• Title/Summary/Keyword: 세침흡인 검사

Search Result 138, Processing Time 0.023 seconds

Usefulness of Color-overlay Pattern of Thyroid Elastic Ultrasonography (갑상선 탄성 초음파 검사 시 칼라 오버레이 패턴의 유용성)

  • Park, Ji-Yeon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.341-346
    • /
    • 2022
  • The color overlay pattern of thyroid shear wave elastography applied in this study distinguishes benign and malignant nodules based on the optimal cut-off value of 74.2 kPa. From august 2021 to september 2021, thyroid ultrasound and elastography were performed on 57 patients with thyroid lesions using an ultrasound device RS85 prestige (Samsung Medison, Korea) and a 2-14 MHz linear transducer. In addition, the results of classification by K-TIRADS for each thyroid nodule and the results of classification by color overlay pattern according to the kPa value of acoustic ultrasound were compared and analyzed. In the color overlay pattern, the results classified as 40 people from dark blue to light blue and 17 people from green to red were similar to the K-TIRADS category results, which were classified as 42 benign and 15 malignant. Between blue and light blue, benign, and between green and red, malignant. If the shear wave elastography method is applied before the fine-needle aspiration cytology of the thyroid nodule is performed, the differential diagnosis of thyroid tissue from benign and malignant can be predicted in advance, and it will help to reduce unnecessary invasive tests.

Efficacy of Fine Needle Aspiration Biopsy in Parotid Gland Tumors (이하선 종양에서 세침흡인검사의 유용성)

  • Lee, Chang-Hee;Lee, Hyun-Sub;Jin, Sung-Min;Lee, Sang-Hyuk;Pyo, Jung-Soo;Sohn, Jin-Hee
    • Korean Journal of Head & Neck Oncology
    • /
    • v.27 no.2
    • /
    • pp.204-209
    • /
    • 2011
  • Background and Objectives : The usefulness of fine needle aspiration biopsy(FNAB) for diagnosis of parotid gland tumors is controversial, because of the generalized belief requiring surgery for most parotid tumors. The aim of this study was to evaluate the efficacy of FNAB for diagnosis in parotid gland tumors. Material and Methods : FNAB was performed in 91 patients who underwent parotid surgery at Kangbuk Samsung Hospital from January 2007 to December 2010. The result of FNAB, 11 malignancies and 75 benign tumors and 5 non-neoplasms were analyzed and compared with the final histopathologic diagnoses. Sensitivity, specificity, accuracy, positive predictive value(PPV), and negative predictive value(NPV) were calculated using final histopathologic diagnosis of the surgical specimen as the standard diagnostic reference for comparative analysis. Results : 86 specimens(94.5%) were suitable for evaluation. We compared the result of FNAB and the final histopathology in 79(89.4%) cases. The sensitivity, specificity, accuracy, PPV, and NPV of FNAB for detecting pleomorphic adenoma was 95.8%, 88.4%, 92.3%, 90.2%, and 95.0%. In Warthin's tumor, results were 86.4%, 94.2%, 92.3%, 82.6%, and 95.6%. Among 11 patients who were diagnosed with malignancy on final histopathologic report, only 3(30%) patients were diagnosed with the same as on FNAB, the other 8 patients were initially diagnosed incorrectly as benign tumors in FNAB. There were no complications related to FNAB. Conclusion : Diagnostic accuracy for FNAB in benign parotid tumors was high. However, in malignant tumors, FNAB shows low diagnostic usefulness compared with benign tumors. FNAB can be effective and safe diagnostic technique for evaluating the benign parotid glands tumors.

A Study of Usefulness of Fine Needle Aspiration Cytology of the Thyroid Lesions (갑상선 병변의 세침흡인 세포검사의 유용성에 관한 연구)

