• Title/Summary/Keyword: 성형수술

Search Result 699, Processing Time 0.032 seconds

SURGICAL CORRECTION OF A CUPID'S BOW USING A DOUBLE Z-PLASTY: REPORT OF A CASE (중복 Z-성형술을 이용한 큐피드활의 교정)

  • Ryu, Sun-Youl;Seo, Il-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.1
    • /
    • pp.66-70
    • /
    • 2005
  • Cupid's bow, upper lip, columella, and ala of nose are esthetically important, in which their symmetrical plasties determine success or failure of the surgery in cleft lip and palate patients. Z-palsty and its modifications are simple and effective. The double Z-plasty is economical in surgical time and esthetics in reconstructing the cupid's bow compared with other methods. We report a 29-year-old male patient who represented reversed cupid's bow and whistle deformity after the primary repair of the cleft lip. He was corrected the cupid's bow using a double Z-plasty. The reversed cupid's bow was corrected to a normal shape and the whistle deformity disappeared. The tightness of the upper lip was relieved after the operation. The double Z-plasty was esthetically successful because the procedure was limited in the vermilion and did not produce a new scar on the skin. Furthermore, the lip tubercle became protuberant. The cupid's bow was symmetrically smoothly curved at 4 years after the operation. These results indicate that the double Z-plasty is simple, less traumatic to the surrounding tissues, and suitable for the correction of whistle deformity.

Correction of Secondary cleft lip-nasal deformity; secondary rhinoplasty in children and adults (구순열 이차비기형의 교정; 아동과 성인에서의 이차 비성형술)

  • Song Gin-Ah;Myung Hoon;Hwang Soon-Jung;Seo Byoung-Moo;Lee Jong-Ho;Choung Pill-Hoon;Kim Myung-Jin;Choi Jin-Young
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.6 no.1
    • /
    • pp.17-25
    • /
    • 2003
  • Correction of the cleft-lip nasal deformity is a difficult task that requires clear understanding of the associated complex anatomy and function as well as the operation time, the selection of an operation method, On the expectation that it helps enhance understanding the current trend of cleft-rhinoplasty, authors analyzed secondary rhinoplasty between 1999 and 2002, In both the unilateral and bilateral cleft lip rhinoplasty, we reviewed the timing of repair, site of correction and it's major technique, incision or approach method, autogenous cartilage graft method, All patients with a septal deviation did not have a septal surgery, We were active in alar and nasal tip surgery and passive in septal and dorsal deformity correction, And for children, we used a conservative method but for adults, we used radical approach, Most surgeries are focused on esthetic goal and we thought that objective evaluation for nasal obstruction was needed for bener and predictable outcome.

  • PDF

Plastic surgery experience and addiction of female college students (여대생의 미용성형 경험 실태와 성형중독)

  • Kim, Young A;Cho, Chung Hayng-In
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2017.05a
    • /
    • pp.417-418
    • /
    • 2017
  • 본 연구에서는 여대생의 미용성형 경험 실태와 중독성향에 영향을 미치는 요인을 조사하였다. 무작위 표집한 여대생 223명을 대상으로 2014년에 자료 수집하였다. 수집된 자료는 서술적 통계, t-test, ANOVA, logistic regression으로 분석하였다. 연구결과, 102명(45.7%)은 최소 1회 이상의 미용성형 경험이 있었고, 비외과적인 미용성형 경험이 외과적인 미용성형 경험의 비율보다 높았다. 여대생의 성형중독 성향에 유의한 영향을 미친 변수는 과거의 성형 경험과 성형수술 수용성, 외모에 대한 사회문화적 태도, 외모평가였다. 이 변수들의 설명력은 52% (Nagelkerke R2=.52) 였다. 본 연구를 통하여 여대생의 미용성형 경험 현황과 성형중독에 영향을 미치는 개인적, 사회적 요인을 파악하였다. 이제 여대생들에 있어 성형중독은 무시할 수 없는 심각한 사회문화적 문제 중의 하나이다. 연구결과는 이러한 사회문화적 문제를 파악하고 예방하기 위한 근거자료로 사용될 수 있으리라 사료된다.

