• Title/Summary/Keyword: 소결

Search Result 3,793, Processing Time 0.039 seconds

Rheological and Debinding Properties of Al2O3/Paraffin Wax/High Density Polyethylen System Mixture by Injection Molding (사출성형에 의한 Al2O3/Paraffin Wax/High Density Polyethylen계 혼합물의 유동성 및 탈지 특성)

  • 김승겸;신대용;한상목;강위수
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.5
    • /
    • pp.395-400
    • /
    • 2004
  • The effects of compositions of binders on the rheological properties of mixtures and the preparation conditions on the formation of defects and the debinding characteristics of compacts for the injection molding of ceramic powders (65 wt% aluminaㆍ35 wt% feldspar) were studied. Ceramic powders were coated with 2 wt% of stearic acid and then mixed with 15, 20, and 25 wt% of Paraffin Wax (PW) and High Density Polyethylene (HDPE) as binders at $160^{\circ}C$ for 2 h. Rheological properties were investigated by using capillary rheometer. Apparent viscosities of mixtures were 80∼300 Paㆍs at 1,000$s^{-1}$ of a shear rate, it was good for the injection molding and depending on the compositions of binders. Short shot was formed at 15H5P5 (the ratio of HDPE : PW=5 : 5 in 15 wt% of binders) compacts without injection pressures and any noticeable defects were not formed at 45 kgf/$cm^{2}$ in 20H5P5 compacts. PW and HDPE were removed by the solvent extraction and thermal debinding method. Thermal debinding of HDPE at $450^{\circ}C$ for 5 h, which followed the extraction of PW was using n-heptane solvent at $70^{\circ}C$ for 5 h. Continuous pores in compacts, which facilitate the removal of HDPE by the thermal debinding, were found to form in the compacts when PW was removed by the solvent extraction. The optimum composition of binder at which binder was removed by thermal debinding without defects while maintaining the compact strength was 20H5P5. Bulk density, porosity and 3-point bending strength of 20H5P5 compact sintered at 1,30$0^{\circ}C$ for 5 h were 2.8, < 3%, and 2,400 kgf/$cm^{2}$, respectively, and can be used as a structural materials.

The effect of repeated firings on the color of zirconia-based all-ceramic system (반복 소성이 지르코니아 전부도재관의 색조에 미치는 영향)

  • Jang, Jung-Eun;Kim, Mu-Hyon;Yun, Mi-Jung;Jeong, Chang-Mo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.73-79
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the effect of repeated firings on the color of zirconia restoration with different shading method. Materials and methods: Three different types of zirconia frameworks (adding metallic pigments to the initial zirconia powder before sintering (Group NM), dipping the milled frameworks in dissolved coloring agents (Group KI), or application of liner material to the sintered white frameworks (Group KW) were used to support A3 shade dentin porcelain. Repeated firings (3, 5, or 7) were performed, color differences among ceramic specimens were measured using a colorimeter. Repeated measurements analysis of variance (ANOVA) was used to analyze the data for significant difference. The Tukey Honestly Significant Different (HSD) test was used to perform multiple comparisons (${\alpha}$ = .05). Results: 1. $L^*a^*b^*$ values of the ceramic systems were affected by the number of firings (1, 3, 5 or 7 firings) (P < .001) and shading methods (P < .001). 2. As the number of firings increased, the $L^*$ (for all groups) and $a^*$ value (for KW and NM groups) decreased and the $b^*$ value(for all groups) increased. 3. The mean color differences caused by repeated firings were perceptible (${\Delta}E$ > 1) for group KW and KI fired after 3 times, except for group NM fired after 7 times. 4. In order of decreasing ${\Delta}E$ value fired after 7 times, the values were group KI(${\Delta}E$ = 2.26) > group KW (${\Delta}E$ = 1.47) > group NM (${\Delta}E$ = 1.08) (P < .001). Conclusion: Repeated firings influenced the color of the zirconium-oxide all-ceramic specimens with different shading methods.

