• Title/Summary/Keyword: 세라믹 대퇴 골두

Search Result 2, Processing Time 0.019 seconds

Cementless Total Hip Arthroplasty Using Ceramic Femoral Head on Cross-Linked Ultra-High-Molecular Weight Polyethylene Liner in Patients Older than 65 Years: Minimum Five-Year Follow-Up Results (세라믹 대퇴 골두 및 교차결합 초고분자량 폴리에틸렌 라이너를 이용한 65세 이상 무시멘트형 인공 고관절 전치환술: 최소 5년 중기 추시 결과)

  • Yun, Ho Hyun;Cheong, Ji Young;Sim, Hyun Bo;Park, Jae Hong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.490-497
    • /
    • 2018
  • Purpose: To evaluate the utility of ceramic-on-polyethylene articular bearing surface when cementless total hip arthroplasty is performed in patients older than 65 years through an analysis of the minimum five-year follow-up results using the ceramic femoral head and cross-linked polyethylene liner. Materials and Methods: From March 2010 to September 2012, 51 patients (56 hips) who were older than 65 years were enrolled in this retrospective study. The mean age at surgery was $70.9{\pm}5.1years$ old. A clinical assessment was analyzed using the Harris hip score. For the radiographic assessment, the cup inclination and anteversion, stem alignment, and wear amount were measured. The postoperative complications were also determined. Results: The mean Harris hip score was improved from preoperative 48 points to postoperative 87 points (p<0.05). The mean cup inclination was $40.9^{\circ}{\pm}6.4^{\circ}$ and the mean cup anteversion was $20.3^{\circ}{\pm}8.1^{\circ}$. The mean cup anteversion of the elevated liner-used group (16 cases) was $14.3^{\circ}{\pm}7.9^{\circ}$ and the mean cup anteversion of the neutral liner used group (40 cases) was $22.4^{\circ}{\pm}9.1^{\circ}$ (p<0.05). The mean stem alignment angle was $0^{\circ}$ (range, varus $4^{\circ}$-valgus $4^{\circ}$). The mean linear wear amount was $0.458{\pm}0.041mm$ and the average annual linear wear rate was $0.079{\pm}0.032mm/yr$. Six cases (10.7%) of intraoperative periprosthetic femoral fractures were encountered. Conclusion: Based on these results, the use of a ceramic-on-polyethylene articular bearing surface in elderly patients with cementless total hip arthroplasty is beneficial. On the other hand, careful effort is needed to prevent intraoperative periprosthetic femoral fractures.

Prediction of Stress Distribution in the Ceramic Femoral Head after Total Hip Replacement (인공고관절 치환술 후 세라믹 대퇴골두에서 발생하는 응력분포 예측)

  • Han, Sung-Min;Chu, Jun-Uk;Song, Kang-Il;Park, Sung-Hee;Choi, Jae-Bong;Kim, Jung-Sung;Suh, Jun-Kyo Francis;Choi, Kui-Won;Youn, In-Chan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.6
    • /
    • pp.680-685
    • /
    • 2012
  • Ceramic femoral heads are now widely used in Total Hip Replacement (THR). Due to their high biocompatibility and low ductility, ceramic femoral heads are considered to be suitable for young and active patients. However, as in testing the mechanical stability of the femoral head, the conventional proof test (standard ISO 7206-10) has its limit of showing axisymmetric stress distribution on the contact surface, while non-uniformed stress distribution is expected after THR. Since non-uniformed stress distribution can result in the increased probability of ceramic femoral head fracture, it is considerable to evaluate the stress distribution in vivo-like conditions. Therefore, this study simulated the ceramic femoral heads under in vivo-like conditions using finite element method. The maximum stress decreased when increasing the size of the femoral head and stress distribution was concentrated on superior contact surface of the taper region.