• Title/Summary/Keyword: 성과측정지표

Search Result 588, Processing Time 0.031 seconds

Prediction of Seasonal Nitrate Concentration in Springs on the Southern Slope of Jeju Island using Multiple Linear Regression of Geographic Spatial Data (지리 공간 자료의 다중회귀분석을 이용한 제주도 남측사면 용천수의 시기별 질산성 질소 농도 예측)

  • Jung, Youn-Young;Koh, Dong-Chan;Kang, Bong-Rae;Ko, Kyung-Suk;Yu, Yong-Jae
    • Economic and Environmental Geology
    • /
    • v.44 no.2
    • /
    • pp.135-152
    • /
    • 2011
  • Nitrate concentrations in springs at the southern slope of Jeju Island were predicted using multiple linear regression (MLR) of spatial variables including hydrogeological parameters and land use characteristics. Springs showed wide range of nitrate concentrations from <0.02 to 86 mg/L with a mean of 20 mg/L. Spatial variables were generated for the circular buffer when the optimal buffer radius was assigned as 400 m. Selected regression models were tested using the p values and Durbin-Watson statistics. Explanatory variables were selected using the adjusted $R^2$, Cp (total squared error) and AIC (Akaike's Information Criterion), and significance. In addition, mutual linear relations between variables were also considered. Small portion of springs, usually <10% of total samples, were identified as outliers indicating limitations of MLR using circular buffers. Adjusted $R^2$ of the proposed models was improved from 0.75 to 0.87 when outliers were eliminated. In particular, the areal proportion of natural area had the greatest influence on the nitrate concentrations in springs. Among anthropogenic land uses, the influence of nitrate contamination is diminishing in the following order of orchard, residential area, and dry farmland. It is apparent quality of springs in the study area is likely to be controlled by land uses instead of hydrogeological parameters. Most of all, it is worth highlighting that the contamination susceptibility of springs is highly sensitive to nearby land uses, in particular, orchard.

Protective Effect of Antioxidants on the Reoxygenation Injury in Hypoxic Myocardium of Rat (저산소 심장의 산소 재공급에 따른 심근 손상에 있어서 항산화제의 보호 효과)

  • Yoon, Hyung-Ku;Lim, Jung-Kyoo;Kim, Myung-Suk
    • The Korean Journal of Pharmacology
    • /
    • v.24 no.1
    • /
    • pp.53-61
    • /
    • 1988
  • The effect of antioxidants on the myocardial cellular damage which occurs during reoxygenation of hypoxic myocardium was examined in isolated rat hearts. The roles of oxygen free radical and lipid peroxidation in reoxygenation injury of myocardium were also investigated. In Langenorff preparation of isolated rat heart, which was made hypoxic by perfusion with the substrate free, hypoxic cardioplegic solution ($37^{\circ}C$, 90 min), the release of cytosolic enzymes (creatine phosphokinase, lactic dehydrogenase) and a lipid peroxidation product, malondialdehyde into the coronary effluent were abruptly increased by reoxygenation. The release of enzymes was closely parallel to that of MDA. These increases of enzymes and lipid peroxidation product were suppressed to various degrees in the presence of scavengers of superoxide anion (superoxide dismutase, 10,000 U), hydrogen peroxide (catalase, 25,000 U) and hydroxyl radical (dimethyl sulfoxide, 10%). A natural antioxidant, ${\alpha}-tocopherol$(4.5 uM) and a synthetic one, butylated hydroxytoluene (2 uM) suppressed the release of cytosolic enzymes with the concomittent reduction of lipid peroxidation as measured by malondialdehyde release into the coronary effluent. These effects of antioxidants were dose dependent, and were more pronounced when the antioxidants were administered throughout hypoxic and reoxygenation periods than given during reoxygenation period only. These results suggest that cytotoxic oxygen free radicals produced in the myocardium during reoxygenation may be responsible fur the myocardial cellular injury by enhancing the lipid peroxidation of cellular membranes. Furthermore, the antioxidants may exert protective effect against reoxygenation damage of hypoxic myocardium through the inhibition of lipid peroxidation reaction.

