• Title/Summary/Keyword: 설계 풍속

Search Result 310, Processing Time 0.034 seconds

The Design of a Wind Speed & Direction Module and a DSP Sensor Interface System for the Meteorological System (기상계측시스템을 위한 풍향.풍속모듈 및 DSP 센서 인터페이스시스템 설계)

  • Song, Do-Ho;Joo, Jae-Hun;Ock, Gi-Tae;Kim, Sang-Gab;Choi, Jung-Keyng
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.8
    • /
    • pp.1478-1485
    • /
    • 2007
  • In this paper, a meteorological system including a wind speed & direction module and the DSP(Digital Signal Processor) sensor interface circuit board are proposed. This DSP system accepts and process the informations from a wind speed & direction module, the atmospheric pressure sensor, the ambient air temperature sensor and transfers it to the PC monitoring system. Especially, a wind speed & direction module and a DSP hardware are directly designed and applied. A wind speed & direction module have a construction that it have four film type RID(Resistive Temperature Detectors) resistive sensor adhered around the circular metal body heated constantly by heating coil for obtaining vector informations about wind. By this structure, the module is enabled precise measurement having a robustness about vibration, humidity, corrosion. A sensor signal processing circuit is using TMS320F2812 TI(Texas Instrument) Corporation high speed DSP. An economical meteorological system could be constructed through the data from wind speed & direction module and by the fast processing of DSP interface circuit board.

Estimation of Basic Wind Speed at Bridge Construction Site Based on Short-term Measurements (단기 풍관측에 의한 교량현장 기본풍속 추정)

  • Lee, Seong-Lo;Kim, Sang-Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1271-1279
    • /
    • 2013
  • In this paper, a study on the prediction method of basic wind speed at the construction site of long-span bridge using short-term measurements was conducted. To determine the basic wind speed in the wind resistant design for the long-span bridge away from the weather station, statistical analysis of long-term data at site is required. Wind observation mast was installed at site, and short-term measurements were gathered and the correlation analysis between the site and the station was done using regression analysis and MCP(Measure-Correlate-Predict). The long-term wind data of the site was obtained from correlation formula after topographical revision of long-term data of the station. And basic wind speed could be estimated by extreme probability distribution analysis. The research results show that the wind speed by regression analysis is predicted lower than by MCP and after this study a series of correlation analyses at several sites will show clearly the difference two methods. And also a quality control of long-term wind data is very important in estimation of wind speed.

Estimation of Design Wind Speed Compatible for Long-span Bridge in Western and Southern Sea (서남해안 장대교량에 적합한 설계 풍속 산정)

  • Kim, Han Soo;Lee, Hyun Ho;Cho, Doo Young;Park, Sun Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.2
    • /
    • pp.153-160
    • /
    • 2011
  • Recently there are many long span cable supported bridges like Cable Stayed Bridge and Suspension Bridge already constructed or planned. Reconsidering of proper design wind load of long span bridge is required since the meteorological value based on the data only from 1960s to 1995 has been used when we estimate the wind load for designing long span bridges. In this paper, the research area was confined to western and southern coasts where many long span bridges have constructed. The method of moment and the least-squares method were used to estimate the expected wind speeds of 100 year's return period for girder bridges and for 200 year's return period for long span bridges based on the Gumbel's distribution. As the return-period wind speed on the land face was revised because of recent high speed velocity, the revised return-period wind speed is increased by 17%. Compatibility of return-period wind speed was also evaluated using RMS (Root Mean Square) error method. Aa a result of this paper, the least-squares method is more compatible than the method of moment in the case of western and southern coasts in Korea.

