• Title/Summary/Keyword: 섬유기기

Search Result 92, Processing Time 0.033 seconds

Evaluation of convergence Elasticity of Liver Fibroscan used measurement with Ultrasonography (초음파를 이용한 간 섬유화 스캔 검사의 융합 탄성도 측정 평가)

  • Kim, Min-Jeong;Han, Man-Seok;Jang, Jae-Uk
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.5
    • /
    • pp.79-85
    • /
    • 2017
  • The purpose of this research was to evaluate the clinical and the instrument of convergence utility of transient elastography (FibroScan(R):electromagnetic wave) in diagnosing and treating liver ailments through a comparison and an analysis between liver function blood test and transient elastography (FibroScan(R)) in patients with chronic hepatitis B virus infection. Of all the patients with chronic hepatitis B virus infection who visited clinic B in Daejeon City between July 1, 2015, and February 28, 2016, 75 who underwent a FibroScan(R) test were selected for this study. Their laboratory and liver function test results were compared for a correlation analysis before constructing an ROC (Receiver Operation Characteristic) curve. Aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels were 0.572 and 0.502, respectively, and showed highest correlation with fibrosis score, with statistical significance (p<0.000). Gamma glutamyltranspeptidase, total bilirubin, and alkaline phosphatase levels also showed relatively significant correlations in this order of sequence, while -fetoprotein and total protein levels did not show any statistically significant values. Albumin (-0.449) and platelet levels (-0.373) showed negative correlations with each other and no correlation with fibrosis score (p < 0.000). As liver fibrosis worsened, the accuracy of the ROC curve increased. At the F4 stage, which is the cirrhotic stage, the largest area under the curve was observed. FibroScan(R) showed significant correlation with the ALT (serum glutamic pyruvic transaminase) and AST (serum glutamic oxaloacetic transaminase) levels in the liver function test, which is a routine test for patients with chronic liver ailments. This implies that fibrosis correlates with liver inflammation severity.

Consumer needs of Digital Textile Printing in Clothing based on Digital Fashion System (디지털 패션 시스템 기반 디지털 텍스타일 프린팅 섬유제품 수요 경향)

  • Cho, Ha-Kyung;Kim, Eun-Kyoung
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2012.03a
    • /
    • pp.99-99
    • /
    • 2012
  • 소비자의 기호가 다양화되면서 다품종 소량생산에 따른 대량 맞춤화에 대한 관심이 높아지고 있으며, 1990년대 후반부터 급격히 확산되고 있는 인터넷의 발달 및 디지털 기기의 확산에 따라 인터넷을 기반으로 한 전자상거래 환경에서의 대량 맞춤화 프로세스는 최근 의류 분야에서 주요한 경향으로 받아들여지고 있다. 대량 맞춤화 의류 제품의 수요는 인터넷 등 IT 기술의 발달과 맞물려 최근 개인의 특성과 취향을 고려한 인터넷 맞춤서비스를 기반으로 증가추세에 있으며, CAD 등의 테크놀러지의 활용을 통하여 디자인, 패턴제작, 재단 등의 자동 시스템을 도입함으로써 그 영역을 확장하고 있다. 이에 발맞추어 국내에서는 '디지털 패션 시스템'을 통해 3차원 바디 스캔, 3차원 컴퓨터 그래픽스, 3차원 Simulation, DID, DTP, 맞춤주문형 제품의 대량 생산기술 등의 단위 기술이 기업단위로 활용되는 등 가상현실을 이용한 3차원 가상쇼핑 등을 포함하는 기술로서 차세대 섬유패션 산업의 창출에 기여하고 있다. 그 중, 디지털 텍스타일 프린팅은 디자인에서부터 날염까지 전체 공정을 컴퓨터로 처리하여 기존의 복잡한 날염 공정을 단축하여 다품종 소량생산이 가능한 날염 방식으로, 대량 맞춤형 프로세스를 지원하며, 프로슈머(prosumer)로서의 소비자가 직접 참여하여 그들의 욕구를 최대화 할 수 있는 소비자 만족을 극대화 시킬 수 있는 대량 맞춤화 프로세스 중 하나의 단계로 소비자의 수요 반영하는 요소로 작용하고 있다. 즉, 디지털 패션 시스템에서의 디지털 텍스타일 프린팅은 대량 맞춤형 의류 제품에 있어 소비자 만족도와 직결되는 요인으로 분석된다. 따라서, 본 연구에서는 디지털 패션 시스템 기반의 대량맞춤형 섬유제품 및 디지털 텍스타일 프린팅 적용 섬유제품에 대한 기초 평가 문항을 제시하고, 소비자 태도를 분석하여 제시하였다. 또한, 분석된 기초 소비자 태도를 반영하여, 디지털 패션 시스템 기반의 디지털 텍스타일 프린팅(Digital Textile Printing) 의류 제품의 선호도, 인지도, 수요도 및 구입의향을 분석하여 최종적으로 디지털 패션 시스템에 적용된 디지털 텍스타일 프린팅 의류 제품의 수요 경향을 제시하였다.

