• Title/Summary/Keyword: 성능중심

Search Result 2,661, Processing Time 0.033 seconds

A Study on the Performance of Cloud-based VDI Adoption: Comparing between IS administrators and business users (클라우드 기반 VDI 도입 성과에 관한 연구 - 시스템 관리자와 일반 사용자의 비교를 중심으로 -)

  • Kim, Il-Han;Kwon, Sun-Dong
    • Management & Information Systems Review
    • /
    • v.37 no.2
    • /
    • pp.149-167
    • /
    • 2018
  • The purpose of this study is to analyze the performance of Virtual Desktop Infrastructure(VDI) adoption. VDI performance was measured by IS manager (system quality, security, and managerial operation) and business user (usability, access, and user satisfaction). The survey questionnaires were developed for measuring VDI performance. 84 data samples were collected from the companies that had adopted cloud-based VDI. This research model was verified by Smart-PLS and SPSS. The research findings were as follows: First, the companies using VDI experienced actual performance, but they did not attain their expectation. Second, as results of comparing between IS managers and business users, IS administrators had considerably higher performance than business users, which indicates that there were big differences in performance perception among users. Compared with prior research such as technical trend, system construction, and performance improvement, this study has the following implications. First, by comparing the expected performance with the actual performance of the companies that have implemented and operating VDI, it was suggested how a company that wants to adopt VDI can manage the expectation level of VDI and achieve higher actual performance. Second, because the perception of VDI performance differs between business users and system managers, it is meaningful that a fair evaluation of VDI performance requires a balanced consideration of business users and system managers.

Performance Test of Hypocenter Determination Methods under the Assumption of Inaccurate Velocity Models: A case of surface microseismic monitoring (부정확한 속도 모델을 가정한 진원 결정 방법의 성능평가: 지표면 미소지진 모니터링 사례)

  • Woo, Jeong-Ung;Rhie, Junkee;Kang, Tae-Seob
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • The hypocenter distribution of microseismic events generated by hydraulic fracturing for shale gas development provides essential information for understanding characteristics of fracture network. In this study, we evaluate how inaccurate velocity models influence the inversion results of two widely used location programs, hypoellipse and hypoDD, which are developed based on an iterative linear inversion. We assume that 98 stations are densely located inside the circle with a radius of 4 km and 5 artificial hypocenter sets (S0 ~ S4) are located from the center of the network to the south with 1 km interval. Each hypocenter set contains 25 events placed on the plane. To quantify accuracies of the inversion results, we defined 6 parameters: difference between average hypocenters of assumed and inverted locations, $d_1$; ratio of assumed and inverted areas estimated by hypocenters, r; difference between dip of the reference plane and the best fitting plane for determined hypocenters, ${\theta}$; difference between strike of the reference plane and the best fitting plane for determined hypocenters, ${\phi}$; root-mean-square distance between hypocenters and the best fitting plane, $d_2$; root-mean-square error in horizontal direction on the best fitting plane, $d_3$. Synthetic travel times are calculated for the reference model having 1D layered structure and the inaccurate velocity model for the inversion is constructed by using normal distribution with standard deviations of 0.1, 0.2, and 0.3 km/s, respectively, with respect to the reference model. The parameters $d_1$, r, ${\theta}$, and $d_2$ show positive correlation with the level of velocity perturbations, but the others are not sensitive to the perturbations except S4, which is located at the outer boundary of the network. In cases of S0, S1, S2, and S3, hypoellipse and hypoDD provide similar results for $d_1$. However, for other parameters, hypoDD shows much better results and errors of locations can be reduced by about several meters regardless of the level of perturbations. In light of the purpose to understand the characteristics of hydraulic fracturing, $1{\sigma}$ error of velocity structure should be under 0.2 km/s in hypoellipse and 0.3 km/s in hypoDD.

User Centered Interface Design of Web-based Attention Testing Tools: Inhibition of Return(IOR) and Graphic UI (웹 기반 주의력 검사의 사용자 인터페이스 설계: 회귀억제 과제와 그래픽 UI를 중심으로)

