• Title/Summary/Keyword: 세정수

Search Result 676, Processing Time 0.029 seconds

Analysis of a Comparability Test between LX Detergent Cleaning Solution and OC Detergent Cleaning Solution Using OC Sensor PLEDIA (OC Sensor PLEDIA를 이용한 LX Detergent Cleaning Solution과 OC Detergent Cleaning Solution의 동등성 평가)

  • Cha, Kyung Jae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.1
    • /
    • pp.19-31
    • /
    • 2021
  • This study aimed at comparing the performance of imported LX detergent cleaning solution (LX-CS) and the self-manufactured OC cleaning solution (OC-CS), based on functional and quantitative analysis. The functional analysis was carried out using apparent diffusion coefficient (ADC) values. For quantitative analysis, precision, linearity, and carry-over rates were measured with commercial control materials according to the Clinical and Laboratory Standards Institute (CLSI) guidelines. Using OC-Sensor PLEDIA (Eiken Chemical, Japan), the ADC value of all cuvettes satisfied the acceptance criteria. For quantitative analysis, precision was less than 5.0% for the two products, and carry-over rates were less than ±1.00%. The linearity slopes and r2 values were 1.0017 and 0.9982 in the LX-CS, and 0.9924 and 0.9996 in the OC-CS, respectively. The correlation coefficient (r) was found to be 0.9997. Also, the percent difference in correlation with 40 artificial-stool specimens was less than 10% and the p-value was less than 0.1. The result of standard deviation ratio (D: ±1 SD ratio) was similar for both products. In conclusion, the functional and quantitative analyses of the two products were compared and showed similar results. In the future, the self-manufactured OC-CS will be able to provide a much more stable and faster supply than the imported LX-CS.

Development of Chemical Cleaning Agents for Cleaning Indoor Water Supply Pipes (옥내급수관 세척용 화학세정제 개발 연구)

  • Lee, Jae-Hoon;Jung, Jae-Yong;Park, Yong-Bae;Bae, Jae-Heum;Woo, Dal-Sik;Sin, Hyun-Duk
    • Clean Technology
    • /
    • v.16 no.3
    • /
    • pp.162-171
    • /
    • 2010
  • The objective of this study is to develop cleaning agents for the indoor water supply pipe which is environmentally friendly and suitable for removing scale by using various organic acids, inorganic acids, and some additives. Among various organic acids, oxalic acid, citric acid, and malic acid showed good cleaning efficiency of iron oxides which were main components of the indoor water supply pipe scale. Several cleaning agents were formulated by adding chemical additives into these organic acids and evaluated for removal of iron oxides. In this study, it was found that nonionic surfactants were excellent for the removal of iron oxide scale among various additives. Two types of cleaning agents($F_1$, $F_2$) with comparatively high solvent power for iron oxides were formulated in this study. The cleaning agents $F_1$ made by organic acids and some additives were formulated to be safe and environmentally friendly, but seemed to have disadvantage due to their comparatively low cleaning efficiency of iron oxide than $F_2$. But, the cleaning agents $F_2$ prepared by adding inorganic acid a little to $F_1$ showed comparatively good cleaning efficiency of iron oxide and could be recommended for removing hard scale of iron oxides in the indoor water supply pipe. Thus, it is considered that the formulated cleaning agents should be selected based on the extent of scale in the indoor water supply pipe.

GaN 위에 electron beam evaporator로 증착시킨 ITO contactd의 구조적 특성 및 전기적 특성 평가

  • 김동우;성연준;이재원;박용조;김태일;김현수;염근영
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.33-33
    • /
    • 2000
  • 일반적으로 GaN-based light emitting diodes(LEDs)는 Top layer위에 금속박막으로 contact을 형성하고 있으며 광소자 구성에 있어 빛은 이러한 금속 contact을 통과할 수 없다. 그러나 만약 이러한 contact이 투명전도막으로 구성될 수 있다면 보다 효율적인 광소자의 구성이 기대되어진다. 특히 GaN photodetector, GaN-based LEDs, GaN vertical cavity surface emitting lasers(VCSELs)등의 소자형성에 있어 투명전도막 contact은 매우 중요하며 그 응용에 앞서 기본적인 구조적, 전기적, 광학적 특성에 대한 연구가 반드시 선행되어져야 한다. 따라서 본 실험에서는 이러한 투명전도막으로써 Indium Tin Oxide(ITO)를 사용하였으며 박막형태의 contact으로 제조하여 n-GaN, p-GaN와 corning glass위에 e-beam evaporation법로써 제조하였다. 또한 각 n-, p-type과 corning glass위에 증착된 ITO박막의 구조적 특성을 분석하기 위하여 x-ray diffractometry(XRD)와 Auger electron spectroscopy(AES)등을 사용하였으며 전기적 특성을 측정하기 위하여 four point probe를 사용하였고 그들의 I-V 곡선을 측정하였다. 또한 UV spectrometry를 사용하여 그들의 광학적 특성을 측정하고자 하였다. ITO 박막의 제조에 있어 기판은 초음파 유기세정 후 HCl과 H2O2(1:1)의 혼합용액을 사용하여 GaO2를 제거하고자 하였으며 이후 초순수로 세척하여 사용하였다. 초기 진공도는 3$\times$10-5 Torr이하였으며 기판온도 50$0^{\circ}C$에서 0.6 /s의 증착속도로 약 2000 증착하였다. 이렇게 제조된 ITO 박막은 5$\times$10-5 Torr이하의 진공분위기에서 $600^{\circ}C$로 열처리를 실시하였으며 열처리 시간의 변화에 따른 그들의 전기적, 구조적, 광학적 특성을 측정하였다. 열처리 과정을 통한 ITO박막은 투과도는 420nm의 영역에서 80%이상을 나타내었으며 이때의 면저항은 약 50ohm/ 이었다. 또한 I-V 곡선 측정에 의한 contact특성의 측정결과 열처리 전의 ITO contact은 n-GaN와 n-GaN에 대해 각각 ohmic과 schottky contact의 일반적인 contact 특성을 나타내었다. 그러나 이러한 contact 특성은 열처리 시간의 변화에 따라 변화하는 것을 확인할 수 있었다.