  • Kwon, Kye-Hyun;Jin, So-Young;Lee, Dong-Wha
    • The Korean Journal of Cytopathology
    • /
    • v.7 no.2
    • /
    • pp.111-121
    • /
    • 1996
  • Fine needle aspiration cytology(FNAC) is preferred because of simplicity, safety, and reliability in the evaluation of patients with thyroid nodule or hyperplasia. However, there are a few limitations such as false-negative or false-positive cases and non-diagnostic material. To evaluate the usefulness of FNAC in thyroid lesions, we reviewed 704 FNAC cases of thyroid nodules from 1988 to 1994 at Soonchunhyang University Hospital. The results are as follows. 1. Among 704 FNAC cases of thyroid gland, 571(81.1%) cases were benign, 12(1.7%) were suspicious, 71(10.1%) were malignancy, and 50(7.1%) were material insufficiency. The cytologic diagnoses of the benign lesions included 168 cases of follicular neoplasm, 139 cases of adenomatous goiter, 162 cases of follicular lesion such as follicular neoplasm or adenomatous goiter, 61 cases of Hashimoto's thyroiditis, 13 cases of subacute thyroiditis, and 28 cases of colloidal nodule or benign nodule. The malignant lesions included 68 cases of papillary carcinona, two medullary carcinomas and a case of metastatic colon cancer. 2. The average number of cytologic smear slides was $4.12{\pm}1.81$ in material insufficiency and $5.63{\pm}1.79$ in diagnostic cases. This difference was statistically significant(p<0.00001). 3. Histological assessment of 150 cases revealed 2 false negative and 1 false positive cases. The false negative cases were a case of marked sclerosis in papillary carcinoma and an occult case of papillary carcinoma. The false positive case resulted from pseudo-ground glass nuclei due to marked dry artifact. 4. Comparison between the FNAC and the histologic diagnosis revealed that FNAC had a sensitivity of 93.5%, a specificity of 99.2%, a false negative rate of 6.6%, a false positive rate of 0.8%, and an overall diagnostic accuracy of 98.0%. Therefore, FNAC of thyroid gland is a very reliable diagnostic method with excellent accuracy rate.

  • PDF

Value of Fine Needle Aspiration Cytology of Mucinous Carcinoma of the Breast (유방의 점액성 암종의 진단시 세침흡인 검사의 의의)

  • Kim, Yoon-Jung;Gong, Gyung-Yub;Huh, Joo-Ryung;Park, Jeong-Mi;Ahn, Sei-Hyun;Kim, On-Ja
    • The Korean Journal of Cytopathology
    • /
    • v.7 no.2
    • /
    • pp.157-162
    • /
    • 1996
  • Fine needle aspiration(FNA) is an effective tool in diagnosing mammary carcinoma. We experienced 7 cases of histologically confirmed mammary mucinous carcinoma among 3,052 aspirated cases of breast from 1992 to 1996 in Asan Medical Center. The average age of the patient was 48(33-64) years. The mean size of the lesions was $1.6(0.7{\sim}3)cm$, and they were palpated as well-defined, firm to hard masses. The cytologic features that may be useful in making a FNA diagnosis of mucinous carcinoma of the breast were analysed. Mucinous background and tumor cell clusters with occasional single cells were observed in all cases. Among them, two cases showed abundant scattered single cells, whereas only few single cells were seen in the other two cases. Tumor cells exhibited mild pleomorphism in four cases and moderate pleomorphism in three cases. Nucleoli tended to be not prominent and are observed in three cases, rarely noted in other three cases and not seen in one. There was microcalcification in four cases(57%). In conclusion, mucinous background and clustered tumor cells showing mild to moderate pleomorphism with characteristic clinical findings allow us to diagnose mucinous carcinoma of the breast.

  • PDF

Polymerase Chain Reaction Detection of Mycobacterium tuberculosis and Fine Needle Aspiration Cytology for the Diagnosis of Tuberculous Lymphadenitis (결핵성 림프절염의 진단를 위한 세침흡인 세포검사 및 중합효소연쇄 반응과 효소면역법을 이용한 Mycobacterium tuberculosis의 검출)

  • Kim, Joo-Heon;Kim, Nam-Hoon;Kang, Dong-Wook;Park, Mee-Ja;Moon, Sang-Kyoung;Yu, Tae-Cho;Jang, Eun-Ju
    • The Korean Journal of Cytopathology
    • /
    • v.12 no.1
    • /
    • pp.25-30
    • /
    • 2001
  • Tuberculous lymphadenitis is not uncommon in Korea. Therefore, an inexpensive, safe and rapid method is needed to diagnose the tuberculous lymphadenitis. Flne needle aspiration cytology Is a good method for this purpose, but has several limitations in the diagnosis of tuberculous lymphadenitis, especially when the presence of acid-fast bacilli is not proved. To evaluation the usefulness of the polymerase chain reaction with enzyme immunoassay technique in the detection of Mycobacterium tuberculosis (M. tuberculosis) In the cervical Iymph node asplrates, the authors performed fine needle aspiration cytology and M. tuberculosis PCR with enzyme immunoassay for mycobacterial DNA sequences from 15 cases of the fine needle aspirates. Cytomorphologically, the cases were categorized into three types: predominantly necrotic materials; typical epithelioid cell granulomas with or without slant cells and caseous necrosis; and non-tuberculous lesions, such as reactive lymphadenitis, abscess, metastatic carcinoma and malignant lymphoma. M. tuberculosis DNA was found in 8 of 15 cases by PCR with enzyme immunoassay. Negative findings on PCR were achieved in 7 cases, which revealed non-tuberculous tymphadenopathy. In conclusion, we suggest that M. tuberculosis PCR with enzyme immunoassay using the fine needle aspirates is a very useful tool for the diagnosis of tuberculous lymphadenitis.

