• Title/Summary/Keyword: 소음 방사

Search Result 496, Processing Time 0.033 seconds

Study on noise prediction of non-cavitating underwater propeller with hull-appendages effect (선체-부가물 영향을 고려한 비공동 수중추진기의 소음예측 연구)

  • Choi, Jihun;Seol, Hanshin;Park, Ilryong;Lee, Soogab
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.3
    • /
    • pp.247-255
    • /
    • 2019
  • In this study, to predict the noise of a submarine propeller which is going to become bigger and faster, the non - cavitating propeller noise was predicted based on the numerical analysis which considering the interaction of the hull - appendages - propeller. In order to predict the radiated noise of the propeller, the flow field for the entire region of hull-appendages-propeller was computed by CFD (Computational Fluid Dynamics). And the noise for the thickness noise and the load noise was numerically predicted using FW-H (Ffwocs Williams-Hawkings) acoustic analogy. Numerical noise prediction results were verified by model tests and showed good agreement with the measurement results in predicting total noise level and low frequency noise.

Analysis of Aerodynamic Noise Generation Characteristics Using Pantograph Panhead 3-D Simple Model (판토그라프 팬헤드 3 차원 단순모델에 대한 공력소음 발생 특성 분석)

  • Yi, Suk-Keun;Park, Jun-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.308-308
    • /
    • 2010
  • 본 논문에서는 판토그라프의 공력소음 발생 특성을 규명하기 위하여 단순 모델을 이용하여 그 특성을 분석하였다. 단순 모델은 실제 팬헤드의 사이즈를 고려하여 선정하였고, 이를 통해 음압 해석 알고리즘을 구축하고 소음 발생 메커니즘을 분석하였다. 단순 모델을 선정하여 이를 Lattice Boltzmann Method 를 기반으로 한 전산 유체 해석을 통한 결과를 이용하여 음압 레벨과 음압의 방사형태를 계산하고, 풍동 실험을 통해 이를 검증한다. 풍동 실험에서는 단순 모델을 제작하여 100 km/h 의 속도 환경에서 항력, 양력과 소음을 측정하였다. 단면의 형상에 따른 변화 추이를 검토하였으며 해석결과를 단일 수치로도 정량화하여 제시한다. 최종적으로 정립된 알고리즘을 기반으로 팬헤드의 3 차원 모델을 시뮬레이션 한 결과를 제시한다.

  • PDF

능동소음제어-제어음장의 물리적 성질 및 제어방법론

  • 김양한;강성우
    • Journal of KSNVE
    • /
    • v.5 no.4
    • /
    • pp.440-452
    • /
    • 1995
  • 이 글에서는 능동소음제어에 있어서, 음장 혹은 음원을 표현하는 물리량은 음향에너지, 파워, 인텐시티를 통하여 제어 가격함수로서의 각 의미를 살펴보았다. 졍리하면 이 세가지 물량들은 음향에너지의 균형이라는 물리적 변칙에 의해 서로 단단히 결속되어 있으며, 이들은 음장의 형태와 성격 그리고 파장과 주파수 등과 관련이 있으므로, 능동소음제어 입장에서 제어 목적에 맞게 적절히 사용할 필요가 있다고 볼 수 있다. 음향 에너지의 제어 개념 즉, 음향에너지를 가격함수로 하는 제어 방법은, 원하는 정숙공간(zone of quiet)을 제어할 때 그 적절성이 있음을 보았 으며, 음향 파워는 그 물리량 자체가 어떤 음원의 특성을 표현하고 있으므로 제어에 의하여 방사 효율을 감소(weak radiator)시키고자 할 때 가장 자연스러운 가격 함수 가 됨을 살펴보았다. 또한 음향 인텐시티라는 물리량은 음향 에너지의 전달 특성을 대표하는 특성임을 살펴보았고, 따라서 소음 전파의 감소(noise transmission reduction)를 위한 제어 가격 함수로의 당위성을 확인하였다. 이러한 모든 제어 방법 들이 사실은 가관측성 및 가제어성을 가져야 함은 주지의 사실이며, 음향 파워나 인텐시티를 가격 함수로 하는 제어 방법의 경우 실제적인 가관측성상의 문제점들로 인하여 그 현실성이 아직은 거리가 있다 하겠다.