Growth and Physiological Characteristics of Five Common Foliage Plant Species Grown under the Influence of Static Magnetic Field (정자기장 처리에 따른 실내 관엽식물의 생육 및 생리적 특성 변화)

  • Lee, Seong Han;Woo, Su Young;Kwak, Myung Ja
    • Horticultural Science & Technology
    • /
    • v.30 no.5
    • /
    • pp.484-492
    • /
    • 2012
  • The present study aimed to investigate the effect of static magnetic field (SMF) on the growth and physiological characteristics of common indoor plant species. Five foliage plant species, Spathiphyllum spp., Ardisia pusilla DC., Syngonium podophyllum, Peperomia pereskiifolia, and Pilea cadierei were potted into plastic pot equipped with round type anisotropic sintered NdFeB permanent magnet inside the pot. The surface magnetic flux density of each magnet was 3,500 G. After 6 months of growth period, the biomass accumulations of Spathiphyllum, A. pusilla, and P. cadierei under SMF were statistically higher than those of controls. Tissue water content also increased under the influence of SMF in most species. The photosynthetic rate of Spathiphyllum under SMF significantly increased but other species showed no significant difference compared with control. Although there was no significant increase in the photosynthetic rates of A. pusilla, and P. cadierei, they showed remarkable increase in total fresh weight under SMF. This suggests that the demand of assimilates for normal metabolism could be decreased under magnetic influence and thereby biomass accumulation could be more favored. But this is not always true for all plant species because P. pereskiifolia in this experiment, showed no changes in both photosynthetic rate and biomass accumulation. Leaf nitrogen and chlorophyll contents were enhanced significantly in most plant species under influence of SMF. Chlorophyll a/b ratio also increased by SMF. Although there might be a limitation depending on plant species, these results suggest that long-term exposure to SMF might allow plant to have an enhanced acclimation capacity against environmental fluctuations and optimal application of SMF could increase the practical use of indoor plants such as an attempt to improve indoor air quality.

The Cosmetic Operation without Healing Purpose - A comparative insight into the ruling of BSG and BGH - (미용성형의료 - 우리 판결례와 독일 판결례의 비교·분석적 소고 -)

  • Ahn, Bup-Young
    • The Korean Society of Law and Medicine
    • /
    • v.16 no.1
    • /
    • pp.3-82
    • /
    • 2015
  • This paper is concerned in the theme of the liability for the breach of duty to inform(Haftungszurechnung der $Aufkl{\ddot{a}}rungspflichtverletzung$) and the malpractice of cosmetic surgery. Here, the terms, treatments for healing purposes and purely medical-technical cosmetic operations are well integrated in the category of "medical conduct(medizinische Handlung)" within the meaning of the public and administrative 'Medical Law'. In the judgment of 6. 13. 2013 Az. 2012DA94865 provides the KHGH(Korean Highest Court of Justice) to inform the patient about the prospects and risks of cosmetic surgery(Infrabrow Excision Blepharoplasty) stringent requirements, similar to the judicature of BGH(cf. BGH, Urt. v. 6. 11. 1990, Az.: VI ZR 8/90). Even in the judgment of 5. 12. 2014 Az. 2013GASO865646 the SZLG(Seoul Central Regional Court) recognizes the physician contract for 'cosmetic septoplasty' as a sort of contract for work. The medical treatment(${\ddot{a}}rztliche$ Heilbehandlung) is still regarded as a prototype of the medical activity, therefore in the meaning of the 'Civil Law(KBGB)', its term needs to be used immediately for healing purposes. The cosmetic operation, desired by a patient, differs from the healing treatment by the element of "indication" and the fact that the "healing purpose(Heilzweck)" itself is missing. In comparative context - methodically fully aware that the unreflective term transfer between different laws might contradict their legal purposes - a series of judgments BSG(BSGE 63, 83, BSGE 72, 96, BSGE, 82, 158, BSGE 93, 252 etc.) and some judgments of LSG are reviewed. In addition, also the dogmatic topic for the "legal natur of a medical treatment contract" is to reconsider by comparative introducing BGHZ 63, 306. Now in view of the current state of greater popularity of artificial cosmetic surgery still indeed is the sentences: The doctor is minister naturae, a helper of nature. A doctor promises regularly only the proper treatment of the patient, but the contractual liability for work should not be excluded in medical conditions for cosmetic surgeries altogether. "With cosmetic operations, seeking to eliminate the external deformities, the doctor may miss the medical profession entirely." - A. Laufs, Medical Law, 5th ed. P. 18.

