• Title/Summary/Keyword: 섬유 보강 콘크리트

Search Result 927, Processing Time 0.034 seconds

A Study of the Characteristic Changes of Self-Compacting Concrete with mixing shifted contents of Steel Fibers (섬유 변화량에 따른 고유동 자기충전 콘크리트의 특성변화에 관한 연구)

  • Lee, Keun-Su;Choi, Yeol;Lee, Jae-Ik;Jung, Woong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.243-244
    • /
    • 2009
  • Fibers reinforced concrete(FRC) has abilities to make up for brittleness fracture as one of the material characteristics of concrete. However, being mixed with steed fibers in concrete mixes could set off a "Fiber Ball". The Fiber ball formation could be one of the main reasons to decrease the quality of Fibers reinforced concrete. In order to eliminate the fiber ball formation and improve the deficient flowablitiy, The necessity of research for fiber reinforced self-compacting concrete(FRC-SCC) should be raised.

  • PDF

Mechanical Behavior of Plain and Steel Fiber Reinforced High Strengh Concrete Under Biaxial Compression (2축 압축을 받는 고강도 콘크리트 및 강섬유보강 고강도 콘크리트의 역학적 거동 특성)

  • Lim Dong-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.803-809
    • /
    • 2005
  • The purpose of this study is to investigate the mechanical characteristics of plain and steel fiber high strength concrete under uniaxial and biaxial loading condition. A number of plain and steel fiber high strength concrete cubes having 28 days compression strength of 82.7MPa(12,000 psi) were made and tested. Four principal compression stress ratios ($\sigma_2/\sigma_1$=0.00, 050, 0.75 and 1.00), and four fiber concentrations($V_f$ =0.0, 0.5, 1.0 and $1.5\%$) were selected as major test variables. From test results, it is shown that confinement stress in minor stress direction has pronounced effect on the strength and deformational behavior. Both of the stiffness and ultimate strength of the plain and fiber high strength concrete Increased. The maximum increase of ultimate strength occurred at biaxial stress ratio of 0.5($\sigma_2/\sigma_1=0.5$) in the plain high strength concrete and the value were recorded $30\%$ over than the strength under uniaxial condition. The failure modes of plain high strength concrete under uniaxial compression were shown as splitting type of failure but steel fiber concrete specimens under biaxial condition showed shear type failure. The values of elastic modulus were also examined higher than that from ACI and CEB expression under biaxial compression condition.

Flexural Strength Analysis of RC T-Beams Strengthened Using Fiber Sheets (섬유시트로 보강된 T형 철근콘크리트보의 휨 강도 해석)

  • Park, Tae-Hyo;Lee, Gyu-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.234-245
    • /
    • 2003
  • Most of the concrete bridge structures are exposed to damage due to the excessive traffic loading and the aging of the structure. The damage of concrete causes the further deterioration of the function in the concrete structure due to corrosion of the reinforced bars and decohesion between the concrete and the reinforced bar. The quick rehabilitation of the damaged concrete structures has become of great importance in the concrete structural system in order to avoid the further deterioration of the structures. Recently fiber sheets are used for strengthening the damaged concrete structures due to its many advantages such as its durability, non-corrosive nature, low weight, ease of application, cost saving, control of crack propagation, strength to thickness ratio, high tensile strength, serviceability and aesthetic. However, the lack of analytical procedures for assessing the nominal moment capacity by the fiber sheet reinforcement leads to difficulties in the effective process of decisions of the factors in the strengthening procedure. In this work, flexural strengthening effects by fiber sheets bonded on bottom face of the member are studied for the reinforced concrete T beam. In addition, auxiliary flexural strengthening effects by U-type fiber sheets bonded on bottom and side faces of the member to prevent delamination of the bottom fiber sheet are theoretically investigated. The analytical solutions are compared with experimental results of several references to verify the proposed approach. It is shown that the good agreements between the predicted results and experimental data are obtained.

Moisture Sensitivity and Aging Effects of Recycled Wastepaper fiber Cement Composites (폐지섬유보강 시멘트 복합체의 수분민감성 및 열화특성)

  • 원종필;배동인;박찬기;박종영
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.2
    • /
    • pp.148-155
    • /
    • 2002
  • This research investigates the moisture and aging effects of wastepaper fiber-cement composites. Wastepaper fibers is obtained by a dry process. Wastepaper fiber-cement composites was manufactured by the hatscheck process. The effects of moisture and aging on the performance of wastepaper fiber-cement composites were investigated through accelerated laboratory tests simulating the effects of moisture sensitivity and wet-dry cycles as well as freeze-thaw cycles and long-term drying. They were shown to possess acceptable moisture and aging performance compared with virgin fiber cement composites.

Theoretical Assessment of Reinforced Steel Fibrous Concrete Beam Equivalent to Conventional RC Beam (일반 RC보와 동등한 강섬유 보강 철근콘크리트 보의 이론적 산정)

  • 이차돈;윤여천
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.1
    • /
    • pp.195-206
    • /
    • 1997
  • 비선형 layered 유한요소법과 비선형 프로그래밍 기법에 의하여 주어진 기존의 철근콘크리트 보의 휨강도 및 연성을 근사하게 나타낼 수 있는 강섬유고강 철근콘크리트 보(Reinforced Steel Fibrous Concrete Beam : RSFC Beam)의 인장 및 압축철근량, 강섬유의 혼입률 등을 산정하였다. 개발된 모델을 이용하여 콘트리트의 압축강도 및 철근비가 서로 다른 일반 철근콘크리트 보에 있어서 강섬유보강 콘크리트를 사용할 경우, 기존 철근을대체하는 강섬유의 량과 또한 이로 인한 인장 \ulcorner 압축 철근량의 변화량을 조사하였다. 기존 문헌에 나타난 강섬유보강 콘크리트보의 전간강도식을 이용하여 일반 철근콘크리트보와 비교하여 강섬유보강 철근콘크리트 보에서 증가될 수 있는 스터럽의 간격을 산정하였다.

