were different from those of normal eyes. Especially, those differences between normal and dry eyes were much bigger with steep fitting of soft contact lenses. Thus, those differences should be considered for the comfortable and safe fitting of soft contact lens in dry eyes.

Relationship between the Deposition of Tear Constituents on Soft Contact Lenses according to Material and Pigmentation and Adherence of Staphylococcus aureus (소프트콘택트렌즈 재질과 착색에 따른 눈물성분 침착과 포도상구균 흡착의 상관관계)

  • Park, So Hyun;Park, Ill-suk;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.109-117
    • /
    • 2016
  • Purpose: The study was aimed to figure out the effect of materials and pigmentation of soft contact lens on the adherence of Staphylococcus aureus upon soft contact lenses deposited with tear components. Methods: The number of adherent S. aureus on clear and circle soft contact lenses made of etafilcon A, hilafilcon B, nelfilcon A was measured before and after incubation in artificial tear. Furthermore, the denaturalization level of tear protein with time after incubation in artificial tear was estimated by electrophoresis. Results: The adherence of S. aureus was significantly different according to the lens materials. The pattern of bacterial adherence on clear and circle contact lenses was different. That is, the adherent amount of S. aureus was somewhat larger on circle lens made of etafilcon A however, amount on circle lenses made of hilafilcon B and nelfilcon A was 89.3% and 71.3% of the number on clear lenses. When the tear protein was deposited on contact lenses, the number of adherent bacteria decreased and its degree was varied according to the lens material. The degree of decrease was the biggest in clear soft lens made of etafilcon A. Anti-bacterial effect of tear protein decreased with time after deposition of tear protein on soft contact lens and the amount of lysozyme also decreased. The reduction of anti-bacterial effect and quantity of lysozyme was different according to contact lens materials and pigmentation. Conclusions: It was revealed that the adherence of S. aureus depends on contact lens materials and pigmentation, and the specification of lens material affects more on adherence of S.aureus than pigmentation. It was further figured out the denaturalization level of anti-bacterial protein on soft contact lens varies according to lens materials and pigmentation, which produces an effect on the quantity of bacterial adherence.

Controlling Physics-Based Fluid and Rope Animations Using Microsoft HoloLens (마이크로소프트 홀로렌즈를 이용한 물리 기반 유체와 로프 애니메이션 제어)

  • Kim, Min Ji;Kim, Jong-Hyun
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2022.07a
    • /
    • pp.577-580
    • /
    • 2022
  • 본 논문에서는 마이크로소프트(Microsoft, MS) 홀로렌즈v2를 이용하여 물리 기반 애니메이션은 유체와 로프를 제어할 수 있는 새로운 방법에 대해 소개한다. 물리 기반 시뮬레이션 혼합현실, 메타버스, 게임 등 다양한 콘텐츠에서 몰입감을 개선하기 위해 활용되고 있는 기술이다. 하지만, 계산양이 크고 사용자가로 인한 직관적인 제어 시스템의 부재로 많은 시장에 활용되기에는 어려운 구조이다. 이러한 문제를 완화하기 위해 본 논문에서는 혼합현실 환경에서 무선으로 사용자 인터페이스를 구현한 홀로렌즈v2를 이용하여 물리 애니메이션을 제어하고자 한다. 이러한 도전은 혼합현실에서도 사용자의 손동작, 음성, 눈 추적 등 다양한 인터페이스를 통해 시뮬레이션을 제어할 수 있다는 가능성을 열어줌으로써, 관련시장도 확장 될 수 있다. 본 논문에서는 대표적으로 유체와 로프 시뮬레이션을 홀로렌즈를 통해 제어하는 결과를 보여준다.

  • PDF

The Effects of Corneal Eccentricity and Shape on Toric Soft Lens Rotation by Change of Postures (이심률 및 각막형상이 자세변화에 의한 토릭소프트렌즈의 회전에 미치는 영향)

  • Kim, So Ra;Hahn, Shin Woong;Song, Ji Soo;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.449-456
    • /
    • 2013
  • Purpose: The present study aimed to investigate the effects of corneal eccentricity and shape on the rotational pattern of toric soft lens by the postural change of lens wearers. Methods: The corneal eccentricity of 41 eyes (aged 20s) having -1.0 D with-the-rule corneal astigmatism (WRCA) was measured, and then toric soft lenses were fitted with the amount of total astigmatism. In lying and straight postures, the rotation of toric soft lenses was recorded by a camera attached to slitlamp and analyzed. Results: Most toric soft lens designed with accelerated stabilization rotated to the temporal direction, which was the lying position direction, regardless of corneal eccentricity, and some lenses rotated to the nasal direction for high corneal eccentricity and corneal type of asymmetric bowtie. There was no correlation between the amount of rotation and corneal eccentricity right after of contact lens wearing in straight and lying posture, however, the amount of rotation was the greater for the cornea with the higher eccentricity after the subjects laying down for some period. The speed of lens rotation started to decrease after the subjects laying down, but the speed was not different according to corneal eccentricity difference. The amount of lens rotation for symmetric and asymmetric bowtie-typed corneas increased more than it for oval-typed cornea, and it was same even with time elapsing. The speed of lens rotation in lying posture was the slowest in asymmetric bowtie-typed cornea compared with other corneal types. Conclusions: From the present study, it was revealed that the rotational pattern of toric soft lens was affected by corneal eccentricity and corneal shape when the wearer's posture changed. Thus, it should be considered for the development of the fitting guideline and the design of toric soft lens.

The Change in Refractive Powers of Soft Contact Lenses Caused by the Deposition of Tear Proteins (누액 단백질 침착에 의한 소프트콘택트렌즈의 굴절력 변화)

  • Choi, Jin-Yong;Park, Jae-Sung;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.383-390
    • /
    • 2011
  • Purpose: The present study was conducted to investigate whether refractive powers of soft contact lenses were induced by the deposition of tear proteins when wearing soft contact lenses. Methods: The soft contact lenses (material: etafilcon A, hilafilcon A and comfilcon A) with refractive powers of -1.00 D, -3.00 D, -5.00 D and -7.00 D were incubated in artificial tear for 1 day, 3 days, 5 days, 7 days and 14 days, respectively. After incubation, their refractive powers were measured by wet cell method with an auto-lens meter and their protein deposited on the lenses was determined by the method of Lowry. Results: Among three types of soft contact lenses, the most protein deposition was detected in ionic etafilcon A lens material and significant change of its refractive power was manifested. In other words, refractive powers of etafilcon A lenses firstly decreased after 1 day incubation in artificial tear and then gradually increased with increasing incubation period again. The observed change in refractive powers of all diopters of etafilcon A material was beyond the scope of standard error and bigger in the lens with lower optical power. On the other hand, non-ionic hilafilcon A showed less protein deposition as much as about 20% in etafilacon A and statistically significant increase of refractive powers with increasing incubation period in artificial tear. The change in refractive power of hilafilcon A was also beyond the scope of the standard of error when incubating in artificial tear and greater in the lens with lower diopter. The least protein deposit was shown in silicone hydrogel lens material, comfilcon A as approximately 10% of it in etafilcon A, indicating less change in refractive power within the standard range of error. Conclusions: The large change of refractive powers that was beyond the scope of standard error by the deposition of tear proteins on soft contact lenses was differently detected depending on lens materials in the current study. Thus, the deposition of tear proteins induced by longer period of lens wearing may be one of the causes that induces blurred vision, suggesting that soft contact lens wearers with the amount of tear proteins may need to choose proper lens material.