• Title/Summary/Keyword: 설치깊이

Search Result 533, Processing Time 0.034 seconds

Stability Analysis of the Excavation Slope on Soft Ground using Sheet Pile (널말뚝을 이용한 연약지반 굴착사면의 안정해석)

  • Kang, Yea Mook;Cho, Seong Seop;Lee, Dal Won
    • Korean Journal of Agricultural Science
    • /
    • v.23 no.1
    • /
    • pp.13-24
    • /
    • 1996
  • The following results were obtained by analyzing the displacement, strain and stability of ground at the soft ground excavation using sheet pile. 1. Before setting the strut, the horizontal displacement was large on the upper part of excavated side, but after setting the strut, it showed concentrated phenomenon while being moved to go down to the excavated side. 2. After setting the strut, the displacement of sheet pile was rapidly decreased about a half compared with before setting the strut. The limitation of excavation depth was shown approximately GL-8m after setting double stair strut. 3. Maximum shear strain was gradually increased with depth of excavation, and local failure possibility due to shear deformation at the bottom of excavation was decreased by reinforcement of strut. 4. Maximum horizontal displacement of sheet pile at GL-7.5m was shown 0.2% of excavation depth in elasto-plastic method, and 0.6% in finite-element methods, and the maximum displacement was occurred around the bottom of excavation. 5. To secure the safety factor about penetration depth in the ground of modeling, D/H should be more than 0.89 in the case of one stair strut, and more than 0.77 in the case of double stair strut. 6. The relation of safety factor and D/H about the penetration depth was appeared, Fs=0.736(D/H) + 0.54 in the case of one stair strut, and Fs=0.750(D/H) + 0.62 in the case of double stair strut.

  • PDF

Effects of Anchor Block on Stability of Concrete Electric Pole (콘크리트전주의 안정성에 미치는 근가의 영향)

  • Ahn, Tae-Bong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.11
    • /
    • pp.5-10
    • /
    • 2012
  • Many electric poles in the softground have been collapsed due to external load. In this study, several tests were performed with variation of numbers and depths of anchor blocks to find effects of anchor blocks on stability of concrete electric poles through earth pressure and displacement analysis. 1.50m depth of anchor block seems appropriate among three kinds of depths. The 2.25m depth of anchor block makes larger displacement due to disturbance caused by excessive excavation. The deeper anchor block, the less earth pressure of passive zone, an active earth pressure gets larger. When two anchor blocks were installed, displacement at top pole decreased 43.8% and 55.6% at ground when 1 anchor block was installed.

Analysis for flood reduction by rain storage tank (빗물저류조 설치에 의한 침수저감 분석)

  • Seung Wook Lee;Seung Jin Maeng;Da Ye Kim;In Seong Park
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.356-356
    • /
    • 2023
  • 충청북도 청주시 상당구 월오동 251-7번지와 251-15번지 2곳에 각각 50m3 규모의 빗물저류조를 대상으로 2017년 7월 16일 호우사상을 적용하여 설치 전·후의 침수저감 효과를 분석하였다. 침수분석을 위해 지형자료는 국토정보플랫폼에 있는 1:25,000 자료를 활용하였으며, 모의 전 대상지역의 관망구축에 따른 지형자료를 구축하였고 관망은 노드 40개와 링크 39개로 구성하였다. SWMM 모형을 구동하여 유역내 유출량을 분석하기 위해 유역과 관련한 입력자료와 이외 유역간의 연결부인 관거 하도 입력자료 구축 및 하도와 하도를 연결하는 모델상의 Junction인 실제 맨홀과 관련한 입력자료를 구축하였다. 관거 입력자료로는 관거의 제원, 길이, 깊이 등의 자료를 수집하여 사용하였다. 빗물저류조 설치전·후의 침수저감효과를 분석하기 위해 빗물저류조 설치전의 침수양상을 모의 하였으며 각각 강우발생 후 30분, 50분, 70분, 90분, 110분, 130분 및 150분으로 구분하여 분석하였다. 강우발생 후 150분의 모의분석 결과, 침수심은 0.2<깊이<0.4의 면적이 600m2로 가장 넓은 침수분포를 나타내었으며, 총 침수면적은 2,225m2로 모의되었다. 이는 강우발생 후130분 보다 125m2 더 침수되었으며, 0.8<깊이<1.0의 면적은 150m2로 모의되었다. 전체적인 침수심도 커진 것으로 분석되었다. 빗물저류조 설치 후의 침수양상을 모의하였으며 각각 강우발생 후 30분, 50분, 70분, 90분, 110분, 130분 및 150분으로 분석하였다. 강우발생 후 150분의 모의분석 결과, 침수심은 0.2<깊이<0.4의 면적이 250m2로 가장 많은 침수분포가 나타났으며, 총 침수면적은 550m2으로 모의 되었다. 이는 강우발생 후 110분과 침수면적은 동일하게 모의 되었으며, 침수심 0.2<깊이<0.4의 면적은 250m2로 모의 되었다. 따라서 해당 지역에 50m3 규모의 빗물저류조 2개를설치 할 경우 침수피해가 저감되는 것으로 분석되었다. 이러한 분석 결과를 바탕으로 향후 도시내 상습침수구역에 빗물저류조를 설치하여 기후변화에 따른 극한 강우에 대비할 수 있도록 해야 할 것이다.