Structural Performance Evaluation of Reinforced Concrete Beams with Externally Bonded FRP Sheets (RC 구조물에 적용된 부착식 휨보강공법의 보강성능 평가)

  • Hong, Geon-Ho;Shin, Yeong-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.78-86
    • /
    • 2003
  • Reinforced concrete beams are often retrofitted with various FRP composite sheets. This paper is focused on the comparison of structural performance of various FRP sheets and proposal of the retrofitting design formula. Effects of the FRP kinds(AFRP, GFRP, CFRP) and the reinforcing steel ratio on behavior of the retrofitting beams are tested and analyzed with particular emphasis on the maximum load capacity, stiffness, and ductility. The experimental work included 4 point flexural testing of 3.2m span reinforced concrete beams with bonded external reinforcements. The results show that the difference of FRP kinds is not large and the flexural load capacity is mainly affected by stiffness of the retrofitting materials. This paper also proposes the design formula on the retrofitting reinforced concrete flexural members and checks with this experimantal work and previous research results.

A Study on the Shear Properties of Steel Fiber Reinforced Concrete Deep Beams (강섬유보강(鋼纖維補强)콘크리트 Deep Beam의 전단특성(剪斷特性)에 관한 연구(硏究))

  • Moon, Je Kil;Hong, Ik Pyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.75-87
    • /
    • 1993
  • Four series of fiber reinforced concrete deep beams without shear reinforcement were tested to determine their cracking shear strengths and ultimate shear capacities. Results of tests on 20 reinforced concrete deep beams (including 16 containing steel fibers) are reported. Three parameters were varied in the study, namely, the concrete compressive strength, volume fraction of fibers, and the shear span to depth ratio. The effects of fiber incorporation on failure modes, deflections. strains, cracking shear strength, and ultimate shear strength have been examined. Resistance to shear stresses have been found to be improved by the inclusion of fibers. Based on these investigations, a method of computing the shear stress of steel fiber reinforced concrete deep beam is suggested. The comparisons between computed values and experimentally observed values are shown to validate the proposed theoretical treatment.

  • PDF

Mechanical Property of Fiber Reinforced Concrete according to the Change of Curing Method (양생방법 변화에 따른 섬유보강콘크리트의 역학적 특성)

  • Kim, Chun-Ho;Kim, Nam-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.2
    • /
    • pp.67-73
    • /
    • 2016
  • When assessing crack initiation of fiber reinforced concrete, usually tensile strength or flexural strength is becomes indicator, but also depend on the curing effect take place during the production of specimen. In general, after conducting concrete specimen is cured by water at temperature $20{\pm}3^{\circ}C$ in laboratory, and accomplished the assessment of strength, but most of concrete structure is kept in drying condition after moist curing through the prescribed period. However, unlike these trends that technological advances have been made, influence of the difference of curing method on crack strength is not yet clear. Therefore, in this study, it is examined on the effect of curing methods affecting the mechanical property of fiber reinforced concrete, especially crack strength.

Applicability of Hyblid FRP Reinforcing Bar for Self-diagnosis of Concrete Fracture (콘크리트 파괴 자가진단을 위한 하이브리드 FRP 보강근의 적용 특성)

  • Park, Seok-Kyun;Kim, Dae-Hoon
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.439-445
    • /
    • 2006
  • For investigating self-diagnosis applicability, a method based on monitoring the changes in the electrical resistance of hybrid FRP(having electrical property) reinforced concrete has been tested. Then after examining change in the value of electrical resistance of carbon fiber in CFRP(non-hybrid type), CFGFRP and CFAFRP(hybrid type) before and after the occurrence of cracks and fracture in non-hybrid and hybrid FRP reinforced concrete at each flexural weight-stage, the correlations of each factors(the changes in electrical resistance and load as a function of strain, deflection) were analyzed. As the results, it is clarified that when the carbon fiber tows fracture, the electrical resistance of it increase largely, and afterwards hybrid FRP composites can be resist the load due to the presence of the reinforced fiber, for example, glass fiber or aramid fiber tows. Therefore, it can be recognized that hybrid FRP(including carbon fiber) reinforcing bar could be applied for self-diagnosis of fracture in reinforced FRP concrete fracture.

The Moment-Curvature Relationship of the Rectangular Ultra High Performance Fiber Reinforced Concrete Beam (초고강도 섬유보강 직사각형 콘크리트보의 모멘트-곡률 관계)

  • Han, Sang-Mook;Guo, Qing-Yong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.9-15
    • /
    • 2011
  • The flexural behavior of the UHPFRC rectangular beam which has 100 MPa, 140 MPa compressive strength were compared with that of the typical RPC rectangular beam which has same geometrical shape, prestressd force and 160 MPa compressive strength. UHPFRC beam was not reinforced at all and the variable of test is fraction of steel fiber, compressive strength of concrete, method of prestressing and ratio of prestressing bar. The behavior of UHPFRC beam was analysed by relationship of moment - curvature and load - deflection. Simple modeling of stress-strain of UHPFRC was proposed. Based on the proposed constituted, the flexural moment-curvature relationship was calculated and compared with experimental data on prestressed UHPFRC beams. Good agreement between calculated strengths and experimental data is obtained.