• Title/Summary/Keyword: 설계내력식

Search Result 110, Processing Time 0.032 seconds

A Study on the Ultimate Strength of Tube-Gusset Connection Considering Eccentricity (편심이 고려된 강관-가셋트 접합부의 극한 내력)

  • Kim, Woo Bum
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.2
    • /
    • pp.201-210
    • /
    • 2001
  • A numerical analysis and experimental study were performed to investigate the behavior and strength of tube-gusset connection subjected to axial and lateral forces. To investigate the behavior of the connections, experiment was conducted by applying three directional loads. Local buckling and local plastic bending deformation of the connection were observed from the test. Analytical results were compared with test results for the limited cases. Primary interests here are the effect of eccentricity on the strength of the connection. To suggest a formula for the strength of tube-gusset connection, lateral forces were replaced with equivalent wall moment and eccenrtric vertical component force of lateral force. Ultimate strength formula for the each force was proposed. Finally, nondimensionalized ultimate strength interaction relationships between the wall moment of tube($M_w$), vertical axial force($P_v$), and eccentric vertical component of lateral force($P_e$) were formulated through parametric study.

  • PDF

Ultimate Strength of Fillet-welded T-joints in Cold-formed Square Hollow Sections-chord web failure mode (냉간성형 각형강관 모살용접 T형 접합부의 최대내력(II)-주관웨브 파괴모드-)

  • Bae, Kyu Woong;Park, Keum Sung;Kang, Chang Hoon;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.3
    • /
    • pp.403-411
    • /
    • 2002
  • This paper described the ultimate strength and deformation limit of welded T-joints in cold-formed square hollow sections. Previous studies showed that the T-joint has an obvious peak load. with the failure mode of chord-web buckling at a ratio of branch width to chord width ($\beta$) of above 0.8. Similar to a T-joint with chord-flange failure mode, the strength at a certain deformation limit can be regarded as the ultimate strength of a T-joint Based on the experimental results including tests done by Kato and Zhao, the deformation limit was proposed as 3%B for $10.7{\leq}2{\gamma}(B/T){\leq}42.3$ and $0.8{\leq}{\beta}{\leq}1.0$. The strength formula of CIDECT and those of other researchers were also compared with the test results. Finally, the strength formula based on the column buckling was proposed.

Axial Loading Behaviors and ACI 440 Code Applied Ultimate Axial Strength Formula of CFRP Strengthened Circular CFT Columns (탄소섬유쉬트로 보강된 원형CFT기둥의 압축거동과 ACI 440 code를 응용한 압축내력예측식 제안)

  • Park, Jai-Woo;Hong, Young-Kyun;Choi, Sung-Mo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.1
    • /
    • pp.23-29
    • /
    • 2011
  • This study investigates the axial behavior of CFRP strengthened circular CFT columns and proposes the design formula of CFRP strengthened circular CFT columns. 10 specimens were prepared and axial loading test were conducted to investigate the retrofitting effects of CFRP composites on CFT columns. The main parameters are the number of FRP sheets and D/t ratio. Test results showed that the CFRP retrofitting enhanced the load bearing capacity of the circular CFT columns. Finally, A ACI 440 code applied ultimate axial strength formula is proposed to predict the ultimate strength of CFRP strengthened circular CFT columns. The proposed formula are good agreement with the test results.

Flexural Strength Design Equation of Concrete Filled Steel Tube(CFT) Column Reinforced by Carbon Fiber Sheet (탄소섬유쉬트로 보강한 콘크리트 충전강관(CFT) 기둥의 휨내력식)

  • Park, Jai-Woo;Hong, Young-Kyun;Hong, Gi-Soup
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.29-36
    • /
    • 2008
  • The TR-CFT(Transversely Reinforced Concrete Filled Steel Tube) column is proposed to control or at least delay the state of local buckling at the critical section by wrapping the CFT columns with a carbon fiber sheet. In this study, an equation to determine the flexural strength of TR-CFT is proposed. The ACI-318 code, in which the contribution of the confining effect in the concrete filled steel tube is not appropriately accounted for, may be conservative. Therefore, flexural strength design equations for CFT columns and TR-CFT columns are proposed based on the concrete strain-stress curve, which contributes to the confining effect. Finally, the predicted results for the CFT and TR-CFT columns are shown to be in good agreement with actual test results.

Compressive Strength of Horizontal Joints in Precast Concrete Large Panel System (대형 콘크리트 패널구조 수평접합부의 지지력 성능에 관한 연구)

  • 서수연;정봉오;이원호;이리형
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.2
    • /
    • pp.138-147
    • /
    • 1994
  • The compressive strength of horizontal joints in precast concrete large panel structures depends on parameters such as grout and panel strength, detail of joint, joint moment, width of grout column, and etc. 44 specimens were tested to investigate the effects of parameters that influence the compressive strength of horizontal joints. The design formula specified in Korean Cock for compression horizontal joints must be reviewed, because it was based on the test results of the joint types not used in Korea. In this study comparing the test results, there fore, the validity of the design formulas was evaluated and a suitable formula was proposed to predict the ultimate strengths of compression horizontal joints. The increase of ultimate strengths was not observed, even if confined the horizontal displacement of slabs and reinforced the wall edge, when the grout strength is lower than panel strength. From the comparison of test results and those by the proposed formula, it was shown that proposed formula was suitable to predict the ultimate compressive strength of horizontal joints.