  • Kwahk, Ji-Eun;Kwak, Ho-Wan
    • Korean Journal of Cognitive Science
    • /
    • v.19 no.4
    • /
    • pp.331-367
    • /
    • 2008
  • This study aims to validate a web-based neuropsychological testing tool developed by Kwak(2007) and to suggest solutions to potential problems that can deteriorate its validity. When it targets a wider range of subjects, a web-based neuropsychological testing tool is challenged by high drop-out rates, lack of motivation, lack of interactivity with the experimenter, fear of computer, etc. As a possible solution to these threats, this study aims to redesign the user interface of a web-based attention testing tool through three phases of study. In Study 1, an extensive analysis of Kwak's(2007) attention testing tool was conducted to identify potential usability problems. The Heuristic Walkthrough(HW) method was used by three usability experts to review various design features. As a result, many problems were found throughout the tool. The findings concluded that the design of instructions, user information survey forms, task screen, results screen, etc. did not conform to the needs of users and their tasks. In Study 2, 11 guidelines for the design of web-based attention testing tools were established based on the findings from Study 1. The guidelines were used to optimize the design and organization of the tool so that it fits to the user and task needs. The resulting new design alternative was then implemented as a working prototype using the JAVA programming language. In Study 3, a comparative study was conducted to demonstrate the excellence of the new design of attention testing tool(named graphic style tool) over the existing design(named text style tool). A total of 60 subjects participated in user testing sessions where their error frequency, error patterns, and subjective satisfaction were measured through performance observation and questionnaires. Through the task performance measurement, a number of user errors in various types were observed in the existing text style tool. The questionnaire results were also in support of the new graphic style tool, users rated the new graphic style tool higher than the existing text style tool in terms of overall satisfaction, screen design, terms and system information, ease of learning, and system performance.

  • PDF

EFFECTS OF $INTERFERON-\gamma$ ON COLLAGEN AND FIBRONECTIN SYNTHESIS IN PRIMARY CULTURED PERIODONTAL LIGAMENT CELLS ($Interferon-\gamma$가 치주인대 세포의 Collagen 및 Fibronectin의 합성과 Alkaline Phosphatase 활성에 미치는 영향)

  • Kim, Gwang-Seok;Sung, Jae-Hyun;Choi, Je-Yong;Ryou, Hyun-Mo
    • The korean journal of orthodontics
    • /
    • v.23 no.2 s.41
    • /
    • pp.229-248
    • /
    • 1993
  • [ $Interferon-\gamma$ ] has been suggested as a cytokine of connective tissue stabilizer. In addition, it has also been demonstrated that this cytokine inhibited bone remodeling activities of the bone derived cells. In order to illuminate the effects of this cytokine in orthodontic force induced bone remodeling, it was administered to primary cultured periodontal ligament cells which have been known to have some osteoblast like characteristics. $Interferon-\gamma$ slightly decreased $[^3H]thymidine$ incorporation rate without a significant change in the total cellular DNA content up to 1000 U/ml, which meant these doses were not cytotoxic to the cell. Total protein synthesis was not influenced by various concentration of interferon-y whether it was determined by the $[^3H]proline$ incorporation rate or by the Lowry smethod. The effect of $interferon-\gamma$ on the individual protein was, however, differential, ie, it increased $[^3H]proline$ incorporation into the noncollagenous protein marginally, while it decreased $[^3H]proline$ incorporation into the collagen, so that it caused dose-dependent suppression of the relative collagen synthesis. On the contrary, the fibronectin synthesis determined by the ELISA was increased by 1000 U/ml of $interferon-\gamma$. The differential effects of the interferon-y on the collagen and fibronectin synthesis exhibited not only their protein level but also the steady state mRNA level. $Interferon-\gamma$ decreased steady state level of ${\alpha}1(I)$ procollagen mRNA significantly, while showing no significant changes in the fibronectin mRNA level. In addition to this, it was also found that indomethacin did not affect on the $interferon-\gamma$ induced collagen decrease in this cell, which meant prostaglandins were not involed in the process of $interferon-\gamma$ induced collagen decrease. So it can be concluded that the incubation of periodontal ligament cells with 1000 U/ml of $interferon-\gamma$ for 24 hr showed differential effects on the type I collagen and fibronectin gene expression. The decrease in relative collagen synthesis in the protein level was related with decrease in the steady state level of mRNA, while the increase in the fibronectin synthesis in the protein level was not correlated with the mRNA level.

