• Title/Summary/Keyword: 설비용량

Search Result 713, Processing Time 0.024 seconds

Research on the Resources Investigations of Small Hydropower Generation in Northern Gyeong-Buk Area (경북 북부지역 소수력발전 자원조사에 관한 연구)

  • Kim, Jung-Hun;Kim, Dong-Hyun;Hwang, Jong-Kyu;Kim, Sungwon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.5B
    • /
    • pp.459-466
    • /
    • 2011
  • In this study, the resources investigations of small hydropower generation were carried out for the five proposed sites in northern Gyeong-buk area. They consisted of the discharge measurements, rating-curve, flow duration curves, electricity generation, and economic analysis, respectively. The basic data were suggested to select the optimal small hydropower sites in northern Gyeong-buk area. The sites for Yecheon Gun and Munsu Myeon as a result are the best proposed ones using economic analysis. We considered, however, that the finacial benefit for small hydropower development may be small under 500 kW facility. The optimal proposed site over 500 kW facility was suggested as Yeongyang Gun in this study.

Characteristics Analysis for Voltage, Current & Capacity of Condenser at Voltage Unbalance (전압 불평형시 콘덴서 전압, 전류, 용량 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.145-151
    • /
    • 2010
  • Voltage unbalance is regarded as a power quality problem of significant at the user application. Although the voltages are quite well balanced at the transmission system, the voltage level of utilization can be unbalanced due to the unequal system impedances and the unequal distribution of single phase loads. Capacitor is generally used for power-factor compensation and reducing harmonics of non linear load with reactor. If voltage unbalance exists, current unbalance is generated and it will be reflected in the capacity variance. When the reactor and condenser are used at the same location, generally its trouble rate is high. And it is very important checking out that how the variance of voltage, current and capacity of condenser is proceeded by the voltage unbalance. In this paper, we calculated that voltage, current and capacity of condenser are within the tolerance limit of official regulations in the event of voltage unbalance with/without reactor.

Recommended Practice for a Reasonable Design Demand Factor and Analysis of Power Consumption Characteristics by loads in Hospitals (병원용 건물의 부하종별 전력소비특성 분석 및 수용률 기준 정립에 관한 연구)

  • Yoo, Sang-Bong;Kim, Se-Dong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.77-84
    • /
    • 2007
  • It is increased electrical energy consumption with the development of intelligence society in hospitals and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design demand factor in hospitals, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 32 hospitals and 9 electrical design offices. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried the linear and nonlinear regression analysis.

An Efficiency Evaluation of Korea's Electric Power Generation Industries using DEA model (DEA 모형을 활용한 국내 발전회사의 효율성 평가)

  • Koh, Seung-Churl;Sim, Gwang-Sic;Kim, Jae-Yun
    • Journal of the military operations research society of Korea
    • /
    • v.34 no.1
    • /
    • pp.61-77
    • /
    • 2008
  • Data Envelopment Analysis(DEA) is a promising methodology to evaluate the relative efficiency of the decision-making units. We have compared the efficiency of six electric power generation companies in Korea using DEA. The analysis results by input-oriented CCR and BCC models are summarized as follows: first, different results were acquired between using input factors as total capacity of generators and as sub-totals of generator capacity based on primary energy sources. It is the result influenced by input factors which are characterized by the proportion of fixed costs(generating facilities) and variable costs(generation costs for primary energy), Second, the efficiency will be increased if the input factors selected, according to primary energy sources discussed in this research, are used during long-term expansion of electric power capacity plans. It is expected that this approach can give a feedback for management of electric power generation companies.

Recommended Practice for Demand Factor using Regression Analysis Theory depending on Power Consumption Characteristics in Commercial Buildings (업무용빌딩의 전력소비 특성을 고려한 회귀분석이론을 이용한 수용률 기준 설정)

  • Kim, Se-Dong;Shin, Hyo-Seop;Kim, Soo-Gil;Oh, Kie-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.217-222
    • /
    • 2004
  • 고도 정보화 사회의 진전으로 전기에너지의 소비는 급격히 증가하고 있다. 특히 업무용 빌딩과 같은 전력다소비 건물에서는 전력의 효율적 이용에 의한 에너지절감은 물론 설계 단계에서의 합리적인 전기설비 설계가 요청되고 있다. 현재 우리나라의 기후 특성과 전력소비 특성을 고려한 합리적인 전기설비 설계를 위한 기초 자료가 매우 미흡한 실정이다. 본 연구에서는 합리적인 수용률 기준을 설정하기 위하여 사무소용 빌딩의 전력 소비 특성을 조사 분석하였고, 아울러 전기설비설계사무소에서 적용하고 있는 수용률을 조사 분석하였다. 조사된 자료 전체의 특징과 중심적인 경향을 알아내기 위해서 평균값, 중앙값, 표준편차, 최대 값, 최소 값, 회귀모형식, 최소제곱 평균오차 등의 확률 통계적 파라미터들을 수용률 기준 설정을 위한 특징 파라미터로 선택하였다. 그리고, 데이터의 신뢰성을 비교 분석하기 위하여 선형적인 방법과 비선형적인 방법으로 그 경향을 추정하여 곡선으로 나타내었다. 이러한 방법에 의하여 얻어진 분석 자료를 이용하여 적정 변압기 용량 설정을 위하여 데이터베이스화하였고, 변전설비용량의 합리적인 설계를 위하여 수용률 기준 적용시에 필요한 자료로 활용할 수 있으리라 사료된다.

  • PDF