• Title/Summary/Keyword: 소요 에너지

Search Result 1,203, Processing Time 0.027 seconds

Energy Consumption in Vacuum-Press Drying of Some Softwood Lumbers of Different Thicknesses (침엽수 제재두께별 가열판 압체식 진공건조의 소요 에너지)

  • Jung, Hee-Suk;Lee, Jun-Ho;Kang, Wook;Lee, Nam-Ho
    • Journal of the Korean Wood Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.9-15
    • /
    • 2001
  • Specific energy curves for water removal in vacuum-press drying of different thick softwoods of red pine (Pinus densiflora), white pine (Pinus koraiensis), larch (L. leptolepis) and Western hemlock (Tsuga heterophylla) were split into three sections: increased slowly, fairly constant, and increased rapidly. Calculated specific energy for 3, 5, 7, 9 and 11cm thick lumber was a value of 0.483, 0.649, 0.814, 0.977 and 1.138kWh/kg of water, respectively. Specific energy almost linearly increased as lumber thickness increased, and specific energy for severe schedule was less than that for mild schedule. Average specific energy was 0.712kWh/kg and vacuum-press drying consumed less energy as compared with any other drying methods.

  • PDF

Effects on Immune Cell of Short-term Aerobic Exercise by Exercise Intensity and Expenditures Calorie (운동 강도와 에너지소비량에 따른 단기간의 유산소운동이 면역세포에 미치는 영향)

  • Lee, Jung-Ja;Cho, Jung-Yeon
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.386-394
    • /
    • 2008
  • The study of subjects were 8 persons. The study measured VO2max of each person and substituted METs at exercise intensity of both VO2max 50% and VO2max 70% in accordance with energy consumption formula to set exercise time at energy consumption of both 300kcal and 600kcal. And, the study substituted inclination and rate at exercise intensity that was measured at preliminary test. T, B, NK cell varied depending upon aerobic exercise to have no significant difference of exercise intensity at relative ratio of T, B, NK lymphocyte of all of lymphocytes and to have significant difference of Expenditures Calorie (p<.01) and interaction (p<.05) by T cell and Expenditures Calorie (p<.01) by B cell and Expenditures Calorie (p<.001) and interaction (p<.05) by NK cell.

Accidents Analysis of Domestic and Overseas Refueling Stations and Assessment of Dangerous Distance by Gas Leak (국내·외 충전소 사고 현황 분석 및 가스누출 피해거리 평가)

  • Kim, Hyelim;Kang, SeungKyu;Huh, YunSil
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.7-13
    • /
    • 2017
  • As environmental problems become a problem of survival, interest in eco-friendly energy is increasing to improve the environment. So, demand for eco-friendly fuels such as hydrogen, LPG and CNG is increasing. In particular, Korea, which relies on imports of most fuels, is investing in the development of hydrogen energy, which is favorable in terms of high production volume and energy independence. However, As demand grows every year, a variety of accidents occur in various ways, ranging from small leak incidents to massive fires and explosion, thus research needs to be done. So, in this study, compared and analyzed cases of hydrogen, LPG, CNG accidents occurring at domestic and overseas refueling stations. and various programs were used for assessing risk, estimated the flame length due to gas leakage and evaluated the dangerous distance.

Analysis of Environmental Design Data for Growing Pleurotus ervngii (큰 느타리버섯 재배사의 환경설계용 자료 분석)