  • PDF

A Study on Measurement of Penetration Depth of Steel Pipe Using the Impact-Echo Method (충격탄성파법에 의한 강관구조물 근입깊이 측정에 관한 연구)

  • Lee, Sang Hun;Kumagai, Takayuki;Endo, Takao;Han, Youn Hee
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.89-89
    • /
    • 2011
  • 도로의 가드레일 지주 근입깊이의 부족에 의한 자동차의 전락사고 이 후, 일본의 국토교통성 등의 관계자들이 그 대책 세우기에 부심해 왔으나, 기설 지주의 근입깊이를 측정할 수 있는 방법은 아직까지 알려져 있지 않으며, 현재로서는 작업의 전 과정을 비디오로 촬영하여 그 기록을 남기도록 되어있다. 그러나 그것은 상당히 비효율적인 작업으로 엄밀한 감시기능을 다하지 못하고 있으며, 감독자와 시공자의 양자로부터 계측 도구의 개발이 절실히 요구되고 있다. 일부의 초음파 측정기 업자가 가드레일 지주의 근입깊이를 측정할 수 있다고 주장하고 있으나, 시장에는 아직 나타나지 않고 있으며, 그 측정시스템의 측정여부와 성능의 검증이 이루어지지 않고 있는 상황이다. 지금까지 충격탄성파법 또는 초음파법을 이용하여, 매설된 가드레일 지주의 근입깊이를 측정한 성공사례가 정식으로 보고된 바는 없으며, 같은 강관주인 눈사태 방지책의 지주 파이프에 대한 근입깊이의 측정은 본 연구그룹의 의해 행하여진 바가 있다. 검사봉이나 해머 등으로 대상물을 두드려서 탄성파를 발생시키고, 그것을 가속도계 또는 속도계의 진동센서로 감지하여 그 파형을 분석함으로써 대상물의 치수 등을 측정하는 충격탄성파법은, 특히 콘크리트를 대상으로 공동 및 매설물 등의 탐사, 균열깊이의 측정 등에 폭 넓게 사용되고 있다. 하지만 이 측정방법을 가드레일의 지주의 근입깊이 측정에 적용할 경우, 일반적으로 행하여지는 방법, 즉 진동센서를 대상물의 상단부(캡)에 설치하는 방법으로는 접합부에 의한 탄성파의 손실과 캡의 휨 진동에 의한 노이즈 등을 해결하기가 곤란해진다. 또한 지반의 존재로 인한 진동 모드의 변화와 진동에너지의 감소 등의 문제점을 해결하지 않으면 안 된다. 본 연구는 충격탄성파법을 이용하여 지반에 설치된 눈사태 방지책이나 가드레일의 지주와 같은 강관 구조물의 근입깊이를 측정하고자 하는 연구이다. 이를 위해 진동센서를 캡이 아닌 측면부에 취부장치를 이용하여 설치함으로써 길이방향의 탄성파를 측정할 수 있도록 하고, 실제 구조물에 대해 측정을 실시하여 그 측정시스템의 성능과 유용성을 검토하고자 한다. 또한 다양한 길이의 실험용 강관 파이프를 매설하고 측정실험을 실시하여 측정시스템의 적용성에 대해서도 검토하였다. 본 연구를 통하여, 수신센서를 파이프의 측면에 선접촉하게 함으로서 종파를 감지하여 근입깊이를 포함한 파이프의 전 길이를 측정하는 본 측정시스템은 매설된 강관 구조물의 길이 측정에 기본적으로 적용 가능함을 확인할 수 있었다. 특히 오거 굴착으로 시공된 경우에는 높은 정도의 측정성능을 보여주었다. 또한 항타관입 파이프에 대해서는 지반의 영향을 고려함으로써 길이의 측정이 가능하다는 것을 확인할 수 있었다. 즉, 오거 굴착 또는 항타 관입 등 시공방법에 따라 측정결과에 대한 지반의 영향 정도가 달라지며 파형 분석 및 길이 산정시 그 영향을 고려하여야 함을 확인하였다.

