• Title/Summary/Keyword: 섬유보강 모르타르

Search Result 72, Processing Time 0.025 seconds

Material Properties of 3D Printed Mortars Produced with Synthetic Fibers and Biopolymers (합성섬유 및 바이오 폴리머를 혼입한 3D 프린팅 모르타르의 재료특성)

  • Hyo-Jung Kim;Byung-Jae Lee;Yun-Yong Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.4
    • /
    • pp.78-85
    • /
    • 2023
  • In this study, synthetic fibers were applied to reduce shrinkage cracks that may occur in mortar produced by 3D printer. We used a biopolymer in powder form made from cactus stem (CS) as an admixture. The material properties of 3D printed mortar were experimentally evaluated. Replacing methylcellulose(MC) with 10% CS increases compressive strength by 9.84-23.92% regardless of the casting method. In addition, regardless of the casting method, shrinkage change, freeze-thaw resistance, and crack resistance are more effective than Plain. Incorporation of CS increases the polysaccharide macromolecular structure and improves durability. Mortars reinforced with synthetic fibers do not affect compressive strength and freeze-thaw. It is also effective for shrink deformation and crack resistance. Incorporating CS and fibers from 3D-printed mortar was found to be effective for durability and crack resistance.

A Study on Improvement of Seismic Performance of High Strength Reinforced Concrete Interior Beam-Column Joints using High Ductile Fiber-Reinforced Mortar (고인성섬유 복합모르타르를 활용한 고강도 철근콘크리트 내부 보-기둥 접합부의 내진성능 개선 연구)

  • Ha, Gee-Joo;Hong, Kun-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.753-760
    • /
    • 2012
  • In this study, experimental research was carried out to evaluate and improve the constructability and seismic performance of high strength R/C interior beam-column joints regions, with or without the shear reinforcement, using high ductile fiber-reinforced mortar. Six specimens of retrofitted the beam-column joint regions using high ductile fiber-reinforced mortar are constructed and tested for their retrofit performances. Specimens designed by retrofitting the interior beam-column joint regions (IJNS series) of existing reinforced concrete building showed a stable mode of failure and an increase in load-carrying capacity due to the enhancement of crack dispersion by fiber bridging from using new high ductile materials for retrofitting. Specimens of IJNS series, designed by the retrofitting of high ductile fiber-reinforced mortar in beam-column joint regions increased its maximum load carrying capacity by 96~102.8% and its energy dissipation capacity by 0.99~1.11 folds when compared to standard specimen of SIJC with a displacement ductility of 5.

High Ductile Fiber Reinforced Concrete with Micro Fibers (마이크로 섬유를 혼입한 고인성 섬유 보강 콘크리트)

  • Shin, Kyung-Joon;Lee, Seong-Cheol;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.92-98
    • /
    • 2019
  • In general, high strength and high performance fiber reinforced cement composites exclude coarse aggregates basically in order to have homogeneous distributions of material properties. However, these fiber-reinforced cement mortar without coarse aggregate have a tenancy that the modulus of elasticity is low and the unit weight of cement is high, resulting in low economic efficiency. Therefore, in this study, the development of high ductile fiber - reinforced concrete was conducted, which has the adequate level of coarse aggregate but still retains the high flexural toughness and strength and also has the crack - distributing performance. Experimental study was carried out by using the amount of coarse aggregate as an experimental parameter. The results showed that the best flexural toughness and crack dispersion characteristics was obtained when the coarse aggregate was added at 25% by weight of the fine aggregate to the typical mixtures of high ductile cement mortar. PVA fiber was effective in crack distribution and ductility enhancement, and steel fiber was effective in strengthening flexural strength rather than crack distribution.

Evaluation of Impact Resistance Performance of Fiber Reinforced Preplace Grout Mortar (섬유를 혼입한 프리플레이스 모르타르의 내충격 성능 평가)

  • Lee, Sang-Gyu;Kim, Gyu-Yong;Choe, Gyeong-Cheol;Kim, Hong-Seop;Lee, Young-Wook;Hwang, Eui-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.65-66
    • /
    • 2015
  • In this study, it evaluate mecahnical performance and impact resistance performance of fiber reinforced concrete, fiber reinforced mortar and preplace grout mortar. steel fiber, nylon fiber and polypropylene fiber are reinforced 1vol.% 2vol.% 10vol.% by each fiber type. It evaluate impact resistance performance to use projectile 10mm of 400m/s velocity. As a result, mechnical performance and impact resistance performance of fiber reinforced preplace grout mortar are improved a lot by 10% fiber reinforced ratio.

  • PDF

Evaluation of Crack Resistant Performance in Cement Mortar with Steel Fiber and CSA Expansion Admixture (CSA 팽창재를 혼입한 강섬유 보강 모르타르의 균열 저항성능 평가)

  • Ahn, Jung-Kil;Park, Ki-Tae;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.125-132
    • /
    • 2014
  • Steel fiber is a effective composite for crack resistance and improve structural performance under tensile loading. This study presents an evaluation of crack resistance and structural performance in cement mortar with steel fiber and expansion agent through internal chemical prestressing. For this work, cement mortar samples with 10% replacement of cement binder with CSA (Calcium-Sulfo-Aluminate) expansion agent and 1% volume ratio of steel fiber are prepared. Including basic mechanical properties, initial cracking load and fracture energy are evaluated in cement mortar beam with notch. Initial cracking load and fracture energy in cement mortar with CSA and steel fiber increase by 1.75 and 1.41~1.53 times compared with those in cement mortar with steel fiber. With optimum mix design for steel fiber and CSA expansive agent, the composite with chemical prestressing can be applied to various members and effectively improve crack resistance to external loading.