  • PDF

Early Changes of Left Ventricular Geometry and Function after Surgical Ventricular Restoration and Mitral Valve Annuloplasty: Magnetic Resonance Imaging (외과적 심실 복원과 승모판 고리성형 후 좌심실 형태와 기능의 초기 변화: 자기공명영상)

  • Choi, Byoung-Wook;Chang, Byung-Chul;Kim, Young-Jin;Hur, Jin;Lee, Hye-Jeong;Kim, Tae-Hoon;Choe, Kyu-Ok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.1
    • /
    • pp.40-48
    • /
    • 2008
  • Purpose : We sought to determine the early change of ventricular geometry and function after concomitant surgeries of modified Dor procedure and mitral valve annuloplasty by using magnetic resonance imaging. Materials and Methods : We enrolled 21 patients with dilated heart failure who underwent modified Dor procedure (n=8), mitral valve annuloplasty (n=6), or both surgeries (n=7). Cine MRI was used to assess left ventricular dimensions and function before and after surgery. We measured the left ventricular end-diastolic and end-systolic volumes and the dimensions of the left ventricular long-axis and short-axis. Left ventricular stroke volume, ejection fraction, and sphericity index were calculated from these measurements. These parameters were analyzed and compared between three different surgery groups to explain the combined effect of the concomitant surgeries. Results : MRI was performed within average $12\;{\pm}\;15$ days (range 1-58 days) before and $38\;{\pm}\;50$ days (range 7- 231 days) after the surgery. The patients who underwent concomitant surgeries had more profound enlargement of left ventricle and decreased contractility prior to surgery than those in the patients who underwent single surgical procedure. Left ventricular end-diastolic volume and endsystolic volume significantly decreased in all patients regardless of surgery type after surgery. Ejection fraction significantly increased only in the patients who got modified Dor procedure without mitral valve annuloplasty (25.4% to 40.7%). Sphericity index increased in patients with modified Dor procedure but decreased in patients with mitral valve annuloplasty (0.65 to 0.78 vs. 0.75 to 0.65). In the patients who underwent concomitant surgeries showed no significant change in sphericity index after surgery. Conclusion : The early change of the left ventricular geometry and function after the concomitant surgeries with modified Dor procedure and mitral valve annuloplasty in patients with dilated heart failure includes a marked reduction in left ventricular volume and in stroke volume. The shape of the left ventricle does not change because the effect of sphericity index decrease from mitral valve annuloplasty is counteracted by the effect of sphericity index increase from modified Dor procedure. Improvement of left ventricular ejection fraction is not the early change after the concomitant surgeries.

  • PDF

Results of Mitral Valve Repair in Patients with Congenital Mitral Disease (선천성 승모판막 기형 환자에서 승모판막 성형술)

  • Jang, Hee-Jin;Lee, Jeong-Ryul;Rho, Joon-Ryang;Kim, Yong-Jin;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.175-183
    • /
    • 2009
  • Background: Mitral valve abnormalities in the pediatric population are rare. Mitral valve replacement or pediatric mitral lesions can cause problems such as a lack of growth potential. There re only limited experiences with mitral valve repair at any institution, so the purpose of his study is to evaluate the outcomes of mitral valve repair n pediatric patients. Material and Method: Sixty-four consecutive children (28 males and 36 females) with a mean age of $5.5{\pm}4.7$ years underwent mitral valve repair for treating their congenital mitral valve disease between January 1996 and December 2005. The patients were divided into two groups: group 1 (34 patients (53.1%)) had isolated disease (mitral anomaly with or without trial septal defect or patent ductus arteriosus) and group 2 (30 patients (46.9%)) had complex disease (mitral anomaly with concurrent intracardiac disease, except atrioventricular septal defect). Result: The overall in-hospital mortality was 6.3%; group 1 had 5.9% mortality and group 2 had 10.0% mortality. The postoperative morbidity was 18.8%; group 1 and 2 had 14.7% and 23.3% postoperative morbidity, respectively, and there as no significant difference among the groups. The median follow-up was 4.6 years range: $0.5{\sim}12.2$ years). The 10-year survival rate was 95.3%. The 10-year freedom from re-operation rate was 76.1% with 10 re-operations. The majority of the functional classifications were annular dilatation and leaflet prolapse. A mean of $2.1{\pm}1.1$ procedures per patient were performed. The echocardiography that was done at the immediate postoperative period showed a significant improvement in the mitral valve function. The follow-up echocardiographic results were significantly improved. However, mitral stenosis newly developed over time, and there ere significant differences according to the repair strategies. Conclusion: The patients who underwent mitral valve repair for congenital mitral anomalies showed good results. The follow-up echocardiography revealed satisfactory short-term and long-term results. Close follow-up is necessary to detect the development of postoperative mitral stenosis or regurgitation.

