• Title/Summary/Keyword: 설계내력식

Search Result 110, Processing Time 0.022 seconds

Shear Resistance of BESTOBEAM Shear Connector According to the Length (BESTOBEAM 전단연결재의 길이에 따른 전단 내력 평가)

  • Ahn, Hyung Joon;Jung, In Yong;Kim, Young Ju;Hwang, Jae Sun
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.5
    • /
    • pp.483-491
    • /
    • 2015
  • Shear resistance of BESTOBEAM, which has angle as shear connector and was developed with purpose of easy construction, was tested. With the test results shear resistance design equation was proposed. Unlike angle connector of Eurocode 4, BESTO BEMA shear connector behaves like fixed-end beam. Therefor longer span of the shear connector the lower shear resistance it has. As a result, shear resistance of BESTOBEAM shear connector according to its length tends to decrease as its length gets longer. The authors proposed design equation of angle shear connector sased on the test results. The results from the test and the proposed equation match within 10% error range. Therefore the proposed equation can be used for designing shear connector of BESTOBEAM.

Shear Resistance Evaluation of Steel Grid Composite Deck Joint (격자형 강합성 바닥판 이음부의 전단내력 평가)

  • Shin, Hyun-Seop;Park, Ki-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.5290-5298
    • /
    • 2013
  • In order to apply a mechanical deck joint to the prefabricated steel grid composite decks, shear resistance of a joint composed of concrete shear key and high-tension bolt is experimentally evaluated by the push-out test. Shear resistance evaluated by the test is compared with resistance estimated by empirical and design equations based on the shear friction theory. Test results show that joint specimens bonded by epoxy have about 10% more shear resistance than specimens with strengthened shear key by steel plates, but in the case of specimens with strengthened shear key there is smaller resistance deviation than specimens bonded by epoxy. In comparison with resistances estimated by empirical and design equations, the deck joint can be safely designed. But because the existed shear resistance of deck joint is underestimated by the ACI-318, application of the LRFD design equation could be more reasonable.

The Beam-Column Strength of Concrete Filled Tubes (콘크리트 충전 각형강관 기둥재의 최대내력)

  • Lee, Myung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.391-400
    • /
    • 1997
  • The objective of this paper is to suggest formula of Concrete Filled Tube Beam-Column members maximum strength by using of numerical analysis and tests. The numerical analysis results are compared with test results for evaluating numerical analysis method. The formula of Limit State Design of Architectural Institute of KOREA is used for basic form of suggestion formula. In order to suggest formula, two methods are used. One is to use the coefficient, and the other is to use the amplified factor of material strength. The formula by two methods are compared with numerical analysis results.

  • PDF

방파제케슨에 사용하는 신형식 푸팅구조의 역학적 특성과 구조해석

  • 한국어항협회
    • 어항어장
    • /
    • s.2
    • /
    • pp.86-127
    • /
    • 1988
  • 버트리스 푸팅 케슨(Buttress footing caisson) 및 상형 푸팅 케슨의 역학특성을 해명하고 구조설계법을 검토할 목적으로 재하실험을 실시했다. 재하실험에는 배근의 제약등을 고려해서 실구조물의 1/4정도의 대형모형공시체를 사용해서 푸팅부를 중심으로 해석하기위해 푸팅에 선분포하중을 재하했다. 유한요소법에 따른 선형구조해석을 실시하여 변위, 단면력과 한계상황설계법에서의 산정식에서 얻어진 단면내력과를 비교하여 동설계법의 케슨구조물에 대한 적용성에 관하여 고찰했다. 이 보고로써 얻어진 주요한 결론은 아래와 같다. (1) 재하실험에 의하면 버트리스 푸팅공시체의 파괴형식은 버트리스부의 철근에 연한 부착할열파괴였다. 또 상형푸팅공시체에서는 푸팅부의 내면전단파괴였다. 양구조물을 설계할 때는 종래의 면외력만의 검토뿐아니라 면내력도 적절히 평가할 필요가 있다. (2) 양공시체 함께 푸팅 케슨본체와의 접합부 및 푸팅과 상자옆쪽의 벽과의 접합부에 변형이 일어나 종래의 판구조설계에서 가정하고 있는 판주변의 고정조건이 만족되지 않았다. 따라서 케슨구조물의 구조해석에서 구조전체계를 취급할 필요가 있고 부재단위에서는 단면력을 과대 또는 과소로 산정할 우려가 있다. (3) 철근강복시정도까지는 구조전체계를 모델화한 유한요소법에 의한 선형구조해석결과와 실험결과가 잘 일치했다. (4) 한계상태설계법에서의 굽음내력, 전단내력 및 구열폭의 산정식은 실험결과와 비교해서 어느쪽이나 안전측의 치를 부여했다.

  • PDF

Shear Strength of Anchors under Load Applied Angle and a Group Anchors at an Edge (앵커간격 및 하중방향에 따른 앵커의 전단내력)

  • Kim, Sung-Yong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.3 no.3 s.10
    • /
    • pp.133-141
    • /
    • 2003
  • This study concerns the prediction of shear capacity, as governed by concrete breakout failure of the anchors under load applied angle and an group anchors at an edge and installed in uncracked, unreinforced concrete. For this purpose, the methods to evaluate the shear capacity of the anchors in concrete are summarized and the experimental data are compared with capacities by the two present methods: the method of ACI 349-90 and concrete capacity design (CCD) method.