Estimation of Extreme Wind Speeds in Korean Peninsula using Typhoon Monte Carlo Simulation (태풍 시뮬레이션을 통한 한반도 극한풍속 추정)

  • Lee, Sungsu;Kim, Ga Young
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.2
    • /
    • pp.141-148
    • /
    • 2016
  • The long-span bridges such as Incheon Bridge and Seohae Grand Bridge are located on the coastal region effected frequently by strong wind of typhoons. In order to ensure the wind-resistant performance of the structure, estimation of the proper design wind speed is very important. In this study, stochastic estimation of design wind speed incurred by typhoons is carried out. For this purpose, we first established probability distribution of climatological parameters such as central pressure depth, distance of closest approach, translation speed and heading to build statistical model of typhoons, which are employed in Monte Carlo simulation for hypothetical typhoons. Once a typhoon is generated with statistically justified parameters, wind speeds are estimated along its path using wind field model. Thousands of typhoons are generated and their peak wind speeds are utilized to establish the extreme wind speeds for different return period. The results are compared with design basic wind speeds in Korean Highway Bridge Design Code, showing that the present results agree well with similar studies while the existing code suggests higher design wind speed.

Estimation on the Turbulence Characteristics of Daily Instantaneous Maximum Wind Velocity (일순간최대풍속의 난류특성에 관한 평가)

  • Oh, Jong Seop
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.1
    • /
    • pp.75-84
    • /
    • 2017
  • This study is concerned with the estimation of daily instantaneous maximum wind velocity in the meteorological major cities (selected each 17 points) during the yearly 1973-2016. The purpose of this paper is to present the turbulence statistic characteristics (probability distribution, correlation coefficient, turbulency intensity, shear velocity, roughness length, turbulence integral length, skewness, and kurtosis) of the daily instantaneous maximum wind velocity. In the processes of analysis, used observations data obtained at Korea Meteorological Adminstration (KMA). The estimation of non-Gaussian load effects for design applications has often been treated tacitly by invoking a conventional wind design load on the basis of Gaussian processes. This assumption breaks down when the instantaneous wind velocity processes exhibits non-Gaussianity. From the analysis results, the probability distribution of the daily instantaneous maximum wind velocity shows a very closed with non-Gaussian in the ensemble population 748, the correlation coefficient shows larger at inland area more than coastal area.

Control on Wind Speed and Direction of Electric Fan using A.I Fan Sensor (A.I Fan 센서를 이용한 선풍기의 풍향 및 풍속 조절)

  • Kwon, Young-Geun;Choi, Sae-Hoon;Han, Young-Sam;Kim, Myoung-Jin;Park, Chae-Seo;Hur, Joon;Soh, Dea-Wha
    • Journal of the Speleological Society of Korea
    • /
    • no.81
    • /
    • pp.7-19
    • /
    • 2007
  • 본 논문은 초음파센서와 적외선센서를 이용하여 그 신호를 받아 주 모터를 제어한 것으로, 센서를 이용한 선풍기의 풍향 및 풍속을 제어하였다. 풍향제어는 인체감지센서와 ATmega128, DC모터를 사용하였고, 기본적으로 WmAVR과 PonyProg를 사용하여 소스코딩 및 다운로딩을 하였으며, 모터 구동드라이버는 모터제어에 범용으로 쓰이는 L298 칩을 사용하였다. 풍속제어는 초음파센서와 ATmeBa16, DC모터를 사용하여 제작하였고, 풍향제어부와 마찬가지로 WinAVR과 PonyProg 및 L298 칩을 사용하여 소스코딩 및 다운로딩을 하였다. 풍향제어는 물체가 정면에 위치하면 회전을 멈추고, 좌우로 $100^{\circ}$ 반경이내에서 거리 1m내외의 물체를 감지하도록 설계하였다. 풍속제어는 물체까지의 거리를 최소 3cm 최대 3m 이내에서 물체를 감지하여 모터의 속도를 제어할 수 있도록 하였고, 모터속도는 DC모터를 PWM 방식으로 제어하여 속도를 조절하였다.

