• Title/Summary/Keyword: 성분원소

Search Result 830, Processing Time 0.03 seconds

Quality Assurance and Control for Elemental Analysis of Air Dust by Neutron Activation Analysis (중성자 방사화분석에 의한 대기먼지 중 원소분석을 위한 품질보증 및 관리)

  • 문종화;김선하;임종명;정용삼;김영진
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.229-230
    • /
    • 2003
  • 중성자 방사화분석법은 핵반응을 통해 생성시킨 방사성 동위원소로부터 방출되는 방사선을 검색하여 절대적으로 성분원소를 정량하는 핵분석기술(Nuclear Analytical Techniques)이다. 현재 한국원자력연구소의 중성자 방사화분석실에서는 대기환경분야 응용연구로서 수년 동안 대기분진을 채집하여 미량 성분원소를 정량하고 있으며, 방법의 유효화와 측정결과의 신뢰성을 확보하기 위하여 시료의 채집 및 준비, 원소분석, 측정결과의 검증 등 분석과정에 대한 품질관리를 수행하고 있다. (중략)

  • PDF

Measurement of Oxygen Isotope Ratio in Water Vapor by using Tunable Diode Laser Absorption Spectroscopy(TDLAS) - II (다이오드레이저 흡수분광법을 이용한 수증기의 산소 동위원소 성분비 측정 - II)

  • Jung, Do-Young;Park, Sang-Eon;Kim, Jae-Woo;Ko, Kwang-Hoon;Im, Kwon;Jung, Eui-Chang;Kim, Chul-Joong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.202-203
    • /
    • 2003
  • 여러 가지 원소의 동위원소 성분 분석은 생물학, 화학, 환경학, 연대학, 기후학 연구에 있어서 중요한 정보를 제공하는 유용한 수단이다. 동위원소 성분비를 측정하는 방법으로는 가스 동위원소 질량분석기를 이용한 방법이 사용되어 왔지만, 최근 다이오드 레이저의 발달과 함께 다이오드레이저 흡수분광법(TDLAS)이 개발되어 사용되고 있다. TDLAS 방법의 경우 질량분석기를 이용하는 방법에서는 측정이 불가능한 동일질량 분자의 동위원소 성분비를 측정할 수 있다. (중략)

  • PDF

Studies on Elemental Carbon and Its Origin in Black Surface Layer on Stone Pagoda in Urban Environments (도심에 위치한 석탑 표면 흑색층 내의 원소탄소성분과 그 기원연구)

  • Do, Jin-Young
    • Journal of Conservation Science
    • /
    • v.20
    • /
    • pp.55-65
    • /
    • 2007
  • Black surface layers collected from stone pagodas were analyzed to study the effects of carbon compounds on the blackening of stone surface layer. The total amounts of carbon was measured through elemental analyser. Organic and elemental carbon were measured by combustion ihrornatographic $CO_2$ determination after elimination of carbonates carbon with acid treatment. The elemental carbon concentration in the black surface layer measured 0.52wt.%. This value is not sufficient to explain the complete blackening of stone surface. To trace the origin of carbon in black surface layer on the stone pagoda, aerosol samples for PM 10 were collected at the near sites of the pagoda. The major components of them were soluble ions(42.8wt.%), carbon(38.4 wt.%) and crustal matter(16wt.%). From the high content(13wt.%) of elemental carbon in aerosol ran be deduced that it may be a prime origin for the elemental carbon in the black surface layer on the stone pagoda. The crustal matter in aerosol can be also a origin of silicate mineral in black surface layer and plays a important role in the darkening of black surface layer.

  • PDF

Trace Elements and Source Assessment of Street Dust in Daegu, Korea (대구지역 도로먼지에 함유된 미량원소성분과 오염원 평가)

