• Title/Summary/Keyword: 성 형한계

Search Result 1,218, Processing Time 0.039 seconds

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.

비평형 그린함수 방법을 이용한 저유전-고유전-게이트-스택 구조에서의 터널링 장벽 제어

  • Choe, Ho-Won;Jeong, Ju-Yeong
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.217-220
    • /
    • 2013
  • 기존 플래시 메모리의 물리적 한계를 극복하여 저전압, 저전력 비휘발성 메모리 소자를 얻기 위해서는 터널링 장벽 제어가 필수적이며, 저유전체와 고유전체를 적층한 VARIOT 구조는 터널링 장벽 제어에 매우 효과적이다. 우리는 비평형 그린함수 방법을 이용하여 전자 수송을 계산함으로써, VARIOT 구조가 기존의 단일 유전층 구조에 비해 비휘발성 메모리 관점에서 얼마나 향상되었는지를 분석하고, 터널링 장벽 제어에 있어 고유전체가 가져야 할 가장 유리한 조건을 찾아내었다. 또한 유효질량이 에너지 장벽(유전층)의 전계 민감도와 거의 무관함을 보임으로서 시뮬레이션 결과가 합리적임을 증명하였다.

  • PDF

유비쿼터스 환경과 보안

  • 김형중
    • Information and Communications Magazine
    • /
    • v.20 no.5
    • /
    • pp.635-644
    • /
    • 2003
  • 유비쿼터스 컴퓨팅 환경에서만 볼 수 있는 보안문제를 가용성, 인증성, 익명성 관점에서 살펴보았다. 이 분야의 보안기술은 기존의 방법과 여러 면에서 다르다. 무선 애드학 네트워크 또는 센서 네트워크의 예에서 보는 것처럼 제한된 계산 성능과 메모리, 전력소모를 최소화히기 위한 통달거리 제한 및 아이들 상태 유지, 온라인 서버가 존재하지 않으므로 인해 발생하는 집중형 기술 구현이 불가능한 한계로 인해 새로운 이슈들이 등장하고 있다. 이런 문제들과 해결책 일부를 소개한다.

Institutional Improvement for Practical Applications of the Smart Water Grid in South Korea (지능형 물관리(Smart Water Grid)의 제도적 한계와 개선방향)

  • Park, Sung-Je;Ryu, Si-Saeng
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.110-110
    • /
    • 2011
  • 최근 국제적으로 물관리의 차세대 개념으로서 지능형 물관리(Smart Water Grid)가 활발하게 논의되고 있다. 우리나라에서도 일부 학자들을 중심으로 이에 대한 개념이 도입되고 있다. 현재까지 정리된 지능형 물관리의 개념은 최근 급성장한 정보통신기술을 활용하여 기존에 비효율적으로 운영되는 물관리의 시스템을 획기적으로 개선하자는 것이다. 따라서 이론적으로는 물의 생산, 정수, 배송 그리고 이용과 처리에 이르는 전 과정을 실시간으로 통합하여 관리하는 것이 가능하다. 국제적으로는 IBM과 Siemens 등과 같이 정보통신과 물산업을 선도하는 기업 주도의 기술개발이 진행되는 단계이다. 2000년대 초반에는 용수수급의 효율화를 위한 장치개발에 주력하였으나, 현재에는 용수수급과 관련된 제반사항에 대한 기술적 통합시스템 구축으로 적용범위를 넓히고 있다. 우리나라에서도 도시인프라 자료의 통합관리와 수질 모니터링 시스템 구축이 추진되었으며, 2010년 12월 발표된 새만금종합개발계획에서는 본격적으로 활용을 검토하고 있다. 그러나 지능형 물관리의 기술적 통합시스템 전략은 곧 심각한 제도적 장벽에 직면할 것이다. 아무리 우수한 기술적 시스템이 개발된다고 하여도 제도적 기반의 구축이 없으면 국민경제에 도움이 되는 현실적용에는 한계가 있다. 기존에 확립된 물관리의 제도적 기반으로는 한정된 지역의 좁은 영역에서 활용될 수밖에 없다. 이것은 우리나라의 물관리가 기본적으로 법적, 제도적, 행정적 차원에서 분리되어 운영되고 있기 때문이다. 본 연구는 지능형 물관리가 지향하는 기술적인 통합시스템 구축이 당면할 제도적 한계를 도출하고 이를 극복하기 위한 정책적 방향을 제시하고자 한다. 또한 2009년 국회에 제출된 물관리기본법(안)에 지능형 물관리의 개념을 도입하는 방안을 모색하고자 한다.

