• Title/Summary/Keyword: 설계지진파

Search Result 123, Processing Time 0.023 seconds

Seismic Performance Evaluation of a Cone-type Friction Pendulum Bearing System (원추형 마찰진자베어링의 내진성능평가)

  • Jeon, Bub-Gyu;Chang, Sung-Jin;Park, Kyung-Rock;Kim, Nam-Sik;Jung, Duk-Young
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.23-33
    • /
    • 2011
  • In this study, a CFPBS (Cone-type Friction Pendulum Bearing System) was developed which controls the acceleration delivered to the structure to prevent damage and degradation of the critical communication equipment in case of an earthquake. The isolation performance of the CFPBS was evaluated by numerical analysis. The CFPBS was manufactured in the shape of a cone differenced from the existing FPS (Friction Pendulum System), and a pattern was engraved on the friction surface. The natural frequencies of the CFPBS were evaluated from a free-vibration test with the seismic isolator system consisting of four CFPBSs. In order to verify its earthquake-resistant performance, a numerical analysis program was created from the equation of the CFPBS induced from the equations of motion. A simplified theoretical equation of the CFPBS was proposed to manufacture the equipment which could demonstrate the necessary performance. Artificial seismic waves satisfying the maximum earthquake scale of the Korean Building Code-Structural (KBC-2005) were created and verified to review the earthquake-resistant performance of the CFPBS by numerical analysis. The superstructural mass of the CFPBS and skew angle of the friction surface were considered for numerical analysis with El Centro NS (1940), Kobe NS (1995) and artificial seismic waves. The CFPBS isolation performance evaluation was based on the results of numerical analysis and the executed comparative analysis between the results from numerical analysis and the simplified theoretical equation under the same conditions.

Shaking Table Tests of 1/3-Scale 3-Story Wet-Jointed Precast Concrete Large Panel Box Model (1/3축소 3층 습식접합 프리캐스트 콘크리트 대형판 입체모델의 진동대 실험)

  • 이한선
    • Magazine of the Korea Concrete Institute
    • /
    • v.5 no.1
    • /
    • pp.115-127
    • /
    • 1993
  • 본 연구의 목적은 프리캐스트 콘크리트(P.C) 대형판 아파트 구조물에 대한 우리나라 내진설계기준안 및 지침을 수립하기 위해 필요로 하는 정보를 취득하는데 있다. 이것은 실제 지진과 유사한 진동을 발생시키는 진동대를 사용하여 P.C대형판 구조물의 거동을 분석관찰함으로써 달성되었다. 여기에 사용된 시험체중의 하나는 습식접합 1/3 축소 3층 입체 P.C모델이었다. 지진파를 일으키기 위해 4mx4m 크기의 진동대가 사용되었다. 또한 선택한 입력지진가속도파는 Taft N21E 성분기록지진파로서 최대지진가속도(PGA)는 원하는 지진세기수준에 따라 조정되었고 시간축으로는 동적상사성법칙에 따라 축소되었다. 이 P.C모델의 진동대 실험을 통해 얻은 결과를 근거로 하여, 근거로 하여 다음과 같은 결론을 도출하였다. (1)이 시험체에 관한한, 지진안전계수는 7-8정도로 나타났으며, (2)이 P.C모델이 감쇠계수는 대체로, 철근콘크리트구조물 감쇠계수의 두배에 해당하는 값인 8%정도이며, (3) 이 모델은 접합부의 벌어짐과 미끄러짐에 의한 에너지소산을 통해서 2-3정도의 전체적인 변위연성비를 보여주었다.

Evaluation of Peak Ground Acceleration Based on Seismic Design Standards in Sejong City Area Using Gyeongju-Pohang Type Design Seismic Waves (경주·포항형 설계지진파를 활용한 세종시 지역의 내진설계기준 지표면최대가속도 성능평가)

  • Oh, Hyun Ju;Lee, Sung Hyun;Park, Hyung Choon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.41-48
    • /
    • 2024
  • In 2017, the Ministry of the Interior and Safety conducted research for the revision of seismic design standards and performed studies on standard design response spectra. As a result, the Common Application Guidelines for Seismic Design Standards were introduced, and these guidelines have been implemented in the national design standards of the Ministry of Land, Infrastructure, and Transport for practical use. However, it should be noted that the research for proposing standard design response spectra during the 2017 revision was conducted before the occurrence of the significant seismic events in South Korea, such as the 2016 Gyeongju Earthquake and the 2017 Pohang Earthquake. To account for these recent major earthquakes, this study adjusted the standard design spectra based on the records of the 2016 Gyeongju Earthquake and the 2017 Pohang Earthquake and conducted ground response analyses accordingly. The results revealed variations in peak ground acceleration (PGA) at the ground surface even within the same ground classification. It was confirmed that this variation can lead to overestimation or underestimation of seismic loads.

