A Review on IPP/Elastomer/Nanofiller Composites for the Possibility of Use as Power Cable Insulations (동일배열 폴리프로필렌/엘라스토머/나노충전제 복합체의 전력케이블 절연체로서의 사용 가능성에 대한 문헌적 고찰)

  • Pyun, Sun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.184-192
    • /
    • 2012
  • For use as recyclable power cable insulations without dielectric oil, technology trends of IPP based thermoplastic polyolefin elastomer(TPO) nanocomposites were reviewed. In 2010 research results of IPP nanocomposite dielectrics for power capacitors showed promising high voltage properties except dielectric loss. Research of IPP based TPO nanocomposites for automotive exterior parts revealed considerable improvements of mechanical properties including impact strength, especially minimization of compatibilizer content, the origin of dielectric loss. A study on electrical properties of IPP based TPO nanocomposites containing a few weight percent of nanofillers for power cable insulations is suggested.

Empirical Model of Via-Hole Structures in High-Count Multi-Layered Printed Circuit Board (HCML 배선기판에서 비아홀 구조에 대한 경험적 모델)

  • Kim, Young-Woo;Lim, Yeong-Seog
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.12
    • /
    • pp.55-67
    • /
    • 2010
  • The electrical properties of a back drilled via-hole (BDH) without the open-stub and the plated through via-hole (PTH) with the open-stub, which is called the conventional structure, in a high-count multi~layered (HCML) printed circuit board (PCB) were investigated for a high-speed digital system, and a selected inner layer to transmit a high-speed signal was farthest away from the side to mount the component. Within 10 GHz of the broadband frequency, a design of experiment (DOE) methodology was carried out with three cause factors of each via-hole structure, which were the distance between the via-holes, the dimensions of drilling pad and the anti-pad in the ground plane, and then the relation between cause and result factors which were the maximum return loss, the half-power frequency, and the minimum insertion loss was analyzed. Subsequently, the empirical formulae resulting in a macro model were extracted and compared with the experiment results. Even, out of the cause range, the calculated results obtained from the macro model can be also matched with the measured results within 5 % of the error.

8-port Coupled Transmission Line Modeling of KSATR ICRF Antenna and Comparison with Measurement (커플링이 고려된 KSTAR ICRF 안테나의 8포트 전송선 회로 모델링 및 측정 결과 비교)

  • Kim, S.H.;Wang, S.J.;Hwang, C.K.;Kwak, J.G.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.1
    • /
    • pp.72-80
    • /
    • 2010
  • It is very important to predict and analyze the change of voltage and current distribution of current strap, abnormal voltage distribution of transmission line and resonance phenomenon by coupling between current straps for more stable operation of ICRF system. In this study, to understand those phenomena by coupling, 8-port coupled transmission line model is completed by appling S-parameter measured in the prototype KSTAR ICRF antenna to the model. The determined self-inductance, mutual-inductance and capacitance of antenna straps are shown to be lower than that calculated from 2D approximate model due to finite length of strap. The coupled transmission line model of current strap will be utilized to the operation of ICRF system of KSTAR in the future.

Effect of Electrical and CO2 Stunning Methods on Incidence of PSE Pork (전기 및 CO2 실신에 따른 돈육의 PSE 발생률 비교)

  • Park, Beom-Yeong;Kim, J.H.;Lee, S.H.;Cho, S.H.;Hwang, I.H.;Kim, K.T.;Kim, D.H.;Kim, Y.K.;Lee, J.M.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.2
    • /
    • pp.271-276
    • /
    • 2005
  • The objective of this study was to investigate the incidence of PSE pork depending on different stunning conditions at slaughterhouse. The carcass weights were significantly lower in the normal pork(74.6 kg) than those in the severe PSE pork(76.9 kg) and light PSE pork(77.0 kg). The groups of PSE pork showing the light or the severe PSE sign had significantly lower backfat thickness and intramuscular fat contents when compared to the normal pork(p < 0.05). The incidences of PSE pork significantly increased with the increase of the electrical stunning voltages such that they were 12.3% with 220V of stunning voltage, 17.41% with 240 V of stunning voltage, 24.91 % with 250 V of stunning voltage and 43.12 % with 430 V of stunning voltage. On the other hand, the incidence of PSE pork was significantly lower in $CO_2$ stunning(33 %) than high-voltage stunning(500 V, 72.96 %) when they were slaughtered with the same slaughtering condition except the stunning method. The $CO_2$ stunning method was very effective to reduce the incidence of PSE pork. Therefore, the result from this study suggested that the stunning methods had a significant effect on the incidence of PSE pork. Also, the low-voltage stunning and $CO_2$ stunning methods were highly recommended to control and maintain the pork quality.

Characteristics of Catalyst and Influence of Promoter for Hydrogen Electrode in Alkaline Fuel Cell (알칼리형 연료전지용 수소극의 촉매 특성과 조촉매의 영향)

  • Yun, Sun Ho;Lee, Hong Ki;Lee, Ju Seong
    • Applied Chemistry for Engineering
    • /
    • v.4 no.2
    • /
    • pp.373-380
    • /
    • 1993
  • The preparation method of Raney nickel catalyst and the effect of promotor for the hydrogen electrode in alkaline fuel cell were investigated with electrochemical methods. The best electrode performance was observed with the Raney nickel which was obtained at $700^{\circ}C$ of sintering temperature and 60:40 of nickel:aluminum. As titanium was added for promotor, the activity of catalyst and characteristic of electrode was improved. Especially, the electrode containing 2w/o of titanium showed the maximum mass activity of 2.4A/g and its mean particle size was $5.7{\mu}m$. The resistance and capacitance of the electrode containing 2w/o of titanium, measured with AC impedance spectroscopy, were calculated to the $0.3{\Omega}cm^2$ and $0.42F/cm^2$, respectively.