  • PDF

Design of an Aircraft Composite Window frame Using VaRTM Process (수지 충전 공정을 이용한 항공기 윈도우 프레임 설계)

  • Kim, Wie-Dae;Hong, Dae-Jin
    • Composites Research
    • /
    • v.19 no.6
    • /
    • pp.1-7
    • /
    • 2006
  • This is the preliminary study to develop composite window frame of commercial aircraft using VaRTM process. For two candidate carbon fabrics(triaxial overbraid, sleeving braider), specimens were fabricated using VaRTM process, and the physical & mechanical property tests were performed to obtain the material properties according to ASTM. FEM analysis for each candidate carbon fabric was performed to find the minimum number of plies and weight for composite window frame to satisfy the design requirements. In this study, Tsai-Wu strength failure criterion was used to evaluate the safety of structure.

수출유사도 지수를 활용하여 분석한 국가별 수출품목의 변화

  • Lee, U-Jeong
    • KDI북한경제리뷰
    • /
    • v.22 no.4
    • /
    • pp.23-38
    • /
    • 2020
  • 본 자료에서는 1998년과 2017년의 수출유사도지수 변화를 파악함으로써 북한의 수출상품이 어떠한 소득수준의 국가와 유사한지 알아보았다. 1998년 수출유사도지수는 한국, 홍콩, 태국, 중국, 일본 순으로 높았으며 2017년에는 미얀마, 모로코, 튀니지, 방글라데시, 스리랑카 순으로 높은 것으로 나타났다. 단편적인 비교일 수 있으나, 1998년 북한의 수출 품목은 한국과 2017년에는 미얀마와 가장 유사하다고 해석 가능하다. 이어서 1998년과 2017년 북한의 수출품목의 비중변화를 관찰한 결과 광물성연료(HS 27)의 수출비중이 가장 크게 증가하였으며, 의류(HS 62), 광·슬래그·회(HS 26), 과실(HS 08), 의류(HS 61)가 뒤를 이었다. 반대로 2017년 1998년에 비해 수출비중이 가장 크게 감소한 품목으로는 전기기기(HS 85), 원자로·기계류(HS 84), 식물(HS 12), 플라스틱과 제품(HS 39), 인조스테이플 섬유(HS 55)이다. 비교분석을 위해 북한과 수출유사도지수가 가장 높은 10개 국가의 수출품목 비중 변화 역시 살펴보았는데, 자세한 품목의 비중변화는 부록의 <부표 1~10>에서 확인할 수 있다. 1998년과 2017년 각각 수출유사도지수가 가장 높았던 한국과 미얀마의 수출품목 변화는 특히 주목할 만하다. 전기기기(HS 85)의 수출이 한국에서는 가장 크게 증가한 반면, 북한에서는 가장 크게 수출이 감소한 상품이었으며, 미얀마의 경우 광물성연료(HS 27), 의류(HS 62), 광·슬래그(HS 26)의 수출이 증가한 것으로 드러난다.

