• Title/Summary/Keyword: 소프트 렌즈

Search Result 124, Processing Time 0.027 seconds

Contrast Sensitivity and Glare with Spherical and Toric Soft Contact Lenses in Low-astigmatic Eyes (구면과 토릭 소프트 렌즈로 교정한 약도 난시안의 대비감도와 눈부심)

  • Lee, Min-Ah;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Purpose: The purpose of this study is to compare the visual performance by contrast sensitivity (CS) and disability glare (DG) in low astigmatic eyes corrected with toric soft lenses and other optical corrections. Methods: Twenty university students with myopia (-1.00 to -6.50D Sph. with astigmatism up to 1.50 cyl) were enrolled and corrected by five different methods: 1) soft toric lenses; 2) spherical soft contact lenses; 3) RGP lenses; 4) best spectacle corrected visual acuity; 5) spherical equivalent spectacles. All subjects had corrected vision acuity of 20/20 or better. Contrast sensitivity and disability glare were measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView Functional Vision Analysis software at photopic or mesopic conditions with glare. Results: At photopic condition, best corrected spectacle wearers had the highest monocular contrast sensitivity at all spatial frequency followed by soft toric lenses, RGP lenses, spherical equivalent spectacles, and spherical soft contact lenses. However, all of them were in normal contrast sensitivity value at photopic condition. At mesopic condition with glare, toric soft lenses were the highest and followed by RGP lenses, spherical equivalent spectacles, best spectacle corrected visual acuity and spherical soft contact lenses. It was observed that spherical soft contact lens wearers demonstrated lower range than normal contrast sensitivity value at mesopic condition with glare. Conclusion: Toric soft lenses gave better visual performance than spherical soft lenses in low astigmatic eyes. Subjects requiring the use of contact lenses under mesophic conditions could benefit from toric soft lenses.

  • PDF

A Comparison of the Movements of Circle Contact Lens and Soft Contact Lens with Identical Material on Cornea (써클 콘택트렌즈와 동일 재질 소프트 콘택트렌즈의 각막에서의 움직임 비교)

  • Kim, So Ra;Park, Sang Hee;Joo, Seon-Ok;Lee, Hye Rim;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.27-35
    • /
    • 2012
  • Purpose: The present study was conducted to compare any difference caused by pigmentation in the centrations and movement patterns on the cornea between circle and soft contact lens with identical material and parameters during lens wearing. Methods: Soft and circle contact lenses with identical material and parameters were applied to twenty eyes with normal tear volume for 3 hrs a day during a total of 5 days and then their lens centrations, the moving distances and rotations by repeat blinking were compared. Results: The lens centration beyond the fitting criteria was shown in initial wears of both soft contact lens and circle contact lens. However, the centration of soft contact lens was changed to the pupil center for being suitable to the fitting criteria with longer wearing time. On the other hand, the decentration of circle contact lens in the horizontal direction was still presented even with longer wearing time. The moving distances of soft contact lens and circle contact lens decreased with the expand of lens wearing but were not significantly different between total wearing period and daily wearing time. The rotation of circle contact lens by repeat blinking was significantly different from that of soft contact lens even when the wearing period was extended. Conclusions: We revealed that the lens centration and movement of circle contact lens on cornea were different from those of regular soft contact lens resulting in bigger difference with the expand of wearing period in the study.

