• Title/Summary/Keyword: 선형 안정성

Search Result 1,190, Processing Time 0.026 seconds

Stereotactic Target Point Verification in Actual Treatment Position of Radiosurgery (방사선수술시 두개내 표적의 정위적좌표의 치료위치에서의 확인)

  • Yun, Hyong-Geun;Lee, Hyun-Koo
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.403-409
    • /
    • 1995
  • Purpose : Authors tried to enhance the safety and accuracy of radiosurgery by verifying stereotacitc target point in actual treatment position prior to irradiation. Materials and Methods : Before the actual treatment, several sections of anthropomorphic head phantom were used to create a condition of unknown coordinates of the target point. A film was sandwitched between the phantom sections and punctured by sharp needle tip. The tip of the needle represented the target point. The head phantom was fixed to the stereotactic ring and CT scan was done with CT localizer attached to the ring. After the CT scanning, the stereotactic coordinates of the target point were determined. The head phantom was secured to accelerator's treatment couch and the movement of laser isocenter to the stereotactic coordinates determined by CT scanning was performed using target positioner. Accelerator's anteroposterior and lateral portal films were taken using angiographic localizers. The stereotactic coordinates determined by analysis of portal films were compared with the stereotactic coordinates previously determined by CT scanning. Following the correction of discrepancy the head phantom was irradiated using a stereotactic technique of several arcs. After the irradiation, the film which was sandwitched between the phantom sections was developed and the degree of coincidence between the center of the radiation distribution with the target point represented by the hole in the film was measured. In the treatment of the actual patients, the way of determining the stereotactic coordinates with CT localizers and angiograuhic localizers was the same as the phantom study. After the correction of the discrepancy between two sets of coordinates, we proceeded to the irradiation of the actual patient. Results : In the phantom study, the agreement between the center of the radiation distribution and the localized target point was very good. By measuring optical density profiles of the sandwitched film along axes that intersected the target point, authors could confirm the discrepancy was 0.3 mm. In the treatment of an actual patient, the discrepancy between the stereotactic coordinates with CT localizers and angiographic localizers was 0.6 mm. Conclusion : By verifying stereotactic target point in actual treatment position prior to irradiation, the accuracy and safety of streotactic radiosurgery procedure were established.

  • PDF

A Study on the Extraction Rate of Brain Tissues from a $^{99m}Tc$-HMPAO Cerebral Blood flow SPECT Examination of a Patient ($^{99m}Tc$-HMPAO 뇌혈류 SPECT 검사 시 환자에 따른 뇌조직 추출률에 대한 고찰)

  • Kim, Hwa-San;Lee, Dong-Ho;Ahn, Byeong-Pil;Kim, Hyun-Ki;Jung, Jin-Yung;Lee, Hyung-Nam;Kim, Jung-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2012
  • Purpose: This study mainly focuses on the patients treated with chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO (d,l-hexamethylpropylene amine oxime) which yielded reduced image quality due to a decreased brain extraction rate. $^{99m}Tc$-HMPAO will be examined further to determine whether this product may be accounted as a factor for this cause. Material and Methods: From January 2010 until December 2010, out of 272 patients who were all subjected to $^{99m}Tc$-HMPAO brain blood flow SPECT scans resulting from Cerebral Infarction; 23 patients(ages $55.3{\pm}9$, 21 males, 3 females) with decreased tissue extraction rate were examined in detail. The radiopharmaceutical product $^{99m}Tc$-HMPAO was used on patients with normal brain tissue exchange rate as well as those with reduced rate in order to prove its' chemical stability. The patients' age, sex, blood pressure, existence of diabetes, drug use, current health status, known side effects from CT/MRI, examination of the patients' past SPECT before/after images were accounted to determine the factors and correlations affecting the rate of blood tissue extractions. Result: After multiple linear regression analysis, there were no unusual correlations between the 6 factors excluding sex, and before/after examination images. Male subjects showed reduced brain tissue extraction rate than the females ($p$ > 0.05) 91.3% male, 8.7% female. Wilcoxon Matched-Pairs Signed-Ranks Test was used on the before/after images which yielded a value of 0.06, which did not indicate a significant amount of difference on the 2 tests ($p$ > 0.05). As a result, the before/after images indicated similar brain tissue extraction rates, and there were variations depending on the individual patient. Conclusion: The effects of the chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO depended on the patient's personal characteristics and status, therefore was considered to be a factor in reducing brain tissue extraction rate. The related articles of $^{99m}Tc$-HMPAO cerebral blood flow SPECT speculates a cerebrovascular disease and factors resulting from portal veins, and it was not possible to pin point the exact cause of decreasing brain tissue extraction rate. However, the $^{99m}Tc$-HMPAO cerebral blood flow SPECT scan proved to be extremely useful in tracking and inspecting brain diseases, as well as offering accurate results from patients suffering from reduced brain tissue extraction rates.