A Study on the Rheology Properties for Development of Sprayed High Performance Fiber Reinforced Cementitious Composites for Protection and Blast Resistant (방호·방폭용 뿜칠형 고성능 섬유보강 시멘트 복합재료 개발을 위한 레올로지 특성 연구)

  • Choi, Yun-Wang;Choi, Byung-Keol;Park, Man-Seok;Sung, Don
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.3
    • /
    • pp.188-195
    • /
    • 2014
  • This paper was evaluated the rheology properties according to each step of paste, mortar and HPFRCC as a part of the basic study to development of sprayed high performance fiber reinforced cementitious composites(HPFRCC) for protection and blast resistant. Rheology test results in step of paste, in case of GGBFs and FA, it showed that the plastic viscosity and yield stress reduced gradually according to the increase of mixing rate, and in case of SF, the plastic viscosity and yield stress increased radically starting from the mixing rate of 10%. Rheology test results in step of mortar, type of aggregates, it showed that particle shape and grading of aggregate is influence on plastic viscosity and yield stress, and change of volume ratio is influence on plastic viscosity than yield stress. Fluidity and rheology test results in step of HPFRCC, if after a fiber mixed, it showed that viscosity agent is more effective to improve the fluidity and fiber dispersion than superplasticizer.

A Study on Improvement of Seismic Performance of High Strength Reinforced Concrete Interior Beam-Column Joints Using High Ductile Fiber-Reinforced Mortar and Advanced Reinforcing Detailings (고인성섬유 복합 모르타르 및 고성능 배근상세를 활용한 고강도 철근콘크리트 내부 보-기둥 접합부의 내진성능 개선 연구)

  • Ha, Gee-Joo;Yi, Dong-Ryul;Hong, Kun-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.2
    • /
    • pp.233-240
    • /
    • 2013
  • In this study, experimental research was carried out to evaluate and improve the seismic performance of high strength R/C interior beam-column joints regions using advanced reinforcing detailings and high ductile fiber-reinforced mortar. Five specimens of retrofitted the beam-column joint regions using advanced reinforcing detailings and high ductile fiber-reinforced mortar were constructed and tested for their retrofitring performances. Specimens designed by retrofitting the interior beam-column joint regions (IJIR series) of existing reinforced concrete building showed a stable mode of failure and an increase in load-carrying capacity. Specimens of IJIR series, designed by the retrofitting of advanced reinforcing detailings and high ductile fiber-reinforced mortar in reinforecd beam-column joint regions increased its maximum load carrying capacity by 114.2~123.5% and its energy dissipation capacity by 1.55~1.85 times in comparison with the standard specimen of SIJC with a displacement ductility of 5.

Evaluation of Crack Control and Permeability of Hydrophilic PVA fiber Reinforced Cement Composite (친수성 PVA 섬유보강 시멘트 복합체의 균열제어 및 투수성 평가)

  • Won Jing-Pil;Hwang Keum-Sik;Park Chan-Gi;Park Hae-Geun
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.3 s.81
    • /
    • pp.391-396
    • /
    • 2004
  • Plastic shrinkage crack occurs at the exposed surfaces of freshly placed concrete due to consolidation of the concrete mass and rapid evaporation of water from the surface. This so-called shrinkage crack is a major concern for concrete, especially for flat structures such as pavements, slabs for industrial factories and retaining walls. This study has been performed to obtain the plastic shrinkage and the permeability of hydrophilic poly vinyl alcohol(PVA) fiber reinforced mortar and concrete. Test results indicated that PVA fiber reinforced cement composite showed an ability to reduce the total crack area and the maximum crack width (as compared to plain and polypropylene fiber reinforced concrete). Also, according to the permeability test result, it was found that PVA fiber reinforced cement composite was more reducing than polypropylene fiber reinforced cement composite.

Bond Properties of Nonpolar Macro Synthetic Fiber in Cement Mortar with Maleic Anhydride Grafted Polypropylene Powder (무수말레인산이 그라프트된 폴리프로필렌 분말 첨가에 따른 시멘트 모르타르와 무극성 마크로 합성섬유의 부착 특성)

  • Lee, Jin-Hyung;Park, Chan-Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2A
    • /
    • pp.137-143
    • /
    • 2011
  • This study evaluated the effects of maleic anhydride grafted polypropylene powder (mPP) contents on the bond properties of cement mortar and nonpolar macro synthetic fibers (macro synthetic fiber). Dog-bone bond tests were performed to evaluate the bond performance of macro synthetic fiber in cement mortar with varying amounts of mPP (0%, 5%, 10%, 15%, 20%, 25%, 30% of cement weight). The bond properties (pullout behavior, pullout load and interface toughness) of macro synthetic fiber in cement mortar increased as the mPP contents was increased. The bond properties increased with the mPP contents. The microstructure of macro synthetic fiber surface was examined after the pullout test to analyze the frictional resistant force according to mPP contents during the pullout process of macro synthetic fiber in cement mortar. The scratched of macro synthetic fiber increased with the mPP contents.