• Title/Summary/Keyword: 소음영향평가

Search Result 344, Processing Time 0.023 seconds

A Study on the Noise Assessment of Specific Vehicles at Metropolitan Landfill Area Using Noise Map (소음지도를 이용한 특정차량의 소음평가)

  • Park, In-Sun;Park, Sang-Kyu
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1064-1068
    • /
    • 2007
  • Around metropolitan landfill area, specific vehicles such as garbage carrying trucks make noise problems and residents near landfill area organized to protest. However, it is difficult to distinguish the effect of noise of specific vehicles (ex: garbage trucks). In this study, noise map and CRTN were used to assess the noise from specific vehicles. Noise levels, which were predicted by using measured parameters such as traffic flow, traffic speed, composition of traffic for 1 year, were compared with measured results of noise level.

Utilization of Noise Map in the Stage of Environmental Assessment on Development Project (개발계획 환경평가 단계에서의 소음지도 활용방안)

  • Sun, Hyo-Sung
    • Journal of Environmental Policy
    • /
    • v.9 no.3
    • /
    • pp.29-46
    • /
    • 2010
  • This study presents plans to prevent environmental noise by using noise maps when establishing development projects and targets strategic environment assessments for urban master plans and environmental impact assessment for urban development projects. Strategic environment assessments for urban master plans include the examination of plan validity and location appropriateness in consideration of the effect of environmental noise by comparing development plans with noise maps, and the establishment of long-term measures through comprehensive assessment of present noise conditions and noise effects from development plans. Environmental impact assessments for urban development projects propose enforcement plans, including analysis of present noise conditions around development areas, overall evaluation of present noise conditions and the noise effect from development projects, and selection of optimal measures by comparing noise maps with various alternatives.

  • PDF

Noise Assessmment in ETA: The Case of the DangJin Steam Power Plant (소음영향평가의 문제점과 개선방안-당진화력발전소건설을 위한 환경 영향평가를 사례로-)

  • 조기호
    • Journal of KSNVE
    • /
    • v.7 no.2
    • /
    • pp.281-291
    • /
    • 1997
  • This study analyzes the problem of environmental impact assessment for building steam power plants, particularly that of noise assessment for building the Dangjin steam power plant. It concludes that the laws and regulations for noise assessment and its methodology should be amended, and offers certain proposals.

  • PDF

Presentation on Health Impact Assessment of Transportation Noise (교통소음 건강영향평가 소개)

  • Sun, Hyo Sung;Park, Young Min
    • Journal of Environmental Policy
    • /
    • v.8 no.2
    • /
    • pp.63-82
    • /
    • 2009
  • Because many people suffer from physical and mental damage caused by the noise created by transportation infrastructure, including road traffic, rail, and aircraft, developed countries have conducted research on predicting and solving the impact to human health from being exposed to transportation noise. Therefore, this study suggests a fundamental plan to assess the health impact of transportation noise on the basis of domestic and foreign prediction results regarding the health impact of transportation noise. The domestic and foreign exposure-response expressions, including the noise index and the health impact indicator of annoyance and sleep disturbance, are compared, and it is found that domestic individuals show a more sensitive response to transportation noise. Based on domestic and foreign research, and a case study regarding the health impact of transportation noise, a fundamental plan to assess the health impact of transportation noise comprises the preparation of objective assessment standards through the improvement of exposure-response models, and the establishment of reduction measures which can improve the quality of the transportation noise environment.

  • PDF

환경영향평가 소음항목의 협의기준설정에 대한 필요성

  • 박영민
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.350.1-350
    • /
    • 2002
  • 소음문제 중 도로교통소음은 가장 다루기 힘든 환경문제로 대두되고 있는 실정이다. 도로교통소음은 도시민에게 직접적인 영향을 끼치고 있어서 우리나라를 포함하여 세계 각국에서 이에 대한 소음규제가 이루어지고 있으면서 환경영향평가나 환경행정목표를 달성하기 위하여 소음기준을 마련하고 띤다. 환경기준은 정부가 지향하는 일종의 목표수준으로서 환경질의 표준과 목표(goal)에 해당하며, 환경오염대책 추진에 있어 행정상의 목표일뿐이기 때문에 가능한 한 이상상태를 생각하여 설정된다. (중략)

  • PDF

Comparison of Evaluation Methodsfor Receiver Setting and Representative Noise Level Selection in Calculating Population Exposed to Noise (소음예측 모델링을 이용한 소음노출인구산정 시 수음점 설정 및 대표소음도 평가방법에 따른 비교)

  • Yun, Hee-Kyung;Lee, Jae-Won;Kwon, Myung-Hee
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.2
    • /
    • pp.105-113
    • /
    • 2018
  • The modeling of noise mapping and the evaluation of noise pollution based on the exposed population were frequently used as an indicator of environmental noise assessment to overcome the limitations of field survey and Tele-Monitoring System. Results from these methods were highly influenced by the setting of noise source, input data of prediction factors and analytical methods of predictive values. The population exposed to noise were estimated as M1-1>M2-1>Base>M2-2>M1-2 in both areas. The highest noise setting methods(M1-1, M1-2) were overestimated, being compared with the Base method.

