• Title/Summary/Keyword: 센서 어레이

Search Result 234, Processing Time 0.027 seconds

Time-Division Multiplexing(TDM) of Michelson type Fiber-optic Interferometric Sensor Arrays (Michelson 간섭계형 광섬유 간섭센서 어레이)

  • 양진성;김명욱;이상배;조재철;최상삼
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.125-129
    • /
    • 1990
  • One method for time-division multiplexing (TDM) of Michelson type fiber-optic interferometric sensor arrays is proposed and demonstrated experimentally. This method has some advantages; fewer fiber-optic components. low cost. and high reliability.bility.

  • PDF

Optimization of Thinned Sensor Arrays Using A Weighted Leastd Square Method (계수 최소 자승 방법을 사용한 희소어레이의 최적화)

  • 장병건;전창대
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.117-120
    • /
    • 1999
  • 본 논문은 희소어레이의 패턴을 원하는 패턴과 실제 희소어레이의 패턴간의 오차의 계수적 자승치를 최소화하여 최적화하는 방법을 제시한다 센서의 간격이 어레이 중심에 관하여 대칭인 경우와 비대칭인 경우에 대하여 성능을 점검하며, 어레이 공간의 주어진 영역의 오차함수에 성능 향상을 위하여 계수를 적용한다. 주빔 부근의 측면롭의 효과적인 제어를 위하여 지수 함수적인 계수를 제안하였으며 그 결과 측면롭의 수준이 전체적으로 균등하게 분포되는 패턴을 얻을 수 있었다. 이 결과는 입력잡음신호가 어레이 공간상에 균등하게 입사될 때 효과적으로 사용될 수 있다.

  • PDF

금 나노로드 어레이 박막을 이용한 광학형 바이오 센서 개발

  • Yeom, Se-Hyeok;Lee, Dong-Ik;Sin, Han-Jae;Seo, Chang-Taek
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.436-436
    • /
    • 2014
  • 본 연구에서는 전 세계적으로 활발히 연구되고 있는 나노바이오센서 분야 중 가장 주목을 받고 있는 LSPR 원리를 이용한 바이오센서를 제작하였다. 금속 나노입자의 국소 표면 플라즈몬 공명현상에 의한 주위환경에 민감하게 반응하는 특성은 고감도 광학형 바이오센서, 화학물질 검출 센서등에 응용된다. 특히 금 나노막대와 같은 1차 나노구조물은 나노막대의 주변 환경 변화에 따라 뚜렷한 플라즈몬 흡수 밴드 변화를 나타냄으로 센서로 적용 했을 때 고감도의 측정이 가능하다. 본 연구에서는 다공성인 알루미늄 양극산화 박막 주형틀을 이용하여 다양한 종횡비를 가지는 금 나노막대를 합성하고, 나노막대 어레이 형태의 박막을 제작하였다. 금 나노막대의 합성은 알루미늄 양극산화막을 사용한 주형제조 방법(template method)을 사용하는 전기화학 증착법을 사용하였다. 우선 부도체인 알루미늄 양극 산화막의 한쪽면을 열증착 장비를 사용하여 금을 증착하여 작업 전극(working electrode)을 형성하였다. 백금 선(platinum wire)을 보조 전극(counter electrode)으로 사용하고 Ag/AgCl 전극을 기준 전극(reference electrode)으로 사용하여 삼전극계(three-electrode system)를 형성하였으며, 금 도금 용액(orotemp 24 gold plating solution, TECHNIC INC.)을 사용하여, 800 mV 전압에서 금 나노 막대를 합성하였다. 금 나노막대의 길이는 테플론 챔버를 통과한 전하량 또는 전기 증착 시간에 비례하여 결정된다. 금 나노막대를 성장시킨 알루미늄 양극산화막을 실리콘 웨이퍼에 은 페이스트를 사용하여 고정시킨 후 수산화나트륨 (NaOH)용액을 사용하여 알루미늄 양극산화막을 녹여내어 수직방향으로 정렬되어 있는 나노 막대 어레이 박막을 제조 하였다. 또한 제작된 금 나노막대 어레이의 광학적 특성을 평가하였다. 본 연구에서와 같이 나노막대를 직경방향으로 측정할 경우, 직경방향의 transverse mode만 측정된다. 금 나노 막대가 알루미늄 양극산화막 안에 포함된 상태로 측정된 금 나노로드 어레이 박막의 광 스펙트럼 분포는 금 나노막대의 가시광영역에서의 흡수 스펙트럼을 측정하였을시 직경 및 길이에 따라 transverse mode의 ${\lambda}$ max (최대 흡광)의 위치가 변화됨을 나타낸다. 실험 결과를 바탕으로 나노막대의 종횡비가 증가함에 따라 흡수 스펙트럼의 transverse mode ${\lambda}$ max가 미약하게 단파장 영역으로 이동하는 것을 확인할 수 있다. 이러한 결과는 원기둥 형태의 금 나노막대의 흡수 스펙트럼에 대한 이론적인 예측과 부합한다. 바이오센서로의 적용 가능성을 확인하기 위하여 자기조립단분자막을 형성하여 항체를 고정하고 CRP에 대한 응답특성을 평가하였다. CRP 항원-항체의 면역반응에 대한 실험 결과 CRP 항원의 농도가 증가함에 따라 넓은 측정범위에서 선형적으로 흡광도가 증가하는 결과를 나타내었으며, CRP 10 fg/ml의 농도까지 검출할 수 있었다. 센서의 선택성을 확인하기 위하여 감지하고자하는 대상물질이 아닌 Tn T 항원을 감지막에 반응시켜 흡광도 변화를 분석하였다. 결과적으로 제작된 센서칩은 선택성을 가지고 측정하고자하는 물질에만 반응함을 확인하였다. 이러한 결과는 다양한 직경을 사용한 부가적인 LSPR현상의 연구에 활용될 수 있을 것이다.

