• Title/Summary/Keyword: 선 검출

Search Result 2,140, Processing Time 0.035 seconds

Manufacture of Daily Check Device and Efficiency Evaluation for Daily Q.A (일일 정도관리를 위한 Daily Check Device의 제작 및 효율성 평가)

  • Kim Chan-Yong;Jae Young-Wan;Park Heung-Deuk;Lee Jae-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.105-111
    • /
    • 2005
  • Purpose : Daily Q.A is the important step which must be preceded in a radiation treatment. Specially, radiation output measurement and laser alignment, SSD indicator related to a patient set-up recurrence must be confirmed for a reasonable radiation treatment. Daily Q.A proceeds correctness and a prompt way, and needs an objective measurement basis. Manufacture of the device which can facilitate confirmation of output measurement and appliances check at one time was requested. Materials and Methods : Produced the phantom formal daily check device which can confirm a lot of appliances check (output measurement and laser alignment. field size, SSD indicator) with one time of set up at a time, and measurement observed a linear accelerator (4 machine) for four months and evaluated efficiency. Results : We were able to confirm an laser alignment, field size, SSD indicator check at the same time, and out put measurement was possible with the same set up, so daily Q.A time was reduced, and we were able to confirm an objective basis about each item measurement. As a result of having measured for four months, output measurement within ${\pm}2%$, and measured laser alignment, field size, SSD indicator in range within ${\pm}1mm$. Conclusion : We can enforce output measurement and appliances check conveniently, and time was reduced and was able to raise efficiency of business. We were able to bring a cost reduction by substitution expensive commercialized equipment. Further It is necessary to makes a product as strong and slight materials, and improve convenience of use.

  • PDF

The effects of the mulberry and silkworm intake on androgen receptor mRNA and myogenic regulatory factors expression of rats muscle for resistance exercise (오디와 누에 섭취가 rats의 저항성 운동에 따른 androgen receptor mRNA와 myogenic regulatory factors의 발현에 미치는 영향)

  • Yang, Sung Jun;Kim, Chang Yong;Lee, Jo Byoung;Kang, Sung Sun;Lee, Jong Jin
    • Journal of Sericultural and Entomological Science
    • /
    • v.51 no.2
    • /
    • pp.99-106
    • /
    • 2013
  • The purpose of this study is to investigate the effects of supplementation of mulberry powder, mulberry extract and silkworm powder during the 8 weeks of resistance exercise on Androgen receptor(AR) mRNA and Myogenic regulatory factors(MRFs) expression of rats muscle. Fifty males, Sprague-Dawley rat, were randomly divided into 5 groups: CON(control group, n = 10), REG(resistance exercise group, n = 10), MP REG(mulberry powder intake and resistance exercise group, n = 10), ME REG(mulberry extract intake and resistance exercise group, n = 10) and SP REG(silkworm powder intake and resistance exercise group, n = 10). After climbing the ladder without weights during the 1 week of adaptation period, the rats in the resistance exercise group were trained to climb a 0.98-m vertical(80 degree incline) ladder with weights in their tail during 7 weeks(10 times each day, 2 days per week). After exercise, the skeletal muscle was extracted from the flexor hallucis longus. After separating the total ribonucleic acid (RNA) of each group, quantitative polymerase chain reaction was used to analyze RNA quantitatively. AR mRNA and MRFs expression revealed that all of the treated groups had significantly difference. AR mRNA expression increased in ME REG $6.24{\pm}1.85$ and SP REG $9.68{\pm}0.28$ fold compared to CON. Myod mRNA expression increased in MP REG $6.04{\pm}0.47$, ME REG $4.31{\pm}1.58$ and SP REG $8.11{\pm}0.57$ fold compared to CON. And myogenin mRNA expression increased in MP REG $4.11{\pm}0.42$, ME REG $4.12{\pm}0.45$ and SP REG $6.50{\pm}0.61$ fold compared to CON. In conclusion, during the resistance exercise, providing mulberry and silkworm gives positive effect on AR mRNA and MRFs expression increase.

Method for Validation of Caffeoylquinic Acid Derivatives in Ligularia fischeri Leaf Extract as Functional Ingredients (건강기능식품 기능성 원료로서 곰취잎 추출물의 Caffeoylquinic Acid계 성분 분석법 검증)