  • PDF

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

Comparison of Actigraphic Performance between $ActiWatch^{(R)}$ and $SleepWatch^{(R)}$:Focused on Sleep Parameters Utilizing Nocturnal Polysomnography as the Standard (활동기록기($ActiWatch^{(R)}$$SleepWatch^{(R)}$) 성능 비교 연구:야간수면다원기록을 표준으로 한 수면변인을 중심으로)

  • Shin, Hong-Beom;Lee, Ju-Young;Lee, Yu-Jin;Kim, Kwang-Jin;Lee, Eun-Young;Han, Jong-Hee;Im, Mee-Hyang;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.12 no.1
    • /
    • pp.27-31
    • /
    • 2005
  • Objectives: We attempted to compare the performance of 2 commercially available actigraphies with focus on sleep parameters, using polysomnography as standard comparison tool. Methods: Fourteen normal volunteers (5 males and 9 females, mean age of $28{\pm}4.6\;years$) participated in this study. All the participants went through one night of polysomnography, simultaneously wearing 2 different kinds of actigraphies on each wrist. Polysomnographic and actigraphic data were stored, downloaded, and processed according to standard protocols and then statistically compared. Results: Both $ActiWatch^{(R)}$ and $SleepWatch^{(R)}$ tended to overestimate the total sleep time, compared to the polysomnography. $SleepWatch^{(R)}$ tended to underestimate the sleep latency. The two actigraphs and the polysomnograph did not show significant difference of sleep efficiency, when compared with one another. In addition, all of the sleep parameters from the instruments showed linear correlations except in $SleepWatch^{(R)}'s$ sleep latency. The sleep parameters from the two actigraphs did not show much noteworthy difference, and linear relationships were found between the sleep parameters from the two actigraphs. There was no significant distinction in the results of the two different actigraphs. Conclusion: The results of two actigraphies can be used interchangeably since the sleep parameters of the two different actigraphies do not show significant differences statistically. Overall, it is not legitimate to use actigraphy as a substitute for polysomnography. However, since sleep parameters except sleep latency show linear correlations, actigraphy might possibly be used to follow up patients after polysomnography.

  • PDF

EARLY DETECTION OF INITIAL DENTAL CARIES USING A $DIFOTI^{TM}$ (Digital Imaging Fiber-Optic Trans-illumination을 이용한 초기 법랑질 우식병소의 조기 진단)

  • Yeom, Hae-Woong;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.587-597
    • /
    • 2004
  • Over the past 20 years, great strides have been made in research regarding the mechanisms involved in the progression of carious lesions, but new equipment and research tools need to be developed to continue these advancements in caries research. Various methods have been applied to reduce the incidence of carious lesions, which have led to a significant decrease in the number of occlusal caries, but a concurrent increase in the proportion of proximal carious lesions. New diagnostic equipment has been developed to detect early stage carious lesions, and these have demonstrated excellent laboratory results and show promise in clinical applications. The research presented here examines the efficacy of the newly developed $DIFOTI^{TM}$ system in detecting proximal carious lesions compared to traditional intraoral exam and bitewing radiography, possible problems or deficiencies of using the system in clinic, possible improvements that can be made to the system, and the efficacy of detecting early, reversible carious lesions that can be remineralized by preventative fluoride applications. The subject pool consisted of 23 grammer school age patients just prior to entering the mixed dentition phase. Each patient was given a thorough oral examination, radiographic examination consisting of bitewing radiographs of the posterior teeth, and $DIFOTI^{TM}$ examination of the anterior and posterior teeth. Each examination was carried out two times by two examiners, and the data were statistically analyzed. The results are as follows: 1. The mean alpha value of reliability test of the visual oral examination was as follows; occlusal surface was 0.8470. mesial surface was 0.6430, distal surface was 0.5727. lingual surface was 0.2807 and distal surface was 0.2339. When the examination was limited to posterior teeth, the mean alpha value was as follows; occlusal surface was 0.8577, distal surface was 0.8211, lingual surface was 0.7728, buccal surface was 0.7152 and mesial surface was 0.6782. 2. The alpha value of reliability test of the radiographic analysis of carious lesions of the occlusal, mesial, and distal surfaces was 0.8500. 3. The alpha value of reliability test of the $DIFOTI^{TM}$ diagnostic analysis of carious lesions of the occlusal, buccal, lingual, mesial, and distal surfaces was determined to be 0.7917. 4. The $DIFOTI^{TM}$ diagnostic system was found to be the most accurate means of detecting occlusal, buccal, and lingual surface carious lesions (p<0.05), while mesial and distal proximal carious lesions were most accurately assessed using bitewing radiography (p<0.05).