  • PDF

Differential Diagnosis of Fine Needle Aspiration Cytology of Benign Lymphadenopathy (양성 림프절 증식의 세침흡인 세포검사의 감별진단)

  • Han, Eun-Mee;Song, Dong-Eun;Eom, Dae-Un;Choi, Hye-Jeong;Cha, Hee-Jeong;Huh, Joor-Yung
    • The Korean Journal of Cytopathology
    • /
    • v.17 no.2
    • /
    • pp.99-107
    • /
    • 2006
  • In the investigation of superficial lymphadenopathy of unknown cause, fine needle aspiration (FNA) cytology plays an invaluable role. It enables the differentiation of benign lymphadenopathy from lymphoid and non-lymphoid malignancies, obviating the need for open biopsy, and allowing the triage of patients. Cytopathologists should be familiar with the typical FNA patterns of benign lymphadenopathy, and recognize and differentiate among categories. In a minority of cases of benign lymphadenopathy, FNA can render a specific diagnosis. Benign lymphadenopathies are generally categorized into reactive lymphoid hyperplasia (RLH), inflammatory or infectious processes, and benign lymphoproliferative disorders. RLH characteristically presents with a heterogeneous and polymorphous smear composed of normal cellular constituents of lymph nodes, in contrast with the homogeneous or monomorphic smear of most lymphomas. The caveat is that various malignant disorders may also present with polymorphous populations. It is also important to recognize thatbenign lymphoid smears may sometimes contain atypical cells that raise the suspicion of malignancy. Clinical information should always be the integral part of the diagnostic criteria in FNA of lymphadenopathy. If there is any doubt about the benign nature of the smear, it is prudent to suggest biopsy and ancillary studies.

Fine Needle Aspipration Cytology of Metastatic Pulmonary Seminoma - A Cese Report - (세침흡인 세포검사로 진단된 폐에 전이한 정상피종 - 1예 보고 -)

  • Jeong, Hwa-Sook;Lee, Geon-Kook;Kim, Wun-Jae;Earm, Jae-Ho;Song, Hyung-Geun
    • The Korean Journal of Cytopathology
    • /
    • v.7 no.1
    • /
    • pp.97-102
    • /
    • 1996
  • Fine needle aspiration cytology of a pulmonary mass was performed on a 51-year-old man who had a left testicular mass. Cytologic features were composed of a homogeneous population of malignant cells associated with a background of foamy and lacelike material. The cellular features were characterized by monomorphous cell proliferation of relatively regular large cells, generally isolated or grouped. Occasionally, fine blanching stroma with large tumor cells and scanty lymphocytes were noted. The tumor cells had a round, regular nucleus, prominent round nucleoli, and a thin rim of cytoplasm containing large vacuoles or lacunae filled with glycogen. The fine needle aspiration cytologic diagnosis was highly consistent with metastatic seminoma from testis and less likely primary or other metastatic carcinoma. The diagnosis of resected testicular mass was classic seminoma. Despite the fact that cytopathologists were not familial with diagnosis of seminoma due to clinician's lack of interest in fine needle aspiration cytology of germ cell tumors including seminoma, it appears that a diagnosis of this tumor should not be problematic in cytologic material if specific histologic criteria are applied.

  • PDF

Well Differentiated Adenosquamous Carcinoma of Lung Mimicking Benign Lesions in Fine Needle Aspiration Cytology - Report of a Case - (세침흡인 세포검사에서 양성 질환을 닮은 폐의 고분화 샘편평 암종 - 1예 보고 -)

  • Bae, Jong-Yup;Oh, Hoon-Kyu;Park, Jae-Bok
    • The Korean Journal of Cytopathology
    • /
    • v.15 no.2
    • /
    • pp.101-105
    • /
    • 2004
  • Fine needle aspiration (FNA) cytological examination is an appropriate method for the evaluation of pulmonary nodules. In major types of lung cancer, Its diagnostic accuracy is quite high. However, it is sometimes difficult, using this technique, to differentiate between some unusual phenotypes including adenosquamous carcinoma, bronchioloalveolar carcinoma (BAC), neuroendocrine tumor, mucoepidermoid carcinoma, and sclerosing hemangioma. Here, we present a case involving extremely well differentiated adenosquamous carcinoma, mimicking benign lesions, such as pulmonary scar and adenomatoid malformation with squamous metaplasia. The patient was a 68-year-old man presenting with a solitary pulmonary nodule$(1.6\times1.6cm)$, which was incidentally found at the periphery of the right lower lobe. FNA revealed some clusters of glandular cells with minimal atypia, in addition to squamous cells at a nearly full maturational state. Histological examination verified the cytological diagnosis on a lobectomy specimen. The tumor exhibited a well differentiated adenocarcinoma component, mimicking the bronchioles in scarred lung tissue. and a well differentiated squamous cell carcinoma component, mimucking the squamous cell nests of adenoacanthoma, in the other organs. In the present case, the possibility of adenosquamous carcinoma should have been considered if squamous cells were seen in the FNA from the peripheral pulmonary nodule, even though they appeared to be benign.

