• Title/Summary/Keyword: 소방장비

Search Result 155, Processing Time 0.029 seconds

The Key Points of Architectural Planning for Floating Residential Architecture (플로팅 주거건축의 주요 건축계획 항목에 관한 연구 -플로팅 건축 관련 기준 및 주거건축 해외 사례를 중심으로-)

  • Song, Seog-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.5281-5289
    • /
    • 2013
  • This study aims to identify the key points of architectural planning for floating residential architecture. For this purpose, this study analyses 6 kinds of standards about floating architecture and 14 cases of floating residential architecture. As a result, this study finds out 4 points of architectural planning for floating residential architecture; first, planning of access to upland and walkway, second, public facilities and community space planning, third, planning of various equipment, material and fixed extinguishing system for fire prevention, forth, modular system planning including manufacturing, transporting and installation of modular house.

차량용 강우 센서의 신호체계(signal)와 관측자료와의 상관관계 분석을 통한 회귀식 개발

  • Kim, Young Gon;Jung, Se Jin;Lee, Suk Ho;Kim, Byung Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.218-218
    • /
    • 2016
  • 차량용 강우 센서는 강우측정이 어려운 지역의 강수량 측정이 가능하고, 실시간으로 강우정보를 생성해 내기 때문에 차세대 강우측정기로써 전망이 기대된다. 차량용 강우 센서는 일반적인 강우관측기와 달리 물 입자가 커질수록 빛의 산란이 크게 일어나는 현상을 이용한다. 산란이 크게 일어나면 강우 센서에 입력되는 값이 줄고 이는 강수가 높다는 것을 의미한다. 강우가 발생하면 자동차 전면 유리창에 부착된 강우 센서가 감지하는 우적량을 강우량으로 환산하는 방법을 통해 강우량을 산정한다. 강우가 쌓이고 나서 나중에 그 값을 측정하는 것이 아니라 즉시 그 값을 계산하여 강우량을 산출해야하기 때문에 단계가 복잡하다. 수식이 복잡할수록 오차가 발생할 확률도 크고 처리 속도도 느려지기 때문에 W-S-R 관계식을 이용하여 복잡한 수식을 간단하게 정리할 필요가 있다. AWS 기상관측소와의 비교 분석을 위해 차량에 우량계를 장착하였으며 W-S-R 관계식을 통하여 상관관계 분석하여 회귀식을 도출 한다. W-S-R 관계식이라 함은 와이퍼의 속도관계(W), 강우센서(S), 실제 강우(R)을 의미한다. 여기서 와이퍼의 속도관계는 와이퍼의 한 번 이동 했을 시 실제 강우는 실내강우발생 장비를 제작하여 10~80mm의 강우를 발생시키고 그 값은 우량계로 관측한다. 본 연구에서는 물 입자의 산란과 차량용 강우 센서 간의 관계식 도출과 W-S-R 관계식을 이용하여 실제 강우 정보와의 상관관계를 위한 분석을 통한 회귀식 개발을 목표로 한다.

  • PDF

Experimental Study on the Toxicity Characteristics of Non-Class 1E Cables according to Accelerated Deterioration (가속열화에 따른 비안전등급 케이블의 독성특성에 관한 실험적 연구)

  • Jang, Eun-Hui;Kim, Min-Ho;Lee, Min Chul;Lee, Sang-Kyu;Moon, Young-Seob
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.105-113
    • /
    • 2019
  • This study investigates the toxicity characteristics of two Non-Class 1E Cables (For security reasons, we refer to company A and company B) used in nuclear power plants according to the accelerated deterioration period. In accordance with NES 713 test equipment and standards, tests were carried out on non-aged cables and the cables subjected to 20- and 40-year-accelerated-deterioration; each of the cables was further classified into sheath and insulation. The test results showed that the toxicity indices of 20- and 40-year-accelerated-aged cables were higher than those for the non-aged cables, and 20-year-aged cables of both A and B companies showed the highest toxicity indices. This is attributed to the extensive emissions of carbon monoxide and halide gases such as hydrogen chloride and hydrogen bromide. Furthermore, to analyze the toxicity indices of sheath and insulation in detail, the US Department of Defense standard (MIL-DTL) was applied to determine whether the Toxicity index (T.I.) allowance was exceeded, and the results showed that the insulating materials emitted considerably more than the allowable limit.