The Investigation on Ultrasonic Cleaning of Soft Contact Lenses in Local Optical Shops and the Protein Removal Effect by Lens Containers (안경용 초음파세척기를 이용한 소프트렌즈 세척 실태 조사와 세척용기에 따른 단백질 제거 효과)

  • Koo, Sung Bong;Cho, Seul Bee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.31-40
    • /
    • 2011
  • Purpose: This study was performed to investigate the actual state about ultrasonic cleaning of soft contact lenses in local optical shops and evaluate the removal effect of protein deposit on soft contact lenses with different lens containers by ultrasonic cleaner for eyeglasses. Methods: The actual state about ultrasonic cleaning of soft contact lenses was surveyed in total 75 local optical shops in Seoul, Korea. The cleaning efficacy of different lens containers was compared by measuring the protein remained on ocufilcon D contact lenses after washing by an ultrasonic cleaner for eyeglasses. The changes on surfaces and wetting angles of ocufilcon D contact lenses by repeat ultrasonication were further investigated. Results: The main purpose to use ultrasonic cleaners in local optical shops was rapid cleaning. The ultrasonic cleaning efficacy of ocufilcon D contact lenses with glass containers was little higher than it with plastic containers, but was not significantly different. The changes on surfaces and wetting angles of ocufilcon D contact lenses in a plastic lens container by repeat ultrasonication such as 30 and/or 60 times were shown. Conclusions: There was not significant difference in cleaning efficacy between glass and plastic lens containers. However, repeat cleaning with ultrasonic cleaner for eyeglasses would be carefully considered since some significant changes in the parameters of lens surface and wetting angles were detected by repeat ultrasonification even when lens containers were used for ocufilcon D contact lens during ultrasonictions.

Near Visual Performance of Multifocal Contact Lenses in University Students (대학생에서 멀티포컬 소프트콘택트렌즈의 근거리 시기능 유용성)

  • Jong, Woo-Cheol;Kim, Soo-Hyun;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.51-60
    • /
    • 2011
  • Purpose: This study was to investigate visual performance and subjective satisfaction with multifocal soft contact lenses at near works in university students. Methods: In a cross-over study design, 26 students (6 male, 20 female) who did not have any ocular disorder with at least 20/20(1.0) binocular vision were fitted with singlevision lenses (SofLens$^{TM}59$, Bausch + Lomb Co. USA) or multifocal lenses (SofLens Multifocal, Bausch + Lomb Co. USA). After 2 weeks, visual performance assessments included visual acuity, stereoacuity and contrast sensitivity function at distance and near. Near point of accommodation, accommodative facility, near point of convergence, vergence facility and near range of clear vision at near were examined. Students' satisfaction and preference were measured using survey questionaries. Results: Subjects maintained at least 20/20 binocular vision with multifocal and single-vision lenses at distance and near. There was no difference between multifocal and single-vision lenses in stereoacuity, contrast sensitivity function and vergence facility at far and near. The near point of accommodation, accommodative facility, near point of convergence and the near range of clear vision with multifocal lenses were better than single-vision lenses. On the survey questionaries, subjects reported that they preferred and satisfied with multifocal lenses with near works, and single-vision lenses with distance works. Conclusions: The majority of university students preferred multifocal to single vision lenses because multifocal lenses provided better visual performance at near works. This study suggests that multifocal lens is helpful for young adult in prolonged near works.

The State and Problem of the Soft Contact Lens Wearer (소프트 콘택트렌즈 착용자의 실태와 문제점)

  • Kim, Douk-Hoon;Hwang, Sun-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.249-258
    • /
    • 1998
  • This study was researched the state and problem of the soft contact Lens wear by the history and inverted microscopy. The results was as follows; 1. The first use of contact lens wear was the 15 years and the last use was the 26 years. The first age of most contact lens wear was the 19 years. 2. In the almost contact lens wearers, the first visual test was the optical shop. 3. At present, almost soft contact lens purchase the optical shop 4. At present, most contact lens wearer like a soft type. 5. At present, most soft contact lens were a domestic production, and some subjects were foreign country production, but some subjects were unknown. 6. After contact lens wear, most subjects don't known the corrected visual acuity, especially, almost people don't known the binocular visual acuity. 7. At present, on soft contact lens color, the teens like the non-color contact lens, twenties like the color contact lens, but thirties was not known. 8. On the advantage of soft contact lens knowledge, most teens and twenties were only one, thirties was unknown. 9. On the disadvantage of soft contact lens knowledge, most teens and thirties were only one, twenties were two. 10. On the side effect of soft contact lens wearer, teens was one, and twenties and thirties don't known. 11. On the main symptoms of soft contact lens wearer, total kinds were seven, On these kinds, most subjects were not symptoms, the next order was unknown on the symptom. But, On the symptoms, the main symptoms was the pain and dry eye. 12. At present, the research on the surface morphology of soft contact lens by inverted microscope, the lens repture, lens folding, foreign body immersion and etc were present. Above the study, most contact lens was soft lens, and the purchase was the optical shop, on the other hand, the knowledge of soft contact lens and visual acuity was few. As a results, On the practical problems of soft contact lens wear, the optician have to the soft contact lens treatment and aftercare by law and educational supporting.