  • PDF

An Empirical Study on Korean Stock Market using Firm Characteristic Model (한국주식시장에서 기업특성모형 적용에 관한 실증연구)

  • Kim, Soo-Kyung;Park, Jong-Hae;Byun, Young-Tae;Kim, Tae-Hyuk
    • Management & Information Systems Review
    • /
    • v.29 no.2
    • /
    • pp.1-25
    • /
    • 2010
  • This study attempted to empirically test the determinants of stock returns in Korean stock market applying multi-factor model proposed by Haugen and Baker(1996). Regression models were developed using 16 variables related to liquidity, risk, historical price, price level, and profitability as independent variables and 690 stock monthly returns as dependent variable. For the statistical analysis, the data were collected from the Kis Value database and the tests of forecasting power in this study minimized various possible bias discussed in the literature as possible. The statistical results indicated that: 1) Liquidity, one-month excess return, three-month excess return, PER, ROE, and volatility of total return affect stock returns simultaneously. 2) Liquidity, one-month excess return, three-month excess return, six-month excess return, PSR, PBR, ROE, and EPS have an antecedent influence on stock returns. Meanwhile, realized returns of decile portfolios increase in proportion to predicted returns. This results supported previous study by Haugen and Baker(1996) and indicated that firm-characteristic model can better predict stock returns than CAPM. 3) The firm-characteristic model has better predictive power than Fama-French three-factor model, which indicates that a portfolio constructed based on this model can achieve excess return. This study found that expected return factor models are accurate, which is consistent with other countries' results. There exists a surprising degree of commonality in the factors that are most important in determining the expected returns among different stocks.

  • PDF

A Prediction Model for Removal of Non-point Source Pollutant Considering Clogging Effect of Sand Filter Layers for Rainwater Recycling (빗물 재활용을 위한 모래 정화층의 폐색특성을 고려한 비점오염원 제거 예측 모델 연구)

  • Ahn, Jaeyoon;Lee, Dongseop;Han, Shinin;Jung, Youngwook;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.6
    • /
    • pp.23-39
    • /
    • 2014
  • An artificial rainwater reservoir installed in urban areas for recycling rainwater is an eco-friendly facility for reducing storm water effluence. However, in order to recycle the rainwater directly, the artificial rainwater reservoir requires an auxiliary system that can remove non-point source pollutants included in the initial rainfall of urban area. Therefore, the conventional soil filtration technology is adopted to capture non-point source pollutants in an economical and efficient way in the purification system of artificial rainwater reservoirs. In order to satisfy such a demand, clogging characteristics of the sand filter layers with different grain-size distributions were studied with real non-point source pollutants. For this, a series of lab-scale chamber tests were conducted to make a prediction model for removal of non-point source pollutants, based on the clogging theory. The laboratory chamber experiments were carried out by permeating two types of artificially contaminated water through five different types of sand filter layers with different grain-size distributions. The two artificial contaminated waters were made by fine marine-clay particles and real non-point source pollutants collected from motorcar roads of Seoul, Korea. In the laboratory chamber experiments, the concentrations of the artificial contaminated water were measured in terms of TSS (Total Suspended Solids) and COD (Chemical Oxygen Demand) and compared with each other to evaluate the performance of sand filter layers. In addition, the accumulated weight of pollutant particles clogged in the sand filter layers was estimated. This paper suggests a prediction model for removal of non-point source pollutants with theoretical consideration of the physical characteristics such as the grain-size distribution and composition, and change in the hydraulic conductivity and porosity of sand filter layers. The lumped parameter ${\theta}$ related with the clogging property was estimated by comparing the accumulated weight of pollutant particles obtained from the laboratory chamber experiments and calculated from the prediction model based on the clogging theory. It is found that the lumped parameter ${\theta}$ has a significant influence on the amount of the pollutant particles clogged in the pores of sand filter layers. In conclusion, according to the clogging prediction model, a double-sand-filter layer consisting of two separate layers: the upper sand-filter layer with the effective particle size of 1.49 mm and the lower sand-filter layer with the effective particle size of 0.93 mm, is proposed as the optimum system for removing non-point source pollutants in the field-sized artificial rainwater reservoir.