The noise influence evaluation and countermeasure to the high-rise building by cooling tower noise (냉각탑 소음에 의한 고층건물 내외부에서의 소음영향평가 및 대책)

  • Yoon, Je-Won;Lee, Hong-Ki;Son, Sung-Wan;Ryu, Kuk-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1024-1027
    • /
    • 2004
  • 수원 삼성전자 DM연구소(R4) 신축동 6층 옥상에 위치한 냉각탑으로 인해 인근 연구실 및 사무실에 소음 전파 우려가 있어 이에 대한 소음영향 평가를 수행하고 대책을 수립하고자 한다. 이를 위해 연구실에 대한 소음기준을 설정하고 음향해석기법을 이용하여 방음대책 수립 전 후에 대한 소음영향 평가를 수행하였으며, 냉각탑 소음을 줄이기 위한 방음대책안을 제시하였다.

  • PDF

소음. 진동 피해진단 기술 정립방향

  • 백용진;이중선;배동명
    • Journal of KSNVE
    • /
    • v.7 no.2
    • /
    • pp.189-198
    • /
    • 1997
  • 현재 행해지고 있는 환경 기술자에 의한 공해성 환경영향평가와 택지조성사업, 터널공사, 각종 도로공사, 건물 해체 작업시 이루어지는 발파 기술자에 의한 발파 영향평가 및 토목. 건축 기술자들에 의해 시공현장에서 주로 행해지는 기타 건설 소음. 진동 영향평가는 진단 개념에서 볼 때, 측정목적과 측정대상에 따른 각종 기준적용과 측정방법 및 분석절차 상에서 몇가지 문제점을 안고 있으며 실제 현장 계측시에도 측정위치 선정, 센서부착 방법, 측정 횟수 및 측정 모드 선정 등에서 상당한 오류를 범하는 것을 종종 볼 수 있다. 따라서 본 연구에서는 각종 소음. 진동 영향평가의 현실태 및 피해 대상물에 대한 진단시 우려되는 기준 적용, 측정 및 분석상의 문제점들을 조사하고 개선방안을 살펴봄으로써 소음. 진동 피해진단 기술을 정립하고 향후과제에 대해 논의하고자 한다.

  • PDF

New Approaches to Assessing the Effects of Environmental Noise arid Vibration on Human (환경 소음ㆍ진동의 인체영향 평가에 대한 새로운 접근)

  • 정완섭;김용태
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.768-771
    • /
    • 2002
  • 국외 환경 소음과 진동은 이미 세계보건기구(WHO)와 UN산하 환경기관에서 선언한 바와 같이 “전세계인의 문제”(“global issues”)로 분류 인식하고 있으며, 이들 문제점들에 대한 접근은 선진국들의 국민 복지정책의 가장 핵심적 요소로 관리하고 있다. 예를 들어, WHO가 출판한 공중소음에 대한 지침서[1], 그리고 유럽공동체의 전문가 그룹이 작성한 보고서[2]들은 최근의 환경소음에 대한 새로운 접근의 필요성, 새로운 측정 및 평가 방법, 그리고 인체에 미치는 복합적 영향들의 새로운 평가 기법 개발, 그리고 환경 개선을 위한 장기적 계획과 실천 방안들을 구체적으로 제시하고 있다.(중략)

  • PDF

Noise influence Coming to Existing Neighborhood Area by Extension of Power Site and Noise Reduction Service (발전소 증절이 부지경계의 가존 지역에 미지는 소음영향과 저감 대책)

  • Kim, Yeon-Whan;Goo, Jae-Rayng;Bae, Chun-Hee;Kim, Kye-Yean;Yang, Dong-Cheol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.716-722
    • /
    • 2009
  • 4000MW급 유연탄발전소는 기존 500MW급 4기의 발전설비 운영조건에서 지역공동체는 긍정적이었으나, 500MW급의 증설 호기가 늘어나면서 지역 공동체는 발전소 증설과 관련하여 기존 동쪽 부지 경계지역의 소음환경에 대하여 부정적인 문제를 제기하였다. 2000MW급 증설이 진행되어온 4000MW급 발전소의 다양한 소음원에 의한 소음파워 증대와 증가방출 과도소음 에 대하여 고저가 다양한 주변지역에 미치는 영향음 평가하고자 3차원 모델링기법을 적용한다. 기존호기를 비롯한 전체의 발전소 전면부 소음원응 비교 시험결과 증가방출 소음 파워가 기존 설계의 변경 제작되어 기존호기에 비해 20~30dBA 높아져 동시 방출사 주변지역에 과도하게 영향을 미치는 상태였으며 500MW급 4기를 추가 증설에 따라 일상소음원에 의한 소음 영향도 증설전 대비 2~3dBA 증가된 것으로 평가되었다. 따라서 증설호기의 과도 소음원 제거 방안으로 대가 방출증가가 회수되도록 증설호기의 증가방출설비를 개선하였고, 증설에 의하여 증가된 소음 영향음 저감하고자 기존 경계지역에 미치는 소음원음 고려하여 방음벽음 설치한 결과 47 ~ 49dBA를 나타내고 인근 주거건물의 전면부 소음은 43dBA이었다.

  • PDF