  • PDF

Trend and Prospect of Scrubber Technology for Regulatory on Sulfur Content in Marine Fuel Oil (선박 연료의 황 함유량 규제에 따른 스크러버 기술의 동향과 전망)

  • Eom, Hanki;Park, Byung Hyun;Jeong, Soon-Kwan;Kim, Sung Su
    • Prospectives of Industrial Chemistry
    • /
    • v.22 no.5
    • /
    • pp.1-13
    • /
    • 2019
  • 국제해사기구(IMO, international maritime organization)는 2015년부터 배출규제해역(ECA, emission control area)을 운항하는 선박은 황 함유량이 0.1%(m/m) 이하로 강화된 기준을 만족하는 연료를 사용해야 하며, 2020년부터는 모든 선박에 대해 황 함유량이 0.5%(m/m) 이하인 연료를 사용하거나 동등 이상의 성능을 갖는 배출가스 후처리 장치의 설치를 의무화하였다. 이에 따라, 선박에서 배출되는 오염물질을 제어할 수 있는 다양한 기술이 개발되고 있으며, 후처리 관점에서 습식 스크러버(wet scrubber)는 선박의 디젤 엔진에서 배출되는 이산화황(sulfur dioxide)을 저감시키기 위한 가장 적합한 해결책으로 알려져 있다. 습식 스크러버는 해수를 사용하는 개방형 스크러버(open loop scrubber)와 화학세정수를 사용하는 폐쇄형 스크러버(closed loop scrubber)로 구분된다. 습식 스크러버는 오염물질의 효율적인 처리가 가능하지만 유지보수비가 비싸고, 폐수 발생으로 인한 2차 오염발생 및 부식에 매우 취약한 단점이 있다. 따라서 최근에는 스크러버 내부의 부식을 방지하기 위한 내부식성 재질에 관한 연구와 흡수제(absorbent)의 고도화 연구가 활발히 진행되고 있다. 또한, 하이브리드형 스크러버(hybrid scrubber)는 개방형과 폐쇄형 스크러버의 장점을 결합한 기술로 황산화물의 배출을 규제하는 배출규제해역에서는 폐쇄형 스크러버를 가동하고, 선박이 공해상으로 진입할 경우 개방형 스크러버로 전환함에 따라 황산화물 배출 및 반응 후 세척수의 폐수배출 기준을 동시에 만족할 수 있다.

A Case of Kawasaki Disease Associated with Acute Renal Failure and Necrotizing Myositis (급성 신부전과 괴사성 근염을 동반한 가와사끼병 1례)

  • Ahn, So Hyun;Shim, So Yun;Sohn, Sejung;Lee, Seung Joo;Han, Un Seop
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.2
    • /
    • pp.207-209
    • /
    • 2003
  • Kawasaki disease is an acute febrile vasculitis affecting primarily infants and young children. In addition to the cardiovascular involvement, it may cause inflammatory changes in various organs and body systems : digestive, respiratory, urinary, nervous and musculoskeletal. A case is reported of atypical Kawasaki disease associated with acute renal failure and necrotizing myositis in the right gastrocnemius in a 10-year-old boy. In older children, uncommon age of onset and additional features less commonly associated with Kawasaki disease may contribute to a delayed diagnosis.

