• Title/Summary/Keyword: 설정압

Search Result 189, Processing Time 0.028 seconds

A Study on Establishment of Brassiere Size and Clothing Pressure for the Twenties-aged Women (20대 여성의 브래지어 치수설정과 의복압에 관한 연구)

  • 박유신;임영자
    • Journal of the Korean Society of Costume
    • /
    • v.52 no.8
    • /
    • pp.15-27
    • /
    • 2002
  • To set the measurements of bras for women in their 20s, considering the comfortableness in wearing and tightness, this paper conducted a questionnaire survey concerning breasts and bras as well as measurements of body and contact surface pressure. Easier and more accurate method of determining cup sizes based on the breast circumference is recommended to make up for the problem of current bra size system that can falsely measure cup sizes. Lower chest circumference was set at 5 cm equal intervals, and the breast circumference applicable to the cup size was set starting from the standard, 18 cm (A-cup), at 2 cm equal intervals, which gave the best coverage (88.1%).

Development of Algorithm for Optimal Energy Operation of Industrial Load Using ANN (ANN을 이용한 산업현장의 최적 에너지 운용 알고리즘 개발)

  • Kim, Seob-Han;Kim, Byeong-Mpk;Kim, Byeong-Ki;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.516-519
    • /
    • 2012
  • 산업 현장에 필수적으로 사용하는 유틸리티 시스템(Utility System)의 하나인 에어를 생산하는 공기압 축기의 운전방식은 조작 패널부에 사용자가 설정한 셋팅값에 의해 내부의 밸브를 제어하여 로딩 및 언로딩 운전을 한다. 이로 인해 대용량(100HP, 200HP)의 공기압축기를 여러대 사용하는 수용가에서는 연속 다발적인 운전으로 인한 전력 사용량의 변동으로 역률 저하 및 연속가동으로 인한 설비 과부하 및 내부 기계 베어링 피로도 증가 및 파손 등 고장이 발생되는 문제점이 있다. 따라서 본 논문에서는 인공 신경회로망(ANN:Artificial Neural Network)을 이용하여 최적의 에너지 운용 알고리즘을 제안하여 실계통의 문제점을 분석하여 개선하고자 한다.

  • PDF

A Study on IGBT inverter for sinusoidal wave output PAM type (PAM-PWM 인버터에 의한 정현파출현)

  • 이현우;정기화;우정인
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.5
    • /
    • pp.521-528
    • /
    • 1992
  • this paper a new PAM-PWM Inverter using IGBT Is described. The output waveforms in the proposed PAM-PWM inverter are investigated both theoretiically and experimentally. The line-voltage waveform is composed of fundamental component and the sidebands of carrier frequency. The lower order harmonics are not included In the output waveform. As each inverter arm does not operate during two-thirds period, the heats, generated in the devices are reduced. That is the size of the inverter system can be minimized because of the reduction In the heat dissipating equipemnt.

  • PDF

Diamond Synthesis by the Thermal Plasma CVD at Atmospheric Pressure (대기압 열플라즈마 CVD에 의한 다이아몬드 합성)

  • Lee, Jae-Ho;Ko, Myung-Wan;Park, Dong-Wha
    • Applied Chemistry for Engineering
    • /
    • v.5 no.1
    • /
    • pp.16-23
    • /
    • 1994
  • In an argon thermal plasma CVD system diamond of metastable state was synthesized on molydenum substrate and concentration ratio of methane to hydrogen. Diamond was relatively well obtained when surface temperature of substrate was $890^{\circ}C$ and concentration of methane ratio was 0.5 percents.

