• Title/Summary/Keyword: 설계시험평가

Search Result 1,945, Processing Time 0.03 seconds

Evaluation of Reinforcing Effects of Pressure-Injected Grouting Nail in Weathered Rock (풍화암 사면에서의 압력분사 그라우팅 네일 보강 효과 연구)

  • Hwang, Young-Cheol;Kim, Nak-Young
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.1
    • /
    • pp.47-55
    • /
    • 2002
  • The slope reinforcing method utilized in this paper reinforces the ground overall by means of filling borehole as well as permeating grout material into ground by injecting it through the grouting pipe. In order to reflect these characteristics to design, not only the ground reinforcing effect by the structural material itself but also the ground strength improvement effect by the grouting injection must be quantitively evaluated. But precedent research of it has been insufficient. Therefore, the slope reinforcing method was applied to the weathered rockmass slope situated in the highway in order to analyze reinforcing effect and the instrumentation of slope was performed. Through analysis of this field test, the slope reinforcing method was proved to be effective and back analysis method based on instrumentation values of slope was proposed to apply to reinforcing design. In this paper, the effectiveness of reinforcing method was certified through proposed back analysis.

  • PDF

Stiffness Degradation and Unconfined Strength of the Chemically Grouted Sand Subjected to Cyclic Shear (반복전단을 받는 고화 처리토의 강성저하와 일축압축강도)

  • Kwon, Youngcheul;Lee, Bongjik;Bae, Wooseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.5
    • /
    • pp.23-29
    • /
    • 2007
  • The performance of the improved soil against liquefaction depends upon the chemical density, and it has been decided on the basis of the unconfined compressive strength of the improved soil up to date. On the other hand, several authors have proposed that the stiffness degradation could be treated as the clue for the judgment of the possibility of liquefaction. In this study, therefore, the stiffness degradation of the improved soil was estimated as the resistance against liquefaction by using the strain controlled cyclic triaxial test equipment. Based on the test results, it is concluded that the chemically treated sand can resist against the liquefaction in aspect of the reduction in effective stress and in the stiffness. Furthermore, even in the case of low chemical density, such as 2% in this study, has enough liquefaction resistance when compared with the 5~6% which often used in practical design. Considering this fact, the design of chemical density based on the unconfined strength can lead the overestimation in chemical density, and chemical density can be reduced when considering the stiffness reduction shown in this study.

  • PDF

Estimation of Over Consolidation Ratio in Southern Coasts (남해안 지역의 과압밀비에 대한 평가)

  • Kang, Seokbeom;Heo, Yol;Bae, Wooseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.4
    • /
    • pp.93-104
    • /
    • 2012
  • Efforts to understand and develop reasonable analysis methods for the uncertainty of ground have been made since the 20th century, and the concept of safety factor has been used. However, this concept has limitation in measuring the relative reliability of ground structures because the representative values of the actually used factors have uncertainty. Nevertheless, there is no method to completely remove uncertainty. In most cases, the ground investigation results in Korea are not enough for applying such statistical methods. Furthermore, performing a design without accurate investigation of consolidation state even though consolidation characteristics such as settlement and consolidation velocity vary greatly by the consolidation history can lead to many problems. Therefore, in this paper, as part of the effort to reduce the uncertainty of design around over consolidation ratio among the consolidation factors, the consolidation state was assessed on the basis of the results of high-quality laboratory tests that were performed in Gwangyang and Busan in the southern coast of Korea. Furthermore, consolidation characteristics such as over consolidation ratio by depth were proposed for different regions through statistical processes such as the test of normality and the removal of abnormal values to reduce the uncertainty of design parameters.

Drain Capacity of PVD Filter Considering the Field Condition (현장 토질특성을 고려한 연직배수재 필터의 성능평가)

  • Han, Sung-Su;Jeong, Kyeong-Han
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.1
    • /
    • pp.33-38
    • /
    • 2007
  • PVD (Prefabricated Vertical drain) consists of filter and core. An effective PVD has two basic filtration functions ; first to retain soil particle ; and second, to allow water to pass from the soil into the PVD core without clogging or blinding. Clogging which reduces the permeability of the geotextile filter jacket is caused by fine particles penetrating into the geotextile filter jacket in relatively low permeability soil conditions. As clogging performance increases gradually, excess pore water flow from soil is resisted and finally consolidation delays. Current soil-geotextile filter system criteria are generally based on relationships between a representative pore size of the geotextile and particle size of the soil. In Korea, PVD geotextile filter system criteria have been applied by only testing AOS (Apparent Opening Size) of filters without evaluating the filtration and clogging performance on soil-geotexile filter systems. Therefore, the filtration tests on soil-geotexile filter systems were conducted in order to evaluate the filtration and clogging performance with 3 kinds of geotextile filters. On these tests, we have applied geotextile filter system criteria on PVD in ${\bigcirc}{\bigcirc}$ sites.