Stretchable Strain Sensors Using 3D Printed Polymer Structures Coated with Graphene/Carbon Nanofiber Hybrids (그래핀/탄소나노섬유 코팅된 3D 프린팅 고분자 구조를 이용한 신축성 스트레인 센서)

  • Na, Seung Chan;Lee, Hyeon-Jong;Lim, TaeGyeong;Yun, Jeongmin;Suk, Ji Won
    • Composites Research
    • /
    • v.35 no.4
    • /
    • pp.283-287
    • /
    • 2022
  • Stretchable strain sensors have been developed for potential future applications including wearable devices and health monitoring. For practical implementation of stretchable strain sensors, their stability and repeatability are one of the important aspects to be considered. In this work, we utilized 3D printed polymer structures having kirigami patterns to improve the stretchability and reduce the hysteresis. The polymer structures were coated with graphene/carbon nanofiber hybrids to make a robust electrical network. The stretchable strain sensors showed a high gauge of 36 at a strain of 32%. Because of the kirigami structures and the robust graphene/carbon nanofiber coating, the sensors also exhibited stable resistance responses at various strains ranging from 1% to 30%.

A Study of Whiter Matter Fiber Tractography in Young Internet Addiction Disorder using a Brain Diffusion Tensor Magnetic Resonance Imaging (뇌 확산텐서 자기공명영상을 이용한 청소년 인터넷 중독자의 백질 섬유로에 관한 연구)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.7-13
    • /
    • 2016
  • The goal of this study is to investigate corpus callosum and both internal capsule changes with the internet addiction disorder compared to control group using MR diffusion tensor imaging. A total of 22 teenager volunteers who had 10 high-risk group with internet addiction and 12 normal control group were conducted for this study. Imaging was conducted on a 3 T using a EPI sequence. Image evaluation was analysed of the FA, ADC($10^{-3}mm^2/s$), length(mm). We did select ROI for image tracking on corpus callosum of 5 and including 2(internal capsule). The data from these ROIs were compared statistically among the groups using independent t-test, correlation coefficient. There were significant inter-group differences(p<0.05) among FA, ADC($10^{-3}mm^2/s$) and length(mm). And also significantly negative correlations were fond between FA values of corpus callosum and IAD scale(p=0.000). DTI was shown significant changes of FA and ADC, LNF values in IAD compared to control group. Therefore, our results may provided clinical information for brain wite matter functions.

Evaluation for Application of IOM Sampler for Agricultural Farmer's Inhalation Exposure to Kresoxim-methyl and Fenthion (농작업자의 Kresoxim-methyl과 fenthion에 대한 호흡노출량 측정을 위한 IOM 채집기의 효율성 평가)

  • Lee, Jiho;Kim, Eunhye;Lee, Jonghwa;Shin, Yongho;Maasfeld, Wolfgang;Choi, Hoon;Moon, Joon-Kwan;Lee, Hyeri;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.3
    • /
    • pp.230-240
    • /
    • 2015
  • An IOM sampler equipped with glass fiber filter has been recently utilized instead of solid adsorbent, which was used to measure the inhalation exposure of agricultural operator to pesticides. The aim of this study is to validate the efficacy of an IOM sampler by measuring the trapping efficiency and breakthrough using kresoxim-methyl water-dispersible granule and fenthion emulsifiable concentrate. On LC-MS/ MS, minimum detection level was 12.5 pg and method limit of detection was 5.0 ng/mL. Good linearity ($R^2$ > 0.999) for matrix matched standards was obtained. Recoveries of pesticides from glass fiber filter were 102-109% (kresoxim-methyl) and 97-104% (fenthion) while those from XAD-2 resin were 94-98% (kresoxim methyl) and 93-100% (fenthion). Trapping efficiency test was performed with personal air pumps and IOM sampler (glass fiber filter) connected with solid adsorbent (XAD-2 resin) with two types of formulation (solid and liquid) which were diluted by standard rate and sprayed to IOM sampler. Those pesticides were trapped only in glass fiber filter without any breakthrough to solid adsorbent. After spiking of pesticides to glass fiber filter, breakthrough test was carried out with IOM sampler (glass fiber filter) which was connected with solid adsorbent. As a results, 87-101% of kresoxim-methyl and 96-105% of fenthion remained in spiked glass fiber filter, however, no pesticides were detected in second glass fiber filter and solid adsorbent. In conclusion, IOM sampler which equipped with glass fiber filter can be applied widely for pesticide inhalation exposure study since it has good trapping efficiency and adsorption capacity, regardless of the solid or liquid formulation.