  • Song, Hee-Bong;Lee, Eun-Young;Do, Hwa-Seok;Jung, Cheol-Su;Shin, Dong-Chan;Lee, Myoung-Sook;Paek, Yoon-Kyoung;Jeon, Seong-Suk;Shin, Won-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.7
    • /
    • pp.793-800
    • /
    • 2007
  • A total of 48 samples of street dust were collected in Daegu area during April and May 2006, were sieved below 100 ${\mu}m$, and analysed by ICP for the analysis of 14 elements after an acid extraction. Results obtained from the source assessment of trace elements using enrichment factor showed that Ca, Fe, K, Mg, Mn, Na and V were influenced by natural sources such as soil and dust, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by urban anthropogenic sources such as fuel combustion and waste incineration. The measured values were remarkably higher in components from natural sources than in components from urban anthropogenic sources. The concentrations of trace elements in Daegu area were generally higher than in other foreign cities. Samples originated from industrial and commercial areas had higher concentrations of trace elements and pollution indices of heavy metals than those from residential and green areas. The correlation analysis among trace elements indicated that the correlations among components from urban anthropogenic sources were much significant, while those among components from natural sources were less correlated. In addition there were significant correlations between traffic density and components from urban anthropogenic sources.

Trace Element Analysis and Source Assessment of Parking Lot Dust in Large Shopping Mall (대형유통업소주차장의 축적먼지 중 미량원소성분 분석과 오염원 평가)

  • Song, Hee-Bong;Ahn, Jeong-Eem;Jung, Yeoun-Wook;Yoon, Ho-Suk;Keum, Jong-Lok;Do, Hwa-Seok;Kim, Sun-Suk;Kim, Jong-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.168-176
    • /
    • 2012
  • A total of 48 dust samples were collected from large shopping mall parking lots in Daegu metropolitan city in March 2011. Samples were sieved through a 100 ${\mu}m$ mesh and the concentration of 14 elements have been determined using by ICP after acid extraction. Results showed that Ca, Fe, K, Mg, Mn, Na and V were affected by natural sources while Cd, Cr, Cu, Ni, Pb and Zn were affected by anthropogenic sources. The measured values were remarkably higher in components from natural sources than in components from anthropogenic sources. Anthropogenic trace element concentrations of ground roof dust were higher than those of ground and underground indoor dust. A large percentage of trace elements came from natural sources rather than anthropogenic sources. The percentage composition of chemicals of ground roof dust were higher than those of ground and underground indoor dust. This study showed that investigated parking lots were rarely contaminated with hazardous heavy metals. The heavy metal pollution of ground roof were higher than those of ground and underground indoors. The correlation analysis among trace elements suggest that components in ground roof were more highly correlated than those in ground and underground indoor. Also anthropogenic trace element levels were well correlated with parking lot age and parking density.

Characteristics of Trace Element Concentrations in Dust by Facilities and Areas in Daegu, Korea (대구지역 축적먼지 중 미량원소성분의 시설별 및 지역별 농도분포)

  • Song, Hee-Bong;Do, Hwa-Seok;Kwak, Jin-Hee;Kim, Jong-Woo;Kang, Jae-Hyoung;Phee, Young-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.3
    • /
    • pp.287-295
    • /
    • 2010
  • Dust samples have been collected from streets, schools, subway stations and households in Daegu metropolitan city. Samples were sieved through a 100 ${\mu}m$ mesh and the concentration of 14 elements have been determined using by ICP after acid extraction. Results showed that Ca, Fe, K, Mg, Mn, Na and V were influenced by natural sources while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources. The measured values were remarkably higher in components from natural sources than in components from anthropogenic sources. In particular, school dust had higher levels of Ca and Pb and subway station dust had higher levels of Cu and Zn. The percentage composition of chemicals from subway stations, households, and schools were remarkably higher in components from anthropogenic sources than that from streets. It is well recognized that anthropogenic sources were affected by indoor dust. Results of pollution index of hazardous heavy metals indicated that schools, households, and subway stations were more contaminated than streets and urban areas typically had higher pollution index than rural areas. The correlation analysis among trace elements seem to suggest that there were correlations between components of soil/road dust resuspension, and components of waste incineration and fuel combustion.