  • Kwon, Jin Gwan;Kim, Jin Kyu;Seo, Changon;Hong, Seong Su;Ahn, Eun-Kyung;Seo, Dong-Wan;Oh, Joa Sub
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.1
    • /
    • pp.61-67
    • /
    • 2016
  • An HPLC analysis method was developed for standard determinations of chlorogenic acid, 3,4-di-O-caffeoylquinic acid, 3,5-di-O-caffeoylquinic acid, and 4,5-di-O-caffeoylquinic acid as functional health materials in Ligularia fischeri extract. HPLC was performed on a $C_{18}$ Kromasil column ($4.6{\times}250mm$, $5{\mu}m$ column) with a gradient elution of 0.1% (v/v) trifluoroacetic acid and acetonitrile at a flow rate of 1.0 mL/min at $30^{\circ}C$. The analytes were detected at 330 nm. The HPLC method was validated in accordance with the International Conference on Harmonization guideline of analytical procedures with respect to specificity, precision, accuracy, and linearity. The limits of detection and quantitation for the four compounds were 3.0~14.6 and $9.2{\sim}44.4{\mu}g/mL$, respectively. Calibration curves showed good linearity ($r^2$ > 0.999), and the precision of analysis was satisfied (less than 0.9%). Recoveries of quantified compounds ranged from 98.96 to 101.81%. This result indicates that the established HPLC method is very useful for the determination of marker compounds in Ligularia fischeri leaf extracts.

Development of Video Image-Guided Setup (VIGS) System for Tomotherapy: Preliminary Study (단층치료용 비디오 영상기반 셋업 장치의 개발: 예비연구)

  • Kim, Jin Sung;Ju, Sang Gyu;Hong, Chae Seon;Jeong, Jaewon;Son, Kihong;Shin, Jung Suk;Shin, Eunheak;Ahn, Sung Hwan;Han, Youngyih;Choi, Doo Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.85-91
    • /
    • 2013
  • At present, megavoltage computed tomography (MVCT) is the only method used to correct the position of tomotherapy patients. MVCT produces extra radiation, in addition to the radiation used for treatment, and repositioning also takes up much of the total treatment time. To address these issues, we suggest the use of a video image-guided setup (VIGS) system for correcting the position of tomotherapy patients. We developed an in-house program to correct the exact position of patients using two orthogonal images obtained from two video cameras installed at $90^{\circ}$ and fastened inside the tomotherapy gantry. The system is programmed to make automatic registration possible with the use of edge detection of the user-defined region of interest (ROI). A head-and-neck patient is then simulated using a humanoid phantom. After taking the computed tomography (CT) image, tomotherapy planning is performed. To mimic a clinical treatment course, we used an immobilization device to position the phantom on the tomotherapy couch and, using MVCT, corrected its position to match the one captured when the treatment was planned. Video images of the corrected position were used as reference images for the VIGS system. First, the position was repeatedly corrected 10 times using MVCT, and based on the saved reference video image, the patient position was then corrected 10 times using the VIGS method. Thereafter, the results of the two correction methods were compared. The results demonstrated that patient positioning using a video-imaging method ($41.7{\pm}11.2$ seconds) significantly reduces the overall time of the MVCT method ($420{\pm}6$ seconds) (p<0.05). However, there was no meaningful difference in accuracy between the two methods (x=0.11 mm, y=0.27 mm, z=0.58 mm, p>0.05). Because VIGS provides a more accurate result and reduces the required time, compared with the MVCT method, it is expected to manage the overall tomotherapy treatment process more efficiently.

Analysis of Etiology and Prognosis of Pulmonary Complications in Children with Hematological or Oncological Disorders in Pediatric Intensive Care Unit (소아 중환자실에 입원한 혈액-종양 환아에서 발생한 폐 합병증의 원인과 예후에 대한 분석)

  • Jung, Jin Young;Hong, Soo-Jong;An, Young Jun;Kim, Ja Hyung;Seo, Jong Jin;Moon, Hyung Nam;Ghim, Thad
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.8
    • /
    • pp.1000-1006
    • /
    • 2002
  • Purpose : In the course of treatment, patients with hematological or oncological disorders often develop pulmonary complication. The patients who develop a severe pulmonary complication have a poor outlook. The causes of pulmonary complication are either infectious or non-infectious in origin. We have analyzed the etiology and outcome of these patients admitted to the pediatric intensive care unit of Asan Medical Center. Methods : Medical records of 95 patients on Pediatric oncology service who were admitted to pediatric intensive care unit(PICU) of Asan Medical Center from Jan 1997 to May 2000 were retrospectively reviewed. Results : The mean age of the patients was 8.5 years(2 months-18 years). The underlying malignancies of these 95 patients were as following; acute lymphoblastic leukemia(31 cases), lymphoma (11 cases), acute myeloid leukemia(nine cases), brain tumor(eight cases) and other solid tumors(25 cases). Pulmonary complications included pneumonia, acute respiratory failure, pneumothorax and pleural effusion. The most common cause of pulmonary complication was infection(88%) in etiology. The overall mortality rate was 56.8%. Pulmonary complications in these patients carried high rates of mortality regardless of whether they were immune compromised(76%) or not(69%). Even without pulmonary complications, the hematological or oncological patients admitted to PICU had high mortality rates of 43%. Conclusion : Pulmonary complications are frequent finding in the hematological or oncological patients admitted to Intensive Care Unit. The main etiology of these pulmonary complications was infection, which carried a high mortality rate regardless of their immune status at the time when they were admitted to PICU.