Shear Capacity of Composite Basement Walls (합성 지하벽의 전단성능)

  • 김성만;이성호;서수연;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.3
    • /
    • pp.321-330
    • /
    • 2002
  • This paper presents the experimental results of composite basement wall in which H-pile and reinforced concrete wall are combined using shear connector Twelve specimens are tested to evaluate the shear capacity of the wall. Main variables in the test are composite ratio, distribution of shear connector, thickness of wall, shear-span ratio, and shear reinforcement. Test results indicate that the shear capacity of test specimens varies with the foregoing variables except the composite ratio. The results are compared with strengths predicted using the equations of ACI 318-99, Zsutty, and Bazant. Based on this investigation, a method for predicting the shear strength of composite basement walls is proposed.

Estimate of Bolt Connection Strength of Reinforced Glulam using Glass Fiber (유리섬유 보강집성재 볼트 접합부 전단내력 예측)

  • Kim, Keon-ho;Hong, Soon-il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.1
    • /
    • pp.67-74
    • /
    • 2016
  • The yield shear strength of bolt connection in glass fiber reinforced glulam was predicted using a design-based equation, and was compared to the empirical yield shear strength. For the predicted equation, the mechanical properties of member (the elastic modulus, Poisson's ratio, shear modulus) was tested. The fracture toughness factor ($K_{ft}$) of glass fiber reinforced glulam was reflected to the revision of the design equation of bolted connection. The compressive strength properties to grain direction was influenced by annual ring angle and width of lamina. Compared with the revised yield shear strength of reinforced glulam, it was tended to be similar to the empirical yield shear strength on the diameter of bolt and the reinforcements. The revised yield shear strength from proposed formula of KBC was most appropriately matched in the bolt connection of the glass fiber reinforced glulam.

Evaluation of Design Formulae for T-joints on the Branch Plate and Hollow Steel Sections welded connections (지관 플레이트가 주관에 용접된 각형강관 접합부의 설계내력 평가에 관한 연구)

  • Park, Keum Sung;Bae, Kyu Woong;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.5 s.78
    • /
    • pp.581-591
    • /
    • 2005
  • This paper proposes a design formulae that evaluates the design strength of T-joints made of cold-formed square hollow steel sections with longitudinal branch plate. The T-joints had a configuration that a branch member used to longitudinal plate to the main chord in the plane. This study focused on the branch plate T-joints governed by the main chord flange failure mode among the experimental results. Based on the test results of the longitudinal branch plate T-joint in the square hollow sections, the ultimate strength on the T-joints was defined as 1.5 times the load at 1% B the strength of joints that governed the serviceability in control for $16.7{\leq}2\gamma(B/T){\leq}31.3$ and $0.20{\leq}{\beta}(b1/B){\leq}0.75$. Existing yield line models for normal T-joints were investigated to be the main chord flange failure for the branch plate T-joint, and this proposal design formula was based on the theory of the yield line model. Finally, the value of the finite element method compared with the value of the test and theory for the T-joints verified the validity of the design formulae.

Direct Control of Displacement Using Displacement and Resistance Force Contribution Factor (변위 및 내력기여도계수를 이용한 정량적 변위 제어)

  • Kim, Young-Min;Kim, Chee-Kyeong
    • Journal of Korean Association for Spatial Structures
    • /
    • v.5 no.3 s.17
    • /
    • pp.91-100
    • /
    • 2005
  • The paper presents a direct method for the diplacement control and stiffness redesign using displacement and response force contribution factors. At first, these two kinds of factors are derived and the relationship between them is examined. An equation to evaluate the change of displacement according to the change of each member stiffness is proposed. For the statically determinate structures, the proposed equation gives the exact solution with no approximation. But it has some error in case of statically indeterminate structures because the redistribution of response forces is neglected in the equation. However, the equation may be very useful even for statically indeterminate structures because it provides the relationship between the member stiffness and the global displacement. The proposed method is expected to be useful for the displacement control of large space or hi-rise building structures where the stiffness design governs the design result.

  • PDF

Ultimate Strength of Fillet-welded T-joints in Cold-formed Square Hollow Sections - Chord flange failure mode - (냉간성형 각형강관 모살용접 T형 접합부의 최대내력(I) - 주관 플랜지 파괴모드 -)

  • Bae, Kyu Woong;Park, Keum Sung;Kang, Chang Hoon;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.2
    • /
    • pp.311-318
    • /
    • 2002
  • This paper described the ultimate strength and deformation limit of welded T-joints in cold-formed square hollow sections. Previous studies showed that the strength of a T-joint still increases with increasing deformations at a ratio of branch width to chord width (${\beta}$) of below 0.8. Therefore, the strength at a certain deformation (chord flange indentation) limit can be regarded as the ultimate strength of a T-joint. The chord flange failure modes were investigated for the ratio of branch width to chord width (${\beta}$) and the ratio of chord width to chord web thickness (B/T). Experimental results including tests done by Kato proposed a deformation limit of 3%B for $16.7{\leq}B/T{\leq}41.6$ and $0.27{\leq}{\beta}{\leq}0.8$. The strength formula of CIDECT and other researchers were compared with the test results. Finally, the strength formula based on yield-line theory was proposed.