• Title/Summary/Keyword: 선회류

Search Result 106, Processing Time 0.021 seconds

Visualization of Internal Flows in the Wall-injected Test Model of a SRM (고체로켓모터 표면분사 시험모델의 유동 가시화)

  • Kim, Do-Hun;Lee, In-Chul;Koo, Ja-Ye;Cho, Yong-Ho;Kang, Moon-Jung;Kim, Yoon-Gon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.3
    • /
    • pp.31-39
    • /
    • 2011
  • The flowfield in a solid rocket motor was simulated at the wall-injection test model, which has a fin-slot grain and submerged nozzle, and visualized by a smoke-wire. The high speed CCD camera captured the visualized images around the nozzle inlet through the grain center port. The vortical tube structure and circumferential flow patterns at the nozzle throat were visualized. The radial momentum transfer caused by the shear-interactions of slot-outlet flow, fin-base flow and grain port flow from upstream worked as the source of these phenomena.

Development of Vortex Scrubber Using Electrolyzed Water for the Removal Efficiency Improvement of Minute Particles and Odor (미세분진 및 냄새제거 효율향상을 위한 선회류식 세정전해 기술개발)

  • Kim, Nor-Jung;Lim, Seong-Il;Kim, Sun-Mi;Kim, Sun-Uk;Kim, Lae-Hyun;Kim, Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.3
    • /
    • pp.1-7
    • /
    • 2010
  • According to Indoor Air Quality(IAQ) management law for multi-use buildings, SEEONE CO., Ltd. made pilot and tested it to remove minute particle, odor, VOCs, etc. within the standards of IAQ. This pilot made by SEEONE CO., Ltd. is vortex scrubber washing electrolyzed water. As 30 minutes test result in multi-use building indoor place, minute particle(the smoke of a cigarette) was reduced $920{\mu}g/m^3{\rightarrow}112{\mu}g/m^3$, gaseous contaminants was reduced Formaldehyde (HCHO) 20ppm$\rightarrow$4ppm, Ammonia($NH_3$) 50ppm$\rightarrow$1ppm, Trimethylamine ($(CH_3CH_2)_3N$) 15ppm$\rightarrow$trace, Methylethylketone($CH_3COC_2H_5$) 25ppm$\rightarrow$trace, Acetic acid ($CH_3COOH$) 20ppm$\rightarrow$trace, Acetaldehyde($CH_3CHO$) 15ppm$\rightarrow$2ppm and Acetone($CH_3COCH_3$) 50ppm$\rightarrow$N.D. The pilot test result of the air filter using electroyzed water in vortex scrubber showed high removal efficiency. Because purified air maintain indoor humidity of approximately 40~60%, so users can feel pleasant. In E.coli, S.aureus sterilization test and CODcr, turbidity treatment test by electrolysis, germs was sterilized over 99.99% and CODcr and turbidity was decreased gradually. So water used for washing can be reused by electrolysis.

Influence of Porosity on Dielectric Constant of Codierite Ceramic (코오디어라이트 세라믹의 유전상수에 미치는 기공율의 영향)

  • Ryu, Su-Chak;Park, Hui-Chan
    • Korean Journal of Materials Research
    • /
    • v.6 no.2
    • /
    • pp.182-187
    • /
    • 1996
  • 물과 에탄올의 혼합용액에 HCI을 촉매로하여 금속알콕사이드의 가수분해로부터 코오디어라이트 분말을 제조하였다. 이때 HCI/precursor 몰비로써 촉매의 양을 조절하였다. 건조분말 중의 용매를 제거하기위해 80$0^{\circ}C$에서 3시간 하소처리하였다. 이들 하소된 분말에 대하여 시차열분석과 X-선회절분석을 행한 결과-92$0^{\circ}C$에서 $\mu$-cordierite, -103$0^{\circ}C$에서 $\alpha$-cordierite 결정상의 생성을 확인하였다. 또한, 하소분말을 가압성형한 후 130$0^{\circ}C$에서 4시간 열처리한 결과 HCI양에 따라 기공율 19.45-25.45%, 부피비중 2.06-1.70g/㎤, 유전상수 1.38-3.38 범위의 소결체를 얻었다. HCI양이 증가할수록 기공율은 증가한 반면에 비유전상수와 부피비중은 감소하였다.