  • PDF

ADSTM Methodology for Signal Pattern Classification (신호 패턴 분류를 위한 ADSTM 기법)

  • Kim A-Ram;Lee Seung-Jae;Kim Chang-Hwa
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.05a
    • /
    • pp.379-382
    • /
    • 2006
  • 일반적으로 센서 어레이는 많은 채널의 센서를 가지고 있으므로 분석해야 할 데이터의 양이 많다. 따라서 다변량(多變量) 분석 방법을 이용하는데, 크게 통계적 방법과 신경망 방법을 분석하고자 하는 데이터의 특성이나 분석에 필요한 환경 조건에 맞는 분석 방법을 선택하여 이용한다. 센서 어레이의 신호 패턴을 분석하기 위해 본 연구에서는 상태 천이 모델을 이용하여 측정된 가스의 특성을 반영할 수 있는 통계적 방법에 대해 연구하였다. 센서 어레이 신호 데이터를 패턴 모양의 특성을 나타낼 수 있는 상태 천이 모델로 변환하여 가스 종류 식별이 보다 정확하게 이루어 질 수 있도록 모델을 설계하는데 중점을 두고, 모델링 요소인 '상태'는 일정한 시간 간격으로 샘플링 하였을 때의 신호값으로,'천이 관계는 각 천이 벡터의 각으로 각각 정의하여 각도변이 기반 상태천이 모델링을 고안하였다.

  • PDF

Development of Infusion Pump System using Photodiode Array (광 다이오드 어레이 센서를 이용한 인퓨전 펌프 시스템의 개발)

  • Kwon, Jang-Woo;Park, Jung-Sun;Lee, Dong-Hun;Lee, Eung-Huyk;Hong, Seung-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.65-73
    • /
    • 1996
  • One of the important factor in drug stuffs to a patient is to inject exact amount with stable flow rates. Since improper injection amount and flow rates would cause bad effect to recovery of a patient, the detecting sensors with high sensitivity is required for an injection pump systems' performance improvement. In this study, the three sensors, piezo film sensor, photo transistor and photo array, were compared to find best one for an injection pump monitoring system. Using suggested data processing technique and photo array sensors, we could minimize the effect of interference, disturbance, illumination, and sensitivity change caused by sensor's position. According to the experiments, the photo array showed the higher reliance than any other the three types of sensors.

  • PDF

Platform Design for Multiple Sensor Array Signal Verification (다중 센서 어레이 신호 검증을 위한 플랫폼 설계)

  • Park, Jong-Sik;Lee, Seong-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.11
    • /
    • pp.2480-2487
    • /
    • 2011
  • As sensor technology grows up in fields such as environmental hazards detecting system, ubiquitous sensor network, intelligent robot, the sensing and detecting system for sensor is increasing. The sensor data is measured by change of chemical and physical status. Because of decrepit sensor or various sensing environment, it is problem that sensor data is inaccurate result. So the reliability of sensor data is essential. In this paper, we proposes a reliable sensor signal processing platform for various sensor. To improve reliability, we use same sensors in multiple array structure. As sensor data is corrected by spatial and temporal relation signal processing algorithm for measured sensor data, reliability of sensor data can be improved. The exclusive protocol between platform components is designed in order to verify sensor data and sensor state in various environment.