The Bucking Strength and the Application of design of Design Formula of High Strength H-Shaped Section Steel Members (고강도 H형강 부재의 좌굴내력과 설계식에의 적용에 관한 연구)

  • Kim, Jin Kyong;Kim, Hee Dong;Lee, Myung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.2
    • /
    • pp.123-131
    • /
    • 2001
  • The objective of this study is to investigate the criteria of the width-to-thickness ratio and to evaluate the buckling strength of high strength steel beam-columns and to compare their buckling strength with design codes, which are the Limit State Design code and the Allowable Stress Desogn code(drift). SM520TMC and SM570Q class steels are used for high strength steels. The coupon test and the stub column test were carried out to investigate the properties of high strength steels and the stress-strain curves of stub columns. The buckling strength of high strength steel beam-columns are assessed by numerical analysis used axial force, moment and curvature relationships.

  • PDF

An Experimental Study on the Shear Strength of Chemical Anchors Embedded into Non Cracking Plain Concrete (비균열 무근콘크리트에 매입된 케미컬 앵커의 전단내력에 관한 실험적 연구)

  • Seo, Seong-Yeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.21-29
    • /
    • 2017
  • The use of post installed anchors with adhesive type has lately been increasing when it is necessary to repair, reinforce, or remodel structures. This method provides flexibility and simplicity for construction of structural members that require adhering or fixing. Meanwhile, strength evaluation of anchors with expansion type among post installed anchors systems has nearly reached setting up stage like design code through continual experimental studies for the last ten years, but analyses or experimental studies on anchor system with adhesive type are not yet sufficient. Accordingly, the designers and builders of korea depend on foreign design codes since there are no exact domestic design code they could credit. In this study, the objectives are investigating the effects on adhesive strength of anchors embedded into plain concrete by shear experiments of anchors with variables such as edge distance, anchor interval, and load direction and supplying basic data for enactment of domestic design code.

Strength and Moment-Curvature Relationship of HCFT Columns under Eccentric Load (편심압축이 작용하는 HCFT기둥에 대한 내력특성과 모멘트-곡률의 곤계)

  • 이승조;박정민;김화중
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.864-873
    • /
    • 2002
  • Recently, CFT Column has reported a lot of study result, because a CFT column has certain superior structural properties as well as good productivity, execution efficiency, and improved rigidity over existing column. However, CFT column still has problems clearing the capacity evaluation between its steel tube member and high-strength concrete materials. Also, high-strength concrete filled steel square tube column(HCFT) examined numerical value explanatorily about transformation performance(M-ø) of when short-column receives equal flexure-moment from axial stress on research for concrete. hnd, with basis assumption, executed development of analysis program of moment-curvature relation for analytic analysis of transformation performance of HCFT section that get by an experiment. This study investigated to properties of structural(capacity, curvature), through a series of experiments for HCFT with key parameters, such as strength of concrete(600kgf/$\textrm{cm}^2$), D/t ratio, slenderness ratio(λ) and concrete kinds under eccentric load. And, I executed comparative analysis with AISC-LRFD, AIJ and Takanori Sato etc. and experiment result that is capacity design formula.

Damage Distribution Rule of Weak Beam Type Multi-Story Steel Frames Influenced by Strength and Stiffness Ratios of Beam and Column (보 붕괴형 메커니즘을 가지는 강구조 다층골조의 손상분포)

  • Oh, Sang-Hoon;Ryu, Hong-Sik;Moon, Tae-Sup
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.5 s.45
    • /
    • pp.53-61
    • /
    • 2005
  • In order to evaluate the limit earthquake resistance of multi-story steel frames influenced by the strength and stiffness ratios of members, a series inelastic response analysis were carried out. From the analysis results, the damage distribution rules of multi-story steel frames were proposed. Conclusions are summarized as follows; 1)As the stiffness ratios of beam and column becomes small, the damage concentrates on the lower end of columns of the first story. 2) Considering the strength and stiffness ratios of the beam and column with weak beam type mechanism, the equations predicting the damage distribution of multi-story steel flames were proposed. 3) Through the equation which was supposed in this study, it is speculated that the damage distribution of the rigid or semirigid beam collapse type multi-story steel structure building can be predicted.

Experimental Study on the Cyclic Behavior of Modular Building with Strap Braced Load Bearing Steel Stud Walls (스트랩 브레이스를 갖는 내력벽식 모듈러건축 스틸스터드 벽체의 반복하중에 대한 거동 연구)

  • Lee, Doo Yong;Cho, Bong Ho;Kim, Tae Hyeong;Ha, Tae Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.6
    • /
    • pp.415-425
    • /
    • 2016
  • Load-bearing steel stud wall system is widely used for the middle-to-high rise modular buildings worldwide. Seismic performance is a key issue to apply load-bearing steel stud wall system to modular buildings in Korea. This study proposes a new strap braced steel stud wall system with enhanced seismic performance and design equations considering the flexural behaviour of the vertical outer studs. For the verification, two specimens with different strap braces and vertical outer stud were designed and tested. The test results showed that the total strengths were evaluated to be 1.11 to 1.18 times higher than the predicted values. Usually strap braced walls are considered to have low energy dissipation capacities. The proposed system showed enhanced seismic performance with equivalent damping of 9.42% due to the reduced pinching effects.