A Study on Measures to Improve Smoke Control Performance in Case of Fire in a Clean room as an LCD Manufacturing Process (LCD 제조공정 클린룸의 화재시 CFD를 이용한 제연성능 개선대책에 관한 연구)

  • Son, Bong-Sei;Jang, Chan-Hee
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.41-47
    • /
    • 2012
  • As a core process in the manufacture of state-of-the-art industrial technologies such as semiconductor and LCD, a clean room is the most important process which can affect the performance and quality of products drastically. Nevertheless, scientific research on comprehensive safety measures from a fire protection standpoint is not being carried out in Korea. This study aims to derive measures to improve smoke control systems by identifying performance and problems of smoke systems installed in clean rooms as an LCD manufacturing process and analyzing fire and evacuation simulations considering several scenarios. As a result of analysis of fires and smoke in a clean roomas an LCD manufacturing process, it is found to be necessary to stop air handling units through interlocking in case of a fire and exhaust smoke out of the room through the top of FAB in consideration of buoyancy of smoke. It is also found to be necessary to install quick response sprinkler heads and accessories to accelerate the response time, because the heat-accumulating performance of sprinkler heads decreases in this application. Despite its low density of dwelling due to the automation process, clean room is characterized by an array of complex production equipment and working environment requiring dustproof clothes, which makes it difficult to acquire evacuation safety performance. Thus, thorough control of danger factors in processes and periodic education and training are required. It is also necessary to establish a level of domestic technologies equivalent to the level of standards of advanced countries in fire protection.

The Evaluation of Musculoskeletal Symptom and Patient Transport Work of 119 EMTs by Ergonomics Tools (119구급대원의 근골격계 증상과 환자운반 작업의 인간공학적 평가)

  • Hong, Sung-Gi
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.81-88
    • /
    • 2014
  • This study identified the complaint ratio of musculoskeletal symptom by 119 EMTs and investigated the work risk extent through ergonomics evaluation about the patient transport works, which cause work-related musculoskeletal disorders (WMSDs) to 119 EMTs. For this, the complaint ratio of musculoskeletal symptom utilized questionnaire tool based on KOSHA Code H-30-2008 and the risk extent about the patient transport work evaluated by using ergonomics evaluation tools such as OWAS, RULA and REBA. According to the study result, 60.9% of 119 EMTs experienced musculoskeletal symptom. Among them, the symptom on back was the most common (36.1%). The work, which mostly causes WMSDs, has been found as patient transport work (48.4%). Among the patient transport motion, loading/unloading of ambulance cot to/from ambulance and the lifting of patient by stretcher were OWAS risk-level 3 and RULA/REBA risk-level 3 to 4. Among the patient transport environment, carrying patient on stairway using emergency mini-stretcher, moving patient in vehicle using spine board and piggy-back carrying or cradle carrying patient on stairway or slope way were OWAS, RULA, REBA risk level 3 to 4. It is suggested that immediate improvement in work postures for these works should contribute to prevention against WMSDs to 119 EMTs.

An Experimental Study on the Automobile Engine Room Fire Using the Extinguishing Agents (소화약제를 이용한 자동차 엔진룸 화재 실험에 관한 연구)

  • Han, Yong-Taek;Kim, Dong-Ho;Kwon, Sung-Pil
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.1-7
    • /
    • 2014
  • Several complex devices and equipments are installed in the car's engine room, including various kind of oils or other flammable materials. So re-ignition is very likely to take place in it. In addition, it is restrictive for the driver or the occupant to open the bonnet and to spray the fire extinguisher in the engine room due to the high possibility of explosion. Therefore, a fire extinguishing system, which can detect a fire and inject the fire extinguishing agent to extinguish it, and fire extinguishing agents including HFC-227ea, which can stand the high temperature within the engine room and hold the viscosity sufficient to keep it in the kind of foam, were developed and tested. And the suffocation effect and the cooling effect come from the fire extinguishing principle of the foam fire extinguishing agent and the inhibiter catalyst effect come from the one of HFC-227ea was led simultaneously, and fire extinguishing agents without the secondary damage caused by residuals after the fire extinguishment like a case of the powder fire extinguishing agent, were developed. And experiments using a vehicle collision after the discharge is complete, foreign material can be removed without extinguishing the advantage that experimental results obtained.

Smoke Hazard Assessment of Cypress Wood Coated with Boron/Silicon Sol Compounds (붕소/실리콘 졸 화합물로 도포된 편백 목재의 연기유해성 평가)

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.1-10
    • /
    • 2020
  • In this study, boron/silicon sol compounds were applied to wood for construction and durable materials, and fire risks were investigated in terms of smoke performance index (SPI), smoke growth index (SGI), and smoke intensity (SI). The compound was synthesized by reacting tetraethoxyorthosilicate with boric acid and boronic acid derivatives. Smoke characteristics were investigated using a cone calorimeter (ISO 5660-1) equipment for cypress wood. The fire intensity fixed the external heat flux at 50 kW/㎡. The smoke performance index measured after the combustion reaction increased between 13.4% and 126.7% compared with cypress wood. The fire risk due to the smoke performance index decreased in the order of cypress, phenylboronic acid/silicon sol (PBA/Si), (2-methylpropyl) boronic acid/silicon sol (IBBA/Si), boric acid/silicon sol (BA/Si). The smoke growth index decreased between 12.0% and 57.5% compared to the base specimen. The risk of fire caused by the smoke growth index decreased in the order of cypress, PBA/Si, IBBA/Si, BA/Si. The fire risk due to smoke intensity decreased between 3.2% and 57.8%, and in the order of cypress, PBA/Si, IBBA/Si, BA/Si. COpeak concentrations ranged between 85 and 93 ppm, and decreased between 37% and 43% compared to the base specimen. A comprehensive assessment of the fire risk on smoke hazards decreased in the order of cypress, PBA/Si, IBBA/Si, BA/Si.