  • PDF

A Study on Serviceability of PVDF Piezoelectric Sensor for Efficient Vehicle Detection (효율적 차량 검지를 위한 PVDF 압전센서의 사용성 연구)

  • Jung, YooSeok;Oh, JuSam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.151-157
    • /
    • 2018
  • Among the various sensors for measuring traffic, PVDF (polyvinylidene fluoride) piezoelectric sensors are used to classify vehicles because they can detect the axle of the vehicle. Piezoelectric sensors are embedded in road pavements and are always exposed to traffic loads and environmental loads. Therefore, the life expectancy is very short, less than 6 years. Traffic control is essential for reinstallation and data collection is interrupted during the failure period. The lifespan will increase if the sensor installation depth is increased. In this study, the sensor signal output was analyzed with a variable depth of sensor installation to verify the possibility of deeper installation. Furthermore, various parameters, such as the weight and speed, were analyzed. The wheel load is applied using APT. As a result, the MSI BL sensor output signal is higher than 100mV when installed at 3cm, which is reliable. If the location of the sensor is deeper in the pavement, the expected lifetime of the sensor is also increased. On the other hand, the MSI cable was found to be less than 100mV at the shallowest depth of 1cm, making it impossible for field applications.

Finding Optimal Installation Depth of Strong Motion Seismometers for Seismic Observation (지진 관측을 위한 최적 설치심도 조사 방법 연구)

  • Seokho Jeong;Doyoon Lim ;Eui-Hong Hwang;Jae-Kwang Ahn
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.2
    • /
    • pp.31-40
    • /
    • 2023
  • We installed temporary strong motion seismometers at the ground surface, 1 m, 2 m, and 9 m at an existing seismic station that houses permanent seismometers installed at 20 m and 100 m, to investigate the influence of installation depth on the recorded ambient and anthropogenic noise level and the characteristics of earthquake signals. Analysis of the ambient noise shows that anthropogenic noise dominates where vibration period T < 1 s at the studied site, whereas wind speed appears to be strongly correlated with the noise level at T > 1 s. Frequency-wavenumber analysis of 2D seismometer array suggests that ambient noise in short periods are predominantly body waves, rather than surface waves. The level of ambient noise was low at 9 m and 20 m, but strong amplification of noise level at T < 0.1 s was observed at the shallow seismometers. Both the active-source test result and the recorded earthquake data demonstrated that the signal level is decreased with the increase of depth. Our result also shows that recorded motions at the ground and 1 m are strongly amplified at 20 Hz (T = 0.05 s), likely due to the resonance of the 3 m thick soil layer. This study demonstrates that analysis of ambient and active-source vibration may help find optimal installation depth of strong motion seismometers. We expect that further research considering various noise environments and geological conditions will be helpful in establishing a guideline for optimal installation of strong motion seismometers.

Fluid Flow CFD Simulation in Lake during Summer Stratification (성층기 저수지 수체 인공순환 모사)

  • Lee, Yo-Sang;Ban, Yang-Jin;Sohn, Byeong-Yong;Kim, Young-Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.952-956
    • /
    • 2010
  • 저수지에 설치된 물순환장치는 저수지 수문상황과 자연조건의 변화에 따라 유동특성이 상이하므로 연구자가 고려하는 다양한 조건에서 현장 측정하기는 불가능하다. 이런 문제를 대체하는 방안으로 전산유체유동(CFD) 모형을 적용한 모사를 실시함으로서 다양한 조건에 따른 효과를 평가할수 있게 된다. 본 연구에서는 전산유체유동을 통한 대류식 물순환장치의 유동영향범위와 수질변화 등을 평가하고, 다양한 조건에서 모사를 실시하여 최적운영방안을 도출하고 실제운영에 활용토록 하고자 한다. 수체거동을 모사하기 위해 실제 저수지를 형상화한 Domain을 3가지로 구성하였다. 첫번째는 반경 20m, 깊이 40m Domain에 물순환장치를 중앙에 설치한 것이며(D20), 두 번째는 반경 40m, 깊이 40m에 두 개의 물순환장치를 양쪽에 설치하였고(D40), 세 번째는 반경 100m, 깊이 40m로 설정(D100)하였고 양쪽에 두 개의 물순환장치를 설치한 것으로 구성하였다. CFD에 의한 개별 대류식 순환장치의 유동모사결과 D20은 시간의 경과에 따라 수온성층이 하강하는 현상이 나타났으며 이러한 결과로 판단할때 40m 간격으로 대류식 순환장치를 설치하여 운영하면 탈성층이 나타날 수 있을것으로 판단되었다. D40에 대하여 CFD에 의한 유동모사를 실시하였으며 시간의 경과에 따라 수온성층의 변화는 나타나지 않았다. 이러한 결과로 판단할때 40m 간격으로 한줄로 대류식 순환장치를 설치하여 운영하면 성층을 깨는 현상은 나타나지 않을 것으로 평가되었다. 반면 Dye테스트시 심층에서 상승한 수체는 수온성층 표면에서 수평방향으로 계속 퍼져 나가면서 옆장치에서 상승된 수체와 혼합이 활발히 이루어 지는 현상을 나타내었다. 장치간 거리가 100m인 대류식 물순환장치에 의한 유동모사시 수온성층의 변화는 전혀 나타나지 않았으며, Dye테스트시 심층에서 상승한 수체는 수온성층 위에서 수평방향으로 퍼져 나가면서 옆에서 가동되는 장치에서 상승된 수체와 혼합 현상을 나타내기는 하나 D40보다 혼합시간이 더 걸리는 것으로 나타났다.