  • PDF

A Method for Providing a Proactive Robot Service (능동형 로봇 서비스 제공 방법)

  • Go, Young-Cheol;Sohn, Joo-Chan
    • Annual Conference of KIPS
    • /
    • 2007.05a
    • /
    • pp.643-644
    • /
    • 2007
  • 서비스를 제공받는 대상의 상황정보를 고려한 서비스 제공은 좀더 사용자에게 적절한 서비스를 제공 가능하게 할 수 있다. 그러나, 서비스 제공을 위하여 사용자의 주변 상황 분석에 필요한 정보의 습득에는 한계가 있다. 따라서, 본 연구에서는 사용자에게 제공 가능한 서비스를 한정하고 제한된 상황에서 상황정보를 습득하고 분석하여 사용자에게 능동적으로 서비스를 제공하는 방법을 제시한다. 제한된 상황과 서비스는 베이지안 네트워크를 이용하여 모델링하여 외부 입력의 불확실성을 해소한다.

Structural Safely Analysis of a Modified 1-2W Type Greenhouse Enhanced for Culturing Paprika (착색단고추 재배용 1-2W형 개조온실 구조의 안정성 검토)

  • Suh, Won-Myung;Choi, Man-Kwon;Bae, Yong-Han;Lee, Jong-Won;Yoon, Yong-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.17 no.3
    • /
    • pp.197-203
    • /
    • 2008
  • This study was performed to check the structural safety of modified 1-2W Greenhouses to be utilized fur growing Paprika. This type of greenhouse was derived from being remodeled by enhancing the column height of conventional 1-2W type greenhouses. According to the results of structural analysis performed by SAP-2000, there was not significant change in critical snow depth in spite of increasing the column height of 1.2 m by welding. But the critical wind velocities were shown to be $26.0\sim4l.0m/s$, which were $3\sim18%$ lower wind velocities compared with those critical velocities estimated for typical type of 1-2W greenhouse. Under the wind loads, those maximum section forces such as shear force, axial force, and bending moment, together with the deformed frame shape of strained greenhouse, were almost similar in both typical type and modified type. Maximum bending moment of column was found at eave's height of column on windward side. Under the snow loads, those maximum section forces such as shear farce, axial force, and bending moment, together with the deformed frame shape of strained greenhouse, were almost similar in both typical type and modified type. Maximum section forces except axial force was found at eave's height of column. Maximum axial force was found at inner column. Soil bearing capacity together with the total foundation resistance against wind upheaval was found to be consistently safe enough to resist to both wind load and snow load.

Probabilistic Risk Assessment of a Cable-Stayed Bridge Based on the Prediction Method for the Combination of Failure Modes (붕괴모드 조합 예측법에 의한 PSC사장교의 위험도평가)

  • Park, Mi-Yun;Cho, Hyo-Nam;Cho, Taejun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.647-657
    • /
    • 2006
  • Probabilistic Risk Assessment considering statistically random variables is performed for the preliminary design of a Cable Stayed Bridge, which is Prestressed Concrete Bridge consisted of cable and plate girders, based on the method of Working Stress Design and Strength Design. Component reliabilities of cables and girders have been evaluated using the response surface of the design variables at the selected critical sections based on the maximum shear, positive and negative moment locations. Response Surface Method (RSM) is successfully applied for reliability analyses for this relatively small probability of failure of the complex structure, which is hard to obtain through Monte-Carlo Simulations. or through First Order Second Moment Method that can not easily calculate the derivative terms of implicit limit state functions. For the analysis of system reliability, parallel resistance system consisting of cables and plate girder is changed into series connection system and the result of system reliability of total structure is presented. As a system reliability, the upper and lower probabilities of failure for the structural system have been evaluated and compared with the suggested prediction method for the combination of failure modes. The suggested prediction method for the combination of failure modes reveals the unexpected combinations of element failures in significantly reduced time and efforts compared with the previous permutation method or system reliability analysis method, which calculates upper and lower bound failure probabilities.