  • PDF

An Evaluation of Tensile Design Criteria of Cast-In-Place Anchor by Numerical Analysis (수치해석에 의한 직매형 앵커기초의 인장설계기준 평가)

  • Suh Yong-Pyo;Jang Jung-Bum
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.3
    • /
    • pp.303-309
    • /
    • 2005
  • Numerical analysis is carried out to identify the appropriateness of the design codes that is available for the tensile design of fastening system at Nuclear Power Plant (NPP) in this study. This study is intended for the cast-in-place anchor that is widely used for the fastening of equipment in Korean NPPs. The microplane model and the elastic-perfectly plastic model are employed for the quasi-brittle material like concrete and for the ductile material like anchor bolt as constitutive model for numerical analysis and smeared crack model is employed to simulate the clack and damage phenomena. The developed numerical model is verified on a basis of the various test data of cast-in-place anchor. The appropriateness of both ACI 349 Code and CEB-FIP Code is evaluated for the tensile design of cast-in-place anchor and it is proved that both design codes give a conservative results for real tensile capacity of cast-in-place anchor.

Finite Element Analysis of Pipe Whip Restraint Behavior Under Jet Thrust Forces (유체 분사 추진력을 받는 배관 휩 구속장치 거동에 관한 유한요소해석)

  • Sugoong Koh;Lee, Young-Shin
    • Nuclear Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.353-360
    • /
    • 1993
  • Many types of pipe whip restraints are installed to protect the structural components from the anticipated pipe whip phenomena of high energy lines in nuclear power plants. It is necessary to investigate these phenomena accurately in order to design the pipe whip restraints properly and/or to evaluate the acceptability of the pipe whip restraint design. Various research programs have been conducted in many countries to develop analytical methods and to verify the validity of the methods. In this study, various types of finite elements in ANSYS[1], the general purpose finite element computer program, was used to simulate the postulated pipe whips to obtain impact loads and the calculated results were compared with the specific experimental results from the sample pipe whip test for the U-shaped pipe whip restraints. Some calculational models, having the gap element or the spring element between the pipe whip restraint and the pipe line, give reasonably good transient responses of the restraint forces compared with the experimental results, and could be useful in evaluating the acceptability of the pipe whip restraint design.

  • PDF

The Hydrological Survey of the Seolmacheon Catchment during 2011 year (2011년 설마천 유역의 수문조사)

  • Kim, Dong-Phil;Lee, Nam-Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.678-682
    • /
    • 2012
  • 본 연구는 한국건설기술연구원의 주요사업인 "산지하천 유역의 홍수예측을 위한 수문조사(2011~2015년)"의 Test-bed 유역중의 하나인 설마천 유역(경기도 파주시 적성면)을 운영하면서 신뢰성 있는 수문자료를 지속적으로 획득함과 동시에 산지하천 유역의 홍수량 예측과 재해방지 설계기법을 개선하고 수문정보를 제공하는데 있다(Test-bed 유역중의 또 하나인 차탄천 유역은 2011년 수문관측 기반구축 완성). 이를 위하여 2011년에도 지속적인 수문조사를 하였으며, 수문자료의 품질 향상을 위한 관측기기의 유지관리와 수집된 자료의 처리절차를 통하여 신뢰성 있는 수문자료를 생성하고, 이들 자료를 바탕으로 유역의 수문특성을 분석하였다. 또한 홍수량 예측과 재해방지 설계기법 개선을 위해서는 관련 기술조사, 평가와 취약 설계인자를 도출하였으며, 정량화를 위한 시험 및 조사방법을 결정하는 과정을 진행하고 있다. 설마천-차탄천 수문정보시스템(http://seolmacheon.kict.re.kr)은 Test-bed 유역(설마천 유역 이외에 차탄천 유역 포함)에서 생성되는 수문자료를 수집, 저장, 공유하는 기능을 포함하고, 홍수예측 모형(집중형 모형)과 강우레이더 자료(RDAPS 자료)를 결합한 산지하천의 홍수예측을 모의할 수 있는 기능을 추가하였으며, 향후 모의의 정도를 개선하고자 다른 모형과 다른 강우레이더 자료 도입을 목표로 진행할 예정이다. 그리고 Test-bed 유역을 기반으로 한 홍수량 예측 모형의 적용성 평가를 통해 중 소규모 산지하천 유역에 적합한 실시간 홍수예보 시스템 개발과 유역 수문조사 지침서 작성을 통해 가이드를 제시하고자 한다. 2011년 설마천 유역에서 생성된 자료로는 6개 우량관측소의 우량자료, 2개 수위관측소의 하천수위 및 지하수위, 유량측정성과 등이 있으며, 이로부터 산정된 유역평균우량과 유량자료 등이 있다. 확정된 강우-유출자료를 이용하여 강우의 호우사상 분석(강우강도, 지속기간), 강우의 지속기간별 최대강우량, 강우의 시 공간 분포 특성 분석, 월별 유출 및 주요 호우사상의 유출특성 분석 등 기본적인 강우-유출 특성을 분석하였다. 그리고, 유량측정성과의 불확실도 분석을 통하여 측정한 유량자료의 정확도를 제고하였다. 설마천 유역에서 축적된 수문자료는 자료의 공유를 통하여 자료의 검증을 확보함과 동시에 연구성과가 수자원 개발 분야에 활용되기 위해서는 지속적이고 안정적인 자료확보와 수문관측 기술개발을 위한 노력과 투자가 더욱더 필요한 상황이다.