  • PDF

Comparisons of the Change in Soft Contact Lenses Parameters and the Cleaning Efficiency after Eyeliner Deposition (아이라이너 침착에 의한 소프트 콘택트렌즈 파라미터의 변화 및 세척효과의 비교)

  • Park, Mijung;Kim, Sa Hyun;Ku, Bo Kyoung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.107-115
    • /
    • 2013
  • Purpose: This study was conducted to investigate the change of soft contact lens parameters after eyeliner deposition and compare the cleaning efficiency and the recovery rate of lens parameters by different cleaning methods. Methods: The eyeliner was deposited on three types of soft contact lenses made of different materials for 1 hour, 4 hours and 6 hours and those lenses were washed by the eyeglasses ultrasonic cleaning and by hands. The changes in visible light transmittance, diameter and surface of those lenses were compared before and after cleaning of the lens. Results: The visible light transmittance of soft contact lenses decreased along with the deposition time of eyeliner. The patterns of the eyeliner deposition on soft contact lens appeared differently depending on the physical properties of the lens material. Thus, the largest eyeliner deposition was found on narafilcon A lens. The diameters of hilafilcon B and etafilcon A lenses were decreased, however, the diameter of narafilcon A lens was increased. The cleaning efficiency of the eyeliner deposition was greater with the multipurpose solution by hands than with the eyeglasses ultrasonic cleaner. However, the recovery of lens parameters such as the lens diameter, visible light transmittance and lens surface due to the eyeliner deposition to its original state was limited. Conclusions: From these results, it is suggested to minimize eye makeup when wearing soft contact lens. Furthermore, the reduced wearing time and shorter cycle of lens replacement may be needed by considering a change of lens parameter when the repeat eye makeup is applied.

Microbe Pollution Condition on Soft Contact Lenses (소프트 콘택트렌즈에서의 미생물 오염양상)

  • Han, Sun-Hee;Park, Sung-Min;Yu, Tae-Shick
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.313-321
    • /
    • 2005
  • To know the pollution level concerning the microbes contamination condition in soft contact lenses, 2 experiments were operated with different methods. Firs experiment, we observed lenses surfaces through a scanning electronic microscope after pollution sort contact lenses with the suspensions of Staphylococcus aureus, Pseudomonas aeruginosa and Entrobacter aerogenes which can be major bacteria causing keratitis as wearing on soft contact lenses. As 1 hour after pollution with the soft contact lenses, we observed that many bacteria adhered to the lenses, and the pollution condition got worse with passing time increase(2, 4, 6, 12, and 24 hours, respectively). At 12 hours lapse of polluting soft contact lenses with P. aeruginosa, some bacteria adhered to the lenses. And as 24 hours lapsed after pollution soft lenses with E. aerogenes, bacteria adhered to them, and atypical substance was observed some of the surface of lenses. Second experiment, we observed the microbe pollution condition in soft contact lenses by let 21 people in twenties(men & women), who doesn't eye disorders, wear soft contact lenses during 4 hours. As the result, many kinds of bacterium and fungus were observed, and especially, the bacteria could be identified with their colors and the shapes of colony, so we found that single type, two types, and three types of bacteria adhered to their lenses.