  • PDF

Clinical Features of Dietary Protein Induced Proctocolitis (식이 단백 유발 직결장염의 임상적 고찰)

  • Im, Sun Ju;Kim, Seong Heon;Bae, Sang Nam;Park, Jae Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.8 no.2
    • /
    • pp.157-163
    • /
    • 2005
  • Purpose: Dietary protein induced proctocolitis (DPIPC) can be considered as a cause of rectal bleeding or blood streaked stool in otherwise healthy-looking infants in the first several months of life. Failure to appreciate this entity may lead to inappropriate diagnostic or therapeutic intervention. This study aimed to ascertain the clinical features, treatment and prognosis of DPIPC. Methods: We reviewed 13 infants retrospectively, presented with bloody stool in early infancy. They were diagnosed as DPIPC clinically in Pusan National University Hospital from May 2002 to June 2004. Results: Seven males and six females were included. The mean age at onset of bleeding was $96.8{\pm}58.8days$. The mean frequency of hematochezia was $2.6{\pm}2.5$ times a day. Duration from onset of symptom to diagnosis was $35.5{\pm}55.0days$ and duration from onset of symptom to resolution of bleeding was $58.7{\pm}67.0days$. Nine (69.2%) were exclusively breast-fed infants and two (15.4%) were formula-fed infants. All but one infant did not have family history of other allergic diseases. A dietary history of ingestion of cow's milk, nut or shellfish was present in three mothers. Peripheral eosinophil count was normal to slightly elevated (total WBC count $10,555{\pm}3,145/mm^3$, relative eosinophil count $6.3{\pm}3.0%$, absolute eosinophil count $659.0{\pm}532.2/mm^3$). Sigmoidoscopy revealed lymphonodular hyperplasia with surrounding hemorrhagic spots in the rectosigmoid colon in 6 infants. Histopathologic finding of colonic biopsies in 5 infants showed chronic inflammation with lymphoid follicular hyperplasia (5 infants), crypt abscess (3 infants), or mild infiltration of eosinophils (less than 20/high power field) in the lamina propria. Spontaneous resolution of rectal bleeding occurred in all infants without dietary change or medicine. Conclusion: Most infants with DPIPC experience a very benign course and have spontaneous resolution of rectal bleeding without changes in the mother's diet. In the case of strong evidence for DPIPC we suggest deferring further invasive investigation and continuing breast feeding.

  • PDF

Production and evaluation of raw materials for porcelain using clay mineral (점토 광물을 이용한 도자기용 소지 제조 및 물성 평가)

  • Kim, Jong-Young
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.6
    • /
    • pp.317-328
    • /
    • 2019
  • In this work, we investigated clay and raw materials from China (black clay, red clay, white clay) and Korea (Cheonan clay, Obu clay) used for the manufacture of porcelain products. According to chemical analysis results, feldspar components containing CaO, K2O, Na2O and quartz are found in clay materials besides primary clay such as kaollinte, for the clay materials from Korea, which is found more in clay materials from Korea than from China. For the Fe2O3 content, governing whiteness of porcelain products, more iron oxide (> 5 %) is found in Korean clays (Cheonan clay, obu clay, red clay) compared to those form China (black, white clay). Through X-ray diffraction analysis, kaolinite and Halloysite are found to be main phases for all the raw materials and second phases such as quartz and pyrophyllite are found. Using these clay materials, raw materials for porcelain products were produced, and the physicochemical properties were investigated for sintered samples. Absorption rate is in order of Baekja-A < Baekja-B < Yeonbuncheong < Jinbuncheong < Cheongja, and the sample, sintered at 1250℃ in reductive atmosphere, exhibits the lowest absorption rate. Comparing the color of the sintered samples, the samples sintered in oxidative atmosphere (L* value: 86~95 %) show higher whiteness value than those sintered in reductive atmosphere (L* value: 81~93 %). For the Cheongja and Buncheong, the samples sintered in reductive atmosphre shows higher whiteness, L* values, and low a*/b* value, which is due to reduction of iron oxide (Fe2O3).

