• Title/Summary/Keyword: 설계시험평가

Search Result 1,945, Processing Time 0.032 seconds

Accelerated aging test procedures for SRAM PUFs (SRAM PUF 가속 노화 시험 절차 수립)

  • Moon-Seok Kim;Seung-Bae Jeon;Jun-Young Park
    • Convergence Security Journal
    • /
    • v.24 no.3
    • /
    • pp.59-65
    • /
    • 2024
  • This research proposes an accelerated aging test procedure for Static Random Access Memory Physically Unclonable Functions (SRAM PUFs). PUFs utilize semiconductor process variations to serve as a hardware security feature, akin to semiconductor device fingerprints. Thus, the proposed accelerated aging test simulates a semiconductor's 10-year lifecycle, enabling the prediction of PUF characteristics after a decade of use, which is crucial for verifying the safety and stability of SRAM PUFs. This research introduces test procedures that simulate 10 years of aging in approximately 9 days by setting temperature and voltage higher than operational environments. These procedures allow for the quantitative evaluation of SRAM PUF characteristics. This research is expected to contribute to the advancement of design and maintenance testing techniques for systems based on SRAM PUFs.

Assessment of the Rock Strength using Borehole Acoustic Scanner (초음파 주사검층 방법을 이용한 암반강도 평가에 관한 연구)

  • Lee Kwangbae;Heo Seung;Song Young-Soo;Song Seungyup;Kim Haksoo
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.4
    • /
    • pp.225-233
    • /
    • 2004
  • The purpose of this study is to provide the geo-technical information by assessment of the in-situ rock strength using the reflected wave energy and travel time data acquired by the borehole acoustic scanner. In order to compare and analyze the relationship between the uniaxial compressive strength and the reflected wave energy, the laboratory test and the borehole acoustic scanning were conducted for the set of specimens, such as mortar, concrete, and rock samples which have different rock type. Finally, we verified the applicability of the reflected wave energy acquired by the borehole acoustic scanner to quantitatively estimate the in-situ rock strength.

복사 전자기장에 대한 전자파내성 측정시스템

  • 정연춘
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.5 no.2
    • /
    • pp.67-78
    • /
    • 1994
  • 1996년부터 유럽연합을 중심으로 전자파내성(Electromagnetic immunity; 흔히 군사규격에서는 전자파감응성(electromagnetic susceptibility)이라 함) 규제가 본격적으로 시작될 전망이다. 이러한 전자 파내성 규제는 우리가 과거 '80년대 초에 경험했던 전자파방출(electromagnetic emission; 흔히 electro- magnetic interference 라고도 표현한다) 규제에 비해 규제주파수가 대폭 확장됨(9KHz - 1GHz .rarw. 50/60 Hz - 40 GHz)은 물론, 규제항목도 크게 늘어나기(2개 항목 .rarw. 11개 항목)때문에 본격 규제가 시작되면 우리 산업체에 큰 피해를 초래할 것으로 우려된다. 특히 "복사 전자기장에 대한 전자파내성 요구사항"은 일부 전자파내성 측정항목을 포함하고 있던 안전규 격 등에서도 다루고 있지 않던 것으로서 우리에게는 매우 생소한 항목이다. 이 항목은 과거 미국의 군사 규격등에서 요구했던 항목인데, 앞으로 각국의 상용규격에도 대폭 추가될 것으로 보인다. 이러한 규제는 우리의 생활환경에서 결코 빼놓고 생각할 수 없는, 동시에 가장 큰 전자파장해원인 의도적 복사로서의 방 송신호 및 각종 무선통신 신호에 대해 전기, 전자기기가 전자파내성을 갖고, 성능저하나 오동작을 유발하 지 않아야 함을 요구하는 것이다. 이러한 항목의 평가를 위해서는 대형 시험환경(EMS chamber)과 표준 전자기장 발생장치(signal genera- tors + high power amplifiers), 그리고 오동작 모니터링 장치(monitorring equipments) 등이 필요하기 때 문에 평가시스템 구성에 막대한 비용이 소요된다. 따라서 시스템 구성에 매우 신중을 기해야 하며, 관련 국제표준화규격을 사전에 철저히 이해하여 관련 시험검사를 위한 투자계획을 수립하는 것이 바람직하다. 본 고에서는 복사 전자기장에 대한 대표적인 국제표준화규격을 소개하고, 나아가서 그러한 항목의 평가 시스템의 설계 및 구현에 대해서 설명할 것이다.

