• Title/Summary/Keyword: 소아 권고가이드

Search Result 8, Processing Time 0.023 seconds

Comparison of ESD and Major Organ Absorbed Doses of 5-Year-Old Standard Guidelines and Clinical Exposure Conditions (소아 5세 표준촬영 가이드라인과 임상 촬영조건의 입사표면선량과 주요 장기흡수선량 비교)

  • Kang, A-Rum;Lee, In-Ja;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.355-361
    • /
    • 2017
  • Pediatrics are more sensibility to radiation than adults and because they are organs that are not completely grown, they have a life expectancy that can be adversely affected by exposure. Therefore, the management of exposure dose is more important than the case of adult. The purpose of this study was to determine the suitability of the 10 year old phantom for the 5 year old pediatric's recommendation and the incident surface dose, and to measure the organ absorbed dose. This study is compared the organ absorbed dose and the entrance surface dose in the clinical conditions at 5 and 10 years old pediatric. Clinical 5 year old condition was slightly higher than recommendation condition and 10 year old condition was very high. In addition, recommendation condition ESD was found to be 43% higher than the ESD of the 5 year old group and the ESD of the 10 year old group was 126% higher than that of the 5 year old group. The recommended ESD at 5 years old and the ESD according to clinical imaging conditions were 31.6%. There was no significant difference between the 5 year old recommended exposure conditions and the organ absorbed dose due to clinical exposure conditions, but there was a large difference between the Chest and Pelvic. However, it was found that there was a remarkable difference when comparing the organ absorbed dose by 10 year clinical exposure conditions. Therefore, more detailed standard exposure dose for the recommended dose of pediatric should be studied.

A Survey on the Radiation Exposure Doses Reduction Plan through Dose Index Analysis in the Pediatric Brain Computed Tomography (소아 두부 컴퓨터단층촬영검사에서 선량지표 분석을 통한 방사선 피폭선량 감소 방안에 대한 연구)

  • Kim, Hyeon-Jin;Lee, Hyo-Yeong;Im, In-Chul;Yu, Yun-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.161-169
    • /
    • 2016
  • In this study, the proposal to seek ways to reduce the amount of radiation is drawn by comparing and analyzing CT Dose Index(CTDI) on the pediatric head CT which was performed at the busan regional hospitals, to the national diagnostic reference levels. As a result, it was appeared to exceed the amount of the dose recommendation in order of hospital, general hospital and senior general hospital in the hospital-specific classification and from 2 to 5 year, from 1 month to 1 year and from 6 to 10 year in the age-specific classification. In addition, the amount of the dose recommendation was exceed in order of helical, axial and volume in the scan-specific classification. As the results of the scan range reset to match the diagnostic reference level, the dose reduction showed 11.68%, 15.79% and 20.66% in senior general hospital, general hospital and hospital respectively. In the results of analysing patient average scan ranges which does not deviate from the guideline of patient dose recommendation, there was age of 1 month to 1 year, 2 to 5 year and 6 to 10 year of $03.2{\pm}11.8mm$, $110.5{\pm}14.5mm$, and $117.8{\pm}17.2mm$ respectively.

Exposure Dose of DIPS in Proton Therapy for Pediatric Cancer Patients (소아암 환자의 양성자치료 시 DIPS 촬영에 따른 피폭선량)

  • Kim, Jeong-Soo;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.59-64
    • /
    • 2011
  • We investigated the radiation exposure caused by DIPS, which is used to identify accurate repositioning and tumor location in pediatric cancer patients proton therapy. To compare and analyze DIPS condition, 50 pediatric cancer patients who underwent proton therapy were selected in Ilsan K cancer-specialized hospital from March 2007 to October 2009. For DIP exposure, 0.09~1.57 mGy is measured in AP and lateral directions and 23.55 mGy is measured in CSI patients. In whole brain patient, the amount of a day DIP exposure dose was 1.13 mGy. During treatment period, who exposed the biggest DIP dose are whole brain patients, 632.71 mGy is exposed. It is 1.13% of prescribed dose, represented dose is adequate because it is not exceeded 2% of recommended dose. Even though the exposed dose is not exceeded more than 2% of prescribed in DIP exposure, we should recognize the radiation damage and genetic influences to pediatric cancer patients, who is much sensitive to radiation and has longer mean residual life time. Therefore, DIPS guideline for pediatric cancer patients should be indicated to minimize the radiation exposure.