  • PDF

염해도조사연구

  • 김영식
    • 전기의세계
    • /
    • v.22 no.6
    • /
    • pp.65-70
    • /
    • 1973
  • 최근 대단위 용량의 발변전소 건설과 아울러 확대되는 초고압 송배전 시설은 공히 그 계통의 신뢰성향상이 필연적으로 요구되고 있다. 발변전소의 전기기기나 송배전 시설물의 애자나 애관류가 염진이나 연진에 의해 받는 피해는 적지않다. 따라서 우리나라 해안에 인접하고 있는 주요발변전소 및 송배전 시설물을 대상으로 염진오손도를 조사하여 지역별로 오손기준을 설정하여 신증설되는 발변전소 및 송배전 시설물의 내염설계 및 유지보수의 참고자료를 얻기 위하여 염진해가 기할곳으로 예상되는 울산, 고리, 금산, 삼척, 강릉, 인천, 순천, 여수, 제주 등지를 조사대상지역으로 선정하여 염해도조사를 실시하였다. 시료는 250mm 현수애자 일련 12개씩을 29개소에서 무과전 수직조가하여 매일 정기일정에 시료를 채취하여 등가염분량을 구하여 인천지구 시료애자는 오손상태에서 건조섬락시험 및 윤활상태에서 섬락시험들을 하였다.

  • PDF

Quantity of the Agent in the Piping System of Low Pressure Carbon Dioxide Extinguishing Systems (저압이산화탄소 소화설비의 방출배관내 약제량)

  • Kim, Wee-Kyong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.136-139
    • /
    • 2011
  • 국가화재안전기준 107 및 107A에서 할로겐화합물 소화설비와 청정소화약제 소화설비 설계시 하나의 방호구역을 담당하는 저장용기의 소화약제의 체적합계보다 소화약제의 방출시 방출경로가 되는 배관(집합관을 포함한다)의 내용적의 비율이 설정된 값 이상인 경우 당해 방호구역에 대한 설비는 별도의 독립방식으로 하도록 요구하고 있다. 이산화탄소 소화설비의 경우에는 이산화탄소의 증기압이 충분히 높으므로 방출배관의 용적에 대한 제한사항이 포함되어 있지 않으나 저압이산화탄소 소화설비의 경우 약제의 저장온도가 낮으므로 방출시 기화되어 설계시 의도한 방출량을 만족시키지 못할 수 있다. 본 논문에서는 저압이산화탄소 소화설비에 대한 방출배관 용적 제한 필요성에 대하여 논의하였다.

  • PDF

Research on Dose Reduction During Computed Tomography Scanning by CARE kV System and Bismuth (전산화 단층검사 시 Bismuth와 CARE kV System을 이용한 선량 저감화에 대한 연구)

  • Kwak, Yeong-Gon;Kim, Chong-Yeal;Jeong, Seong-Pyo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.8
    • /
    • pp.233-242
    • /
    • 2014
  • The purpose of this study is to compare the reduction of the dose radioactivity by CARE kV with that of the Bismuth shielding. First, CT was performed with transparent materials, including a Bismuth shielder which is a well-known material for decreasing the dose of radiation. Moreover, we have estimated and compared the affects of the reduction of dose on eye lens, thyroid, breast and genitals. These steps aim to compare reactions with and without the application of the Rando phantom with PLD as well as with CARE kV or not. As a result, during the Brain angio scan, the dose of CARE kV set inspection test methods showed the least dose. Depending on whether we use CARE kV, which showed the effect of dose reduction by 63%. During the Carotid angio scan, the dose was increased by 13% by how to set CARE kV+Bismuth. During the Cardiac angio scan, which showed the effect of dose reduction by 31% by how to set CARE kV+Bismuth. During the Lower extremity angio scan, the dose was measured least by how to set up the whole Bismuth. Compared with CARE kV set of test methods, which showed the effect of dose reduction by 9%.