  • PDF

KOREAN MARS MISSION DESIGN USING KSLV-III (KSLV-III를 이용한 한국형 화성 탐사 임무의 설계)

  • Song, Young-Joo;Yoo, Sung-Moon;Park, Eun-Seo;Park, Sang-Young;Choi, Kyu-Hong;Yoon, Jae-Cheol;Yim, Jo-Ryeong;Choi, Joon-Min;Kim, Byung-Kyo
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.4
    • /
    • pp.355-372
    • /
    • 2006
  • Mission opportunities and trajectory characteristics for the future Korean Mars mission have designed and analyzed using KSIV-III(Korea Space Launch Vehicle-III). Korea's first space center, 'NARO space center' is selected as a launch site. For launch opportunities, year 2033 is investigated under considering the date of space center's completion with KSLV series development status. Optimal magnitude of various maneuvers, Trans Mars Injection (TMI) maneuver, Trajectory Correction Maneuver (TCM), Mars Orbit Insertion (MOI) maneuver and Orbit Trim Maneuver(OTM), which are required during the every Mars mission phases are computed with the formulation of nonlinear optimization problems using NPSOL software. Finally, mass budgets for upper stage (launcher for KSIV-III and spacecraft are derived using various optimized maneuver magnitudes. For results, daily launch window from NARO space center for successful Korean Mars mission is avaliable for next 27 minutes starting from Apr. 16. 2033. 12:17:26 (UTC). Maximum spacecraft gross mass which can delivered to Mars is about 206kg, with propellant mass of 109kg and structure mass of 97kg, when on board spacecraft thruster's Isp is assumed to have 290 sec. For upper stage, having structure ratio of 0.15 and Isp value of 280 sec, gross mass is about 1293kg with propellant mass of 1099kg and structure mass of 194kg. However, including 10% margins to computed optimal maneuver values, spacecraft gross mass is reduced to about 148kg with upper stage's mass of 1352kg. This work will give various insights, requiring performances to developing of KSIV-III and spacecraft design for future Korean Mars missions.

Performance Evaluation of High Strength Lattice Girder by Structural Analyses and Field Measurements (구조해석과 현장계측에 의한 고강도 격자지보재의 성능 평가)