Management Strategies for Electromagnetic Fields in Electric Power Lines (고압선로에서 발생하는 전자기장의 위해성 관리 방안)

  • 전인수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.10
    • /
    • pp.1017-1023
    • /
    • 2003
  • Recently, the use an electric apparatus has brought into concerns about health risks from exposure to electromagnetic fields. During the last 2 decades, a number of epidemiological studies have explored the association between childhood leukaemia and residential exposure to power-frequency electromagnetic fields. Several studies have suggested that there is a small excess leukaemia risk with magnetic field exposure above 2 mG. A number of governmental and international organizations have developed exposure gudelines. The most rigid regulation with exposure levels for the elementary school and hospital has been enacted by Switzerland. Although there is no convincing supportive laboratory evidence, and the absence of a plausible biological mechanism of disease causation limits, governments are increasingly called on to adopt precautionary approaches to regulating electromagnetic field exposures. The government would need to establish the policy for electromagnetic fields and continually to be concerned about possible health risks from exposure to electromagnetic fields.

Legal Issues in Clinical Trial on Minor (미성년자 대상 임상시험에 관한 법적 문제점)

  • Song, Young-min
    • The Korean Society of Law and Medicine
    • /
    • v.17 no.2
    • /
    • pp.125-144
    • /
    • 2016
  • All forms of Clinical trial should be fully equipped with protection systems for experimental subjects considering their uncertainty and various risks. Existing laws have some regulations in pharmaceutical affairs act and medical device act. Nonetheless, there is a limit to protect the subjects considering law objective to perform administration of medicine. Furthermore, the clinical trial on minor has no direct regulations in pharmaceutical affairs act, but prescribes certain portion in clinical trial assessment guideline on infants or medicine clinical trial management standard, however there is a limit because that is just recommendation not having legal effectiveness. The legislative solution would be possible for legal problems of clinical trial on minor by examining treatment system on minor in organ transplant act and clinical trial on minor in other foreign laws stronger than usual medical practice in terms of degree of human body invasion. I suppose that the control system of clinical trial being done focusing on the pharmaceutical affairs act, medical device act and other guidelines in existing laws system should be resolved by legislating 'trial subject protection law', in addition, this would be well balanced in organ transplant act on protection system of minor organ donors. Furthermore, the judgement on the consent ability and spontaneity in clinical trial on minor should be judged considering maturity and mentality of minor by clinical trial institutional review board based on legislative solution mentioned above.

  • PDF

The Changes of Smart Device Usage Status in Early Childhood: Comparison of 2015-2016 and 2017 Studies (유아 스마트 기기 사용 현황의 변화: 2015-2016년과 2017년의 연구 결과 비교)