Occurrence of Plant Parasitic Nematodes in Chrysanthemum and ITS and D3-28S rDNA Characterization of Pratylenchus spp. (국화재배지의 식물기생선충 분포조사 및 뿌리썩이선층의 ITS와 D3-28S rDNA 특성조사)

  • Han, Hye-Rim;Lee, Jae-Kook;Choi, Dong-Ro;Han, Man-Jong;Park, Byeong-Yong
    • Korean journal of applied entomology
    • /
    • v.45 no.3 s.144
    • /
    • pp.293-299
    • /
    • 2006
  • A survey was conducted to find out the major plant parasitic nematode in Chrysanthemum morifolium fields in Korea from May to June in 2005. A genus of Pratylenchus was determined as the most important plant parasitic nematode based on analysis of total 50 samples from 8 cities of chrysanthemum field. Pratylenchus showed 86% occurrence rate and average numbered 1,095 per 200cc soils and 1g root. Five Pratylenchus isolates, 'Muan', 'Masan', 'Tean', 'Gumi', 'Jeongup', were selected for the molecular identification of the species of Pratylenchus, and ITS and D3-28S ribosomal DNA were amplified by PCR. For the ITS, only 'Muan' isolate was differentiated by total 1 kb PCR amplification, which was 200 bp larger than all the other isolates. There was no size variation in amplified D3-28S rDNA and all isolate represented approximately 320 bp of PCR product. Sequence data of D3-28S rDNA were analysed by MegAlign program in DNASTAR software and phylogenetic tree was constructed. Sequence homology was 100% between 'Gumi' isolate and 'Tean' isolate and 'Jeongup' isolate was also close to these isolates by 99.7% sequence homology. 'Gumi', 'Tean' group and 'Jeongup' isolate were determined to be closely related to Pratylenchus vulnus by 96.7% and 96.3% similarity in respectively. D3 sequence of 'Masan' isolate was 100% identical to P. penetrans, and 'Muan' isolate showed 99.7% similarity to P. brachyurus. This result was congruent with the branch divergence pattern shown in phylogenetic tree.

Effects of Gamma Irradiation and Ethylene Oxide Fumigation for the Quality Preservation of Spices and Dry Vegetables (건조향신 조미식품의 품질보존을 위한 효과적인 살균방법에 관한 비교연구)

  • 신광순;마점술;조종후
    • Journal of Food Hygiene and Safety
    • /
    • v.4 no.2
    • /
    • pp.119-132
    • /
    • 1989
  • Gamma irradiation as a new physical treatment was applied to comparative investigates with a conventional ethylene oxide fumigant on the microbiological and physicochemical qualities of selected spices and dry vegetables such as powdered red pepper, black pepper, welsh onion, onion, garlic, carrot, korean cabbage and instant ramyon soup. The microorganisms contaminated in the sample, including total viable count, thermophilic bacteria, aerobic spore and fungi counts between the $10^4\;to\;10^6/g$ range. Coliforms were found only in black pepper and welsh onion powder as the $10^2\;to\;10^3/g$ level. A radiation dose of 7 to 10 KGy were sterilized completely to the contaminated microorganisms, while ehthylene oxide (E.O.) fumigation reduced of them to the $10^3/g$ level. An optimum dose of irradiation was less detrimental than E.O. fumigation to the physicochemical properties of the sample. Sensory evaluation after three months of storage at room temperatures showed that the overall acceptability of irradiated sample was higher than that of the non treated control as well as E.O. fumigated samples. Comparison gamma irradiation with E.O. gas treatment showed that E.O. treatment was less effective than radiation in cotrolling microbial contamination of spices and vegetables.

  • PDF

A Study of Changes of Inversion Time Effect on Brain Volume of Normal Volunteers (반전 시간의 변화가 정상인의 뇌 체적에 미치는 영향에 대한 고찰)