Shear bond strength of veneer ceramic and colored zirconia by using aqueous metal chloride solutions (염화수화물용액 침지법으로 제작한 유색 지르코니아와 전장도재의 전단결합강도)

  • Yun, Kwi-Dug;Ryu, Su-Kyoung;Vang, Mong-Sook;Yang, Hong-So;Kim, Hyun-Seung;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.151-157
    • /
    • 2010
  • Purpose: The purposes of this study was to evaluates shear bond strength between zirconia core and veneer-ceramic in order to examine the clinical practice of colored zirconia block fabricated by infiltration method into the metal chloride solution. Material and methods: CNU block and $Everest{(R)}$ ZS blank were used. VITA In-$Ceram{(R)}$2000 YZ Coloring liquid (LL1) and 3 aqueous metal chloride solutions containing chromium and molybdenum ingredients were used. 40 zirconia specimens were prepared into cuboid shape ($5{\times}5{\times}10 mm$). All specimens were divided into 5 groups by infiltrating into the coloring liquids. After that, porcelain was build up into the shape of $5{\times}5{\times}4mm^3$, followed by sintering. The maximum loading and shear bond strength was measured. Failure patterns and failure sites were examined. Results: 1. There were no statistical differences in shear bond strength between zirconia blocks (P > .05). 2. There were no statistically significant differences in shear bond strength between non-colored and colored zirconia blocks, while shear bond strength of non-colored zirconia blocks is higher than that of colored specimen (P > .05). 3. In the comparison with shear bond strength among colored zirconia blocks, there were no statistical differences according to kinds of coloring liquid (P > .05). 4. Mixed failure patterns were mainly observed in the failure between zirconia and veneering ceramic. The veneering ceramic failure of all specimens was observed in either interface of zirconia or veneering ceramic. Conclusion: Shear bond strength between colored zirconia and veneering ceramic shows lower tendency than non-colored zirconia, but there was clinically allowable value.

Preparation and Properties of the X-ray Storage Phosphors BaFBr1-xIx:Eu2+, Na+ (X-선 저장 BaFBr1-xIx:Eu2+, Na+ 형광체의 제조 및 특성)

  • Cheon, Jong-Kyu;Kim, Sung-Hwan;Kim, Chan-Jung;Kim, Wan;Kang, Hee-Dong;Kim, Do-Sung;Seo, Hyo-Jin;Doh, Sih-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 2002
  • The forming conditions of X-ray storage phosrhors $BaFBr_{1-x}I_x:Eu^{2+}$, $Na^+$ have been investigated, and measured the PSL emission spectra and its intensity, fading characteristics and does dependence of the prepared phosphors. These characteristics were compared with those of commercial image plate (ST-III) obtained from Fuji Photo Film Co. The optimal preparing conditions of $BaFBr_{1-x}I_x:Eu^{2+}$, $Na^+$ Phosphor were 0.5 mol% of $EuF_3$, 4.0 mol% of NaF and composition ratio x=0.3, and the sintering temperature were $950^{\circ}C$ in $H_2$ atmosphere. When the composition ratio x was equal to 0, the spectral range of the luminescence of $BaFBr_{1-x}I_x:Eu^{2+}$, $Na^+$ phosphor was $365{\sim}420\;nm$, and its maximum luminescence intensity appeared at 390 nm. When composition ratio x was not equal to 0, the wavelength ranges and peak of the spectra were shifted to the longer wavelength with the growth of composition ratio x. A good linearity was shown between the PSL intensity and X-ray irradiation dose. The phosphor sample with x=0.3 exhibited better fading characteristics than that of other $BaFBr_{1-x}I_x:Eu^{2+}$ phosphor samples, and the fading characteristics of the PSL intensity at room temperature were shown poorer with increasing $I^-$ ion concentration. The lattice constant of the phosphor becomes larger with increasing the $I^-$ ion concentration.