  • PDF

Design and Implementation of An Educational Evaluation System Providing Free Movement between Questions (문항간 이동이 자유로운 교육평가 시스템의 설계 및 구현)

  • Hong, Ki-Cheon;Yang, Hee-Yeon
    • Journal of The Korean Association of Information Education
    • /
    • v.11 no.2
    • /
    • pp.147-155
    • /
    • 2007
  • Paper & pencil test provides limited informations about student. So many web-based computerized test systems are developed and tried. But These systems have drawbacks that cannot visit previous or next problems freely. So These systems cannot get deep informations such as elapsed time of each problem, history of answer modification, the number of visit time of each problem. These deep informations are very important in educational evaluation area. Therefore we develop educational evaluation system can get these deep informations including basic informations. And then we apply paper & pencil test and our system to 67 students, and execute survey. The reason of survey is to ascertain availabilty of our system.

  • PDF

Reliability and Accuracy Analyses of Prediction Equations for Settlement Calculation of Shallow Foundations Constructed on Sandy Soils (사질토 지반에 시공된 얕은 기초 침하예측식의 신뢰도 및 정확도 분석)

  • Lim, Yu-Jin
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.3
    • /
    • pp.77-86
    • /
    • 2008
  • A database program is constructed by collecting all information related to shallow foundations such as measured load-settlement data, foundation shapes and sizes, properties of soils under the foundation and various measured data obtained from field investigation methods including CPT, PMT and SPT etc.. Based on the database program, a special program module is developed for performing statistical analyses of reliability and accuracy of predicting equations used for calculation of settlement of the shallow foundations. Special interests are focused not only on the settlement, but also on the settlement to width ratio (s/B). Results of the reliability and accuracy analyses on five available settlement equations are provided. Conclusions based on the provided results can be confirmed by extending number of related reliable data about the shallow foundations and can be adapted as guidelines for design of the shallow foundations.

Fatigue of SS490A and SS400 Corroded Specimens (SM490A와 SS400 대기부식 시편의 피로 특성 평가)

  • Goo, Byeong-Choon
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.725-731
    • /
    • 2009
  • For structural design and diagnosis, quantitative relationship between corrosive degradation and variation of mechanical properties such as tensile strength and fatigue strength is needed. But it is difficult to find experimental data associated with corrosive degradation of structural structures in the literature. In this study, first of all I established the atmospheric corrosion test procedure. And using specimens of SM490A and SS400 on the atmospheric corrosion test bed, I carried out tensile and fatigue tests at regular intervals. And we studied the effect of post-weld heat treatment on the tensile and fatigue behaviour. It is found fatigue strength decreases as the atmospheric corrosion period increases.

Evaluation of the Application and Analysis Method at Seismic Design of Dam (댐의 내진설계시 해석방법과 그 적용성 평가)

  • Hwang, Seong-Chun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4239-4249
    • /
    • 2011
  • In the country with frequent earthquakes like Japan, resistance to earthquake is assessed on the basis that Dam body's Face slab is destroyed by concentrated stress. In our country this kind of modeling and analysis is not yet definitely established. This paper performed pseudo static analysis and dynamic analysis for CFRD and evaluated reliability with the results of Shaking Table Test. The Seismic coefficient method, modified seismic coefficient method, Newmark method of Pseudo-static analysis and frequency domain response analysis, time domain history analysis of dinamic analysis were used. The analysis results were differ between analysis method, but the trends of acceleration and displacement were good agreement with the results of shaking table test.