  • PDF

Estimation and Mapping of Soil Organic Matter using Visible-Near Infrared Spectroscopy (분광학을 이용한 토양 유기물 추정 및 분포도 작성)

  • Choe, Eun-Young;Hong, Suk-Young;Kim, Yi-Hyun;Zhang, Yong-Seon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.6
    • /
    • pp.968-974
    • /
    • 2010
  • We assessed the feasibility of discrete wavelet transform (DWT) applied for the spectral processing to enhance the estimation performance quality of soil organic matters using visible-near infrared spectra and mapped their distribution via block Kriging model. Continuum-removal and $1^{st}$ derivative transform as well as Haar and Daubechies DWT were used to enhance spectral variation in terms of soil organic matter contents and those spectra were put into the PLSR (Partial Least Squares Regression) model. Estimation results using raw reflectance and transformed spectra showed similar quality with $R^2$ > 0.6 and RPD> 1.5. These values mean the approximation prediction on soil organic matter contents. The poor performance of estimation using DWT spectra might be caused by coarser approximation of DWT which not enough to express spectral variation based on soil organic matter contents. The distribution maps of soil organic matter were drawn via a spatial information model, Kriging. Organic contents of soil samples made Gaussian distribution centered at around 20 g $kg^{-1}$ and the values in the map were distributed with similar patterns. The estimated organic matter contents had similar distribution to the measured values even though some parts of estimated value map showed slightly higher. If the estimation quality is improved more, estimation model and mapping using spectroscopy may be applied in global soil mapping, soil classification, and remote sensing data analysis as a rapid and cost-effective method.

A review on the design requirement of temperature in high-level nuclear waste disposal system: based on bentonite buffer (고준위폐기물처분시스템 설계 제한온도 설정에 관한 기술현황 분석: 벤토나이트 완충재를 중심으로)

  • Kim, Jin-Seop;Cho, Won-Jin;Park, Seunghun;Kim, Geon-Young;Baik, Min-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.5
    • /
    • pp.587-609
    • /
    • 2019
  • Short-and long-term stabilities of bentonite, favored material as buffer in geological repositories for high-level waste were reviewed in this paper in addition to alternative design concepts of buffer to mitigate the thermal load from decay heat of SF (Spent Fuel) and further increase the disposal efficiency. It is generally reported that the irreversible changes in structure, hydraulic behavior, and swelling capacity are produced due to temperature increase and vapor flow between $150{\sim}250^{\circ}C$. Provided that the maximum temperature of bentonite is less than $150^{\circ}C$, however, the effects of temperature on the material, structural, and mineralogical stability seems to be minor. The maximum temperature in disposal system will constrain and determine the amount of waste to be disposed per unit area and be regarded as an important design parameter influencing the availability of disposal site. Thus, it is necessary to identify the effects of high temperature on the performance of buffer and allow for the thermal constraint greater than $100^{\circ}C$. In addition, the development of high-performance EBS (Engineered Barrier System) such as composite bentonite buffer mixed with graphite or silica and multi-layered buffer (i.e., highly thermal-conductive layer or insulating layer) should be taken into account to enhance the disposal efficiency in parallel with the development of multilayer repository. This will contribute to increase of reliability and securing the acceptance of the people with regard to a high-level waste disposal.

Truncation Artifact Reduction Using Weighted Normalization Method in Prototype R/F Chest Digital Tomosynthesis (CDT) System (프로토타입 R/F 흉부 디지털 단층영상합성장치 시스템에서 잘림 아티팩트 감소를 위한 가중 정규화 접근법에 대한 연구)

  • Son, Junyoung;Choi, Sunghoon;Lee, Donghoon;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.111-118
    • /
    • 2019
  • Chest digital tomosynthesis has become a practical imaging modality because it can solve the problem of anatomy overlapping in conventional chest radiography. However, because of both limited scan angle and finite-size detector, a portion of chest cannot be represented in some or all of the projection. These bring a discontinuity in intensity across the field of view boundaries in the reconstructed slices, which we refer to as the truncation artifacts. The purpose of this study was to reduce truncation artifacts using a weighted normalization approach and to investigate the performance of this approach for our prototype chest digital tomosynthesis system. The system source-to-image distance was 1100 mm, and the center of rotation of X-ray source was located on 100 mm above the detector surface. After obtaining 41 projection views with ${\pm}20^{\circ}$ degrees, tomosynthesis slices were reconstructed with the filtered back projection algorithm. For quantitative evaluation, peak signal to noise ratio and structure similarity index values were evaluated after reconstructing reference image using simulation, and mean value of specific direction values was evaluated using real data. Simulation results showed that the peak signal to noise ratio and structure similarity index was improved respectively. In the case of the experimental results showed that the effect of artifact in the mean value of specific direction of the reconstructed image was reduced. In conclusion, the weighted normalization method improves the quality of image by reducing truncation artifacts. These results suggested that weighted normalization method could improve the image quality of chest digital tomosynthesis.