  • PDF

Seam Efficiency of Geotextile and Verification of Allowable Bearing Capacity of Soft Ground (토목섬유 봉합효율과 연약지반 허용지지력 현장검증)

  • Cho, Dae-Sung;Chae, Yu-Mi;Kim, Jae-Hong
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.7
    • /
    • pp.25-34
    • /
    • 2021
  • Since the dredging reclaimed land consisting of soft ground is very weak in support, the difficult and complex factors should be considered in the design to calculate accurate bearing capacity of soft ground. Recently, various reinforcement construction methods of soft ground have been designed for dredged landfills, but the stabilities are predicted by calculating conventional Meyerhof (1974) equation for trafficability in soft ground. Conventional equations increase economic costs by underestimating bearing capacity of weak ground in order to ensure constructive safety, so a modified equation has been proposed from the literature. The paper attempts to experiment and compute important factors, such as stitching fiber and seam tensile strength of geotextiles, that are not theoretically considered and can be identified in the field. In addition, The evaluation of the bearing capacity of the modified equation is verified to be stable for trafficability through the plate bearing test performed on site.

Experimental Study on the Effect of Filter Layers on Pumping Capacity and Well Efficiency in an Unconfined Aquifer (자유면대수층에서 필터층이 취수량 및 우물효율에 미치는 영향에 대한 실험적 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Choi, Yong-Soo;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.27 no.4
    • /
    • pp.405-416
    • /
    • 2017
  • This study evaluated a model unconfined aquifer comprising a sand or gravel layer, a filter layer, a pumping well, and an observation well. The model was employed in step drawdown tests and then used to assess the permeability of each test tank. The optimal yield and well efficiency were then calculated. Evaluation of yield by step in sand layer filters of equal thickness gave optimized watering rates of 22.03 L/min in the double filter and 19.71 L/min in the single filter. The double filter's yield was 115.0% that of the single filter. A comparison of double and single filters, each 10 cm thick, showed the double filter to have a maximum yield of 182.7%. Yields for the gravel layer were 73.56 L/min for a double filter and 65.47 L/min for a single filter of the same thickness; the former value is 112.3% of that of the latter. Comparison of double and single filters with 10-cm-thick gravel layers revealed that the double filter had a maximum yield of 160.9%. Results for sand wells showed the double filter to have a maximum efficiency of 70.4% and the single filter to have a minimum efficiency of 37.1%. Gravel-layer well efficiencies were >66.5% for both double and single filters (each 30 cm thick), but only 22.5% for a 10-cm-thick single filter. This study confirms that permeability improved as the filter material became thicker; it also shows that a double filter has a higher yield and well efficiency than a single filter. These results can be applied to the practical design of wells.

Development of Integrated Type Main Frame and Downhole Sonde Apparatus for Hydraulic Packer Testing in Seabed Rock under High Water Pressure (고수압 해저지반 수리특성 조사용 일체형 메인 프레임과 공내 측정장치 개발)

  • Bae, SeongHo;Kim, Jangsoon;Jeon, Seokwon;Kim, Hagsoo
    • Tunnel and Underground Space
    • /
    • v.28 no.3
    • /
    • pp.258-276
    • /
    • 2018
  • The accurate and quantitative ground information on the hydraulic conductivity characteristics of rock mass is one of the key factors for evaluation of the hydro-geological behaviour of rock mass around an excavated opening under high water pressure. For tunnel and rock structures in seabed, where the sea acts as an infinite source of water, its importance become greater with increasing construction depth below sea level. In this study, to improve the problems related with poor system configuration and incorrect data acquisition of previous hydraulic packer testing equipment, we newly developed an integrated main frame and 30 bar level waterproof downhole sonde apparatus, which were optimized for deep hydraulic packer test in seabed rock mass. Integration of individual test equipment into one frame allows safe and efficient field testing work on a narrow offshore drilling platform. For the integrated type main frame, it is possible to make precise stepwise control of downhole net injection pressure at intervals of $2.0kg_f/cm^2$ or less with dual hydraulic oil volume controller. To ensure the system performance and the operational stability of the prototype mainframe and downhole sonde apparatus, the field feasibility tests were completed in two research boreholes, and using the developed apparatus, the REV(Representative Elementary Volume) scale deep hydraulic packer tests were successfully carried out at a borehole located in the basalt region, Jeju. In this paper, the characteristics of the new testing apparatus are briefly introduced and also some results from the laboratory and in-situ performance tests are shown.