  • PDF

Cabin Noise Reduction using Unit Cabin Mock-up of High Value Ship (고부가가치선의 Unit Cabin Mock-up 을 이용한 캐빈소음 저감 연구)

  • Joo, Won-Ho;Song, Keun-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.483-484
    • /
    • 2010
  • Unit cabin means room, which is installed in the high value ship such as drill ship and FPSO, after pre-assembled. In order to develop the noise control design for a unit cabin, a variety of acoustic tests such as sound absorption, transmission, and radiated noise measurements were carried out by using the mock-up of living quarter. From the tests, it was found out that the combined noise level of a unit cabin could be dominated by the radiated noise from wall panel in low frequency range and the design guidelines for the noise control of unit cabin were fully established, such as the improvement of sound transmission loss between the cabin and corridor, and radiated cabin noise reduction.

  • PDF

The Determination of Transducer Locations for Active Structural Acoustic Control of the Radiated Sound from Vibrating Plate (평판에서 방사되는 소음의 능동구조소음제어를 위한 변환기의 위치결정)

  • 김흥섭;홍진석;이충휘;오재응
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.9
    • /
    • pp.694-701
    • /
    • 2002
  • In this paper, through the study on locations of structural transducers for active control of the radiated sound from the vibrating plate, the active structural acoustic control (ASAC) system is proposed. And, for the evaluation of the proposed location, the experiment of the active structural acoustic control is implemented using the multi-channel filtered-x LMS algorithm and an additional filter (Acoustic Prediction Filter) to estimate the radiated sound using the acceleration signals of the plate. The structural transducers are piezoceramic actuator (PZT) and accelerometer. PZT is used as an actuator to reduce the vibration and the radiated sound. To maximize the control performance, each PZT actuator is located at the position that has the largest control sensitivity of the plate bending moment in the direction of x and y coordinates and the optimal PZT location is validated experimentally. Also, to find the acoustic prediction filter accurately, two accelerometers are located at the positions that have the largest radiation efficiencies of the plate, and the proposed locations are validated by simulation using the Rayleigh integral. The multi-channel filtered-x LMS algorithm is introduced to control a complex 2-D structural vibration mode. Finding the locations of structural transducers for active structural acoustic control of the radiated sound, the active structural acoustic control (ASAC) system can be presented and validated by experiments using a real time control system.

Development of numerical method to predict broadband radiation noise resulting in fluid-induced vibration and acoustic-induced vibration of pipe (배관의 유동 유발 진동 및 음향 유발 진동 기인 광대역 방사 소음 예측을 위한 수치 해석 기법 개발)

  • Sangheon Lee;Cheolung Cheong;Songjune Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.112-121
    • /
    • 2024
  • The pipping system is widely used in many industries as equipment for transporting fluids over long distances. In high-pressure pipe, as the speed of the fluid increases, a loud noise is generated. Therefore, various studies have been conducted to reduce pipe noise. In this paper, a pipe noise analysis was developed to predict and quantitatively assess the flow-induced vibration and acoustic-induced vibration due to valve flow in high-temperature and high-pressure. To do this, a high-fidelity fluid analysis technique was developed for predicting internal flow in the pipe with valve. In additional, the contribution of compressible/incompressible pressure by frequency band was evaluated using the wavenumber-frequency analysis. To predict a low/middle frequency pipe noise, the vibroacoustic analysis method was developed based on Finite Element Method (FEM). And the pipe noise prediction method for the middle/high frequency was developed based on Statistical Energy Analysis (SEA).

Tailpipe Noise Prediction of an Accelerating Vehicle (가속주행하는 차량의 배기 토출 소음 예측)

  • Kim Bong-Ki
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.291-294
    • /
    • 2000
  • Analysis of the contribution of each pass-by noise source to the overall pass-by noise is an important issue for reduction of pass-by noise. A technical approach for predicting tailpipe noise is used to identify the contribution of tailpipe noise to the pass-by noise in this study. Simulation program with a time domain engine modeling program called 'WAVE' and wave propagation theory of moving noise source are employed. Since the Doppler phenomenon causes a frequency shift during a pass-by noise test, the Doppler correction and time delay effects are incorporated into the estimation of tailpipe noise. The developed program can furnish an in-depth understanding of the effect of tailpipe to pass-by noise.