  • Kim, Ju Ho;Kim, Seong-Hu;Shin, Hwa Seon;Kim, Ji-Eun;Na, Jae Boem;Park, Kisoo;Choi, Dae Seob
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.286-293
    • /
    • 2013
  • Purpose : The objective of this study was to analyze the brain volume according to the brain image of healthy adults in the 20s taken with different inversion time (TI). Materials and Methods: Brain images of healthy adults in the 20 s were acquired using magnetization prepared rapid acquisition gradient echo (MPRAGE) pulse sequence with 1.5 mm thickness of pieces and four inversion times (1100 ms, 1000 ms, 900 ms, 800 ms). The acquired brain images were analyzed to measure the volume of white matter (WM), gray matter (GM), intracranial volume (ICV). The statistical difference according to brain volume and gender was analyzed for each TI. Results: The brain volume calculated using Freesurfer was WM$486.52{\pm}48.64cm^3$ and GM=$646.83{\pm}57.12cm^3$ in mean when adjusted by mean ICV=$1278.94{\pm}154.92cm^3$. Men's brain volume(WM, GM, ICV) was larger than women's brain volume. In the intrarater reliability test, all of the intraclass correlation coefficients were high (0.992 for WM, 0.988 for GM, and 0.997 for ICV). In the repeated measures analysis of variance, GM and ICV did not show a significant difference at each TI (GM p=0.143, ICV p=0.052), but WM showed a significant (p=0.001). In the linear structure relation analysis, all of the Pearson correlation coefficients were high. Conclusion: WM, GM, and ICV indicated high reliability and solid linear structure relations, but WM showed significant differences at each TI. The brain volume of healthy adults in the 20s could be used in comparison with that of patients for reference purposes and to predict the structural change of brain. It would be needed to conduct additional studies to examine the contract, SNR, and lesion detection ability according to variable TI.

Development and Validation of Analytical Method for Pectolinarin and Pectolinarigenin in Fermented Cirsium setidens Nakai by Bioconversion (생물전환에 의한 발효 고려엉겅퀴 Pectolinarin 및 Pectolinarigenin의 분석법 개발 및 검증)

  • Oh, Ji-Won;Lee, Jin-Ha;Cho, Myoung-Lae;Shin, Gi-Hae;Kim, Jae-Min;Choi, Sun-Il;Jung, Tae-Dong;Kim, Young-Hyun;Lee, Sang-Jong;Lee, Bong Jin;Park, Seon Ju;Lee, Ok-Hwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.10
    • /
    • pp.1504-1509
    • /
    • 2015
  • The aim of this study was to investigate a validation method for determination of pectolinarin and pectolinarigenin in fermented Cirsium setidens Nakai. For validation, the specificity, linearity, precision, accuracy, detection limits, and quantification limits of pectolinarin and pectolinarigenin were measured by HPLC. The results show that the detection limits of pectolinarin and pectolinarigenin were $4.25{\mu}g/mL$ and $2.46{\mu}g/mL$, respectively. The recovery rates of pectolinarin and pectolinarigenin were high in the ranges of 99.7~104.0% and 99.7~102.4%, respectively. Inter-day and intra-day precisions of pectolinarin and pectolinarigenin in fermented Cirsium setidens Nakai were 0.9%, 0.5% and 0.5%, 0.2%, respectively. Therefore, application of pectolinarin and pectolinarigenin was validated by an analytical method as a marker compound in Cirsium setidens Nakai.

Operator Exposure to Indoxacarb Wettable Powder and Water Dispersible Granule during Mixing/loading and Risk Assessment (Indoxacarb의 수화제 및 입상수화제 살포액 조제 시 농작업자의 노출량 측정 및 위해성 평가)

  • Kim, Eunhye;Hwang, Yon-Jin;Kim, Suhee;Lee, Hyeri;Hong, Soonsung;Park, Kyung-Hun;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.4
    • /
    • pp.343-349
    • /
    • 2012
  • Exposure and risk assessments were conducted to evaluate the relative safety of mixing/loading work of indoxacarb between wettable powder (WP) and water dispersible granule (WG). Hand exposure was monitored using cotton gloves while inhalation exposure was measured using personal air monitor. Method validation for the exposure monitoring was established successfully through several experiments. Limit of determination and limit of quantitation were 0.25 and 1 ng, respectively. $R^2$ of calibration curve linearity was more than 0.9999 and reproducibility was 0.7-6. Recovery of indoxacarb from gloves, solid sorbent and glass fiber filter at three different levels was 81.5-108.8%. Trapping efficiency and breakthrough tests gave 981.5-108.8% of recovery. During mixing/loading procedure, hand exposure amount (75 percentile of 30 repetitions) for indoxacarb WP was 6 folds (459.8 mg/kg a.i) than that of WG (81.4 mg/kg a.i). This result indicates that WG has less drift than WP thanks to its granular type of formulation. Inhalation amount was $10^{-8}-10^{-7}%$ of spray mixture prepared and $10^{-4}-10^{-3}%$ of hand exposure. In inhalation case, no significant differences were observed between two formulations. Margin of safety was calculated for risk assessment using male Korean average body weight and acceptable operator exposure level as the important exposure factors. Mixing/loading procedures for both of the formulations were considered to be of least risk because calculated MOS values were more than 1.