  • Lee, Jeo-Won;Min, Kyong-Nam;Jeong, Ji-Wook;Roh, Byoung-Kuk;Lee, Sang-Jin;Ahn, Tae-Bong;Kang, Seong-Seung
    • The Journal of Engineering Geology
    • /
    • v.30 no.3
    • /
    • pp.237-251
    • /
    • 2020
  • This study examined structural analysis of supports in tunnel and displacement and underground stress of tunnel by measurement, in order to evaluate the performance of high-strength lattice girders developed as a substitute for H-profiles. According to the three-dimensional nonlinear structural analysis results of the tunnel support, the load and displacement relationship between the H-profiles and the high-strength lattice girders showed almost the same behavior, and the maximum load of the high-strength lattice girders were 1.0 to 1.2 times greater than the H-profiles. By the results of the three-dimensional tunnel cross-section analysis of the supports, the axial force was occurred largely in the lower left and right sides of the tunnel, and showed a similar trend to the field test values. In the results of the measurement of the roof settlement and rod extension, the final displacement of the steel arch rib (H-profile) and high-strength lattice girder section in tunnel was converged to a constant value without significant difference within the first management standard of 23.5 mm. According to the results of underground displacement measurement, the final change amount of the two support sections showed a slight displacement change, but converged to a constant value within the first management standard of 10 mm. By the results of measurement of shotcrete stress and steel arch rib stress, the final change amount of the two support sections showed a slight stress change, but converged to a constant value within the first management standard of 81.1 kg/㎠ and 54.2 tonf.

A Study of Traffic Incident Flow Characteristics on Korean Highway Using Multi-Regime (Multi-Regime에 의한 돌발상황 시 교통류 분석)

  • Lee Seon-Ha;kang Hee-Chan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.4 no.1 s.6
    • /
    • pp.43-56
    • /
    • 2005
  • This research has examined a time series analysis(TSA) of an every hour traffic information such as occupancy, a traffic flow, and a speed, a statistical model of a surveyed data on the traffic fundamental diagram and an expand aspect of a traffic jam by many Parts of the traffic flow. Based on the detected data from traffic accidents on the Cheonan-Nonsan high way and events when the road volume decreases dramatically like traffic accidents it can be estimated from the change of occupancy right after accidents. When it comes to a traffic jam like events the changing gap of the occupancy and the mean speed is gentle, in addition to a quickness and an accuracy of a detection by the time series analyse of simple traffic index is weak. When it is a stable flow a relationship between the occupancy and a flow is a linear, which explain a very high reliability. In contrast, a platoon form presented by a wide deviation about an ideal speed of drivers is difficult to express by a statical model in a relationship between the speed and occupancy, In this case the speed drops shifty at 6$\~$8$\%$ occupancy. In case of an unstable flow, it is difficult to adopt a statistical model because the formation-clearance Process of a traffic jam is analyzed in each parts. Taken the formation-clearance process of a traffic jam by 2 parts division into consideration the flow having an accident is transferred to a stopped flow and the occupancy increases dramatically. When the flow recovers from a sloped flow to a free flow the occupancy which has increased dramatically decrease gradually and then traffic flow increases according as the result analyzed traffic flow by the multi regime as time series. When it is on the traffic jam the traffic flow transfers from an impeded free flow to a congested flow and then a jammed flow which is complicated more than on the accidents and the gap of traffic volume in each traffic conditions about a same occupancy is generated huge. This research presents a need of a multi-regime division when analyzing a traffic flow and for the future it needs a fixed quantity division and model about each traffic regimes.

  • PDF

The Impact of Care Workers' Employment Characteristics and Perception of Facility Directors' Transformational Leadership on Quality of Service (요양보호사의 고용특성과 시설장에 대한 변혁적 리더십 인식이 서비스 질에 미치는 영향에 관한 연구)

  • Kim, Hye Ji;Park, Sang Hee;Kim, Bum Jung
    • 한국노년학
    • /
    • v.41 no.2
    • /
    • pp.217-240
    • /
    • 2021
  • The purpose of this study is to examine the effect of care workers' employment characteristics and perception of facility directors' transformational leadership on quality of service through a hierarchical linear model. For this aim, survey data were collected amongst 240 older adults and 200 care workers who are affiliated within 45 long-term care facilities in Seoul, and analyzed using SPSS 26.0 and HLM 8.0. As a result, one's perception of transformational leadership had a positive effect, whereas, among employment characteristics, employment type and working hours had negative effects on quality of service. Regular workers with fewer working hours and higher awareness of transformational leadership toward the director provided higher quality of service. But wage, total experience and tenure didn't meaningfully affect it. Therefore, the following suggestions were presented. First, it is necessary to reorganize incentive, salary systems and budgets, changing the status of temporary workers' hourly wage system into that of regular workers' monthly one in order to strengthen employment security with acknowledging fundamental professional values through reinforcement of expertise. Reinforcement of long-term care's publicness and establishment of base facilities are also suggested. Second, maintaining appropriate hours of work and rest including annual leave under the Labor Standards Act is needed. Also, increasing the salary of and decreasing working hours for night shift workers are required. Third, education and intervention for inspiring transformational leadership of directors and strengthening qualification standards of them are required.