  • PDF

Computational Analysis of Airflow in Upper Airway for Drug Delivery of Asthma Inhaler (천식 흡입기의 약물전달을 위한 상기도내의 유동해석)

  • Lee, Gyun-Bum;Kim, Sung-Kyun
    • Transactions of the KSME C: Technology and Education
    • /
    • v.2 no.2
    • /
    • pp.73-80
    • /
    • 2014
  • Drug delivery in human upper airway was studied by the numerical simulation of oral airflow. We created an anatomically accurate upper airway model from CT scan data by using a medical image processing software (Mimics). The upper airway was composed of oral cavity, pharynx, larynx, trachea, and second generations of branches. Thin sliced CT data and meticulous refinement of model surface under the ENT doctor's advice provided more sophisticated nasal cavity models. With this 3D upper airway models, numerical simulation was conducted by ANSYS/FLUENT. The steady inspiratory airflows in that model was solved numerically for the case of flow rate of 250 mL/s with drug-laden spray(Q= 20, 40, 60 mL/s). Optimal parameters for mechanical drug aerosol targeting of predetermined areas was to be computed, for a given representative upper airways. From numerical flow visualization results, as flow-rate of drug-laden spray increases, the drag spray residue in oral cavity was increased and the distribution of drug spray in trachea and branches became more homogeneous.

Numerical Analysis of Flow Distribution Inside a Fuel Assembly with Split-Type Mixing Vanes (분할 형태 혼합날개가 장착된 연료집합체 내부유동 분포 수치해석)

  • Lee, Gong Hee;Cheong, Ae Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.5
    • /
    • pp.329-337
    • /
    • 2016
  • As a turbulence-enhancing device, a mixing vane, which is installed at a spacer grid of the fuel assembly, plays an important role in improving convective heat transfer by generating either swirl flow in the subchannels or cross flow between the fuel rod gaps. Therefore, both the geometric configuration and the arrangement pattern of a mixing vane are important factors in determining the performance of a mixing vane. In this study, in order to examine the flow-distribution features inside a $5{\times}5$ fuel assembly with split-type mixing vanes, which was used in the benchmark calculation of the OECD/NEA, we conduct simulations using the commercial computational fluid dynamics software, ANSYS CFX R.14. We compare the predicted results with measured data obtained from the MATiS-H (Measurement and Analysis of Turbulent Mixing in Subchannels-Horizontal) test facility. In addition, we discuss the effect of the split-type mixing vanes on the flow pattern inside the fuel assembly.

Numerical Study on Heat Transfer Characteristics of Turbulent Flow in Transition Duct (안내덕트 내부 난류유동구조에 따른 열전달 특성변화 수치해석)

  • Yoo, Geun-Jong;Choi, Hoon-Ki;Choi, Kee-Lim
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.923-932
    • /
    • 2011
  • Because of the instability of a flow pattern in the inlet transition square duct (hereinafter referred to as "transition duct") of a heat recovery steam generator (hereinafter referred to as "HRSG") in a combined cycle power plant, the Reynolds number in the first row of a tube bank is differs sharply from that in the sectional area of the transition duct. This causes differences in the heat flux in each tube in the tube bank. The computational fluid dynamics (CFD) predictions provide three-dimensional results for velocity, temperature, and other flow parameters over the entire domain of the duct and HRSG. A renormalization group theory (RNG) based k-${\epsilon}$�� turbulent model is used for obtaining the results cited in this study. A porous media option is used for modeling the tube banks and the number of transfer units method is used for determining the heat transfer characteristics. This study describes a comparison between the numerical simulation results and actual design output.