  • PDF

Evaluation of Transmittance Characteristics of Contact Lenses (콘택트렌즈의 광투과율 특성 평가)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Kim, Do-Hyung;Paik, Sun-Mok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.37-45
    • /
    • 2007
  • We have measured the spectral transmittances of UV blocking soft contact lenses, regular soft contact lenses and regular RGP lenses using the method suggested in ANSI Z80.20 standard. In order to evaluate visible light transmitting and UV blocking characteristics, we have calculated transmittances by integrating over the specific spectral ranges, i.e., visible light, UVA, UVB and UVC. We found that mean transmittances of visible light for all three categories were over 90.0 % which could be considered as within acceptable range for a contact lens. The transmittance of the UVA and UVB radiation for the UV blocking soft lenses except some cases was within UVR (Ultraviolet radiation) transmittance standard. The UV blocking ability of regular soft and RGP lenses was poor as rather expected. These results will be expected to assist clinical opticians and practitioners in utilizing the transmittance characteristics about the contact lens.

  • PDF

The Comparative Analysis for the Progression of Dry Eyes Caused by Wearing Soft Contact Lenses(SCL) and Cosmetic Soft Contact Lenses(C-SCL) (소프트 콘택트렌즈와 미용 콘택트렌즈의 건성안 진행에 대한 비교분석)

  • Kim, Myoung-Jin;Hwang, Hye-Kyung;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.375-381
    • /
    • 2011
  • Purpose: The purpose of this research was to see how wearing either a SCL or a C-SCL effected the dryness of a person's eye depending on how long they wear either type of lens. Methods: This study was carried out on 52 subjects (104 eyes) who were all in their twenties and had previously experienced wearing contact lenses. All of these subjects were required to wear either a SCL or a C-SCL, which were made out of the same material, for three months. Contents such as the McMonnies Questionnaire survey, the blinking rate per min. and the Noninvasive tear break-up time test (NIBUT) were later conducted on the subjects for this study. Results: According to the results of the McMonnies Questionnaire, it was concluded that the longer the subject wore the SCL and C-SCL, the value of the measurements gradually increased. On the other hand, the results from the NIBUT concluded that the longer the subject wore the SCL, the value of the measurements eventually decreased. However, according to the measurements of the blink rate test, it was concluded that neither results had a significant change. Conclusions: It was concluded that long-term wearing of SCL and C-SCL could be the cause of the induction and progression of dry eyes.

A Study of Soft Contact Lens Wearer on Women College Students (여대생의 소프트 콘택트렌즈 착용자에 대한 연구)

  • Kim, Douk-Hoon;Yoo, Jae-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.187-192
    • /
    • 2000
  • The objective of this study was to investigate the problems of soft contact lens wear on the women college students. The results were as follows 1. Almost the purchase of soft contact lens was the optical shop. 2. Almost the motive of soft contact lens use was the discomfort of glasses wear. 3. Almost the good feeling of glasses wear was moderate degree. 4. On the main reason of exchange of contact lens, teens was contact lens damage and tweenths was lifespan of contact lens. 5. On the contact lens wearing time at one day, teens was over 10 hours and tweenths was from 7 hours to 10 hours. 6. On the contact care and treatment, teens was a lens washing and storage and tweenths was a lens washing and disinfectant. 7. On the main difficult of contact lens handling, teens was a lens separation in eye and disinfection of lens case and tweenths was a solution treatment and insertion of contact lens in the eye. 8. On the contact lens insertion in the eye, the most difficult item was hanging of the eyelid and fear thinking in teens and fear thinking in tweenths. 9. On the difficult in separate of contact lens wear, a most subjects were eye opening. 10. On the most inconvenient state in contact lens wearing, the subjects were eye redness, foreign body and eye pain. 11. On the advantage of contact lens wearing, teens was decrease in glasses side effects and twenties was a beauty.

  • PDF