Volatile Organic Gas Recognition Using Conducting Polymer Sensor array (전도성 고분자 센서 어레이를 이용한 휘발성 유기 화합물 가스 인식)

  • Lee, Kyung-Mun;Joo, Byung-Su;Yu, Joon-Boo;Hwang, Ha-Ryong;Lee, Byung-Soo;Lee, Duk-Dong;Byun, Hyung-Gi;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.286-293
    • /
    • 2002
  • We fabricated gas recognition system using conducting polymer sensor array for recognizing and analyzing VOCs(Volatile Organic Compounds) gases. The polypyrrole and polyaniline thin film sensors which were made by chemical polymerization were employed to detect VOCs. The multi-dimensional sensor signals obtained from the sensor array were analyzed using PCA(principal component analysis) technique and RBF(radial basis function) Network. Throughout the experimental trails, we confirmed that RBF Network is effective than PCA technique in identifying VOCs.

A Dissolved Oxygen Measurement System Using FET-type Dissolved Oxygen Sensor Array (FET형 용존산소 센서 어레이 측정시스템)

  • Jeong, H.;Sohn, B.K.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.259-265
    • /
    • 2001
  • FET-type dissolved oxygen sensor has the Pt working electrode around the pH-ISFET. Appling a voltage to the working electrode, the hydrogen ion which is proportional to the dissolved oxygen concentration occurs around the pH sensing gate and we can measure the dissolved oxygen concentration by detecting pH concentration through the pH-ISFET. In this paper, a dissolved oxygen measurement system using FET-type dissolved oxygen sensor array which adopt a specific algorithm to enhance the reliability has been developed and we compared its performance with the commercial dissolved oxygen measurement system.

  • PDF

Increase of Side-lobe Level Difference of Spherical Microphone Array by Implementing MEMS Sensor

  • Lee, Jae-Hyung;Choi, Si-Hong;Choi, Jong-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.816-820
    • /
    • 2011
  • A method for increasing the difference of side-lobe level in spherical microphone array is presented. In array signal processing, it is known that narrow interval between sensors can increase the difference between main lobe and side-lobe of array response which eventually increase the source recognition capability. Recent commercial array being used, however, have shown certain limitation in using the number of sensors due to its costs and geometrical size of array. To overcome this problem, we have adapted MEMS sensors into spherical microphone array. To check out the improvement, two different types of spherical microphone array were designed. One array is composed with 32 regular instrument microphones and the other one is 85 MEMS sensors. Simulation and experiments were conducted on a sinusoidal noise source with two arrays. The time history data were analyzed with spherical harmonic decomposition and beamforming technique. 85 MEMS sensors array showed the improved side-lobe level suppression by more than 4 dB above the frequency content of 2 kHz compared to 32-sensor array.

  • PDF

Performance Analysis of FFTSA Method using Conformal Array (Conformal 어레이를 이용한 FFTSA 기법 성능 분석)

  • Choi Pyoung-Joo;Lee Won-Cheol
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.305-310
    • /
    • 1999
  • 본 논문에서는 기존의 선형 견인 어레이 방법인 FFTSA기법에서의 여러 가지 환경적 요인에 대한 입사각 추정 성능의 변화에 대해서 고찰하여 보았다. 즉, 시간 및 공간적 코히어런스 주기 변화에 대한 추정 성능 변화와 견인 센서 어레이가 가져야 하는 직선 경로에서 주위의 환경적 요인으로 인해 직선 방향을 중심으로 이탈된 발진 경로, 또는 진동경로가 발생되는 시스템 에러주기 변화에 대한 추정 성능의 변화에 대해 컴퓨터 시뮬레이션을 통하여 입사각 추정 성능의 변화를 살펴보았다. 또한 비선형 특성을 지니는 견인 배열 센서 어레이인 Conformal array를 FFTSA기법에 적용했을 경우 환경적 요인에 의한 입사각 추정 성능의 변화를 컴퓨터 시뮬레이션을 통하여 기존의 FFTSA기법과 비교하여 보았다.

  • PDF