Dynamic Behavior of Unsaturated Decomposed Mudstone Soil Under Low Strain Amplitude (저변형률하 불포화 이암풍화토의 동적거동)

  • Huh, Kyung-Han;Chung, Choong-Sun;Bae, Joong-Seon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.2 s.13
    • /
    • pp.19-27
    • /
    • 2004
  • The interest in the dynamic properties of soils has increased strongly because of earthquake, heavy traffic, and foundations undergo high amplitude of vibrations. Most of soils in Korean peninsula are composed of granite soils, especially the decomposed mudstone soils are widely spread in Pohang areas, Kyong-buk province. Therefore, it is very important to investigate the dynamic properties of these types of soils. The most important soil parameters under dynamic loadings are shear modulus and material dampings. Furthermore, few definitive data exist that can evaluate the behavior of unsaturated decomposed mudstone soils under dynamic loading conditions. The investigations described in this paper is designed to identify the shear modulus and damping ratio due to a surface tension for the unsaturated decomposed mudstone soils under low and high strain amplitude. For this purpose, the resonant column test and the cyclic triaxial test were performed. Test results and data have shown that the optimum saturated degree of decomposed mudstone soils under low and strain amplitude is $32{\sim}37%$ which is higher than that of decomposed granite due to the amount of fine particles as well as the type and proportion of chief rock-forming minerals.

A Study on Measurement of Output Dose in X-ray Unit (X-선장치에서 출력선량 측정에 관한 연구)

  • Kim, Jong Eon;Lee, Sang Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.289-294
    • /
    • 2020
  • In order to control the quality of X-ray images and patient exposure, it is necessary to document the output dose(air absorption dose(mGy)) output from the X-ray unit from the measurement. The purpose of this study is to find an equation that can calculate the output dose from the measurement of the output dose and output factor(Of) of the X-ray Unit. The output dose and output factors of the X-beam irradiated from the X-ray unit were measured using an XR multi-detector. The output dose calculation formula was obtained by fitting the measured output dose divided by the tube current-exposure time product(mAs) and the set tube voltage with Allometric1. The final output dose calculation formula was obtained by multiplying this formula with the output factor. It is considered that the obtained final output dose calculation formula will be useful for all tube voltages, tube currents, exposure times, field sizes, and distances.

Optimization Analysis of Connection Part for Electric Power Cable Connection System Using Extra High Voltage Power (초고압 전력 케이블 접속 시스템을 위한 접속재의 최적화 해석)

  • Lee, Yang-Chang;Ryu, Jeong-Hyun;Han, Bong-Soo;Lee, Joon-Seong;Lee, Ho-Jeong;Choi, Yoon-Jong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.532-535
    • /
    • 2009
  • 본 논문은 초고압 전력케이블의 접속재 개발을 위한 연구결과로써, 접속시스템의 핵심기술인 고절연 고무슬리브 및 현장에서 접속 작업의 용이성을 위한 Carrier Pipe의 구조해석과 전기적 절연설계에 의한 주요부의 전기적 특성과 전계의 집중을 완화하기 위해 Simulation Tool을 이용한 수치해석 등을 실시하여 최적화된 제품을 제작하였다. 절연설계 및 전계완화 해석에서는 고절연 고무슬리브 구조에서 전계가 집중될 수 있는 중요 포인트를 벡터로 선정하였고 이를 기초로 전계해석을 진행하여 선정된 포인트들에서 전계가 집중됨을 검증하였다. 접속재의 수축거동 해석에 의하면, Carrier Pipe의 구조적 안전성을 확보하기 위하여 고절연 고무슬리브로부터의 압력을 구하여 계산한 결과 최소한 9mm이상의 Carrier Pipe 두께가 필요한 것으로 파악 되었다. 이것은 충분한 강도뿐만 아니라 Carrier Pipe의 변형발생으로 인한 현장에서의 설치문제까지 고려하게 된 값이다. 고절연 고무슬리브 제품설계 에서는 고절연 고무슬리브의 특성조건을 설정하였고 고절연 고무슬리브 제품 및 Carrier Pipe의 Interface 설계 기준을 파악하기 위하여 기존의 고절연 고무슬리브를 활용하여 Carrier Pipe와의 장착 Test를 진행하였다. 그 결과, 확장비율 110%로 적용하였을 경우는 30시간 후에는 완전 붕괴가 되었고, 붕괴가 시작되는 지점이 고절연 고무슬리브의 중앙매립전극 경계면으로써, Simulation Tool을 활용한 접속재 수축 거동 해석 결과와도 일치함을 검증 할 수 있었다.

  • PDF