Fine Needle Aspiration Cytology of Kimura's Disease of Parotid Gland - Report of A Case Cytologically Failed to Diagnose as Kimura's Disease - (귀밑샘의 기무라병의 세침흡인 세포학적 소견 -세포학적 검사로 예측할 수 없었던 1예 보고-)

  • Kim, Se-Hoon;Kim, Hae-Ryoung;Kim, Sung-Eun;Yang, Woo-Ick;Lee, Kwang-Gil;Hong, Soon-Won
    • The Korean Journal of Cytopathology
    • /
    • v.14 no.2
    • /
    • pp.86-90
    • /
    • 2003
  • Kimura's disease is a chronic inflammatory disorder of unknown cause and is most prevalent among Asians. The cytologic findings of Kimura's disease are significant numbers of eosinophils in a background of lymphoid cells, occasional fragments of collagenous tissue, proliferation oi vessels, and Warthin-Finkeldey polykaryocytes. Among these features, the most important cytologic feature of Kimura's disease is a significant numbers of eosinophils. We experienced a case of Kimura's disease in the parotid gland which we fatted to recognize on cytology due to the apparent paucity of eosinophils. On careful retrograde reviewing of the cytologic findings, a few scattered leukocytes, previously interpreted as polymorphous leukocytes, had bilobed nuclei and coarse green but granular cytoplasm on Papanicolaou preparation. These leukocytes showed obvious orange-red intracyloplasmic granules as in eosionophils on Giemsa stain. The paucity of eosinophils may be due to the thick fibrosis around lymphoid follicles or any technical error during aspiration. Whereas the Warthin-Finkeldey type giant cell is not a sensitive cytologic marker of Kimura's disease, it may be a helpful cytologic feature. To reach a correct cytologic diagnosis of Kimura's disease, It is important to keep in mind that searching for Warthin-Finkeldey type giant cells and evaluation of Giemsa stain for detection of eosinophils would be helpful.

Diagnostic Usefulness and Limitation of Fine Needle Aspiration Cytology of Lymph Node - Analysis of 176 Cases Confirmed by Biopsy - (림프절 세침흡인 세포검사의 진단적 유용성과 한계 - 생검으로 확진한 176 예의 분석 -)

  • Kim, Hee-Sung;Kim, Dae-Soo;Oh, Young-Lyun;Ko, Young-Hyeh;Ree, Howe-J.
    • The Korean Journal of Cytopathology
    • /
    • v.10 no.1
    • /
    • pp.35-42
    • /
    • 1999
  • The accuracy of fine needle aspiration cytology(FNAC) of the lymph node was investigated through a review of 176 FNAC cases and the corresponding biopsies. We chose 157 FNAC cases after the exclusion of 19 inadequate ones. Sensitivity of malignancy was 94.0%, specificity 100%, false negativity 6.0%, and false positivity 0.0%. The overall diagnostic accuracy was 96.8%. Sensitivity of metastatic carcinoma was 98.0% and that of malignant lymphoma was 87.9%. False negative cases included one metastatic carcinoma and four malignant lymphomas. The aspirates of metastatic carcinoma with false negativity exhibited a diffuse smear of keratin debris without viable cells, which led to the difficulty in differentiation from benign epithelial cyst. The cases of malignant lymphoma with false negative diagnosis were two Hodgkin diseases, one Lennert's lymphoma, and one peripheral T cell lymphoma in the histologic sections. On the analysis of 39 cases of tuberculosis, 17 cases(43.6%) were diagnosed as tuberculosis, 4(10.3%) as granulomatous lymphadenitis, 3(7.7%) as necrotizing lymphadenitis, and 15(38.5%) as reactive hyperplasia or pyogenic inflammation. Sensitivity of tuberculosis was 53.9%. In conclusion, lymph node FNAC is an excellent non-invasive diagnostic tool for the diagnosis of metastatic carcinoma. The diagnostic accuracy of malignant lymphoma could be improved with flow cytometry or polymerase chain reaction for antigen receptor genes. For the FNAC diagnosis of tuberculosis, AFB stain, culture, and PCR would be helpful as adjuvant techniques.

  • PDF