Design of a Low-rise RC Building with Damping System (저층 철근콘크리트 건축물의 제진 구조 설계)

  • Lee, Eun-Jin;Hyoun, Chang-Kook;Choi, Ki-Sun;You, Young-Chan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.454-457
    • /
    • 2011
  • 본 논문에서는 국내에서 아직 기준이 마련되지 않은 제진설계에 대한 접근을 소개하였다. ASCE 7-05 기준에 근거하여 국내 5층 규모의 철근콘크리트 신축 건물에 제진 설계를 수행하였다. 우리나라의 현행 기준을 만족하면서 효과적인 제진 시스템 설계를 위한 방법을 소개한다. ASCE 7-05 기준에서는 제진 구조물 해석 시 부재력이 공칭강도의 1.5배를 초과하지 않은 경우 경계비선형 해석을 허용하고 있다. 이 때의 제진 설계 프로세스는 기존의 중력하중 및 등가정적하중의 75%에 의한 단면을 가정하여 부재설계를 실시하고, 선형 시간이력 해석을 통해 제진장치 및 가새를 설계한다. 이후 우리나라 실정에 맞도록 보정된 인공 지진파를 입력하여 경계비선형 해석을 실시하고, 밑면 전단력 및 층간변위 등의 만족여부를 검토한다. 이 때 목표성능을 완전탄성설계 또는 유사탄성설계로 정하여 목표성능을 만족하는지도 검토하여야 한다. 본 논문에 적용한 신축 건물은 유사탄성 설계를 위해 경계비선형 해석을 실시하였고, 가장 효과적인 제진 설계를 위해 댐퍼의 종류, 설치방법, 개수, 변위 증폭비 등을 변수로 한 case study를 진행하였다. 해석 결과 목표성능을 만족하는 범위 내에서 가장 효과적인 제진 설계는 점성댐퍼, 이층 토글형태, 증폭비 2.0, 총 8개의 댐퍼를 설치하는 것으로 나타났다.

  • PDF

Seismic Energy Demand of Structures Depending on Ground Motion Characteristics and Structural Properties (지반 운동과 구조물 특성에 따른 구조물의 에너지 요구량)

  • Choi, Hyun-Hoon;Kim, Jin-Koo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.3 s.43
    • /
    • pp.59-68
    • /
    • 2005
  • The energy-based seismic design method Is more rational in comparison with current seismic design code in that it can directly account for the effects of cumulative damage by earthquake and hysteretic behavior of the structure. However there are research results that don't reach a consensus depending on the ground motion characteristic and structural properties. For that reason in this study the influences of ground motion characteristics and structural properties on energy demands were evaluated using 100 earthquake ground motions recorded in different soil conditions, and the results obtained were compared with those of previous works. Results show that ductility ratios and sue conditions have significant influence on input energy. The results show that the ratio of hysteretic to input energy is considerably influenced by the ductility ratio, damping ratio, and strong motion duration, while the effect of site condition is insignificant.

Analysis on the Dynamic Behavior of Breakwater with the DCM Method Using the Shaking Table Test (진동대시험을 이용한 DCM공법에 따른 방파제의 동적거동 분석)

  • Kim, Youngjun;Park, Innjoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.5
    • /
    • pp.25-32
    • /
    • 2022
  • As recently, there have been two earthquakes with a magnitude of 5.0 or greater in Korea and the number of smaller earthquakes has increased, a lot of research and interest in earthquake-resistant design are increasing. Especially, the Pohang earthquake has also raised interest in earthquake-resistant design of port facilities. In this study, experiments and analysis were conducted on the dynamic behavior of upright and inclined breakwaters during earthquakes among port structures through the 1g shaking table test. To this end, three seismic waves were applied to the model to which the similarity law (scale effect) was applied: long period (Hachinohe), short period (Ofunato) and artificial seismic waves. The acceleration and displacement of the upright and inclined breakwaters were analyzed according to whether the DCM method was reinforced during earthquakes based on the results of shaking table test. As the result, the dynamic behavior of the upright and inclined breakwater shows a tendency to suppress the amplification of acceleration as bearing capacity and rigidity increase when DCM method is reinforced.