Preliminary assessment of groundwater artificial recharge effect using vertical wells based on a numerical model (수치모델을 활용한 수직정의 지하수 인공함양 효과 예비 평가)

  • Choi, Myoung-Rak;Hwang, Chan-Ik;Kim, Gyoo-Bum
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.290-290
    • /
    • 2020
  • 연구지역인 충청남도 홍성군 갈산면 신곡마을은 상시 가뭄지역으로서 농번기 물부족을 겪고 있으며, 물 확보의 수단으로서 지하수 인공함양이 고려되고 있다. 본 연구에서는 수치모델을 이용하여 수직정 방식의 지하수 인공함양시 주입 효과를 예비 평가하였다. 모델 지역은 가로 세로 2,450 × 2,350 m로서 10 × 10 m 간격의 격자로 구성하였으며, 현장에서 실시된 지하수위 조사 및 9공의 시추조사, 1개공의 양수시험 결과로부터 수리전도도, 지층분포 등을 구성하였다. 정류모델결과, 실측 및 예측 지하수위의 표준오차(Standard error of the estimate)는 0.53 m, 표준화제곱근오차(Normalized RMS)는 6.79%, 상관계수는 0.99%로 나타났다. 수직정을 통한 주입 효과를 평가하기 위하여, 주입량을 5 ㎥/d, 10 ㎥/d, 15 ㎥/d, 20㎥/d, 주입기간을 1일, 3일, 7일, 우물의 개수를 1개, 3개, 5개일 때 등 다양한 조건하에서의 부정류 모델을 수행하였다. 이로부터 주입의 효과인 지하수위 상승량 및 상승 범위 등을 토대로 물 부족 기간의 인공함양 시나리오(주입정의 위치, 갯수, 심도, 기간 등)를 예비적으로 제시하였으며, 추후 정밀 모델 및 실제 현장 주입 시험 등을 토대로 인공함양 설계를 추진할 예정이다.

  • PDF

Alternative Method of Determining Resilient Modulus of Subbase Materials Using Free-Free Resonant Column Test (현장공진주시험을 이용한 보조기층 재료의 대체 $M_R$ 시험법)

  • Kweon, Gi-Cheol;Kim, Dong-Su
    • International Journal of Highway Engineering
    • /
    • v.2 no.2
    • /
    • pp.149-161
    • /
    • 2000
  • The stiffness of the subbase materials is represented by the resilient modulus, $M_R$, which are very important properties in the mechanistic design of flexible pavement system. However, the cyclic $M_R$ testing method is too complex, expensive, and time consuming to be applicable on a production basis. In this study, the alternative $M_R$ testing technique for subbase materials was developed using a free-free resonant column (FF-RC) test considering deformational characteristics of subbase materials. To estimate the deformational characteristics of subbase materials, effects of strain amplitude and mean effective stress on modulus of subbase materials were investigated. The $M_R$ values determined by alternative testing procedures matched well with those determined by standard $M_R$ test, showing the capability of the proposed methods being used in determining $M_R$ values.

  • PDF

Response Dominant Frequency Analysis for Scour Safety Evaluation of Railroad Piers (철도 교각의 세굴 안정성 평가를 위한 응답 지배주파수 분석)

  • Jung, Hyun-Seok;Lee, Myungjae;Yoo, Mintaek;Lee, Il-Wha
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.11
    • /
    • pp.83-95
    • /
    • 2020
  • In order to evaluate the stability of the geo-structure of railway bridge, the response dominant frequency was analyzed based on a series of impact vibration load test results. The specifications of the experiment piers were obtained by referring to the completion design data, and when data was missing, a field study was conducted. The impact vibrations test according to the scouring progress was carried out at one pier scheduled to be abandoned, and it was confirmed that the response dominant frequency can be utilized as an evaluation index for scour. In addition, the response dominant frequency was measured through an impact load test at 46 piers in 5 bridges in operation, and the scour safety of the bridge was evaluated by comparing it with the japanese proposal formula.