Classification of Fire Causes in Warehouses Using the TRIZ Technique and Analysis of Preventive Measures Accordingto 4M (TRIZ기법에 의한 물류창고의 화재원인 및 4M에 따른 예방대책 분석)

  • Han, Sang-Hun;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.401-412
    • /
    • 2020
  • This study analyzed the causes of warehouse fires using a creative problem-solving technique called TRIZ. It identified preventive measures by applying 4M. The results are as follows. First, this study examined the inconsistency among the causes of warehouse fires using TRIZ. Second, it analyzed human factors and fire prevention measures in warehouses such as safety standards for managers, and methods for the promotion of safety consciousness among workers, and for the reinforcement of construction technology for sandwich panel workers. Third, it identified the mechanical and facility factors and fire prevention measures in warehouses such as safety facilities, the expanded installation of safety devices, the adoption and development of fire suppression equipment, and the deployment of methods to improve the fire resistance of sandwich panels. Fourth, it presented working and environmental factors and fire prevention measures in warehouses such as the tightening of safety precautions and the supervision of working methods, and setting fire partitions both in loading places and based on performance-based design. Finally, it proposed managerial factors and fire prevention measures in warehouses such as specific targeting for firefighting with low fire hazards, reviewing the material quality regulations of non-combustible or higher for sandwich panels in the specific target of firefighting that cannot apply fire safety standards, installing sprinklers in cold storage, and mandating the installation of automated facilities with retroactive application regardless of the floor area in the warehouse with a sandwich panel structure.

A Study on Role Assignment between the Ministries of Government for the Research and Development on Disaster Prevention (방재 연구개발 분야의 정부 부처간 역할 조정에 관한 연구)

  • Park, Jung-Han;Choi, Gyu-Hyun;Kim, Young-Soo;Jung, Seong-Hoon;Lee, Sang-Houck;Lee, Pyeong-Koo;Lee, Woan-Kyu
    • Economic and Environmental Geology
    • /
    • v.41 no.3
    • /
    • pp.359-372
    • /
    • 2008
  • A number of researches on disaster risk reduction using the most advanced equipments and scientific technologies have been performed to minimize the damage of property and to protect human life. Although the Korean government is trying to enlarge the research area for disaster risk reduction, the investment size and the applicable results in this area have stayed in the lower level comparing to other scientific fields in Korea and the same field in advanced countries. However, the National Emergency Management Agency (NEMA), a government Agency which is responsible for disaster management coordination, was established in June 2004 establishing an efficient and well-organized system to cope with various disasters. In this study, investment size by the government was evaluated and associated areas were also identified. We also analyzed the roles on research and development for disaster risk reduction among different government Ministries were analyzed and role assignment to each Ministry was proposed. The role assignment has been concreted by conducting the process of approval in the government.

A Preliminary Study on the Fire Safety Testing Method for Fire-resistance Paints Using an X-ray Analysis Method (X-선 분석법을 이용한 내화도료의 화재안전성 평가 방법에 관한 기초연구)

  • Shim, Ji-Hun;Cho, Nam-Wook;Kim, Kang-Woo
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.58-63
    • /
    • 2014
  • Fire-resistance paints are supposed to become intumescent and diminish heat transfer along the steel frames in case of a fire. If unsatisfactory fire-resistance paints which do not satisfy their standard specification are used, it may result in a severe disaster. Because satisfactory fire-resistance paints are hardly discriminated from the unsatisfactory ones by a simple visual inspection, more reliable and convenient onsite evaluation methods are necessary. Here we report the preliminary study result on the fire safety testing method for fire-resistance paints using an X-ray analysis method. It was found that the existence and quantity of effective constituents in fire-resistance paints can be detected by the X-ray analysis method. X-ray fluorescence (XRF) analyses showed that P and Cl elements are much more enriched in fire-resistance paints, compared to normal paints. X-ray diffraction (XRD) analyses showed that ammonium polyphosphate is present as the main crystalline material in fire-resistance paints, but absent in normal paints. The X-ray analysis method is expected to be used for the onsite inspection of fire-resistance paints with the upcoming availability of portable XRF and XRD instruments.