Clinical Observation of Pleural Effusion (늑막염의 임상적 고찰)

  • Kim, Choon-Sup;Ju, Kee-Joong;Lee, Chang-Hwan;Park, Sung-Min;Shim, Young-Woong;Song, Kap-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.5
    • /
    • pp.584-594
    • /
    • 1993
  • Background: Among the respiratory diseases, there are a lot of cases of pleural effusion. The most common cause is tuberculosis. But the other cause such as lung malignancy is in an increasing tendency because of the development of diagnostic procedure, the decrease of the prevalence of the tuberculosis and the increase of the longevity. We need to know the accurate diagnosis as soon as possible for the correct therapy. Method: A clinical observation was made on 315 cases of pleural effusion seen at Pusan Adventist Hospital, from Jan, 1989 to Dec, 1992. For diagnostic procedure, thoracentesis, lymph node biopsy, bronchoscopy and percutaneous biopsy of the parietal pleura with Cope needle were performed. The following are parameters used in seperating the exudate from the transudate: pleural protein 3.0 g/dl, pleural protein/serum protein ratio 0.5, pleural LDH 200 IU, pleural LDH/serum LDH ratio 0.6, pleural cholesterol 60 mg/dl and pleural cholesterol/serum cholesterol ratio 0.3. Each parameters were compared, and misclassified rate and diagnostic efficiency were calculated. Results: The most common cause of exudate pleurisy was tuberculosis (82.3%) and malignancy was next (12.2%). The chief complaints of pleural effusion were noted as dyspnea (58.7%), chest pain (54.9%), coughing (50.2%) and fever (36.2%). Location of pleural effusion was noted as right side (51.4%), left side (41.3%) and both sides (7.3%). Amount of pleural effusion of the chest X-ray was minimum (46.8%), moderate (40.5%) and maximum (12.7%). Misclassified rates for each parameters in seperating the exudates from the transudates were as follows; protein: 5.2%, pleural protein/serum protein:7.6%, LDH: 13.9%, pleural LDH/serum LDH: 6.9%, cholesterol: 8.0%, pleural cholesterol/serum cholesterol: 5.6%. On the pleural biopsy, the tuberculosis granuloma was 60.8%, malignancy was 13.6%, infection was 2.3% and nonspecific inflammatory reaction was 23.3%. Conclusion: on the basis of the above results, the most common cause of exudative pleurisy was tuberculosis. We think that the plerual cholesterol/serum cholesterol ratio is the most useful supportive parameter in separating the exudates from the transudates. For accurate diagnosis, the pleural biopsy is the first procedure and repeated pleural biopsy of nonspedcific inflammatory reaction is required.

  • PDF

Improvement of Analytical Method for Total Polysaccharides in Aloe vera Gel (알로에 베라(Aloe vera) 겔 중 총 다당체 시험법 개선)

  • Lee, Young-Joo;Kim, Yun-Je;Leem, Dong-Gil;Yoon, Tae-Hyung;Shin, Ji-Eun;Yoon, Chang-Yong;Kim, Jung-Hoon;Park, Mi-Sun;Kang, Tae-Seok;Jeong, Ja-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.3
    • /
    • pp.271-276
    • /
    • 2012
  • This study intented to standardize the method for total polysaccharide, which is a functional marker for aloe vera gel in Korea. We used four lyophilized raw materials and commercial aloe gel products, certified as Health Functional Food by Korea Food and Drug Administration, including powder, solution, jelly, tablet and capsule, to optimize the analytical condition of dialysis and phenol-sulfuric acid reaction in polysaccharide analysis. The optimal conditions for polysaccharide analysis included 1 L water for dialysis and change 3 times for 24hr against 25 mL prepared sample solution. Validation test showed lower than 5% of coefficient of variation(CV) in intra-, interday validation in lyophilized raw materials and 4 types of commercial products. In inter-person and inter-laboratory validation with 4 persons from 4 different laboratories, CV(%) were 5.50 and 6.64 respectively. The linearity of polysaccharide analysis was assessed using 5 serial concentration of lyophilized raw materials(0.1, 0.2, 0.3, 0.4, 0.5%(w/v)). The results showed $R^2{\geq}0.995$ of high linearity. In the commercial aloe vera gel products, the results of reproductivity showed lower than 7.08% and revealed that the standardized method from this study ensured high precision for polysaccharide analysis.