Numerical simulation of VOC decomposition in an arc plasma reactor (수치해석 기법을 이용한 아크 플라즈마 반응기의 VOCs 분해성능 평가연구)

  • Park, Mi-jeong;Jo, Young-min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.1-7
    • /
    • 2016
  • A range of techniques have been being developed to remove the volatile organic compounds from paining processes. High temperature decomposition of harmful VOCs using arc plasma has recently been proposed, and this work analyzed the extreme hot process by computer-aided fluid dynamics prior to the reactor design. Numerical simulations utilized the conservation equations of mass and momentum. The simulation showed that the fluid flowed down along the inner surface of the centrifugal reactor by forming intensive spiral trajectories. Although the high temperature gas generated by plasma influences the bottom of the reactor, no heat transfer in radial direction appeared. The decomposition efficiency of a typical VOCs, toluene, was found to be a maximum of 67% across the reactor, which was similar to the value (approximately 70%) for the lab-scale test.

Theoretical Analysis and Experimental Evaluation of Small Cyclone Separator to Remove Fine Particulate Matter (미립 물질 제거를 위한 소형 사이클론 분리기의 이론적 연구 및 실험적 검증)

  • Ko, Han Gyul;Kim, Hong Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.1
    • /
    • pp.77-82
    • /
    • 2013
  • A cyclone separator has been widely used in various industrial processes for removing fine particulate matter because it is easy to fabricate, cost effective, and adaptable to extremely harsh conditions. However, owing to the complex flow field in cyclones, a complete understanding of the detailed mechanisms of particulate removal has not yet been gained. In this study, a theoretical analysis was performed for calculating the collection efficiency and cut-off size in cyclones by taking into account the effects of geometrical and flow parameters. The collection efficiency and cut-off size values predicted by the theoretical model showed good agreement with experimental measurements for particles with a diameter of $0.5-30{\mu}m$. It was also revealed that the surface friction, along with the flow and geometrical parameters, has a significant effect on the cyclone performance.

Study on Effect of Micro Tooth Shape Modification on Power Transmission Characteristics based on the Driving Gear of Rotating Machining Unit (마이크로 치형수정이 선회가공 유닛 구동기어의 동력전달 특성에 미치는 영향에 관한 연구)

  • Jang, Jeong-Hwan;Qin, Zhen;Kim, Dong-Seon;Wu, Yu-Ting;Lyu, Sung Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.6
    • /
    • pp.91-97
    • /
    • 2019
  • Rotating machining unit is a revolutionary product that can process worm shaft or spiral shaft with fast and precise, a rotary type cutting tool, which is attached to automatic lathe and processes spiral groove on outer circumference of round bar. In this work, a study on micro tooth shape modification method of driving gear train in the rotating machining unit was presented. To observe the effect on power transmission characteristics of the driving gear pair, visualize the gear meshing condition and the load distribution on the gear teeth by using the professional gear train analysis program RomaxDesigner. By comparing the repeated analysis results, the effect of micro tooth shape modification on power transmission characteristics on driving gear can be summarized. The optimized gears were fabricated and measured by precision tester as a validation in this research.

Oxygen Transfer and Hydraulic Characteristics in Bubble Column Bioreactor Applied Fine Bubble Air Diffusing System (미세기포 산기장치를 적용한 타워형 생물반응기의 산소전달 및 수력학적 특성)

  • Lee, Seung-Jin;Ko, Kyeong-Han;Ko, Myeong-Han;Yang, Jae-Kyeong;Kim, Yong-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.11
    • /
    • pp.772-779
    • /
    • 2012
  • For improving performance of conical air diffuser generating fine bubble, both experimental and numerical simulation method were used. After adapting diffusers inner real scale bubble column, suitable for various diffuser submergence, the effect of diffuser submergence on oxygen transfer performance such as Oxygen Transfer Coefficient ($K_{L}a_{20}$) and Standard Oxygen Transfer Efficiency (SOTE) was investigated empirically. As flow patterns for various diffuser number and submergence were revealed throughout hydrodynamic simulation for 2-phase fluid flow of air-water, the cause of the change for oxygen transfer performance was cleared up. As results of experimental performance, $K_{L}a_{20}$ was increased slightly by 7% and SOTE was increased drastically by 39~72%, 5.6% per meter. As results of numerical analysis, air volume fraction, air and water velocity in bioreactor were increased with analogous flow tendency by increasing diffuser number. As diffuser submergence increased, air volume fraction, air and water velocity were decreased slightly. Because circulative co-flow is determinant factor for bubble diffusion and rising velocity, excessive circulation intensity can result to worsen oxygen transfer by shortening bubble retention time and amount.