Development of a Modular Clothing System for User-Centered Heart Rate Monitoring based on NFC (NFC 기반 사용자 중심의 모듈형 심박측정 의류 시스템 개발)

  • Cho, Hakyung;Cho, SangWoo;Cho, Kwang Nyun
    • Science of Emotion and Sensibility
    • /
    • v.23 no.2
    • /
    • pp.51-60
    • /
    • 2020
  • This study aimed to develop a modular smart clothing system for heart rate monitoring that reduces the inconvenience caused by battery charging and the large size of measurement devices. The heart rate monitoring system was modularized into a temporary device and a continuous device to enable heart rate monitoring depending on the requirement. The temporary device with near-field communication (NFC) and heart rate sensors was developed as a clothing attachment type that enables heart rate monitoring via smart phone tagging when required. The continuous device is based on Bluetooth Low Energy (BLE) communication and batteries and was developed to enable continuous heart rate measurement via a direct connection to the temporary device. Furthermore, the temporary device was configured to connect with a textile electrode made of a silver-based knitted fabric designed to be located below the pectoralis major muscle for heart rate measurement. Considering the user-experience factors, key functions, and the ease of use, we developed an application to automatically log through smart phone tagging to improve usability. To evaluate the accuracy of the heart rate measurement, we recorded the heart rate of 10 healthy male subjects with a modular smart clothing system and compared the results with the heart rate values measured by the Polar RS800. Consequently, the average heart rate value measured by the temporary system was 85.37, while that measured by the reference device was 87.03, corresponding to an accuracy of 96.73%. No significant difference was found in comparison with the reference device (T value = -1.892, p = .091). Similarly, the average heart rate measured by the continuous system was 86.00, while that measured by the reference device was 86.97, corresponding to an accuracy of 97.16%. No significant difference was found in terms of the heart rate value between the two signals (T value = 1.089, p = .304). The significance of this study is to develop and validate a modular clothing system that can measure heart rates according to the purpose of the user. The developed modular smart clothing system for heart rate monitoring enables dual product planning by reducing the price increase due to unnecessary functions.

Study on the Characterictics of Insulating Coating Materials for $SF_6$ Insulated Electrical Equipment ($SF_6$ 가스 전기기기용 절연코팅재 특성연구)

  • Park, Hoy-Yul;Kang, Dong-Pil;Ahn, Myeong-Sang;Ha, Min-Ja;Kim, Dae-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1443-1445
    • /
    • 2002
  • 내전압과 내아크성을 높이고 $SF_6$가스 내에서 복합재료로 사용된 유리섬유를 보호하기 위한 코팅 재료를 만들어서 특성을 평가하였다. 에폭시 수지에 내아크성이 우수한 무기물 필러인 $Al_2O_3$, $MgAl_2O_4$, BN, MgO 등을 첨가하여 절연저항, 유전특성, 내아크성 등의 전기적 특성을 평가하였다. 코로나 처리에 의한 열화를 평가하기 위하여 접촉각을 측정하고 전자현미경으로 표면의 상태를 관찰하였다.

  • PDF

조선산업과 차세대 성장동력

  • 홍성인
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.41 no.1
    • /
    • pp.12-18
    • /
    • 2004
  • 우리나라는 60년대 경공업, 70년대 중화학공업, 80년대 조립가공산업과 90년대 IT 제조업 등 시대 별로 성장주도 산업을 중심으로 산업화를 이뤄내 현재의 경제발전을 이룩해 왔던 것으로 평가되고 있다. 특히 90년대 말 외환위기라는 국가적 위기상황을 조선산업을 위시한 자동차, 기계, 철강, 석유화학, 섬유패션 등 주력산업과 반도체, 컴퓨터, 통신기기 등 IT제조업 등의 경쟁력 회복에 힘입어 성공적으로 극복해 왔다. 그러나 국내외의 급변하는 산업여건변화와 그에 따른 도전을 슬기롭게 대처하여 우리나라 경제가 새롭게 재도약하기 위해서는 기존 주력산업의 기술 혁신을 통한 제품고급화, 제품차별화, IP, BT, NT 등 신기술과의 접목, 새로운 수요에 부응한 혁신제품 개발 등을 통해 새로운 산업발전 단계로의 도약이 필요해 지고 있다.(중략)

  • PDF