Performance Evaluation of Fabric Sensors for Movement-monitoring Smart Clothing: Based on the Experiment on a Dummy (동작 모니터링 스마트 의류를 위한 직물 센서의 성능 평가: 더미 실험을 중심으로)

  • Cho, Hyun-Seung;Park, Sun-Hyeong;Kang, Da-Hye;Lee, Kang-Hwi;Kang, Seung-Jin;Han, Bo-Ram;Oh, Jung-Hoon;Lee, Hae-Dong;Lee, Joo-Hyeon;Lee, Jeong-Whan
    • Science of Emotion and Sensibility
    • /
    • v.18 no.4
    • /
    • pp.25-34
    • /
    • 2015
  • TThis study explored the requirement of fabric sensor that can measure the motion of the joint effectively by measuring and analyzing the variation in electric resistance of a sensor in accordance with bending and stretching motion of the arm by the implementation of a motion sensor utilizing conductive fabric. For this purpose, on both sides of two kinds of knitted fabric, namely 'L' fabric and 'W' fabric Single Wall Carbon Nano-Tube(SWCNT) was coated, fabric sensor was developed by finishing them in a variety of ways, and the sensor was attached to the arm band. The fabric sensor consisted of total 48 cases, namely background fabric for coating, the method of sensor attachment, the number of layer of sensors, the length of sensor, and the width of sensor. The performance of fabric motion sensors in terms of a dummy arm, that is, a Con-Trex MJ with 48 arm bands around it was evaluated. For each arm band, a total of 48, fastened around the dummy arm, it was adjusted to repeat the bending and stretching at the frequency : 0.5Hz, ROM : $20^{\circ}{\sim}120^{\circ}$, the voltage was recorded for each case after conducting three sets of repeat measurement for a total of 48 cases. As a result of the experiment, and as a consequences of the evaluation and analysis of the voltage based on the uniformity of the base line of the peak-to-peak voltage(Vp-p), the uniformity of Vp-p within the same set, and the uniformity of the Vp-p among three sets, the fabric sensors that have been configured in SWCNT coated 'L' fabric / welding / two layers / $50{\times}5mm$, $50{\times}10mm$, $100{\times}10mm$, and SWCNT coated 'W' fabric / welding / two layers / $50{\times}10mm$ exhibited the most uniform and stable signal value within 5% of the total variation rate. Through all these results of the experiment, it was confirmed that SWCNT coated fabric was suitable for a sensor that can measure the human limb operation when it was implemented as a fabric sensor in a variety of forms, and the optimal sensor types were identified.

A comparison study of the effects of hypertrophied adenoid tissue on jaws morphology (정상 교합자와 adenoid가 과식증된 부정교합자의 악골 형태의 비교)