Elemental concentrations of atmospheric particles in Cheonan during 2006 (2006년 천안시 대기 입자의 원소 성분 특성)

  • Oh, Se-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1782-1786
    • /
    • 2008
  • To investigate the characteristics of elemental components of atmospheric particles in Cheonan, atmospheric particles were sampled using a high volume air sampler equipped with a 5-stage cascade impactor during 2006. 16 elemental concentrations in fine and coarse particles were determined using ICP-AES and ICP-MS. The total mass concentrations of fine and coarse particles were 33.23 and $20.66{\mu}g/m3$, respectively, and the total elemental concentrations were 1.27, $1.71{\mu}g/m3$, occupying 3.8 and 8.3% of the total mass. Fe, Al, Ti were the most abundant elements in both fine and coarse particles, and the total Pb concentration was 84.55ng/m3, below the National standard. Enrichment factor for Sc, Cr, Cu, Zn, As, Se, Sn, Pb in fine particles were above 1,000. This indicates that the elements in fine particles are mainly from the anthropogenic sources including automobiles.

Paleoceanographic Investigation from the Calcareous Skeletons of the Pleistocene Seoguipo Formation, Cheju Island, Korea (제주도 플라이스토세 서귀포층에서 산출되는 석회질 화석을 이용한 고해양 학적 연구)

  • 우경식;정대교
    • 한국해양학회지
    • /
    • v.30 no.3
    • /
    • pp.216-226
    • /
    • 1995
  • Stable isotopic and elemental compositions were analyzed for well- preserved calcareous skeletons (gastropods, pectenids, brachiopods, a scaphopod, and other bivalves) of the Pleistocene Seoguipo Formation from Cheju Island, Korea. Mineralogically and texturally, aragonitic and calcitic fossils still retain their original mineralogy and microstructure. High $\delta$$\^$18/O and $\delta$$\^$13/C contents indicate that the shells have not been altered by the post-burial diagenesis. Also, this is supported by high Na and Sr contents as well as low Mn and Fe compositions of the shells. Oxygen isotopic compositions of the well preserved fossils show that the organisms had lived under the lower paleotemperature or within the isotopically enriched paleo-seawater during the deposition of the Seoguipo Formation. This result strongly implies that the Seoguipo Formation was deposited during a glacial period. The paleotemperature variation throughout the sequence during the deposition of the Sewguipo Formation was negligible.

  • PDF

Measurement of Oxygen Isotope Ratio in Water Vapor by using Tunable Diode Laser Absorption Spectroscopy(TDLAS) - I (다이오드레이저 흡수분광법을 이용한 수증기의 산소 동위원소 성분비 측펑 - I)

  • Jung, Do-Young;Park, Sange-On;Kim, Jae-Woo;Ko, Kwang-Hoon;Im, Kwon;Jung, Eui-Chang;Kim, Chul-Joong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.200-201
    • /
    • 2003
  • 여러 가지 원소의 동위원소 성분 분석은 생물학, 화학, 환경학, 연대학, 기후학 연구에 있어서 중요한 정보를 제공하는 유용한 수단이다. 그 중에서도 수소, 산소, 그리고 탄소 동위원소 성분비의 정밀한 측정은 지구의 기후 변화 연구 등에 필수적인 수단이며, 가깝게는 식음료의 원산지 및 품질 확인에 이르기까지 다양하게 응용되고 있다 대표적으로 활용되고 있는 예를 보면 다음과 같다. 1. Authenticity Control and Detection of Adulteration: 쥬스류에 첨가제를 사용했는지의 여부를 확인할 수 있고, 포도주의 진품 여부를 확인할 수 있으며 원산지 확인도 가능하다. (중략)

  • PDF

First GC-IRMS in Korea and Its Application Fields (국내 최초로 도입된 GC-IRMS와 응용분야 소개)

  • Shin, Woo-Jin;Lee, Kwang-Sik;Ko, Kyung-Seok
    • Economic and Environmental Geology
    • /
    • v.40 no.5
    • /
    • pp.699-703
    • /
    • 2007
  • Compound-specific isotope analysis (CSIA) by isotope ratio mass spectrometer (IRMS) interfaced with gas chromatography (GC) is a state of the art analytical technique for stable isotopes in earth sciences, environmental sciences and forensics. Since early 1990s, GC-IRMS has been widely used to investigate the authenticity of food in forensic science and to trace the sources of organic contaminants in environmental science. In Korea, a GC-IRMS was firstly installed at the Korea Basic Science Institute (KBSI) in early 2005. In this study, we introduce the GC-IRMS of the KBSI shortly to stimulate various isotope-related researches of Korea, and report preliminary CSIA results for BTEX of different manufacturers.