  • Yoon, Yong-Cheol;Suh, Won-Myung;Lee, In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.14 no.2
    • /
    • pp.95-105
    • /
    • 2005
  • This study was carried out to file up using effect and requirement of energy for environmental design data of Pleurotus eryngii growing houses. Heating and cooling Degree-Hour (D-H) were calculated and compared for. some Pleurotus eryngii growing houses of sandwich-panel (permanent) o. arch-roofed(simple) type structures modified and suggested through field survey and analysis. Also thermal resistance (R-value) was calculated for the heat insulating and covering materials of the permanent and simple-type, which were made of polyurethane or polystyrene panel and $7\~8$ layers heat conservation cover wall. The variations of heating and cooling D-H simulated for Jinju area was nearly linearly proportional to the setting inside temperatures. The variations of cooling D-H was much more sensitive than those of heating D-H. Therefore, it was expected that the variations of required energy in accordance with setting temperature or actual temperature maintained inside of the cultivation house could be estimated and also the estimated results of heating and cooling D-H could be effectively used far the verification of environmental simulation as well as for the calculation of required energy amounts. When the cultivation floor areas are all equal, panel type houses to be constructed by various combinations of materials were found to by far more effective than simple type pipe house in the aspect of energy conservation maintenance except some additional cost invested initially. And also the energy effectiveness of multi-span house compared to single span together with the prediction of energy requirement depending on the level insulated for the wall and roof area could be estimated. Additionally, structural as well as environmental optimizations are expected to be possible by calculating periodical and/or seasonal energy requirements for those various combinations of insulation level and different climate conditions, etc.

Operaton Cost Model for Feed Production (배합사료 공장의 작동비용 모델)

  • Park, Kyung Kyoo;Chung, Do Sup;Charles, Deyoe
    • Journal of Biosystems Engineering
    • /
    • v.10 no.1
    • /
    • pp.69-75
    • /
    • 1985
  • For the purpose of estimating the operating cost for feed production, energy consumption, labor requirement, maintenance cost, and supplies and miscellaneous costs are analyzed and developed as mathematical models. Mathematical model for energy usage Consists of electrical energy, boiler fuel energy and vehicle fuel energy. The mathematil model for electrical energy usage for the swine and poultry feed mill and the complete pelleted feed mill are developed, based on the general model mill and the computer program for its design developed in Kansas State University (Park, 1982). Also, the boiler fuel energy consumption model and the vehicle fuel energy consumption model are developed by analyzing the boiler system and the vehicle operation in the warehouse. In order to develop a mathematical model for labor requirement, the data that Vosloh (1968, 1976) constructed for labor requirement in his model mill are used by assuming that his model mill is similar to this model, in terms of labor assignment standards. Maintenance and repair costs are obtained by assuming to be 5.5% of the total capital investment cost. Also, supplies and miscellaneous costs are estimated by using Vosloh's report and it is approximately 0.87 dollars per ton based on daily production.

  • PDF

Building Energy Management System with Next Day Demand Forecasting of Building Load (익일 빌딩 부하 예측 기능을 갖는 빌딩에너지관리시스템)

  • Choi, Sang-Yule
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.119-123
    • /
    • 2014
  • The main purpose of reactive power compensation monitoring system is to manage factory electrical installation efficiently by On-Off switching reactive power compensation equipment. The existing reactive power compensation monitoring system is only able to be managed by operator whenever electrical installation needed reactive power. Therefore, it may be possible for propagating the installation's faults when operator make the unexpected mistakes. To overcome the unexpected mistakes, in this paper, the author presents a reactive power compensation monitoring system for factory electrical installation using active database. by using active database production rule, stated system can minimize unexpected mistake and can operate centralized monitoring system efficiently. Test results on the five factory electrical installations show that performance is efficient and robust.

$D_2$ Adsorption on Ti-deposited Metal Organic Frames

  • Sa, Gong-Gil;Lee, Ji-Hwa
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.312-312
    • /
    • 2011
  • 초고진공 장치 내에서 질량분석기와 티타늄 증착기를 이용하여 IRMOF-3에 증착된 티타늄과 수소 간의 흡착 특성을 TPD (Temperature Programmed Desorption)을 통하여 연구하였다. 티타늄을 흡착시키지 않은 순수한 IRMOF-3에 35K에서 주입한 중수소에 대한 TPD 데이터에서는 중수소가 저온 장치에 물리흡착된 약 50K에서의 작은 피크 이외에는 다른 흡착 특성을 보이지 않는다. 하지만 티타늄 2ML (Monolayer)를 흡착 시킨 IRMOF-3의 TPD 데이터에서는 약 60K와 95K에서의 두 피크가 보인다. 이는 분산된 티타늄과 중수소 사이에는 0.16eV와 0.25eV의 결합에너지를 가지는 두 가지의 다른 결합이 있다는 사실을 보여준다. 그리고 40K~110K에서 수소와 HD는 나오지 않고, 중수소만 나온 점은 주입한 중수소가 IRMOF-3에 분산된 티타늄에 쿠바스 상호작용에 의하여 분자상태로 화학 흡착되어 있을 것이라는 증거가 된다.