Sensitivity Analysis of Rockfill Input Parameters Influencing Crest Displacement of CFRD Subjected to Earthquake Loading (지진하중을 받는 CFRD 정상부 변위에 영향을 미치는 사력재료 입력물성에 대한 민감도분석)

  • Ha, Ik-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.1 s.53
    • /
    • pp.1-9
    • /
    • 2007
  • The purpose of this study is to carry out the quantitative sensitivity analysis on rockfill material influencing the dam crest displacement of CFRD(Concrete-Faced Rockfill Dam) subjected to earthquake loading. The total 105 dynamic numerical analyses (2 input earthquake, 2 magnitudes for each earthquake. 27 rockfill material property combinations obtained from large triaxial tests) on CFR type "D" dam in operation were conducted. The global sensitivity analysis was carried out using the results of numerical analysis. From the results of sensitivity analysis, It was found that the crest settlement of the CFR type dam subjected to earthquake was absolutely affected by the shear modulus of rockfill material irrespective of the input earthquakes and the maximum acceleration of each earthquake. Also, it was found that the horizontal displacement of the dam crest was highly affected by the shear modulus of rockfill material though the extent of effect on that was smaller than the settlement and the extent of effect depended on the input earthquakes and the maximum acceleration of each earthquake. On the contrary, it was found that the effect of friction angle was negligible.

Derivation of Dynamic Characteristic Values for Multi-degree-of-freedom Frame Structures based on Frequency Response Function(FRF) (주파수응답함수 기반 다자유도 골조 구조물의 동특성치 도출 및 구조모델링 적용 )

  • So-Yeon Kim;Min-Young Kim;Seung-Jae Lee;Kyoung-Kyu Choi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.4
    • /
    • pp.1-10
    • /
    • 2023
  • In the seismic design of structures, seismic forces are calculated based on structural models and analysis. In order to accurately address the dynamic characteristics of the actual structure in the structural model, calibration based on actual measurements is required. In this study, a 4-story frame test specimen was manufactured to simulate frame building, accelerometers were attached at each floor, and 1-axis shaking table test was performed. The natural period of the specimen was similar to that of the actual 4 story frame building, and the columns were designed to behave with double-curvature having the infinite stiffness of the horizontal members. To investigate the effects seismic waves characteristics, historical and artificial excitations with various frequencies and acceleration magnitudes were applied. The natural frequencies, damping ratios, and mode shapes were obtained using frequency response functions obtained from dynamic response signals, and the mode vector deviations according to the input seismic waves were verified using the Mode assurance criterion (MAC). In addition, the damping ratios obtained from the vibration tests were applied to the structural model, and the method with refined dynamic characteristics was validated by comparing the analysis results with the experimental data.

Nonlinear Response Spectra of Artificial Earthquake Waves Compatible with Design Spectrum (설계용 스펙트럼에 적합한 인공지진파에 의한 비선형 응답 특성의 분석)

  • Jun, Dae-Han;Kang, Pyeong-Doo;Kim, Jae-Ung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.5 s.51
    • /
    • pp.63-71
    • /
    • 2006
  • In seismic response analysis of building structures, the input ground accelerations have considerable effect on the nonlinear response characteristics of structures. The characteristics of soil and the locality of the site where those ground motions were recorded affect on the contents of earthquake waves. Therefore, it is difficult to select appropriate input ground motions for seismic response analysis. This study describes a generation of artificial earthquake wave compatible with seismic design spectrum, and also evaluates the nonlinear response spectra by the simulated earthquake motions. The artificial earthquake wave are generated according to the previously recorded earthquake waves in past earthquake events. The artificial wave have identical phase angles to the recorded earthquake wave, and their overall response spectra are compatible with seismic design spectrum with 5% critical viscous damping. Each simulated earthquake wave has a identical phase angles to the original recorded ground acceleration, and match to design spectra in the range of period from 0.02 to 10.0 seconds. The seismic response analysis is performed to examine the nonlinear response characteristics of SDOF system subjected to the simulated earthquake waves. It was concluded that the artificial earthquake waves simulated in this paper are applicable as input ground motions for a seismic response analysis of building structures.

Seismic Fragility Evaluation of Chimney Structure in Power Plant by Finite Element Analysis (유한요소 해석을 통한 발전소 연돌 구조물의 지진취약도 분석)

  • Kwon, Gyu-Bin;Kim, Jin-Sup;Kwon, Min-Ho;Park, Kwan-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.276-284
    • /
    • 2019
  • Seismic research on bridges, dams and nuclear power plants, which are infrastructure in Korea, has been carried out since early on, but in the case of structures in thermal power plants, research is insufficient. In this study, a total of 192 dynamic analyzes were performed for 16 actual seismic waves and 12 PGAs. As a result, the probability of failure increased as the PGA value increased for each applied seismic wave, but it was different for each seismic wave. As a result, at 0.22G, the ratio of the compressive limit reached to the limit state was 25% and the ratio of the relative displacement reached the limit state was 13%. So, the probability of collapse due to compressive failure Is higher. Therefore, the fragility curve of the chimney which is the subject of this study can be used as a quantitative basis to determine the limit state of the target structure when an earthquake occurs and to be used for the safety design of the thermal power plants.