The Shading Effect and Wind Velocity Variation of Greenhouse with Fan & Pad System (FAN & PAD시스템 온실의 풍속변화 및 차광효과)

  • 이석건;이종원;이현우
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2000.10b
    • /
    • pp.36-39
    • /
    • 2000
  • 온실용 FAN & PAD 시스템의 설계, 시공 및 운용에 필요한 기초자료를 제공하고자 FAN & PAD 온실의 내부풍속변화와 차광에 따른 냉방성능을 실험적으로 분석한 결과를 요약하면 다음과 같다. 1. FAN & PAD 시스템 온실의 내부풍속은 지면높이 80cm에서는 0.35㎧-1.25㎧ 범위에서 불규칙한 변화를 보였으며, 지면높이 210cm에서는 0.63㎧-1.06㎧ 범위에서 다소 규칙적인 변화를 보였다. 그리고, PAD측 풍속은 지면높이 80cm에서는 평균 0.2㎧, 지면높이 210cm에서는 평균 1.16㎧로 규칙적인 변화를 보였다. 2. 주간(10:00-18:00)에 외기온이 28.2$^{\circ}C$-35.1$^{\circ}C$(평균 31.5$^{\circ}C$)범위에서 변화할 때 FAN & PAD 온실의 내부온도는 외기온보다 평균 2.4$^{\circ}C$-2.7$^{\circ}C$정도 낮게 나타났으며 무차광시 냉방효과가 최고 3.2$^{\circ}C$ 감소하는 것으로 나타났다.

  • PDF

A Numerical Study for the Performance of Natural Smoke-venting of a Vertical Vent (수직 배연구의 자연배연 성능에 관한 수치해석연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.1-10
    • /
    • 2008
  • In this study, the effects of vent location, outside temperature, wind velocity and fire size on the performance of natural venting of the vertical vent designed according to NFPA 204 standard and fire characteristics were numerically investigated using CFAST. In cases of the Vent located on most upper wall, lower outside temperature and lower wind velocity, vents met the performance criteria of venting. The larger fire size becomes, the more mass flow rate through a vent becomes, but the lower interface height of smoke layer becomes, so that vent didn't meet the performance criteria of venting. It should be noted that a natural vertical vent be designed considering maximum outside temperature and maximum wind velocity and developing a design fire accurately in order to meet the performance criteria of venting.

A Study On Effectiveness of Prevent Smoke Backflow in Apartment (계단식 공동주택 방연풍속 실효성에 대한 연구)

  • Lee, Kwang­Soo;Yoon, Myong­O;Lee, Jun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • Purpose: The purpose of this study is to analyze the differential pressure and velocity to prevent smoke backflow of Stairways Apartment House fire, and verified the effectiveness of smoke velocity standards proposed by NFSC 501A. Method: The smoke control design of the stairways apartment house of the real model and the performance of the velocity to prevent smoke backflow according to the window opening conditions of the living room were analyzed using the CONTAM program. Result: Although the differential pressure performance of the apartment's smoke control system was satisfactory, it was found that Performance of velocity to prevent smoke backflow did not come out according to the opening condition of the living room window. Conclusion: In the case of Stairways Apartment House, it is necessary to review the method of making exceptions to the 'velocity to prevent smoke backflow' standard required by the National Fire Safety Codes(NFSC 501A)

A Study on the Improvement of the Mast Design for Wind Detector (풍향풍속 검출기 마스트 설계 개선에 관한 연구)

  • Kim, Dong-Young;Park, Hae-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.98-107
    • /
    • 2021
  • During the sea trial test for the aerovane in AOE-II, a malfunction occurred in the wind detector movement around 40 to 90° on the starboard side and around 270 to 320° on the port side. The purpose of this study was to analyze and improve the cause of the above phenomenon. The wind detector was covered with a mast structure and was not affected directly by the blowing wind, and a vortex air current was formed behind the mast structure, causing the motion malfunction. The above problem was solved by moving and installing the wind detector on the newly installed mast yard. After conducting vibration analysis and reviewing the effects of vibration, the wind detector was installed in the new mast yard and verified by a sea trial test. Since the improvement plan was slightly effective, the position of the wind detector moved away from the mast on the new mast yard and was re-verified through a sea trial test. The movement malfunction of the wind detector did not occur, confirming that it is an appropriate improvement plan.