  • PDF

심해파랑의 비선형상호작용에 의한 에너지 전달의 계산

  • 오병철;이길성
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.119-123
    • /
    • 1996
  • 파랑성분간의 비선형상호작용에 의한 에너지의 교환은 스펙트럼 파랑에너지 보존방정식의 중요한 원천항(source)의 하나이며 이의 정확한 계산에 관한 연구가 파랑모델에서 중요한 문제로서 제기되어 왔다. 그러나 비선형에너지 전달을 엄밀하게 계산하는데는 많은 시간이 소요되기 때문에 현재 현업에서는 스펙트럼파라메타로서 간략화한 식을 사용하고 있다. 비선형상호작용은 파랑이 발달하고 있는 풍역에서 중요하기 때문에 비대칭 스펙트럼에 대한 비선형상호작용의 파라메터화는 풍속이 급변하는 풍장에서 매우 중요하다. (중략)

  • PDF

Evaluation on Thermal Performance Along with Constructability and Economic Feasibility of Large-diameter Cast-in-place Energy Pile (대구경 현장타설 에너지파일의 열교환 성능과 시공성 및 경제성 분석)

  • Park, Sangwoo;Sung, Chihun;Lee, Dongseop;Jung, Kyoungsik;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.5
    • /
    • pp.5-21
    • /
    • 2015
  • An energy pile is a novel type of ground heat exchangers (GHEX's) which sets up heat exchange pipes inside a pile foundation, and allows to circulate a working fluid through the pipe for exchanging thermal energy with the surrounding ground stratum. Using existing foundation structure, the energy pile can function not only as a structural foundation but also as a GHEX. In this paper, six full-scale energy piles were constructed in a test bed with various configurations of the heat exchange pipe inside large-diameter cast-in-place piles, that is, three parallel U-type heat exchangers (5, 8 and 10 pairs), two coil type heat exchangers (with a 500 mm and 200 mm pitch), and one S-type heat exchanger. During constructing the energy piles, the constructability of each energy pile was evaluated with consideration of the installation time, the number of workers and any difficulty for installing. In order to evaluate the thermal performance of energy piles, the thermal performance tests were carried out by applying intermittent (8 hours operating-16 hours pause) artificial cooling operation to simulate a cooling load for commercial buildings. Through the thermal performance tests, the heat exchange rates of the six energy piles were evaluated in terms of the heat exchange amount normalized with the length of energy pile and/or the length of heat exchange pipe. Finally, the economic feasibility of energy pile was evaluated according to the various types of heat exchange pipe by calculating demanded expenses per 1 W/m based on the thermal performance test results along with the market value of heat exchange pipes and labor cost.

초전도 에너지저장장치

  • 증전정미
    • 전기의세계
    • /
    • v.34 no.5
    • /
    • pp.261-271
    • /
    • 1985
  • 초전도 에너지 저장장치의 경제성 또는 도모는 초전도 코일 선재의 임계치의 상승에 의한 재료절약 quench방지를 위한 열절연지 지재 및 지지방법의 개발, 양호한 운전특성 및 효율을 위한 전력계통과의 인터페이스 부분의 부품 및 제어방법 개발, 냉각계통의 열절연 및 냉각효율 향상, He의 소요량 감소 및 회수 방법의 개발등에 대하여 계속 연구중에 있으며 2000년대 초반에 현재의 양수발전 규모가 실용화될 전망이다.

  • PDF