The Role of Pulmonary Capillary Pressure in the Oxygen Free Radical-Induced Acute Lung Injury (산소기에 의한 급성 폐손상에서 폐모세혈관압의 역할에 관한 연구)

  • Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.6
    • /
    • pp.474-483
    • /
    • 1992
  • Background: Regardless of its causes, acute lung injury is characterized pathophysiologically by increased pulmonary arterial pressure and the protein-rich edema. Many inflammatory mediators are known to be involved in the pathogenesis of acute lung injury, including oxygen free radicals (OFR). But the changes in pulmonary capillary pressure in the OFR-induced acute lung injury is not clear. While the pulmonary edema characterized by the movement of fluid and solutes is dependent on the pressure gradient and the alveolar-capillary permeability, the role of pulmonary capillary pressure in the development of pulmonary edema is also not well understood. Method: Male Sprague-Dawley rats were divided into 5 groups: normal control (n=5), xanthine/xanthine oxidase (X/XO)-treated group (n=7), catalase-pretreated group (n=5), papaverine-pretreated group (n=7), and indomethacin-pretreated group (n=5). In isolated perfused rat lungs, the sequential changes in pulmonary arterial pressure, pulmonary capillary pressure by double occlusion method, and lung weight as a parameter of pulmonary edema were determined. Results: Pulmonary arterial pressure and pulmonary capillary pressure were increased by X/XO. This increase was significantly attenuated by catalase and papaverine, but indomethacin did not prevent the X/XO-induced increase. Lung weight gain was also observed by X/XO perfusion. It was prevented by catalase. Papaverine did not completely block the increase, but significantly delayed the onset. Indomethacin had no effect on the increase in lung weight. Conclusion: These data suggest that increased pulmonary capillary pressure by OFR may aggravate pulmonary edema in the presence of increased alveolar-capillary permeability and this may not be mediated by cyclooxygenase metabolites.

  • PDF

Interlaboratory Comparison of Blood Lead Determination in Some Occupational Health Laboratories in Korea (일부 산업보건기관들의 혈중연 분석치 비교)

  • Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.8-15
    • /
    • 1995
  • The reliable measurement of metal in biological media in human body is one of critical indicators for the proper evaluation of its toxic effect on human health. Recently in Korea the necessity of quality assurance of measurement in occupational health and occupational hygiene fields brought out regulatory quality control program. Lead is often used as a standard metal for the program in both fields of occupational health and hygiene. During last 20 years lead poisoning was prevalent in Korea and still is one of main heavy metal poisoning and the capability of the measurement of blood lead is one of prerequisites for institute of specialized occupational health in Korea. Furthermore blood lead is most important indicator to evaluate lead burden of human exposure to lead and the reliable and accurate analysis is most needed whenever possible. To evaluate the extent of the interlaboratory differences of blood lead measurement in several well-known institute specialized in occupational health in Korea, authors prepared 68 blood samples from two storage battery industries and all samples were divided into samples with 2 ml. One set of 68 samples were analyzed by authors's laboratory(Soonchunhyang University Institute of Industrial Medicine: SIIM) and 40 samples of other set were analyzed by C University Institute of Industrial Medicine(CIIM) and the rest 28 samples of other set were analyzed by Japanese institute(K Occupational Health Center:KOHC). Authors also prepared test bovine samples which were obtained from Japanese Federation of Occupational Health Organization (JFOHO) for quality control. Authors selected 2 other well-known occupational health laboratories and one laboratory specialized for instrumental analysis. A total of 6 laboratories joined the interlaboratory comparison of blood lead measurement and the results obtained were as follows: 1. There was no significant difference in average blood lead between SIIM and CIIM in different group of blood lead concentration, and the relative standard deviation of two laboratories was less than 3.0%. On the other hand, there was also no significant difference of average blood lead between SIIM and KOHC with relative standard deviation of 6.84% as maximum. 2. Taking less than 15% difference of mean or less than 6 ug/dl difference in below 40 ug/dl in whole blood as a criteria of agreement of measurement between two laboratories, agreement rates were 87.5%(35/40) and 78.6%(22/28) between SIIM and CIIM, SIIM and KOHC respectively. 3. The correlation of blood lead between SIIM and CIIM was 0.975 (p=0.0001) and the regression equation was SIIM = 2.19 + 0.9243 ClIM, whereas the correlation between SUM and KOHC was O.965(p=0.0001) with the equation of SIIM = 1.91 + 0.9794 KOHC. 4. Taking the reference value as a dependent variable and each of 6 laboratories's measurement value as a independent variable, the determination coefficient($R^2$) of simple regression equations of blood lead measurement for bovine test samples were very high($R^2>0.99$), and the regression coefficient(${\beta}$) was between 0.972 and 1.15 which indicated fairly good agreement of measurement results.

  • PDF