  • Yu, Hyung-Seog;Park, Sun-Hyung
    • The korean journal of orthodontics
    • /
    • v.32 no.1 s.90
    • /
    • pp.19-31
    • /
    • 2002
  • To investigate the association between the hypertrophy of adenoid and jaw morphology during growth, this paper was based on children patients with experimental adenoids (male-15 subjects at each bone age group, female-15 subjects at each bone group) and comparing them to data taken from a control group (male-15 subjects at each bone age group, female-15 subjects at each bone group) with normal respiratory function. The comparisons between the groups were done at each growth stage using cervical vertebrae maturation index(CVMI) of Hassel. The obtained results were as follows : 1. The differences in craniofacial morphology between experimental group and control group were appeared from CVMI 3 and CVMI 4 (aroud adolescent period) in males, and from CVMI 1 in females. 2. The mandibular position of experimental group was more inferior than control group. The difference appeared at adolescent period(male : at CVMI 4, female : at CVMI 5). 3. Experimental group had greater anterior facial height than control group. This difference seemed a relation with lower anterior facial height. The difference appears at CVMI 3(11.94 ${\pm}$ 1.38 years old, at adolescent period) in male and at CVMI 1 in female. 4. The adenoid size of control male group was increased until CVMI 2(10.58 ${\pm}$ 1.07 years old, just before adolescent growth peak) and then decreased, but in female the adenoid size was decreased from CVMI 1(6.92 ${\pm}$ 0.53 years old).

A Study on the Men's Fashion Trend through the Statistical Analysis (통계적 분석을 통한 남성 패션 트렌드 연구)

  • Kim, Yoon-Kyoung;Lee, Kyoung-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.6 s.165
    • /
    • pp.837-847
    • /
    • 2007
  • 1,098 pieces of photographs($1995{\sim}2002$) of men's suit style have been classified according to fashion images in order to examine features and change aspects with statistical analysis. The findings of examining features of the trend by year with test of homogeneity, correspondence analysis, biplots, correlation analysis and regression analysis are as follows: (a) there are significant differences on fashion images as the trend by yew with test of homogeneity, (b) there are remarkable differences on the fashion trend by year with correspondence analysis and biplots. (c) There are significant correlations for appearance among fashion images by its frequency through correlation analysis, and (d) it is assumed that fashion images are going to be gradually outstanding according to regression analysis.

Study on the Physical Properties of the Gamma Beam-Irradiated Teflon-FEP and PET Film (Teflon-FEP 와 PET Film 의 감마선 조사에 따른 물리적 특성에 관한 연구)

  • 김성훈;김영진;이명자;전하정;이병용
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • Circular metal electrodes were vacuum-deposited with chromium on the both sides of Teflon-FEP and PET film characteristic of electret and the physical properties of the two polymers were observed during an irradiation by gamma-ray from $\^$60/Co. With the onset of irradiation of output 25.0 cGy/min the induced current increased rapidly for 2 sec, reached a maximum, and subsequently decreased. A steady-state induced current was reached about in 60 second. The dielectric constant and conductivity of Teflon-FEP were changed from 2.15 to 18.0 and from l${\times}$l0$\^$-17/ to 1.57${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/, respectively. For PET the dielectric constant was changed from 3 to 18.3 and the conductivity from 10$\^$-17/ to 1.65${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/. The increase of the radiation-induced steady state current I$\^$c/, permittivity $\varepsilon$ and conductivity $\sigma$ with output(4.0 cGy/min, 8.5 cGy/min, 15.6 cGy/min, 19.3 cGy/min) was observed. A series of independent measurements were also performed to evaluate reproducibility and revealed less than 1% deviation in a day and 3% deviation in a long term. Charge and current showed the dependence on the interval between measurements, the smaller the interval was, the bigger the difference between initial reading and next reading was. At least in 20 minutes of next reading reached an initial value. It may indicate that the polymers were exhibiting an electret state for a while. These results can be explained by the internal polarization associated with the production of electron-hole pairs by secondary electrons, the change of conductivity and the equilibrium due to recombination etc. Heating to the sample made the reading value increase in a short time, it may be interpreted that the internal polarization was released due to heating and it contributed the number of charge carriers to increase when the samples was again irradiated. The linearity and reproducibility of the samples with the applied voltage and absorbed dose and a large amount of charge measured per unit volume compared with the other chambers give the feasibility of a radiation detector and make it possible to reduce the volume of a detector.

  • PDF