Operation Room Fire: Caution for Using Electrocautery after Rinsing Operation Field at the End of the Surgery with Alcohol-Based Cleansing Solutions (수술방 화재: 수술 종료 시 알코올 함유 피부 소독액을 이용한 수술부위 세척 이후 전기소작기 사용 주의)

  • Song, Jong Keun;Shin, Hyojeong;Lee, Jun Yong
    • Journal of the Korean Burn Society
    • /
    • v.22 no.2
    • /
    • pp.34-37
    • /
    • 2019
  • Fires in operating rooms rarely occur. However, this type of disaster can complicate almost any surgical procedure. Fuel, heat and oxygen are related with fire outbreak. When ignition sources such as alcohol-based surgical preparation solutions are present, the risk of an operating room fire increases, and burns are more severe in such conditions. Many manufacturers recommend waiting at least three minutes after application to allow complete drying for reduce fire risk. There are a few studies regarding flame burns in the operation room, although most of these studies are related to preoperative skin preparation. However, alcohol containing solutions can be used occasionally for cleansing of the operation field after the surgery, therefore, the surgical team should pay attention to surgical fires, even if they have completed the operation successfully. We present our case of a post-operative flame burn and introduce some precautions that will reduce the risk of alcohol burns.

A Study on the PMMA Lens Fabrication for Surgical Light Based on Injection Molding Convergence Process (사출성형 융합공정 기반 수술실 무영등용 PMMA 렌즈 제작에 관한 연구)

  • Kang, Bo-An;Oh, Hyeong-Jong;Jeong, Byeong-Ho;Jeong, Nam-In
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.1
    • /
    • pp.43-48
    • /
    • 2015
  • We studied on the injection molding conditions of defect-free PMMA lens for surgical light. When the heat temperature of mold is low, more imperfect molding or weldlines and flow marks have showed. A defective lens depends on low fluidity of the PMMA resin and its temperature is high, a flexural strain has occurred. The longer cooling time of specimens, the more cracks have occurred due to resin crystallization. In this study, optimal molding conditions for defect-free PMMA lens is as follows. The heat temperature of core mold was 110 [$^{\circ}C$] and also the cooling time was 25 [sec]. PMMA materials can realized low expense to produce plastic optical lens and applications.

Linked Semi-constrained or Unlinked TER: What We Should Know Before We Use? (연결형, 반구속형 또는 비연결형, 비구속형 주관절 인공 관절 성형술: What We Should Know Before We Use?)

  • Jung, Hong-Jun;Jeon, In-Ho;Chun, Jae-Myeung
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.99-104
    • /
    • 2011
  • Purpose: Total elbow arthroplasty (TEA) is still in its infancy as compared with other forms of arthroplasty. TEA designs have evolved with experience, but comparatively little long-term outcome data is available. This article provides an overview of the current states of linked, unlinked, and convertible total elbow arthroplasty. Material and Method: The designs of total elbow prostheses can be subdivided into three categories: unlinked, linked, and convertible. This article provides an overview of the current states of linked, unlinked, and convertible total elbow arthroplasty. Results and Conclusion: By proper patient selection and by utilizing implant design advances, improvements in cementation techniques, a meticulous surgical technique, and appropriate postoperative rehabilitation, total elbow arthroplasty can provide a high level of patient satisfaction and pain relief.

A Modified Technique in Surgical Correction of Ebstein Anomaly (Ebstein 기형 교정의 변형 술식)

  • 윤석원;윤태진;박정준;서동민
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.817-821
    • /
    • 2002
  • There are various surgical techniques in repairing Ebstein anomaly, but residual tricuspid regurgitation and compromized right heart function may ensue in some cases. We report our clinical experience of Ebstein anomaly and atrial flutter in a 19-year-old male patient who underwent simple modified tricuspid annuloplasty, hi-directional cavopulmonary shunt and cryoablation of cavotricuspid isthmus.