Development of generator excitation system with main/standby controller in Inchun thermal power plant #4 (인천화력 4호기 발전기용 주/부 제어기를 갖는 정지형 여자시스템 개발)

  • 류호선;김수열;김장목;임익헌
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.507-514
    • /
    • 1999
  • 한국전력에서는 인천화력 4호기 수명연장의 일환으로 여자시스템 교체가 이루어졌다. 기존의 회전형 여자 시스템은 발전기축에 부여자기와 교류여자기가 부착되어 회전하는 형태로 과거 스위칭소자 용량의 한계를 극복하기 위하여 설계된 시스템으로 전력연구원에는 회전형 여자시스템을 새롭게 개발된 아날로그와 디지털의 하이브리드 제어기와 대용량 사이리스터 제어정류기를 가지고 잇는 정지형 이중화 여자시스템으로 교체하였다. 설비의 신뢰성을 높이기 위하여 정지형 여자시스템의 상태를 순시 감시하기 위한 데이터 취득 시스템이 설치 되었고 위상제어정류기는 운전시 1대가 고장이 발생하더라도 발전기의 전부하 능력을 유지하기 위하여 3대가 병렬로 운전되는 N+1 방식을 채택하였다. 시스템의 신뢰성 시험은 성능평가를 위한 시운전시에 검증되었으며 성공적으로 운전중에 있다.

  • PDF

Design of a Storage Structure for Main Memory XML DBMS (주기억 상주형 XML DBMS 저장 구조 설계)

  • Lim, Hyuck-Soo;Noh, Hyun-Jong;Lee, Kyu-Chul
    • Annual Conference of KIPS
    • /
    • 2005.11a
    • /
    • pp.7-10
    • /
    • 2005
  • 최근 인터넷을 중심으로 한 첨단 기술 산업이 발달함에 따라 고성능 트랜잭션 처리가 요구되고, XML 관련 기술들 역시 확대 적용되고 있다. 이에 따라 디스크 기반 DBMS 의 한계를 극복하고, 점차 사용 범위가 확대되고 있는 XML 기술을 지원하기 위한 시스템의 필요성이 대두되고 있다. 기존의 XML 저장 방법은 대부분 XML DOM 구조 정보만을 저장하는 것이었으나, 이 방법은 XQuery를 처리하는 속도면에 한계가 있었다. 본 논문에서는 이 점을 해결하기 위해 2 중의 인덱스 구조를 두어, XQuery 처리 속도를 향상시킬 수 있는 주기억 상주형 XML DBMS 의 저장 구조를 설계 한다.

  • PDF

Conical Slope Stability of Tertiary Basalt Based on the Geological Cross-Sections (지질횡단면을 활용한 원추형 현무암 비탈면 안정성)

  • Myeong-Hyeok Ihm;Sung-Pil Hwang;Byung-Suk Park;Jun-Sang An;Woo-Seok Kim
    • The Journal of Engineering Geology
    • /
    • v.34 no.3
    • /
    • pp.447-457
    • /
    • 2024
  • This study investigated a cut-slope surface containing Tertiary faults, representing a conical-shaped slope with strike varying from N44°E to NS, N50°W, and finally N70°E. The slope consists mainly of basalt, with discontinuities in the slope including faults, fault zones, fracture zones, shear joints, and extension joints. The type and scale of failure vary with the strike of the slope and the strikes of discontinuities, with plane and wedge failure predominating. Based on face-mapping data, SMR (slope mass rating), rock physical and mechanical properties, analysis of stereonet projections and geological cross-sections, and critical equilibrium analysis, optimal slope stability determination was found to involve the countermeasure method, the slope gradient relief method, the green soil surface treatment method, and a fall prevention measure. After application of the countermeasure method, both dry and wet slope conditions exceeded allowable safety factors. It is expected that the preparation of geological cross-sections of various representative sections perpendicular to the surface of the slope, and the application of corresponding countermeasure methods, will be reasonable tools for three-dimensional analysis of slope stability. If the strike of the slope varies widely, it is necessary to prepare geological cross-sections, and the section used for critical equilibrium analysis must be established as the basic section.