Preparation and Oxygen Permeation Properties of La0.07Sr0.3Co0.2Fe0.8O3-δ Membrane (La0.07Sr0.3Co0.2Fe0.8O3-δ 분리막의 제조 및 산소투과 특성)

  • Park, Jung Hoon;Kim, Jong Pyo;Baek, Il Hyun
    • Applied Chemistry for Engineering
    • /
    • v.19 no.5
    • /
    • pp.477-483
    • /
    • 2008
  • $La_{0.7}Sr_{0.3}Co_{0.2}Fe_{0.8}O_{3-{\delta}$ oxide was synthesized by a citrate method and a typical dense membrane of perovskite oxide has been prepared using as-prepared powder by pressing and sintering at $1300^{\circ}C$. Precursor of $La_{0.7}Sr_{0.3}Co_{0.2}Fe_{0.8}O_{3-{\delta}$ prepared by citrate method was investigated by TGA and XRD. Metal-citrate complex in precursor was decomposed into perovskite oxide in the temperature range of $260{\sim}410^{\circ}C$ but XRD results showed $SrCO_3$ existed as impurity at less than $900^{\circ}C$. Electrical conductivity of membrane increased with increasing temperature but then decreased over $700^{\circ}C$ in air atmosphere ($Po_2=0.2atm$) and $600^{\circ}C$ in He atmosphere ($Po_2=0.01atm$) respectively due to oxygen loss from the crystal lattice. The oxygen permeation flux increased with increasing temperature and maximum oxygen permeation flux of $La_{0.7}Sr_{0.3}Co_{0.2}Fe_{0.8}O_{3-{\delta}$ membrane with 1.6 mm thickness was about $0.31cm^3/cm^2{\cdot}min$ at $950^{\circ}C$. The activation energy for oxygen permeation was 88.4 kJ/mol in the temperature range of $750{\sim}950^{\circ}C$. Perovskite structure of membrane was not changed after permeation test of 40 h and the membrane was stable without secondary phase change with 0.3 mol Sr addition.

EFFECT OF HYDROGEN PEROXIDE CONCENTRATION ON THE WHITENING AND PHYSICAL PROPERTIES OF HYDROXYAPATITE DISCS (Hydrogen Peroxide 농도와 적용시간이 Hydroxyapatite Discs의 미백과 물리적 성질에 미치는 영향)

  • Yang, Yeon-Mi;Lee, Doo-Cheol;Baik, Byeong-Ju;Kim, Jae-Gon;Shin, Jeong-Geun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.1-12
    • /
    • 2007
  • The purpose of this study was to evaluate the effect that various concentration and application time of hydrogen peroxide had on tooth whitening and physical properties. The hydroxyapatite (HA) discs of $12mm({\Phi}){\times}1.2mm(t)$ in dimensions were made by compression $(100kg/cm^2)$ and sintering (at $1350^{\circ}C$ for 2 hours) All specimens were polished sequentially with '240 through '2000 emery paper and one side of each specimen was polished finally with $0.3{\mu}m$ alumina paste. The discs were placed in sterile whole stimulated saliva overnight at $37^{\circ}C$ in order to form an in vitro pellicle layer. Then the discs were rinsed with distilled water and soaked into staining broth at $37^{\circ}C$ for 7 days. These stained specimens were bleached with hydrogen peroxide according to the change of concentration $(3{\sim}30%)$ and application time ($3{\sim}10$ days). The specimens were analyzed with a spectrophotometer, X-ray diffractometer (XRD), scanning electron microscope (SEM), surface roughness tester, microhardness tester and biaxial flexural strength. The results of present study can be summarized as follows : 1. The bleaching effect was increased with the increased concentration and the extended application time of hydrogen peroxide. 2. The surface roughness was significantly increased from the specimen bleached with 15% hydrogen peroxide for 10 days and with 30% for 7 and 10 days respectively (p<0.05). 3. The changes of crystal phase observed by XRD between before and after bleaching weren't shown of any difference, but microporous structure of surface observed by SEM was shown of increase with the increased concentration and the extended application. 4. The biaxial flexural strength was significantly decreased from bleaching of specimen with 30% hydrogen peroxide for 7 and 10 days respectively (p<0.05) 5. Microhardness was significantly decreased from bleaching with 15% hydrogen peroxide for 10 days and with 30% for 3, 7 and 10 days respectively (p<0.05). Although the tooth bleaching effect was greater when the high concentration was applied, further in vivo experiment will be needed to prove it's safety.

  • PDF