  • PDF

ISO/TC 43 2014 Berlin Meeting Report (ISO/TC 43 2014 베를린 총회 보고)

  • Jeong, Jeong Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.423-424
    • /
    • 2014
  • ISO/TC 43 Acoustics 총회는 약 18개월 주기로 개최되어 음향분야 국제표준의 제,개정을 논의하고 추진한다. 최근의 ISO/TC 43회의는 2014년 5월 19일부터 23일까지 독일 베를린 DIN에서 개최되었다. ISO/TC 43의 관련 작업반(WG 1, 8, 9)회의와 함께 ISO/TC 43/SC 1 Noise 및 ISO/TC 43/SC 2 Building Acoustics의 관련 WG 회의도 진행되었다. ISO/TC 43에서는 ISO 1999 소음성 난청 평가 관련 표준을 개정하였다. ISO/TC 43/SC 1 Noise에서는 도로용 자동차의 쿨링팬 소음 측정방법, 사격장에서의 청력손실 측정방법, 헤드? 사용시 소음레벨 가이드 라인에 대한 표준 제정에 대한 NP(New Proposal)이 채택되었다. ISO/TC 43/SC 2 Building Acoustics에서는 소음 방사 효율 측정방법에 대한 표준안 제정이 제안되었다. 또한 ISO 10848-1 ~ 4 개정안 추진이 의결되었다. 건축물의 소음 평가 등급(WG 27) 및 소음성능 표시제도(WG 29)와 관련된 회의가 새롭게 진행되었다. ISO/TC 43 및 관련 SC, WG 회의를 통해 음향, 소음 전반에 걸친 국제표준의 제,개정이 의결되었으나, 국내 전문가들의 관심과 적극 참여는 부족한 것으로 판단된다. 향후 음향, 소음의 기술 및 연구 선도를 위해서는 국제표준활동에 대한 적극적인 참여와 지원이 필요하다.

  • PDF

Sound Quality Characteristics for Interior Noise of High Speed Train (음질평가를 통한 고속철도 실내소음의 객관적, 주관적 특성 분석)

  • Park, Jun-Hong;Park, Buhm;Kim, Dong-Kyu;Choi, Sung-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.510-510
    • /
    • 2010
  • 우리나라에서 고속철도는 이미 중요한 대중교통수단 중 하나가 되었으며 향후에도 운행구간을 확대할 예정인 만큼 승객수도 더욱 증가할 것으로 보인다. 또한 승객수가 증가하는 만큼 정숙한 실내환경의 조성 또한 요구되고 있다. 하지만 현재 철도차량 소음에 관한 연구는 대부분 철도 외부에서 방사되는 소음에 한정되어 있으며 철도차량의 내부 소음 특성에 대한 연구는 미비한 상황이다. 현재 국내 환경소음에 대한 규정은 음압레벨만을 기준으로 하고 있지만 실제로 사람이 소음에 대하여 느끼는 청감특성을 나타내기에는 음압레벨만으로는 부족하다. 사람의 청감특성을 효과적으로 반영하기 위하여 음질(Sound Quality)평가의 방법에 대해 현재 활발하게 연구되고 있다. 본 연구에서는 국내에서 운행중인 고속철도 실내 소음의 특성에 대하여 연구하였다. 음압레벨과 loudness의 관계에 대하여 분석하였고 Zwicker parameter과 ACF, IACF 분석을 통하여 객관적인 음질평가를 실시하였다. 또한 청감실험을 통하여 주관적인 음질평가를 수행하여 청감특성에 대하여 분석하고 객관적 평가의 결과를 검증하였다.

  • PDF

Characteristics of Low Frequency Aero-acoustic Noise Radiation for a Wind Turbine Generator of NREL Phase VI (NREL Phase VI 풍력발전기 저주파 소음방사 특성)

  • Mo, Jang-Oh;Kim, Byoung-Yun;Ryu, Byeng-Nam;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.504-507
    • /
    • 2009
  • The purpose of this work is to predict the low frequency aero-acoustic noise generated from the horizontal axis wind turbine, NREL Phase VI using large eddy simulation and Ffowcs-Williams and Hawkings model provided in the commercial code, FLUENT. Calculated aerodynamic performances such as shaft torque and power are compared with experimentally measured value. Performance results show a good agreement with experimental data within about 0.8%. If the distance by two times is changed from 32D to 64D toward the downstream region, sound pressure level is reduced by about 6.4dB.

  • PDF