Inorgainc fouling and it fouling reduction in direct contact membrane distillation process (직접 접촉식 막 증발공정에서 무기 막오염 특성 분석 및 저감방법)

  • Lee, Tae-Min;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.2
    • /
    • pp.115-125
    • /
    • 2020
  • This study was aimed to examine inorganic fouling and fouling reduction method in direct contact membrane distillation(DCMD) process. Synthetic seawater of NaCl solution with CaCO3 and CaSO4 was used for this purpose. It was found in this study that both CaCO3 and CaSO4 precipitates formed at the membrane surface. More fouling was observed with CaSO4(anhydrite) and CaSO4·0.5H2O(bassanite) than CaSO4·2H2O(gypsum). CaCO3 and gypsum were detected at the membrane surface when concentrates of SWRO(seawater reverse osmosis) were treated by the DCMD process, while gypsum was found with MED(multi effect distillation) concentrates. Air backwash(inside to out) was found more effective in fouling reduction than air scouring.

Outgassing characteristics of an aluminum-alloy vacuum chamber (알루미늄합금 진공용기의 기체방출 특성)

  • 박종도;하태균;문상운;배인호;정석민
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.2
    • /
    • pp.164-172
    • /
    • 2001
  • We measured the pumpdown curves of an A5083 vacuum chamber and analyzed the outgassing in terms of desorption energies of water. The outgassing curves follow a ~$t^{-1.15}$ behavior before bakeout, which can be described by the first-order desorption of water molecules in the oxide layer. Analysis of the curves reveals that there exist several adsorption sites on the surface for water in the pressure range of ~$10^{-5}\;-\;10^{ -8}$Torr. Measurements utilizing the throughput method show that the room temperature outgassing rate is ~1{\times}10^{-13}$ Torr $\ell$/s $\textrm{cm}^2$ after 24 - h bakeout at $100^{\circ}C$.

  • PDF

The Development of Vital Sign Web Viewer Systems using HL7 Protocol (HL7 프로토콜을 이용한 생체정보 웹 뷰어 시스템 개발)

  • Lim, Se-Jung;Kang, Ki-Woong;Seo, Jong-Joo;Kim, Gwang-Jun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.2
    • /
    • pp.112-117
    • /
    • 2008
  • HL7 is well-Known standard protocol for text data generated in hospital information systems. Vital sign information web viewer systems is also the standard protocol for medical image and transfer. In order to embrace new technologies as telemedicine service, it is important to develope the standard protocol between different systems in the hospital, as well as the communication with external hospital systems. In this paper, we proposed integration method between vital sign web viewr systems and hospital information systems. Through the proper data exchange and modification of information management, HIS will offer better work flow to all hospital employee.

  • PDF

A Study on Tar Removal in Syngas Produced from Woodchip Gasification Using Oxidation Catalyst and Utilization of Syngas by Co-combustion (산화촉매를 이용한 우드칩 가스화 합성가스 내 타르 제거 및 합성가스 혼합연소 이용기술 연구)

  • Yoon, SangJun;Kim, YongKu;Lee, JaeGoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.175.1-175.1
    • /
    • 2011
  • 우드칩을 포함하는 화석연료대비 발열량이 낮은 바이오매스를 가스화를 통하여 활용하는 경우 타르 및 수트를 포함하는 저열량의 합성가스가 생성된다. 이러한 합성가스를 엔진을 통한 발전, 스팀, 수소 및 화학제품 생산으로 활용하기 위해서는 고효율의 타르 정제 및 제거가 필수적이다. 특히 착화가 어렵고 연소온도 및 연소율이 낮으며, 화염구간이 좁은 저열량의 합성가스를 이용하여 스팀을 생산하기 위해서는 많은 문제점으로 인하여 기술 개발이 필요하다. 본 연구에서는 하향류식 가스화기를 이용하여 우드칩을 연료로 합성가스를 제조하였으며, 합성가스에 포함되어 있는 타르 및 수트와 같은 미반응 물질을 제거할 수 있는 집진, 세정장치를 설계 및 제작하였다. 특히 고효율 타르의 제거를 위하여 두 종류의 산화촉매를 이용한 합성가스 내 타르의 제거 연구를 수행하였다. Ru 촉매를 이용하는 경우 합성가스 내 타르의 농도를 100ppb 정도까지 저감이 가능하였다. 정제된 합성가스는 유류 혼소 버너를 통하여 보일러 연소실에서 혼합연소되어 30만kcal/h의 열을 공급함으로써 스팀을 생산 하였으며, 생성된 스팀은 블록 건조 시설에서 이용하였다.

  • PDF

Controller Design for Automatic Evacuation Disposal System with Multi-sensors (다중센서를 적용한 자동배변처리기용 제어기 설계)

  • Moon, I.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.71-77
    • /
    • 2011
  • This paper proposes a design of controller for automatic evacuation disposal system with suction, collecting, washing, and drying functions to be useful for excretion care of long-term bedridden patients. It is desirable that the system can discriminate excreta such as feces and urine severally, and dispose of them without having additional efforts of caregivers. This paper describes a method to improve the discrimination ability by using multi-sensors, and proposes disposal processes according to the type of excrements. As a result the automatic evacuation disposal system can perform an efficient operation in the excrement care. Experimental results using artificial excrements show the automatic evacuation disposal system is effective and feasible to assist the excrement care.