  • PDF

A Study on the Stability of Group Piles Installed in the Deep Sea to the Seaquake (해진에 대한, 심해에 설치된 군말뚝의 안정성에 관한 연구)

  • 최용규;남문석;정두환
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.31-42
    • /
    • 2000
  • In this study, the stability of group piles installed in deep sea to the seaquake was studied by performing the calibration chamber model tests for open-ended pipe piles, grouted piles under soil plug and close-ended piles installed in the simulated deep sea. For each case (a single pile, 2-pile and 4-pile groups), series of seaquake tests were performed. While, during the simulated seaquake, the compressive capacity of the single open-ended pile depended on pile penetration depth(=7m), were found to be stable. But, a single grouted pile with penetration depth of 13m kept "mobility" state, the one with penetration depth of 20m was stable and grouted pile groups with penetration depth of 7m were stable regardless of pile penetration depth. By grouting soil plug of open-ended piles and soil under the pile toe of open-ended pipe piles installed in the deep sea, failure of soil plugging was prevented. Thus, close-ended piles were more stable than open-ended pile against the seaquake motionake motion.

  • PDF

Geometry of Scour Holes around Group Groynes (연속수제로 인한 세굴공의 기하학적 특성 연구)

  • Son, Kwang-Ik;Kim, Hyun-Jung;Kang, Yong-Gu;Yoon, Young-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.345-345
    • /
    • 2011
  • 최근 각종 하천 개발 사업이 활발히 진행되면서 하천환경변화에 따라 발생 가능한 다양한 현상 예측 및 그에 대한 대책수립이 요구되는 실정이다. 특히 하도안정 및 평면적 유로를 유지하기 위해서는 수제와 같은 수공 구조물이 효과적인 것으로 알려져 있다. 그러나 국내에서는 제한적인 연구와 소수의 수제 설치만 진행되었을 뿐 실용화를 위한 기술 개발 연구는 미흡한 실정이다. 단일 수제의 기하학적 특성에 의한 세굴 및 퇴적 등 하상의 변화에 관한 연구는 다수 진행되었으나 연속 수제에 대한 연구는 거의 없는 실정이다. 따라서 본 연구에서는 이동상 수리실험을 통하여 단일수제와 연속수제 설치에 따른 세굴깊이와 길이, 폭 등 하상변화의 기하학적 형상을 지배하는 월류비와 후루이드 수 등 수제설계 지배인자에 대한 특성을 검토하였다. 단일수제와 연속수제에 대하여 월류조건과 비월류조건의 경우로 분류하여 후루이드 수의 영향을 검토하였다. 실험분석 결과 후루이드 수와 월류비가 수제 설치에 따른 세굴 깊이, 세굴 길이 및 세굴 폭의 지배인자임을 확인하였다. 후루이드 수가 증가할수록 세굴깊이와 길이, 폭은 증가하는 것으로 나타났으나 월류비가 증가할수록 세굴깊이와 길이, 폭은 감소하는 것으로 나타났다. 연속수제의 경우 첫 번째 수제 주변의 하상변화는 단일수제와 그 규모가 유사한 것으로 나타났으나 두 번째 또는 세 번째 수제부터의 하상변화 규모는 첫 번째 수제에 비해 작아지는 것으로 나타났다. 또한 세번째 수제 이후 모든 수제에서의 하상변화 규모는 거의 일정한 것으로 확인되었다. 본 연구에서 제시한 하상변화 지배인자와 단일수제, 연속수제 별 세굴공의 기하학적 특성과의 관계는 하상의 안정성 확보를 위한 수제 설계를 위한 기초자료로 활용될 수 있을 것으로 기대된다.

  • PDF