  • PDF

Optimized Design of Air Controlling System in Air Defense Gun Systems of Wheeled Vehicle (차륜형 대공포의 냉방기 최적화 설계)

  • Jeon, Ki-Hyun;Lee, Boo-Hwan;Lee, Dong-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1047-1051
    • /
    • 2013
  • A modern combat vehicle needs to have a separate air-conditioning unit, although new combat systems tend to employ an integrated heating, cooling, and ventilating system. In this study, we investigated an air conditioning unit for an armored combat wheeled vehicle as a special use and military specification and performed a case study of a unique military combat vehicle. By using Fluent software, we tried to determine a suitable air ducting method and its location in the armored combat vehicle. The results show that an air-conditioning unit is one of the best solutions for wheeled vehicles that are not equipped with a cooling unit for their crews, and it can be applied to similar types of armored vehicles.

Reconstruction of Myocardial Current Distribution Using Magnetocardiogram and its Clinical Use (심자도를 이용한 심근 전류분포 복원과 임상적 응용)

  • 권혁찬;정용석;이용호;김진목;김기웅;김기영;박기락;배장호
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.459-464
    • /
    • 2003
  • The source current distribution in a heart was reconstructed from the magnetocardiogram (MCG) and its clinical usefulness was demonstrated. MCG was measured using 40-channel superconducting quantum interference device (SQUID) gradiometers for a patient of Wolff-Parkinson-White (WPW) syndrome, which has an accessory pathway between the atria and the ventricles. Reconstruction of source current distribution in a plane below the chest surface was performed using minimum norm estimation (MNE) algorithm and truncated singular value decomposition (SVD), In the simulation, we confirmed that the current distributions. which were computed for the test dipoles, represented well the essential feature of the test current configurations, In the current map of WPW syndrome, we observed abnormal currents that would bypass the atrioventricular junction at a delta wave. However, we could not observe such currents any more after the surgery. These results showed that the obtained current distribution using MCG signals is consistent with the electrical activity in a heart and has clinical usefulness.

Analysis of Purchasing Behaviors for Korean Elderly Consumers (한국 노년 소비자의 구매행동에 관한 분석)

  • Seo, Bong-Chul;Kim, Sook-Eung
    • Journal of Distribution Research
    • /
    • v.10 no.4
    • /
    • pp.23-39
    • /
    • 2005
  • Recently, aging population will be coming out of the first magnitude demanders in this age. The purpose of the study is to present the basic data useful to get the public attention concerning the development of the consumer market of the elderly people by looking into the various factors which may influence the consumer. The results of the study will be very useful in establishing the relevant marketing strategies and in. providing the business opportunities for the elderly consumers in Korea. A survey was performed on actual Korean consumers aged over 55 and the results was compared with data previously reported in Korea and U.S.A.

  • PDF

Fabrication and Applications of Polyphenylene Sulfide (PPS) Composites: A Short Review (폴리페닐렌설파이드(PPS) 복합소재 제조 및 응용)

  • Choi, Minsik;Lee, Jungrok;Ryu, Seongwoo;Ku, Bon-Cheol
    • Composites Research
    • /
    • v.33 no.3
    • /
    • pp.91-100
    • /
    • 2020
  • Polyphenylene sulfide (PPS) is a semi-crystalline engineering thermoplastic resin that has outstanding thermal stability, mechanical strength, inherent flame retardancy, chemical resistance, and electrical properties. Due to these outstanding properties, it is preferred as a matrix for composite materials. Many studies have been conducted to produce composites with carbon fibers and glass fibers to improve mechanical properties and provide functionality of PPS. In this review paper, we report a brief introduction to the fabrication and applications of PPS composites with carbon nanotubes, graphene, carbon fibers, and glass fibers.

Public Preferences for Replacing Hydro-Electricity Generation with Coal-Fired Power Generation (석탄화력 발전 대비 수력 발전에 대한 국민 선호도 분석)

  • Choi, Hyo-Yeon;Ryu, Mun-Hyun;Yoo, Seung-Hoon
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.164-171
    • /
    • 2015
  • Although coal-fired power generation has played a role as base load unit, it has incurred various social costs in the process of generating and providing electricity. It is necessary to extend the proportion of low-carbon power generations, and reduce the ratio of coal-fired power generation to cope with global climate changes. This study, therefore, attempts to estimate the public's willingness-to-pay (WTP) for substitution of supplied electricity from hydro-electricity generation, a representative renewable energy, for coal-fired power generation. To this end, we apply the contingent valuation (CV) method, widely used technique when valuing non-market goods, to elicit the public's WTP. In addition, a spike model is employed to consider zero WTPs. After the empirical analysis with 1,000 households CV survey data, the results show that mean household's WTP for replacing supplied electricity from hydro-electricity generation with coal-fired power generation is estimated to be about 54 KRW per kWh. The results of this study are expected to contribute to determining energy-mix and provide benefit information of hydro-electricity generation.