  • So, Hyejin;Lim, Sungmin;Cho, Sang Yeun;Koh, Min Suk;Moon, Jin-Hwa
    • Journal of the Korean Child Neurology Society
    • /
    • v.26 no.4
    • /
    • pp.251-262
    • /
    • 2018
  • Purpose: This study aimed to identify changes in smart device usage trends of young children using two studies conducted in 2015-2016 and 2017 respectively. Methods: We compared the data of the previous study of 130 children (Group A) and the new study of 162 children (Group B). The children and parents were recruited from kindergartens in Seoul and Guri/Namyangju cities. We used the "Parental questionnaire for smart device usage status." Results: There were some changes in the smart device usage in young children and parental perception. In the 2017 study, smart device usage time increased during weekends (P<0.05) and the usage with siblings decreased (P<0.05). In 2017, the smart device was mostly used when children had to be quiet without disturbing others (36.8%). No significant difference existed in the main purpose of use: watching video clips (79.3% vs 76.6%). Overall control of the usage was still largely exercised by mothers; however, when using applications, mothers still only helped the children on request (51.8% vs 49.7%). Regarding the effect of smart device on children, responses of "not knowing" decreased and "will be negative" and "will be positive" increased (P<0.05). Additionally, most mothers thought that "Although the smart device is currently unnecessary, it will be needed in future" in 2017 (46.3%). Conclusion: Limiting the smart device usage time during the weekends and increasing parental involvements are recommended. Guidelines for smart devices usage in young children are also necessary considering the changes in parental attitudes in recognizing the smart device usage as unavoidable.

Fibromyalgia from the Psychiatric Perspective (정신과적 관점에서의 섬유근통)

  • Lee, Yunna;Lee, Sang-Shin;Kim, Hyunseuk;Kim, Hochan
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.28 no.2
    • /
    • pp.99-107
    • /
    • 2020
  • Fibromyalgia is a disorder characterized by the core symptom of chronic widespread pain, along with fatigue, sleep disturbances, mood changes, and cognitive difficulties. The etiology of fibromyalgia involves a combination of biological factors, such as genetic vulnerability, alterations in pain processing and stress response system ; psychological factors, such as anxiety, depression, anger, and perceived stress ; environmental factors, such as infections, febrile diseases, and trauma. Central sensitization, which is amplified in the process of sensory stimulation, has been emphasized as a key etiological factor, as supported by enhanced wind-up, delayed aftersensation, decreased nociceptive flexion reflex threshold and functional imaging studies. Several guidelines recommend that a multimodal approach be used to treat fibromyalgia, including both pharmacological and non-pharmacological treatments, tailored to each individual, and that clinicians should provide an intellectual framework through sufficient education and emphasis on the importance of self-management. The prevalence of mood disorders, anxiety disorders, and other psychiatric problems is 7-9 times higher in patients with fibromyalgia than in the general population ; moreover, the association between fibromyalgia and certain psychopathologies or sleep problems has also been suggested. Since psychiatric problems, with shared vulnerabilities and risk factors, interact with fibromyalgia bidirectionally and also affect the disease course, an integrated management approach is needed to determine the risk of comorbidities.

Guideline for Imaging Dose on Image-Guided Radiation Therapy (영상유도방사선치료에 있어 영상선량 가이드라인)

  • Cho, Byung Chul;Huh, Hyun Do;Kim, Jin Sung;Choi, Jin Ho;Kim, Seong Hoon;Cho, Kwang Hwan;Cho, Sam Ju;Min, Chul Kee;Shin, Dong Oh;Lee, Sang Hoon;Park, Dong Wook;Kim, Kum Bae;Choi, Sang Hyoun;Kim, Hye Young;Ahn, Woo-Sang;Kim, Tae Hyeong;Han, Su Cheol
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.1-24
    • /
    • 2013
  • As image-guided radiation therapy (IGRT) has been commonly used for more accurate patient setup and monitoring tumor movement during radiation therapy, the necessity for management of imaging dose is increased. However, it has not been an interest issue to radiation therapy communities because the imaging dose is much lower than the therapeutic dose. However, since the cumulative dose from 4DCT and repeated imaging for daily setup verificationin would not be ignorable, appropriate dose management based on ALARA (As Low As Reasonably Achievable) principle is required. In this study, we aimed that (1) survey on imaging equipments and modalities used for IGRT, (2) estimation of IGRT imaging dose depending on treatment types and equipments, (3) collecting data of effective dose on treatment sites from each equipment and imaging protocol, and thus finally provide guideline for imaging dose reduction and optimization.